PULS CD5.241, CD5.241-S1 User guide

CD–Series
1. GENERAL DESCRIPTION
The Dimension CD5-series offer DIN-rail DC/DC converters in the 120W output power range in a very compact housing.
These DC/DC converters are allowed to run from a battery, can also be used to refresh and stabilize the 24Vdc on the end of a long cable or to isolate specific loads from the 24V bus voltage.
The CD5.241 includes all the essential basic functions while the CD5.241-S1 is equipped with quick-connect spring clamp terminals, a DC-OK-contact which monitors the output and an input-low-relay-contact. Both devices have a power reserve of 20% and this extra power can be used continuously up to +45°C.
CD-Series
Related products
24V->24V
CD5.241
24V->24V
CD5.241-S1
24V->12V
CD5.121
48V->24V
CD5.242
Spring-clamp terminals, Input-low, DC-OK contacts
3. ORDER NUMBERS
DC/DC Converter
Accessories ZM1.WALL Wall mount bracket ZM11.SIDE Side mount bracket
YR2.DIODE Decoupling module
CD5.241
CD5.241-S1
YRM2.DIODE Redundancy module
Standard unit
Unit with signals and spring-clamp terminals
CD5.241, CD5.241-S1
DC/DC Converter; 24V, 5A
DC/DC CONVERTER
Wide Range DC Input (18-32.4Vdc)
Isolated 24Vdc Output
Efficiency up to 90.3%
Width only 32mm
20% Output Power Reserves
Full Output Power Between -25°C and +60°C
Soft Start Function Included
Minimal Inrush Current Surge
Reverse Input Polarity Protection
DC-OK and Input-low Relay Contact (CD5.241-S1)
3 Year Warranty
2. SHORT-FORM DATA
Output voltage DC 24V Adjustment range 23 - 28V
5 – 4.3A 6 – 5.1A
UL 60950-1
GL
Marine, pending
Ambient <60°C Ambient <45°C
(14 to 18Vdc with derating)
Class I Div 2,
pending
EMC, LVD
Output current
Output power 120W Ambient <60°C 144W Ambient <45°C Output ripple < 50mVpp 20Hz to 20MHz Input voltage DC 24V 18 to 32.4Vdc
Input current typ. 5.5A At 24Vdc input Input Inrush current typ. 1.2A peak Efficiency typ. 90.3% At 24Vdc input Losses typ. 12.9W At 24Vdc input Hold-up time typ. 6ms At 24Vdc input Temperature range -25°C to +70°C Operational Derating 3W/°C +60 to +70°C Dimensions 32x124x102mm WxHxD
4. MARKINGS
18WM
LISTED
IND. CONT. EQ.
UL 508
R
CUS
182790
pending
Jan. 08 / Rev. 1.1 DS-CD5.241-EN / All parameters are specified at 24V, 5A and 24Vdc input at 25°C ambient unless otherwise noted.
www.pulspower.com Phone +49 89 9278 0 Germany
CDSeries
CD5.241, CD5.241-S1
DC/DC Converter; 24V, 5A
INDEX PAGE INDEX PAGE
1.
