Puls Dimension CP, CP10.241-60 Series Manual

CP10.241-60
CP-Series
24V, 200W, DC/DC CONVERTER
DC/DC CONVERTER
EN 50155 Railway Compliant Conformal Coated PC-boards Quick-connect Spring-clamp Terminals 67-154Vdc Wide-range Input Width only 39mm Efficiency up to 94.5% Excellent Partial Load Efficiency Minimal Inrush Current Surge Full Power Between -40°C and +70°C DC-OK Relay Contact Reverse Input Polarity Protected 3 Year Warranty
1/27
GENERAL DESCRIPTION
The DC/DC converter CP10.241-60 is designed specifically for railway & transportation applications. It is approved according to the EN 50155 standard, which is an international standard covering electronic equipment used on rolling stock for railway applications. The standard covers aspects such as temperature, humidity, shock, vibration, EMI and other parameters. Because of these requirements, the unit is equipped with conformal coated pc-boards.
The unit features a DC-OK signal contact for remote monitoring, and quick-connect spring-clamp terminals for a reliable connection even when mechanical vibration and shock are involved. The unit also covers an extreme wide temperature range from -40°C up to +70°C with full output current.
This DC/DC converter comes in a very compact housing and requires only 39mm space on the DIN-rail due to the high efficiency and low power losses. The high efficiency is achieved by utilizing cutting edge technology and other unique design techniques.
SHORT-FORM DATA
Output voltage DC 24V Adjustment range 24 - 28V Output current 8.3 – 7.1A Continuous, < +70°C
8.3 – 7.1A For 10 minutes, < +85°C Input voltage DC DC 96 - 110V - 30%/ +40% Input voltage range 67.2 – 154V Input current DC 2.25 / 1.95A At 96 / 110Vdc Input inrush current 2.5A pk Efficiency 94.3 / 94.5% At 96 / 110Vdc Losses 12.1 / 11.6W At 96 / 110Vdc Hold-up time 34ms Temperature range -40 to +70°C Size (W x H x D) 39x124x117mm Without DIN-rail Weight 620g / 1.37lb
ORDER NUMBERS
DC/DC converter
CP10.241-60
Mechanical Accessory
ZM4.WALL Wall/panel mount bracket ZM12.SIDE Side mount bracket
MARKINGS
For details and a complete approval list see section 19.
Apr. 2018 / Rev. 1.0 DS-CP10.241-60-EN All parameters are typical values specified at 24V, 8.3A output, 110Vdc input, 25°C ambient and after a 5 minutes run-in time unless otherwise noted.
www.pulspower.com Phone +49 89 9278 0 Germany
CP10.241-60
CP-Series
24V, 200W, DC/DC CONVERTER
INDEX
Page Page
1.
Intended Use .......................................................3
2. Installation Requirements...................................4
3. DC-Input...............................................................5
4. AC-Input...............................................................6
5. Input Inrush Current ...........................................6
6. Output .................................................................7
7. Hold-up Time.......................................................8
8. DC-OK Relay Contact ..........................................9
9. Functional Diagram.............................................9
10. Efficiency and Power Losses..............................10
11. Lifetime Expectancy ..........................................11
12. MTBF ..................................................................11
13. Terminals and Wiring........................................12
14. Front Side and User Elements...........................13
15. EMC....................................................................14
16. Environment......................................................15
17. Dielectric Strength ............................................16
18. Safety and Protection Features ........................17
19. Approvals and Declarations..............................18
20. RoHS, REACH and Other Fulfilled Standards .. 18
21. Physical Dimensions and Weight..................... 19
22. Accessories ........................................................ 20
22.1. ZM4.WALL – Wall/Panel Mount Bracket .20
22.2. ZM12.SIDE - Side Mounting Bracket........21
22.3. UF20.241 Buffer Module .......................... 22
22.4. YR20.242 - Redundancy Module.............. 22
22.5. YR20.246 - Redundancy Module with
Automated Load Sharing ....................................22
23. Application Notes............................................. 23
23.1. Peak Current Capability ...........................23
23.2. Charging of Batteries ...............................24
23.3. Series Operation .......................................24
23.4. Parallel Use to Increase Output Power....24
23.5. Parallel Use for Redundancy ....................25
23.6. Use in a Tightly Sealed Enclosure ............26
23.7. Mounting Orientations ............................27
The information given in this document is correct to the best of our knowledge and experience at the time of publication. If not expressly agreed otherwise, this information does not represent a warranty in the legal sense of the word. As the state of our knowledge and experience is constantly changing, the information in this data sheet is subject to revision. We therefore kindly ask you to always use the latest issue of this document (available under www.pulspower.com).
