CD–Series
DC/DC Converter; 24V, 5A
CD5.242
10. FUNCTIONAL DIAGRAM
Fig. 10-1 Functional diagram
Output
Voltage
Regulator
+
Chassis
Ground
-
Input Fuse
&
Input Filter
Reverse
Polarity
Protection
&
Inrush
Limiter
Over-
Temperature
Protection
Output
Over-
Voltage
Protection
Power
Converter
Output
Filter
V
OUT
+
+
-
-
DC
ok
11. RELIABILITY
Input: 48Vdc
Lifetime expectancy min. 169 000h 40°C, 24V, 2.5A
min. 64 000h 40°C, 24V, 5A
min. 39 000h 40°C, 24V, 6A
min. 181 000h 25°C, 24V, 5A
MTBF SN 29500, IEC 61709 951 000h 40°C, 24V, 5A
1 560 000h 25°C, 24V, 5A
MTBF MIL HDBK 217F 559 000h 40°C, 24V, 5A, Ground Benign GB40
749 000h 25°C, 24V, 5A, Ground Benign GB25
The Lifetime expectancy shown in the table indicates the operating hours (service life) and is determined by the
lifetime expectancy of the built-in electrolytic capacitors. Lifetime expectancy is specified in operational hours.
Lifetime expectancy is calculated according to the capacitor’s manufacturer specification. The prediction model allows
a calculation of up to 15 years from date of shipment.
MTBF stands for Mean Time Between Failure, which is calculated according to statistical device failures, and indicates
reliability of a device. It is the statistical representation of the likelihood of a unit to fail and does not necessarily
represent the life of a product.
July 08 / Rev. 1.2 DS-CD5.242-EN / All parameters are specified at 24V, 5A and 48Vdc input at 25°C ambient unless otherwise noted.
www.pulspower.com Phone +49 89 9278 0 Germany
8/21