General Description ............................................1
2. Short-form Data ..................................................1
3. Order Numbers....................................................1
4. Markings..............................................................1
5. Input Voltage ......................................................3
6. Soft-start and Input Inrush Current Surge .........4
7. Output .................................................................5
8. Hold-up Time.......................................................6
9. Efficiency and Power Losses................................7
10. Functional Diagram.............................................8
11. Reliability.............................................................8
12. Front Side and User Elements.............................9
13. Terminals and Wiring..........................................9
14. DC-OK Relay Contact (CD5.241-S1) ..................10
15. Input-low Relay Contact (CD5.241-S1) .............10
16. EMC....................................................................11
17. Environment......................................................12
18. Protection Features...........................................12
19. Safety .................................................................13
20. Dielectric Strength ............................................13
21. Approvals...........................................................14
22. Fulfilled Standards............................................ 14
23. Used Substances ............................................... 14
24. Physical Dimensions and Weight..................... 15
25. Installation and Operation Instructions .......... 15
26. Accessory........................................................... 16
27. Application Notes............................................. 17
27.1. Peak Current Capability......................... 17
27.2. Back-feeding Loads................................ 17
27.3. Inductive and Capacitive Loads ............. 17
27.4. Output Circuit Breakers ......................... 18
27.5. Series Operation..................................... 19
27.6. Parallel Use to Increase Output Power . 19
27.7. Daisy Chaining of Outputs..................... 19
27.8. Parallel Use for 1+1 Redundancy........... 20
27.9. Charging of Batteries............................. 20
27.10. Requirements for the Supplying Source 21
27.11. External Input Protection....................... 21
27.12. Use in a Tightly Sealed Enclosure .......... 21
27.13. Mounting Orientations.......................... 22
INTENDED USE
The DC/DC converter shall only be installed and put into operation by qualified personnel. This DC/DC converter is designed for installation in an enclosure and is intended for the general use, such as in
industrial control, office, communication, and instrumentation equipment. Do not use this device in aircraft, trains and nuclear equipment, where malfunctioning of the DC/DC converter may cause severe personal injury or threaten human life.
TERMINOLOGY AND ABREVIATIONS
PE and symbol PE is the abbreviation for Protective Earth and has the same meaning as the symbol .
Earth, Ground This document uses the term “earth” which is the same as the U.S. term “ground”.
T.b.d. To be defined, value or description will follow later.
DC 24V A figure displayed with the AC or DC before the value represents a nominal voltage with
standard tolerances included. E.g.: DC 12V describes a 12V battery regardless whether it is full (13.7V) or flat (10V)
24Vac A figure with the unit (Vdc) at the end is a momentary figure without any additional
tolerances included.
DISCLAIMER
The information presented in this document is believed to be accurate and reliable and may change without notice. Some parts of this unit are patent by PULS (US patent No 091662,063, Des. 424,529, …). No part of this document may be reproduced or utilized in any form without permission in writing from PULS GmbH.
Jan. 08 / Rev. 1.1 DS-CD5.241-EN / All parameters are specified at 24V, 5A and 24Vdc input at 25°C ambient unless otherwise noted.
www.pulspower.com Phone +49 89 9278 0 Germany
CDSeries
CD5.241, CD5.241-S1
DC/DC Converter; 24V, 5A
5. INPUT VOLTAGE
Input Input voltage range
14.0-18.0Vdc Max. 60 seconds or with de-rating see Fig. 5-2
Allowed voltage between input and earth (ground)
Allowed input ripple voltage
Turn-on voltage typ. 17.5Vdc Steady-state value, see Fig. 5-1 Shut-down voltage typ. 14.0Vdc Steady-state value, see Fig. 5-1
Input current Start-up delay typ. Rise time typ. 80ms 0mF, 24V, constant current load 5A, see Fig. 5-3
Turn-on overshoot Input capacitance typ.
External capacitors on the input voltage bus are allowed without any limitations.
Fig. 5-1 Input voltage range
P
OUT
Shut-down
14.0Vdc
Rated input range
Turn-on
17.5Vdc
18.0Vdc
Fig. 5-3 Turn-on behavior, definitions Fig. 5-4 Input current vs. output load
Intput Voltage
Output Voltage
- 5%
Start-up
delay
Rise
Time
nom. DC 24V nom. 18.0-32.4Vdc Continuous operation
max. 36.0Vdc Absolute maximum continuous input voltage with no
damage to the DC/DC converter.
max. 60Vdc or
42.4Vac
max. 5Vpp 47Hz-40kHz, the momentary input voltage must always be
within the specified limits.
typ. 35Vdc Steady-state value, see Fig. 5-1 typ. 5.5A At 24Vdc input and output 24V, 5A, see Fig. 5-4
650ms
See Fig. 5-3
typ. 150ms 5mF, 24V, constant current load 5A, see Fig. 5-3
32.4Vdc
500mV 3 000µF
V
IN
35.0Vdc
Overshoot
See Fig. 5-3
Fig. 5-2 Allowable output current below 18V
Output Current
6A
5
4
3
2
1
0
14 16 18 20 24Vdc
Input
8A
Current, typ.
