AP336.122
3 Outputs
◆
19" Power Supply, 55 Watt
◆ High efficiency: 79%
◆ ACin wide range: 88...265V AC
DCin wide range: 105...300V DC
◆ 8 HP plug in width
◆ H15 standard pinout
◆ Power rail sharing
◆ Meets EMC standards
EN 50081-1 (EN 55022/B), EN 50082-2,
EN 61000-4, VDE 0160/2 and NAMUR
EN 60 950
Power Supply AP336.122
This triple-output power supp ly is optimized for highquality analogue applications (1A @ + 15V, 0,4A @ −
15V). The power unit uses a bridge-m ode wide-range
converter. It operates with high efficiency over the total input and output range. It operates over a wide
range (100 - 240V AC) w ithout switch over. Hold-up
time is over 200ms at 230V AC.
Load distribution is flexible and there is no minimum
load.
EMC compatibility is a major feature. It has low spurious noise, and noise suppression meets VDE 0871
class B. Noise immunity meets EN 61000-4 and VDE
0160 class 1, even at fu ll load. Over-voltage and overtemperature protection avoid problems even in extreme working environments
www.puls-power.de
See the web for current data sheet version:
Schematic:
Vout [DC] Iout Pout Features Order-No.
Vout1
Max. total power: 55W
"F" appended to Order No. means front panel 8 HP included and fitted.
Accessories: H15 connector, 6.3mm flat contacts:
Warranty: 2 years from date of delivery.
5.15V
2
3 −
7A
+15V 2.5A
15V 1A
H15 connector with soldering pins:
36W Wide input range,
37.5W PF, OTP, OVP
15W
AP336.122
ZP100
ZP120
Output
Voltage Vout1,2,3 Fixed.
Accuracy Vout1 max. ± 0.5% Tuning tolerance.
Vout2 +1.2% / −2%
Vout3 max. ± 2% @ Iout3 = 0.5A.
Sense lines None Not available.
Minimum load None Not necessary,
regulation details see page 2.
Output power Pout max. 55W Total power.
Noise, Ripple Vout1 max. 20mVpp 20Hz...200kHz.
Vout2/3 max. 10mVpp 20Hz...200kHz.
including spikes Vout1 max. 20mVpp 20Hz...20MHz.
Vout2/3 max. 10mVpp 20Hz...20MHz.
Over-voltage protection typ. 6.2V (Vout1) Threshold accuracy ± 8%.
Derating 1.5W/K +55° to +70°C Ta.
Operating indicator 1 green LED On the front, Vout1.
Isolation Vout to Vin SELV EN 60 950, VDE 0805 .
Vout1 to Vout2/3 max. 500V AC
All outputs are protected against open-circuit, short-circuit, and overload.
Mechanical: 8HP/3U board (DIN 41494),
Al/Mg alloy cover for component side,
plastic cover for bottom side,
LxWxH = 171.93 x 40.64 x 110mm (100),
the length includes the connector, see page 4.
Weight: App. 430g
Connector: H15 (DIN 41612), coding option,
max. load per pin 11A @ 70° C.
Input
Line input AC 100...240V AC Wide-range converter.
Range 88...265V AC Full spec.
⋅
Line input DC 275V DC Wide-range converter.
Range 105...300V DC Full spec.
⋅
Line frequency 47...63Hz DC or 400Hz, see page 2.
Input current rms max. 1.5A @ 88V AC.
Noise suppression EN 55 022/B 10kHz...30MHz, conducted.
Specifications are valid at 230V AC, unless otherwise stated. They are subject to change without prior
notice.
AP336.122 ◆ 3 Outputs ◆ 19" Power Supply ◆ 55 Watt
Output (continued) 5,15V +15V −15V
Voltage regulation:
Line regulation max. % 0.1 1 0.4
⋅
Load regulation stat.
⋅
Load regulation dyn.
⋅
Response time t
Temperature coefficient typ. %/K
⋅
∆
U
max. %
stat
∆
U
max. %
dyn
max. ms 5
s
Ripple max. mVpp 20 10 10
incl. spikes max. mVpp 20 10 10
⋅
Current limitation
Threshold typ. W 65
⋅
Short-circuit max. A 25 8 2.2
⋅
Start delay t
typ. s 1.2
Delay
On and off characteristic No overshoot
Load capacity max.
(continued)
Input
AC input range V AC 88...265
DC input range V DC 105...300
Derated DC range V DC 75...105
V DC 300...380
Frequency range Hz 47...63
Derated frequency range Hz 63...400
Inrush current max. A 20
Hold-up time min. ms 200
min. ms 15
Internal fuse 5x20mm T3.15A/250V
Input range selection Wide range
+
0.5/−0.7 +1.2/−2
±
7
±
0.015
µ
F 10,000 2,200 2,200
±
1.7
±
±
4
0.5
88...265V AC.
≥
Open-circuit to full load, Iout2 only valid @ Iout1
and Vin = 230V AC.
10%...90%...10% Load change, Iout2/3 only valid
≥
at Iout1
Till Vout is within tolerance.
20Hz...200kHz, ACnom, @ Iout = 100%.
20Hz...20MHz, ACnom, @ Iout = 100%.
Fixed, total power.
No foldback till Vout1=3V, below that periodic restarts.
After switch on.
Approximately monotonic.
Do not exceed for safe start up.
Full spec.
Full spec.
Different values for hold-up time, input current, ripple,
Pout; for details contact supplier (no start below 105V).
Full working, but air- and leakage distances not longer
than according to VDE 0805.
Full spec.
Increased leakage currents.
Wait min. 30s before switching on again (cold-start).
NAMUR standard met (Ta = +25° C).
@230V AC, Iout = 100%, see figure page 3.
@88V AC, Iout = 100%, see figure page 3.
In the L line, as per IEC 127/2-5. To replace, see page 4.
0.7 and Vin = 230V AC.
0.7A
Logic Functions
Power Fail signal PF Power fail
PF high, if ACin > 70V AC
⋅
Hold-up time
from power failure to PF-signal min. ms 200
⋅
min. ms 30
min. ms 10
from PF-signal min. ms 5
⋅
Electromagnetic Compatibility
Emissions according to EN 50081-1
Radio interference, EN 55011, EN 55022
⋅
Immunity according to EN 50082-2
Electrostatic discharge ESD, EN 61000-4-2
⋅
Radiated fields, EN 61000-4-3
⋅
Fast transients, EN 61000-4-4
⋅
Surge transients, EN 61000-4-5
⋅
Transient voltage, IEC 255
⋅
NAMUR-prescription
⋅
Transient resistance, VDE 0160 §5.3.1.1.2
⋅
Over-voltage resistance (PULS standard)
⋅
Class B
8kV direct discharge (level 4)
15kV air discharge (level 4)
10V/m (level 3)
4kV (level 4)
2kV (level 3)
2kV (level 4) cap. coupling
4kV (isolation class 4)
2kV (isolation class 4)
5kV
Satisfied
750V / 0.3ms (class 1)
300V AC / 0.5s
Open-collector signal (U
Open-collector.
@ 230V ACin.
@ 110V ACin.
@ 88V ACin.
Iout1 = 100%, Vout1 ≥ 4.75V.
EN 50081-2 is also satisfied
Conducted 10kHz...30MHz.
EN 50082-1 is also satisfied
To ACin, Vout and signal lines: length = 1m.
Coupled to ACin line.
Coupled to DCout line.
Coupled to Vout and signal lines.
Common mode, unit on.
Differential mode, unit on.
Common mode, unit off.
Valid for total load range.
= 30V, I
max
= 5mA).
max