Puls CD5.241-S1 Connection Diagram

CD5.241-S1
CD-Series
9. FRONT SIDE AND USER ELEMENTS
Fig. 9-1 Front side
A
Screw terminals + Positive input
- Negative (return) input Chassis ground: can be used to bond the housing to PE
Ground this terminal to minimize high-frequency emissions.
Output terminals
B
Screw terminals, dual terminals per pole, both pins are equal + Positive output
- Negative (return) output Screw terminals
Output voltage potentiometer
C
Open the flap to set the output voltage. Factory set: 24.1V
DC-OK LED (green)
D
Monitors the output voltage, which is produced by the DC/DC converter itself and is on when the voltage is higher than 90% of the adjusted output voltage. DC-OK lamp and DC-OK contact functions are synchronized
E
Signal terminals
Plug Connector for DC-OK and Input-low relay contact
F
Input-low LED (yellow) see also chapter 13.
On when the input voltage is between 4Vdc and 20Vdc.. Input-low LED and Input-low contact functions are synchronized
DC/DC Converter 24V, 5A
Oct 2009 / Rev. 1.3 DS-CD5.241-S1-EN All parameters are specified at 24V, 5A, 24Vdc input voltage, 25°C ambient and after a 5 minutes run-in time unless otherwise noted.
www.pulspower.com Phone +49 89 9278 0 Germany
9/22