No part of this document may be reproduced or utilized in any form without our prior permission in writing.
TERMINOLOGY AND ABREVIATIONS
PE and symbol PE is the abbreviation for Protective Earth and has the same meaning as the symbol .
Earth, Ground This document uses the term “earth” which is the same as the U.S. term “ground”.
T.b.d. To be defined, value or description will follow later.
DC 110V A figure displayed with the AC or DC before the value represents a nominal voltage with
standard tolerances (usually ±15%) included. E.g.: DC 12V describes a 12V battery disregarding whether it is full (13.7V) or flat (10V)
110Vdc A figure with the unit (Vdc) at the end is a momentary figure without any additional
tolerances included.
may A key word indicating flexibility of choice with no implied preference.
shall A key word indicating a mandatory requirement.
should A key word indicating flexibility of choice with a strongly preferred implementation.
Apr. 2018 / Rev. 1.0 DS-CP10.241-60-EN All parameters are typical values specified at 24V, 8.3A output, 110Vdc input, 25°C ambient and after a 5 minutes run-in time unless otherwise noted.
www.pulspower.com Phone +49 89 9278 0 Germany
2/27
CP10.241-60
CP-Series
24V, 200W, DC/DC CONVERTER
1. INTENDED USE
This device is designed for installation in an enclosure and is intended for general use such as in rolling stock for railway applications (according to EN 50155) or in industrial control, office, communication, and instrumentation equipment.
Do not use this device in equipment, where malfunction may cause severe personal injury or threaten human life.
Apr. 2018 / Rev. 1.0 DS-CP10.241-60-EN All parameters are typical values specified at 24V, 8.3A output, 110Vdc input, 25°C ambient and after a 5 minutes run-in time unless otherwise noted.
www.pulspower.com Phone +49 89 9278 0 Germany
3/27
CP10.241-60
CP-Series
24V, 200W, DC/DC CONVERTER
2. INSTALLATION REQUIREMENTS
This device may only be installed and put into operation by qualified personnel. This device does not contain serviceable parts. The tripping of an internal fuse is caused by an internal defect. If damage or malfunction should occur during installation or operation, immediately turn power off and send unit to
the factory for inspection. Install device in an enclosure providing protection against electrical, mechanical and fire hazards. Install the device onto a DIN-rail according to EN 60715 with the input terminals on the bottom of the device. Other
mounting orientations require a reduction in output current. Make sure that the wiring is correct by following all local and national codes. Use appropriate copper cables that are
designed for a minimum operating temperature of 60°C for ambient temperatures up to +45°C, 75°C for ambient temperatures up to +60°C and 90°C for ambient temperatures up to +70°C. Ensure that all strands of a stranded wire enter the terminal connection.
The device is designed for pollution degree 2 areas in controlled environments. No condensation or frost is allowed. The enclosure of the device provides a degree of protection of IP20. The device is designed as “Class of Protection I” equipment according to IEC 61140. Do not use without a proper PE (Protective Earth) connection. The device can be powered from a regulated power supply or a similar DC source. The voltage between the supply
voltage terminals and ground must not exceed 300Vdc continuously. A disconnecting means shall be provided for the input of the device. The output is electronically protected against no-load, overload and short circuit and can supply any kind of loads,
including unlimited inductive loads and capacitive loads. If capacitors with a capacitance >1.5F are connected, the unit might charge the capacitor in an intermittent mode.
