PULS DP153 User Manual

DP153 1 Output
DIN Rail Power Supply, 40 to 60 Watt
High efficiency: 87% (@ 24V)
ACin 115/230V manual switch
WxHxD = 40x130x120mm
Parallel mode automatic load sharing
(DP153.133)
Meets EMV standards
EN 50081-1 (EN 55022/B), EN 50082-2 EN 61000-4 and NAMUR
Design meets VDE 0551 (EN 60 742)
Data Sheet
DP153
The DP153 is a compact power supply for applications using controllers, sensors, and actuators in industrial plants and heavy machines. Output voltage is stable over the total load range, with excellent ripple and noi­se values of < 20mVpp @ 24V DC.
Low weight and small size allow quick single-handed installation on TS35 DIN rails. The parallel-mode current sharing of the DP153.133 can improve output current performance.
The DP153 withstands line voltage disturbances ac cor­ding to EN 61000-4; VDE 0160 pulses (class 2 for total load range!) are filtered and regulated, so the load is not disturbed. The unit is protected against over-volt­age and short-circuits. Isolation is equivalent to safety transformers according to VDE 0551, and meets VBG 4.
www.puls-power.de
Schematic:
See the web for current data sheet version:
Vout Iout Pout Features Order-No.
10V 4A 12V 4A 24V 2.5A
24V 2.5A
27.6V 2A
Warranty: 2 years from date of delivery.
40W OVP 48W OVP 60W OVP
60W OVP, parallel mode 56W OVP, Vout adjustable
DP153.110 DP153.111 DP153.131
DP153.133 DP153.141
Output
Voltage Vout fixed DP153.110, 111, 131, 133.
Vout adjustable min. ± 5% DP153.141 only. Accuracy Includes: production-adjustment, DP153.110, 111, 131 max. ± 2% line regulation, DP153.133 max. ± 5% and load regulation.
DP153.141 max. ± 0.5% Sense lines None Not available. Minimum load None Not necessary. Output power Pout max. 60W Mounting side by side possible.
only DP153.133 max. 48W Per unit (@ parallel operation). Noise, Ripple max. 20mVpp 20Hz...200kHz.
incl. spikes max. 25mVpp 20Hz...20MHz. Over-voltage protection typ. 1.15 x Vout Threshold accuracy ± 4%. Derating 1W/K +60° to +70°C Ta. Operating indicator 1 green LED On the front. Isolation Vout to Vin SELV EN 60 950, VDE 0805. The output is protected against open-circuit, short-circuit, and overload.
Mechanical: Al/Mg alloy housing, snap-on mounting for
Weight: App. 460g
Screw terminals: Input 1 terminal, max. 2.5/4mm
Tel.: 0049.(0)89.9278-244
Fax: 0049.(0)89.9278-199 www.puls-power.de
DIN rail TS35/7.5 (EN 50022), WxHxD = 40 x 130 x 120mm, the depth includes the DIN-rail mounting, see page 4.
2
output 2 terminals, each max. 2.5/4mm see page 4.
Specifications valid for Vin = 230 V AC, Tamb = +25°C, and 5 min run-in time, unless otherwise stated. They are subject to change without prior notice.
,
2
Input
Line input AC 1 100...127V AC Switch position 115V.
Range 88...132V AC Full spec.
80...150V AC Derated, see page 2.
Line input AC 2 220...240V AC Switch position 230V.
Range 187...264V AC Full spec.
150...300V AC Derated, see page 2. Line frequency 47...63Hz DC or 400Hz, see page 2. Input current rms. max. 1.3Aeff. / 0.7Aeff. @ 115 / 230V AC.
,
Noise suppression EN 55 022/B 10kHz...30MHz, conducted.
Data sheet DP153
10.Mar.99
PULS Munich
Page 1
DP153
1 Output ◆ DIN Rail Power Supply ◆ 40 to 60 Watt
Output (continued) DP153. .110 .111 .131 .133 .141
Voltage regulation:
Line regulation max. %
Load regulation stat.
Load regulation dyn.