6
4
2
0
1
1.5 2 3
input voltage
)
a
(
)
b
(
(a) Ambient < 45°C (b) Ambient < 60°C
Input Voltage
Output Current
3.5
2.5
u
p
n
I
n
I
4
:
t
p
4.5
22
c
d
V
8
1
V
4
2
:
t
u
5
d
5.5
c
6A
max.
Jan. 08 / Rev. 1.1 DS-CD5.241-EN / All parameters are specified at 24V, 5A and 24Vdc input at 25°C ambient unless otherwise noted.
www.pulspower.com Phone +49 89 9278 0 Germany
CDSeries
CD5.241, CD5.241-S1
DC/DC Converter; 24V, 5A
6. SOFT-START AND INPUT INRUSH CURRENT SURGE
Inrush current limitation
An active inrush limitation circuit (inrush limiting resistor which is bypassed by a relay contact) limits the input inrush current after turn-on of the input voltage.
The charging current into EMI suppression capacitors is disregarded in the first microseconds after switch-on.
Inrush current
max. 1.6A typ. 1.2A Inrush energy
typ. negligible -25°C to +70°C
Fig. 6-1 Input inrush current, typical behavior
Input Current
Input Voltage
Input 24Vdc
-25°C to +70°C
peak
-25°C to +70°C
peak
Input: 24Vdc Output: 24Vdc, 5A, constant current load Ambient: 25°C
Upper curve: Input current 2A / DIV Middle curve: Input voltage 20V / DIV Lower curve: Output voltage 20V / DIV Time scale: 100ms / DIV
Output Voltage
Soft-start function:
After the DC/DC converter is turned on, the internal output current rises slowly to its nominal value. This method charges the output capacitors (internal and external capacitors) slowly and avoids high input currents during turn-on. High input currents can produce a high voltage drop on the input wiring (especially with long and thin cables) which reduces the terminal voltage on the DC/DC converter. If the terminal voltage is below the shut-down voltage, the DC/DC converter will turn-off and will make a new start-up attempt. This effect is avoided with the integrated soft­start function. Please note, that this function increases the rise time of the output voltage by a small amount.
Fig. 6-2 Soft-start behavior
Input: 24Vdc Output: 24Vdc, 5A, constant current load Ambient: 25°C No additional external capacitors
Input Current
Upper curve: Input current 2A / DIV Lower curve: Output voltage 10V / DIV Time scale: 20ms / DIV
Output Voltage
Jan. 08 / Rev. 1.1 DS-CD5.241-EN / All parameters are specified at 24V, 5A and 24Vdc input at 25°C ambient unless otherwise noted.
www.pulspower.com Phone +49 89 9278 0 Germany
A
CDSeries
CD5.241, CD5.241-S1
DC/DC Converter; 24V, 5A
7. OUTPUT
Output voltage Adjustment range max. 30V At clockwise end position of potentiometer Factory setting Line regulation Load regulation max. 100mV CD5.241; static value, 0A Æ 5A Æ 0A
Ripple and noise voltage Output capacitance typ. Output current nom. 6A At 24V, ambient < 45°C, see Fig. 7-1 nom. 5A
Output power nom. 144W Ambient < 45°C nom. 120W Short-circuit current max. 10A Load impedance 200mOhm, see Fig. 7-1
Fig. 7-1 Output voltage vs. output current,
typ. (24Vdc input voltage)
nom. 24V min. 23-28V Guaranteed
max.
24.1V 25mV
±0.2%, at full load, cold unit
Input variations between 18 to 32.4Vdc
max. 150mV CD5.241-S1; static value, 0A Æ 5A Æ 0A max.
50mVpp 2200µF
20Hz to 20MHz, 50Ohm
At 24V, ambient < 60°C, see
Fig. 7-1
nom. 5.1A At 28V, ambient < 45°C, see Fig. 7-1 nom. 4.3A
At 28V, ambient < 60°C, see
Fig. 7-1
Ambient < 60°C
min. 7A Load impedance 200mOhm, see Fig. 7-1
Fig. 7-2 Current limitation vs. input voltage,
typ. (23V constant voltage load)
Output Voltage
28V
24
20
16
12
8
4 0
Adjustment
Range
Output Current
048
1062
12
Output Current
6.6A
6.5
6.4
6.3
6.2
6.1
6.0
5.9
5.8 15 21 27
Input Voltage
33Vdc302418
Peak current capability (up to several ms)
The DC/DC converter can deliver a peak current which is higher than the specified short term current. This helps to start current demanding loads or to safely operate subsequent circuit breakers.