Do not apply return voltages from the load to the output terminals higher than 35V. The device is designed for convection cooling and does not require an external fan. Do not obstruct airflow and do not
cover ventilation grid! The device is designed for altitudes up to 6000m (19685ft). See additional requirements in the product datasheet for
use above 2000m (6560ft). Keep the following minimum installation clearances: 40mm on top, 20mm on the bottom, 5mm left and right side.
Increase the 5mm to 15mm in case the adjacent device is a heat source. When the device is permanently loaded with less than 50%, the 5mm can be reduced to zero.
The device is designed, tested and approved for branch circuits up to 20A without additional protection device. If an external fuse is utilized, do not use circuit breakers smaller than 6A B- or 4A C-Characteristic to avoid a nuisance tripping of the circuit breaker.
The maximum surrounding air temperature is +85°C (+185°F). The operational temperature is the same as the ambient or surrounding air temperature and is defined 2cm below the device.
The device is designed to operate in areas between 5% and 95% relative humidity. Check for correct input polarity. The device will not operate when the voltage is reversed.
WARNING
Risk of electrical shock, fire, personal injury or death.
- Turn power off before working on the device. Protect against inadvertent re-powering.
- Make sure that the wiring is correct by following all local and national codes.
- Do not modify or repair the unit.
- Do not open the unit as high voltages are present inside.
- Use caution to prevent any foreign objects from entering the housing.
- Do not use in wet locations or in areas where moisture or condensation can be expected.
- Do not touch during power-on, and immediately after power-off. Hot surfaces may cause burns.
Apr. 2018 / Rev. 1.0 DS-CP10.241-60-EN All parameters are typical values specified at 24V, 8.3A output, 110Vdc input, 25°C ambient and after a 5 minutes run-in time unless otherwise noted.
www.pulspower.com Phone +49 89 9278 0 Germany
4/27
CP10.241-60
CP-Series
24V, 200W, DC/DC CONVERTER
3. DC-INPUT
Use a battery or a similar DC source. A supply from the intermediate DC-bus of a frequency converter is not recommended and can cause a malfunction or damage the unit.
Input voltage Nom. DC 96-110V -30%/+40% Input voltage range 67-154Vdc 57-67Vdc Short term for 2s, no start at 57Vdc Input current Typ. 2.25A At 8.3A and 96Vdc input voltage, see Fig. 3-3 Typ. 1.95A At 8.3A and 110Vdc input voltage, see Fig. 3-3 Allowed voltage between input
to earth (ground)
Max. 300Vdc Continuous, IEC 62477-1
Allowed input ripple voltage Max. 15Vpp
3Vpp
50Hz –10kHz 10kHz – 50kHz
Turn-on voltage Typ. 64.5Vdc Steady-state value, temperature independent, see Fig.
3-1
Shut-down voltage Typ. 62.5Vdc Steady-state value, temperature independent, see Fig.
3-1 Start-up delay Typ. 700ms At 96Vdc input, see Fig. 3-2 Typ. 600ms At 110Vdc input, see Fig. 3-2 Rise time Typ. 45ms At 8.3A constant current load, 0mF load capacitance Typ. 90ms At 8.3A constant current load, 8mF load capacitance,
see Fig. 3-2
Reverse input polarity protection Included The device will not operate when the voltage is
reversed. Turn-on overshoot Max. 200mV See Fig. 3-2 External input protection See recommendations in chapter .
Fig. 3-1 Input voltage range Fig. 3-2 Turn-on behavior, definitions
Turn-on
67V
Rated
input range
max.
500ms
V
IN
P
OUT
5/27
375Vdc154V
Shut-down
Start-up Rise
delay Time
Overshoot
- 5%
Output Voltage
Input Voltage
Fig. 3-3 Input current vs. output load at 24V
8
01234
0
0.5
1.0
1.5
2.5
Output Current
Input Current, typ.