Response time t Temperature coefficient typ. %/K
U
max. %
stat
U
max. %
dyn
max. ms 1 1 1 1 1
s
Ripple max. mVpp 20 20 20 20 20
incl. spikes max. mVpp 25 25 25 25 25
Current limitation
Threshold min/max. A 105% ... 120% of Iout
Characteristic See graph on page 3
Short-circuit max. A 180% of Iout
Start delay t Vout rise-up time t
typ. ms 5
Delay
typ. ms 42
Rise
On and off characteristic Power back immunity U
(continued)
Input
max. V 1.2 x Vout
Back
AC input range 1 / 2 V AC 88...132 / 187...264 DC input range V DC 250...300 Derated AC range 1 / 2 V AC 80...88 / 150...187, 150 / 300 for 0.5s Derated DC range V DC 176...250
V DC 300...370
Frequency range Hz 47...63 Derated frequency range Hz 63...400 In-rush current max. A 14
Hold-up time min. ms 34
min. ms 46
Power factor
λ
typ. 0.66 Internal fuse 5x20mm T2A/250V Input range selection Manual (230V AC set at factory)
±
0.2± 0.2 ± 0.2 ± 0.2 ± 0.2
±
1.0± 1.0± 0.5± 4.0± 0.5
±
1.0± 1.0± 0.5 ± 2.0± 0.5
±
0.01± 0.01± 0.01± 0.01± 0.01
(IEC127/2-5)
88...132V AC / 187...264V AC, Iout = 100%. Iout = 50%, ∆ Iout = ±50%.
Iout = 10%...90%...10%, rise time dt = typ. 20µs. Till ∆Vout is within < 0.5% of final value.
20Hz...200kHz, @ AC nom, Iout = 100%. 20Hz...20MHz, @ AC nom, Iout = 100%.
Fixed.
After switch on.
Approximately monotonic. Unit off/on.
Full spec. Full spec.
Power derating typ. 20% (no start below 196V). Full spec, but air- and leakage distances not longer than stated in VDE 0805. Full spec. Increased leakage currents. Wait min. 30s before switching on again (cold-start), NAMUR standard met (Ta = 25° C). @ 88V AC, Iout = 100%. @ 187V AC, Iout = 100%, see figure on page 3. @ 88V AC, Iout = 100%. To replace, see page 4. 115/230V switch, position see page 4.
95%
t
0
t
DelaytRise
90% 10%
100Hz
Vout
Logic Functions
Parallel operation, DP153.133 only units
Current distribution
Connection No additional wiring needed.
Vout adjustable, DP153.141 only min. %
Equal —
Electromagnetic Compatibility
Emissions according to EN 50081-1
Radio interference, EN 55011, EN 55022 Class B (EN 50081-1)
Class A (EN 50081-2)
Immunity according to EN 50082-2 No degradation of performance
Electrostatic discharge ESD 8kV direct discharge (level 4)
EN 61000-4-2 15kV air discharge (level 4) Radiated fields, EN 61000-4-3 10V/m (level 3)
Fast transients, EN 61000-4-4 4kV (level 4)
2kV level 3) 2kV (level 4) cap. coupling
Surge transients EN 61000-4-5 4kV (isolation class 4)
2kV (isolation class 4)
Conducted disturb., ENV 50141 (draft of IEC 801-6) 10V (level 3)
Immunity according to further standards
Transient voltage, IEC 255 5kV
NAMUR-prescription Satisfied
Transient resistance, VDE 0160 §5.3.1.1.2 750V / 1.3ms (class 2)
Over-voltage resistance (PULS standard) 150 / 300V AC / 0.5s
No limit of number of units for DP153.133, 134. Characteristic see page 3. Use equal-length output cables.
±
5
Trimmer position see page 4.
EN 50081-2 is also satisfied For conducted emissions, 10kHz...30MHz, for radiated emissions, 30MHz...1000MHz, EN 50082-1 is also satisfied
80MHz...1000MHz, ACin and Vout lines: l = 1m. Coupled to ACin line. Coupled to DCout line. Coupled to Vout lines. Common mode, unit on. Differential mode, unit on. 150kHz...80MHz.
Common mode, unit off.
Valid for total load range. Switch position 115 / 230V AC.
PULS Munich Data sheet DP153
Page 2
10.Mar.99
Specifications valid for Vin = 230 V AC, Tamb = +25°C, and 5 min run-in time, unless otherwise stated. They are subject to change without prior notice.
Arabellastrasse 15
D-81925 Munich
www.puls-power.de