This triple-output power supply uses a two-step widerange converter and an active MOSFET rectifier. It operates over a wide range (100 - 240V AC) withou t any
switch over.
Hold-up time is up to 250ms at 23 0V AC. Load distribution is flexible; there is no m inimum load and the
full power of 60W can be delivered from any on e output.
EMC compatibility is a major feature. It has low spurious noise, and noise suppression meets EN 55022
class B. Noise immunity meets EN 61000-4 and VDE
0106 class 2, even at full load.
Over-voltage and over-temperature protection avoid
problems even in extreme working environments.
www.puls-power.de
Schematic:
See the web for current data sheet version:
Vout [DC]Iout a/b*PoutFeaturesOrder-No.
Vout1
Max. total power:60W
Vout1
Max. total power:60W
"F" appended to Order No. means front panel 8 HP included and fitted.
*
Iout a:Current range with increased accuracy (see page 2).
Vout2,3max. 10mVpp20Hz...20MHz .
Over-voltage protectiontyp. 6.0V Vout1, threshold accur. ± 3,5%.
Derating1.5W/K+55° to +70°C Ta.
Operating indicator1 green LEDOn the front, Vout1.
Isolation Vout to VinSELVEN 60 950, VDE 0805.
Vout1 to Vout2/3500V AC
All outputs are protected against open-circuit, short-circuit, and overload.
Mechanical:8HP / 3U board (DIN 41494),
Al/Mg alloy cover for component side,
plastic cover for bottom side,
LxWxH = 171.93 x 40.64 x 110mm,
the length includes the connector, see page 4.
Weight:App. 570g
Connector:H15 (DIN 41612), coding option,
max. load per pin 11A @ 70° C.
Input
Line input AC 100...240V ACWide-range converter.
Range85...265V ACFull spec.
⋅
Line input DC275V DCWide-range converter.
Range88...300V DCFull spec.
⋅
Line frequency47...63HzDC or 400Hz, see page 2.
Input current rmsmax. 1.5A@ 85V AC.
Noise suppressionEN 55 022/B
Specifications are valid at 230V AC, unless otherwise stated. They are subject to change without prior
notice.
AP346 ◆ 3 Outputs ◆ 19" Power Supply ◆ 60 Watt
AP346.112AP346.122
Output
Voltage regulation
⋅
⋅
⋅
⋅
Ripplemax.mVpp10101010
⋅
Current limitation
⋅
⋅
Start delayt
Vout rise up timet
On and off characteristicmax.mV
Power back immunity U
Load capacitymax.
Input (continued)
AC input rangeV AC85...265
DC input rangeV DC88...300
Derated AC rangeV AC75...85, 300 for 0.5s
Derated DC rangeV DC300...370
Frequency rangeHz47...63
Derated frequency rangeHz63...400
In-rush currentmax.A20
Hold-up timemin.ms250
Power factor
Internal fuse5x20mm T3.15A/250V
Input range selectionWide range
(continued)
Line regulationmax.%
Load regulation stat.
Load regulation dyn.
Response timet
∆
U
max.%
stat
∆
U
max.%
dyn
max.ms11.511.5
s
Temperature coefficienttyp.%/K
5.15V ±12V5V±15V
±
−
0.7/1± 0.2/3−0.7/1± 0.3/3.5
±
±
0.1
5/8
0.01
±
±
0.1
0.8/3
±
0.1± 0.1
±
5/8± 1/2
±
0.01
incl. spikesmax.mVpp20102010
Thresholdtyp.W6666
Short-circuitmax.A1.4 x Iout b1.4 x Iout b
Delay
Rise
back
typ.ms500500
typ.ms1515
+
3000+3000
max.V————
µ
F20,0002x2,00020,000 2x2,000
min.ms40
min.ms25
λ
typ.0.65
95%
t
0
90%
10%
t
DelaytRise
100Hz
Vout
85...265V AC, Iout = 100%.
Iout = 0%, ∆Iout = +100%, Iout a/b.
10%...90%...10% load change, Iout a/b,
rise time dt = typ. 20µs.
Till ∆Vout is within < 0.5% of final value.
20Hz...200kHz, @ AC nom., Iout = 100%.
20Hz...20MHz, @ AC nom., Iout = 100%.
Fixed, total power.
Switch off with periodic restart.
After switch on.
Parallel operation with decoupling diodes only
Do not exceed for safe start up.
Full spec.
Full spec.
Full spec, but air- and leakage distances not longer than
stated in VDE 0805.
Full spec.
Increased leakage currents.
Wait min. 30s before switching on again (cold-start).
@ 230V AC, Iout = 100%, see figure on page 3.
@ 110V AC, Iout = 100%, see figure on page 3.
@ 90V AC, Iout = 100%, see figure on page 3.
@ 98V AC, Iout = 100%.
n the L line, as per IEC 127/2-5. To replace, see page 4.