The extra current is supplied by the output capacitors inside the DC/DC converter. During this event, the capacitors will be discharged and cause a voltage dip on the output. Detailed curves can be found in chapter 27.1.
Peak current voltage dips typ. from 24V to 15V
typ. from 24V to 18V At 10A for 50ms, resistive load
At 20A for 2ms, resistive load
typ. from 24V to 11.5V
At 20A for 5ms, resistive load
Jan. 08 / Rev. 1.1 DS-CD5.241-EN / All parameters are specified at 24V, 5A and 24Vdc input at 25°C ambient unless otherwise noted.
www.pulspower.com Phone +49 89 9278 0 Germany
CDSeries
CD5.241, CD5.241-S1
DC/DC Converter; 24V, 5A
8. HOLD-UP TIME
The input side of the DC/DC converter is equipped with a bulk capacitor which keeps the output voltage alive for a certain period of time when the input voltage dips or is removed. The bulk capacitor can be discharged by loading the DC/DC converter on the output side or through a load which is parallel to the input. There is no protection in the DC/DC converter which prevents current from flowing back to the input terminals. If prevention is needed, an external diode should be used.
Input 24Vdc
Hold-up Time typ. 11.8ms Input 24Vdc, output: 24Vdc, 2.5A, see Fig. 8-1 typ. 6ms Input 24Vdc, output: 24Vdc, 5A, see Fig. 8-1
Fig. 8-1 Hold-up time vs. input voltage
Hold-up Time
12ms
10
8
6
4
2
0
Input Voltage
18 20 22 24 28Vdc
(
a
)
)
(
b
)
c
(
)
(
d
(a) 24V, 2.5A, typ. (b) 24V, 2.5A, min. (c) 24V, 5A, typ. (d) 24V, 5A, min.
26
Fig. 8-2 Shut-down test setup Fig. 8-3 Shut-down behavior, definitions
DC/DC
Converter
S1
Input
Output
CD5
+
+
Load
-
-
DC
Source
+
-
Intput Voltage
Output Voltage
S1 opens
- 5%
Hold-up Time
Note: At no load, the hold-up time can be up to several seconds. The green DC-ok lamp is also on during this time.
Jan. 08 / Rev. 1.1 DS-CD5.241-EN / All parameters are specified at 24V, 5A and 24Vdc input at 25°C ambient unless otherwise noted.
www.pulspower.com Phone +49 89 9278 0 Germany
A
A
c
c
CDSeries
CD5.241, CD5.241-S1
DC/DC Converter; 24V, 5A
9. EFFICIENCY AND POWER LOSSES
Input 24Vdc
Efficiency typ. 90.3% 5A, 24V Power losses typ. 0.7W CD5.241 at no output load
1.1W CD5.241-S1 at no output load typ. 6.2W 2.5A, 24V typ. 12.9W 5A, 24V typ. 16.3W 6A, 24V
Fig. 9-1 Efficiency vs. output current at 24V Fig. 9-2 Losses vs. output current at 24V
Efficiency
91%
90
89
88
87
86
85
Output Current
1
245
3
6
Power Losses
18W
15
12
9
6
3
0
012 456
Fig. 9-3 Efficiency vs. input voltage, 24V, 5A Fig. 9-4 Losses vs. input voltage, 24V, 5A
Efficiency
91%
90.5
90.0
89.5
89.0
88.5
88.0 18 20 22 26 28 32
Input Voltage
24 30
Vd
Power Losses
18W
15
12
9
6
3
0
18 20 24 26 28 32
Output Current
3
Input Voltage
22 30
Vd
Jan. 08 / Rev. 1.1 DS-CD5.241-EN / All parameters are specified at 24V, 5A and 24Vdc input at 25°C ambient unless otherwise noted.