567
9A
2.0
3A
(a) 96Vdc, (b) 110Vdc
(a) (b)
Apr. 2018 / Rev. 1.0 DS-CP10.241-60-EN All parameters are typical values specified at 24V, 8.3A output, 110Vdc input, 25°C ambient and after a 5 minutes run-in time unless otherwise noted.
www.pulspower.com Phone +49 89 9278 0 Germany
CP10.241-60
CP-Series
24V, 200W, DC/DC CONVERTER
4. AC-INPUT
Do not operate this DC/DC converter with an AC-input voltage. Use the CP10.241 or CP10.241-C1 (when conformal coating is needed) unit instead.
5. INPUT INRUSH CURRENT
An active inrush limitation circuit (inrush limiting fixed resistor which is bypassed by a relay) limits the input inrush current after turn-on of the input voltage.
The charging current into EMI suppression capacitors is disregarded in the first microseconds after switch-on.
DC 96V DC 110V
Inrush current Max. 8A
peak
8A
peak
Temperature independent
Typ. 2.5A
peak
2.5A
peak
Temperature independent
Inrush energy Max. 0.1A²s 0.1A²s Temperature independent
Fig. 5-1 Typical input inrush current behaviour at
nominal load and 25°C ambient
50ms/DIV
Input current
0.5A/DIV
Input voltage 20V/DIV
Output voltage 5V/DIV
Apr. 2018 / Rev. 1.0 DS-CP10.241-60-EN All parameters are typical values specified at 24V, 8.3A output, 110Vdc input, 25°C ambient and after a 5 minutes run-in time unless otherwise noted.
www.pulspower.com Phone +49 89 9278 0 Germany
6/27
CP10.241-60
CP-Series
24V, 200W, DC/DC CONVERTER
6. OUTPUT
The output provides a SELV/PELV/ES1 rated voltage, which is galvanically isolated from the input voltage. The device is designed to supply any kind of loads, including capacitive and inductive loads. If extreme large
capacitors, such as EDLCs (electric double layer capacitors or “UltraCaps”) with a capacitance >1.5F are connected, the unit might charge the capacitor in an intermittent mode.
Output voltage Nom. 24V Adjustment range Min. 24-28V Guaranteed
Max. 30V This is the maximum output voltage which can occur
at the clockwise end position of the potentiometer due to tolerances. It is not a guaranteed value which
can be achieved. Factory setting Typ. 24.1V ±0.2% At full load, cold unit Line regulation Max. 10mV Between 67 and 154Vdc Load regulation Max. 100mV Between 0A and 8.3A, static value Ripple and noise voltage Max. 50mVpp Bandwidth 20Hz to 20MHz, 50Ohm
Output current
Nom. 8.3A At 24V and an ambient temperature below 70°C or at
+85°C for maximum 10 minutes.
Nom. 7.1A At 28V and an ambient temperature below 70°C or at
+85°C for maximum 10 minutes. Fuse breaking current
1)
Typ. 30A Up to 12ms once every five seconds, see Fig. 6-2.
Overload protection Included Electronically protected against overload, no-load and
short-circuits. In case of a protection event, audible
noise may occur.
Overload behaviour Continuous current Output voltage above 13Vdc, see Fig. 6-1 Intermitted current2) Output voltage below 13Vdc, see Fig. 6-1
Overload/ short-circuit current Max. 10.6A Continuous current, see Fig. 6-1
Typ. 11.5A Intermitted current peak value for typ. 2s
Load impedance 50mOhm, see Fig. 6-3
Discharge current of output capacitors is not included.
Max. 4.3A Intermitted current average value (R.M.S.)
Load impedance 50mOhm, see Fig. 6-3 Output capacitance Typ. 4 400μF Included inside the power supply Back-feeding loads
Max. 35V The unit is resistant and does not show
malfunctioning when a load feeds back voltage to the
power supply. It does not matter whether the power
supply is on or off. The absorbing energy can be
calculated according to the built-in large sized output
capacitor.
1) The fuse braking current is an enhanced transient current which helps to start heavy loads or to trip fuses on faulty output branches. The
output voltage stays above 20V. See chapter 23.1 for additional measurements.
2) At heavy overloads (when output voltage falls below 13V), the power supply delivers continuous output current for 2s. After this, the
output is switched off for approx. 18s before a new start attempt is automatically performed. This cycle is repeated as long as the overload exists. If the overload has been cleared, the device will operate normally. see Fig. 6-2.
