Puls AP346 Data Sheet

AP346 3 Outputs
19" Power Supply, 60 Watt
High efficiency: 82%
ACin wide range: 85...265V AC
DCin wide range: 88...300V DC
8 HP plug in width
Full power rail sharing / no min. load
Meets EMC standa
50081-1 (EN 55022/B),EN 50082-2,
EN and
EN 61000-4
rds
EN 60 950
NAMUR
390
Power Supply AP346
This triple-output power supply uses a two-step wide­range converter and an active MOSFET rectifier. It ope­rates over a wide range (100 - 240V AC) withou t any switch over.
Hold-up time is up to 250ms at 23 0V AC. Load distri­bution is flexible; there is no m inimum load and the full power of 60W can be delivered from any on e out­put.
EMC compatibility is a major feature. It has low spu­rious noise, and noise suppression meets EN 55022 class B. Noise immunity meets EN 61000-4 and VDE 0106 class 2, even at full load. Over-voltage and over-temperature protection avoid problems even in extreme working environments.
www.puls-power.de
Schematic:
See the web for current data sheet version:
Vout [DC] Iout a/b*Pout Features Order-No.
Vout1
Max. total power: 60W
Vout1
Max. total power: 60W
"F" appended to Order No. means front panel 8 HP included and fitted.
*
Iout a: Current range with increased accuracy (see page 2).
*
Iout b: maximum output current (see page 2).
Accessories: H15 connector, 6.3mm flat contacts:
Warranty: 2 years from date of delivery.
5.15V 8A / 12A
2
+12V 2A / 5A
3
–12V 2A / 5A
5.15V 8A / 12A
2
+15V 1.5A / 4A
3
–15V 1.5A / 4A
H15 connector with soldering pins:
60W Wide input range, 60W PF, OTP, OVP 60W
60W Wide input range, 60W PF, OTP, OVP 60W
AP346.112
AP346.122
ZP100 ZP120
Output
Voltage Vout1,2,3 Fixed.
Accuracy Vout1 max. ± 0.5% Includes production-adjustment
Vout2/3 max. ± 2.0% with no load. Sense lines None Not available. Minimum load None Not necessary. Output power Pout max. 60W Total power.
Pout1,2,3 max. 60W Each. Noise, Ripple Vout1 max. 10mVpp 20Hz...200kHz.
Vout2,3 max. 10mVpp 20Hz...200kHz.
incl. spikes Vout1 max. 20mVpp 20Hz...20MHz.
Vout2,3 max. 10mVpp 20Hz...20MHz . Over-voltage protection typ. 6.0V Vout1, threshold accur. ± 3,5%. Derating 1.5W/K +55° to +70°C Ta. Operating indicator 1 green LED On the front, Vout1. Isolation Vout to Vin SELV EN 60 950, VDE 0805.
Vout1 to Vout2/3 500V AC
All outputs are protected against open-circuit, short-circuit, and overload.
Mechanical: 8HP / 3U board (DIN 41494),
Al/Mg alloy cover for component side, plastic cover for bottom side, LxWxH = 171.93 x 40.64 x 110mm,
the length includes the connector, see page 4. Weight: App. 570g Connector: H15 (DIN 41612), coding option,
max. load per pin 11A @ 70° C.
Input
Line input AC 100...240V AC Wide-range converter.
Range 85...265V AC Full spec.
Line input DC 275V DC Wide-range converter.
Range 88...300V DC Full spec.
Line frequency 47...63Hz DC or 400Hz, see page 2. Input current rms max. 1.5A @ 85V AC. Noise suppression EN 55 022/B
Specifications are valid at 230V AC, unless otherwise stated. They are subject to change without prior notice.
AP346 ◆ 3 Outputs ◆ 19" Power Supply ◆ 60 Watt
AP346.112 AP346.122
Output
Voltage regulation
⋅ ⋅ ⋅
Ripple max. mVpp 10 10 10 10
Current limitation
⋅ ⋅
Start delay t Vout rise up time t On and off characteristic max. mV Power back immunity U Load capacity max.