I
Logic Functions
PF-signalPower fail
PF high ifACin > 80V AC
⋅
Hold-up time
from power failure to PF-signalmin.ms245
⋅
min.ms45
min.ms25
from PF-signalmin.ms5
⋅
Vout 2 and Vout 3 serial modeV5
Electromagnetic Compatibility
Emissions according to EN 50081-1
Radio interference, EN 55011, EN 55022
⋅
Immunity according to EN 50082-2
Electrostatic discharge ESD
⋅
Radiated fields, EN 61000-4-3
⋅
Fast transients, EN 61000-4-4
⋅
Surge transients, EN 61000-4-5
⋅
Conducted disturb., ENV 50141 (draft of IEC 801-6)
⋅
Immunity according to further standards
Transient voltage, IEC 255
⋅
NAMUR-prescription
⋅
Transient resistance, VDE 0160 §5.3.1.1.2
⋅
Over-voltage resistance (PULS standard)
⋅
Class B
No degradation of performance
8kV direct discharge (level 4)
15kV air discharge (level 4)
10V/m (level 3)
4kV (level 4)
2kV (level 3)
2kV (level 4) cap. coupling
4kV (isolation class 4)
2kV (isolation class 4)
10V (level 3)
Open-collector (I
Open-collector.
See diagram on page 3, Iout = 100%.
@ 230V ACin.
@ 110V ACin.
@ 90V ACin.
+
30
See installation hints.
EN 50081-2 is also satisfied.
EN 50082-1 is also satisfied.
80MHz...1000MHz, ACin, Vout and signal lines: l = 1m.
Coupled to ACin line.
Coupled to DCout line.
Coupled to Vout and signal lines.
Common mode, unit on.
Differential mode, unit on.
150kHz...80MHz.
Common mode, unit off.
Valid for total load range.
= 5mA), see figure on page 3.
max
3 Outputs ◆ 19" Power Supply ◆ 60 Watt ◆ AP346
PF-Signal and Hold-Up Time
Min. Hold-Up Time
1000
100
Hold-Up Time [ms]
10
80 110 140 170 200 230 260 290
Input Voltage [VAC]
Typ. Derating over Temperature
70
60
50
40
30
Output Power Pout [W]
20
10
505560657075
60 Watt
Temperature [+ °C]
20W
30W
40W
60W
Protection
Unit protection
OverloadYesTotal-power limit.
⋅
Short-circuit proofYesAuto restart after 400ms.
⋅
Open-circuit proofYes
⋅
Over-temp. (OTP)typ.+100° CSwitch off.
⋅
on heatsinktyp. +98° CSwitch on (automatically).
Reverse battery prot.Yes
⋅
ACin range selectionWide range
⋅
Load protection
Over-voltage (OVP)YesSwitch off.
⋅
Thresholdtyp. 6.0VValid for Vout 1.
Accuracymax.± 3.5%
RestartAfter line disconnection, wait
time 1 min.
Safety
Electrical safety
Test voltage (each unit)3kV ACPrimary / secondary.
⋅
according to EN 60 9502.5kV ACPrimary / PE.
for t = 2sec500V ACSecondary / PE.
Air- and leakage distance6.4 / 8mmPrimary / secondary.
MTBF according to Siemens
standard SN29500typ.260,000h230VAC, Iout = 100%, +40°C Ta.
Only long life (>2,000h @ 105° C) electrolytic capacitors are used.
Function test
In-circuit test
Run-in (burn-in)
100% Test certificate enclosed.
Yes
24hFull load, Ta = +55° C,
his technical information is valid for +25° C ambient
temperature and 5 minutes run in time, unless otherwise stated.
T
on/off cycle.
AP346 ◆ 3 Outputs ◆ 19" Power Supply ◆ 60 Watt
Do not
obstruct
air flow!
Pin 4
LED green
(Vout 1)
3.0
3.0
2.5
3.5
2.5
(2x)
Fuse
The PSU has electronic protection against external
short-circuits. In case of an internal defect, a fuse
disconnects the unit. It can only be replaced by
opening the unit which should be done by the
supplier.
Installation for Operating
The unit is constructed for 19" systems:
Ensure that pin 4 of H15 connector is on top. For
other installation considerations consult your
representative. Ensure free air flow!
Dimensions and Connections
19" board, with Al/Mg alloy c over on co mpon ent side,
and a plastic cover on the bottom side. 8HP plug in
width. See figure below for dimensions.
Schematic
F
I
L
T
E
R
Controller
PF
Over-Temperature
Protection OTP
Inverter
typ.
75kHz
Controller
Over-Temperature
Protection OTP
OVP
Regulator
linear
Regul.
linear
Regul.
Caution:
Do not remove any screws o n box, as internal safety
connections could be disconnected!
z
d
4
6
8
10
12
14
16
18
20
22
24
26
28
30
32
H15 pinout (DIN 41312)
NC = No Connection - Do not use!
Modifications (contact supplier)
Without PF-Signal.
Lower cost versions.
Accessory ZP510
Installation set for mounting on DIN rail.