Apr. 2018 / Rev. 1.0 DS-CP10.241-60-EN All parameters are typical values specified at 24V, 8.3A output, 110Vdc input, 25°C ambient and after a 5 minutes run-in time unless otherwise noted.
www.pulspower.com Phone +49 89 9278 0 Germany
7/27
CP10.241-60
CP-Series
24V, 200W, DC/DC CONVERTER
Fig. 6-1 Output voltage vs. output current,
typ.
Fig. 6-2 Dynamic output current capability,
typ.
Output Voltage
0
01
4
8
12
28V
16
20
24
0
12A62 4 8
Adjustment Range
Output Current
A
B
A: continuous current B: intermitted current
Output Voltage
(dynamic behavior, < 12ms)
0
0
4
8
12
28V
16
20
24
50A2010 30 40515253545
Adjustment
Range
Output Current
Fig. 6-3 Short-circuit on output, Hiccup
PLUS
mode, typ.
Output Current
0
11.5A
18s
18s
18s
2s
2s
2s
t
Short -circuit
Normal
operation
Normal
operation
7. HOLD-UP TIME
The internal capacitor, which supplies the energy for the hold-up time is isolated by a diode to the input voltage. A short on the input line does not discharge the internal hold-up capacitor.
DC 96V DC 110V
Hold-up Time Typ. 72ms 72ms At 4.15A, see Fig. 7-1 Min. 54ms 54ms At 4.15A, see Fig. 7-1 Typ. 34ms 34ms At 8.3A, see Fig. 7-1 Min. 26ms 26ms At 8.3A, see Fig. 7-1
Fig. 7-1 Hold-up time vs. input voltage Fig. 7-2 Shut-down behavior, definitions
8/27
0
15
30
45
60
75ms
70 90 110 130 150Vdc
Hold-up Time
Input Voltage
at 8.3A, typ.
at 4.15A, min.
at 4.15A, typ.
at 8.3A, min.
- 5%
Output Voltage
Input Voltage
Hold-up Time
Apr. 2018 / Rev. 1.0 DS-CP10.241-60-EN All parameters are typical values specified at 24V, 8.3A output, 110Vdc input, 25°C ambient and after a 5 minutes run-in time unless otherwise noted.
www.pulspower.com Phone +49 89 9278 0 Germany
CP10.241-60
CP-Series
24V, 200W, DC/DC CONVERTER
8. DC-OK RELAY CONTACT
This feature monitors the output voltage on the output terminals of a running power supply.
Contact closes As soon as the output voltage reaches typ. 90% of the adjusted output voltage level. Contact opens As soon as the output voltage dips more than 10% below the adjusted output voltage.
Short dips will be extended to a signal length of 100ms. Dips shorter than 1ms will be ignored. Switching hysteresis 1V Contact ratings Maximal 60Vdc 0.3A, 30Vdc 1A, 30Vac 0.5A, resistive load Minimal permissible load: 1mA at 5Vdc Isolation voltage See dielectric strength table in section 18.
Fig. 8-1 DC-ok relay contact behavior
100ms
0.9* V
ADJ
<
1ms
10%
open
V
OUT
= V
ADJ
openclosed closed
>
1ms
9. FUNCTIONAL DIAGRAM
Fig. 9-1 Functional diagram
+
+
-
-
DC-ok contact
Output
Over-
Boost
Converter
(pre
conditioning)
Voltage
Protection
Output
Voltage
Regulator
Output
Filter
9/27
DC-ok Relay
Output
Voltage
Monitor
Output
Power
Manager
Temper-
ature Shut­down
DC-ok LED
Input Fuse Input Filter Active Inrush Limiter
V
OUT
Power
Converter
+
-
Reverse Polarity and Back-feeding Protection
-
Apr. 2018 / Rev. 1.0 DS-CP10.241-60-EN All parameters are typical values specified at 24V, 8.3A output, 110Vdc input, 25°C ambient and after a 5 minutes run-in time unless otherwise noted.
www.pulspower.com Phone +49 89 9278 0 Germany