Input (continued)
AC input range V AC 85...265 DC input range V DC 88...300 Derated AC range V AC 75...85, 300 for 0.5s Derated DC range V DC 300...370
Frequency range Hz 47...63 Derated frequency range Hz 63...400 In-rush current max. A 20 Hold-up time min. ms 250
Power factor Internal fuse 5x20mm T3.15A/250V Input range selection Wide range
(continued)
Line regulation max. % Load regulation stat. Load regulation dyn.
Response time t
U
max. %
stat
U
max. %
dyn
max. ms 1 1.5 1 1.5
s
Temperature coefficient typ. %/K
5.15V ±12V 5V ±15V
±
0.7/1± 0.2/3−0.7/1± 0.3/3.5
±
±
0.1
5/8
0.01
±
±
0.1
0.8/3
±
0.1± 0.1
±
5/8± 1/2
±
0.01
incl. spikes max. mVpp 20 10 20 10
Threshold typ. W 66 66 Short-circuit max. A 1.4 x Iout b 1.4 x Iout b
Delay Rise
back
typ. ms 500 500 typ. ms 15 15
+
300 0 +300 0
max. V
µ
F 20,000 2x2,000 20,000 2x2,000
min. ms 40 min. ms 25
λ
typ. 0.65
95%
t
0
90% 10%
t
DelaytRise
100Hz
Vout
85...265V AC, Iout = 100%. Iout = 0%, ∆Iout = +100%, Iout a/b. 10%...90%...10% load change, Iout a/b, rise time dt = typ. 20µs. Till ∆Vout is within < 0.5% of final value.
20Hz...200kHz, @ AC nom., Iout = 100%. 20Hz...20MHz, @ AC nom., Iout = 100%.
Fixed, total power. Switch off with periodic restart.
After switch on.
Parallel operation with decoupling diodes only Do not exceed for safe start up.
Full spec. Full spec.
Full spec, but air- and leakage distances not longer than stated in VDE 0805. Full spec. Increased leakage currents. Wait min. 30s before switching on again (cold-start). @ 230V AC, Iout = 100%, see figure on page 3. @ 110V AC, Iout = 100%, see figure on page 3. @ 90V AC, Iout = 100%, see figure on page 3. @ 98V AC, Iout = 100%.
n the L line, as per IEC 127/2-5. To replace, see page 4.
I
Logic Functions
PF-signal Power fail
PF high if ACin > 80V AC
Hold-up time
from power failure to PF-signal min. ms 245
min. ms 45 min. ms 25
from PF-signal min. ms 5
Vout 2 and Vout 3 serial mode V 5
Electromagnetic Compatibility
Emissions according to EN 50081-1
Radio interference, EN 55011, EN 55022
Immunity according to EN 50082-2
Electrostatic discharge ESD
Radiated fields, EN 61000-4-3
Fast transients, EN 61000-4-4
Surge transients, EN 61000-4-5
Conducted disturb., ENV 50141 (draft of IEC 801-6)
Immunity according to further standards
Transient voltage, IEC 255
NAMUR-prescription
Transient resistance, VDE 0160 §5.3.1.1.2
Over-voltage resistance (PULS standard)
Class B No degradation of performance 8kV direct discharge (level 4) 15kV air discharge (level 4) 10V/m (level 3) 4kV (level 4) 2kV (level 3) 2kV (level 4) cap. coupling 4kV (isolation class 4) 2kV (isolation class 4) 10V (level 3)
5kV Satisfied 750V / 1.3ms (class 2) 300V AC / 0.5s
+
24 5
Open-collector (I Open-collector. See diagram on page 3, Iout = 100%. @ 230V ACin. @ 110V ACin. @ 90V ACin.
+
30
See installation hints.
EN 50081-2 is also satisfied.
EN 50082-1 is also satisfied.
80MHz...1000MHz, ACin, Vout and signal lines: l = 1m. Coupled to ACin line. Coupled to DCout line. Coupled to Vout and signal lines. Common mode, unit on. Differential mode, unit on. 150kHz...80MHz.
Common mode, unit off.
Valid for total load range.
= 5mA), see figure on page 3.
max