This document and the information it contains is the property of Psion Inc. This document is not to be used,
reproduced or copied, in whole or in part, except for the sole purpose of assisting in proper use of Psion
manufactured goods and services by their rightful owners and users. Any other use of this document is prohibited.
Disclaimer
Every effort has been made to make this material complete, accurate, and up-to-date. In addition, changes
are periodically incorporated into new editions of the publication.
Psion Inc. reserves the right to make improvements and/or changes in the product(s) and/or the program(s)
described in this document without notice, and shall not be responsible for any damages including, but not
limited to, consequential damages, caused by reliance on the material presented.
Psion, the Psion logo, and the names of other products and services provided by Psion are trademarks of
Psion Inc.
®
Windows
and the Windows Logo are trademarks or registered trademarks of Microsoft Corporation in the
United States and/or other countries.
The Bluetooth® word mark and logos are owned by Bluetooth SIG, Inc. and any use of such marks by Psion
Inc. is under license.
All trademarks used herein are the property of their respective owners.
Return-To-Factory Warranty
Psion Inc. provides a return to factory warranty on this product for a period of twelve (12) months in accordance with the Statement of Limited Warranty and Limitation of Liability provided at:
www.psion.com/us/warranty.htm
The warranty on Psion manufactured equipment does not extend to any product that has been tampered
with, altered, or repaired by any person other than an employee of an authorized Psion service organization. See Psion terms and conditions of sale for full details.
Important: Psion warranties take effect on the date of shipment.
Service and Information
Psion provides a complete range of product support services and information to its customers worldwide.
Services include technical support and product repairs. To locate your local support services, please go to:
www.psion.com/service-and-support.htm
To access further information on current and discontinued products, please go to our Teknet site and log in
or tap on “Not Registered?”, depending on whether you have previously registered for Teknet:
http://community.psion.com/support
A selection of archived product information is also available online:
http://www.psion.com/products
TA B L E O F
CONTENTS
Table of ContentsTable of Contents
Chapter 1: Introduction
1.1About This Manual..................................................................................................3
This user manual describes the configuration, operation, and maintenance of the Psion Omnii HandHeld Computer.
Chapter 1: Introduction
provides a basic overview of the Omnii.
Chapter 2: Basic Operation
describes the steps required to get the Omnii ready for operation.
Chapter 3: Getting To Know Your Omnii
describes Omnii features, including how to charge and maintain the battery, the keyboard
features, the display, using the internal scanner, etc. This chapter also describes the Micro-
®
soft
Windows® Embedded CE 6.0 desktop, and how to change the appearance and actions
of the desktop from Windows Classic Shell to the PsionVU Shell.
Chapter 4: Configuration
describes the programs and applications accessed through two main areas from the Desktop
Start Menu: Programs and Settings>Control Panel. The software includes both Psion Soft-
ware Advantage and Microsoft programs, and details how to use them to configure the
Omnii, along with scanners/imagers, Bluetooth, etc. This chapter also details the PsionVU
program, which enables you to customize your computer settings.
Chapter 5: Accessories
describes the peripherals and accessories available for your Omnii computer.
Important: These statements provide particularly important instructions or additional infor-
mation that is critical to the operation of the equipment.
Warning:These statements provide critical information that may prevent physical injury,
equipment damage or data loss.
1.3Overview of the Omnii Hand-Held Computer
The Omnii Hand-Held Computer is a modular, industrial hand-held computer. A variety of options are available to suit applications in courier/delivery, field service, manufacturing facilities, material handling applications in warehouses, ports and yards, with a focus on real time wireless data transactions. Barcode input
methodologies are supported by a variety of available scanners. Optimization for specific operational environments is also supported with a wide range of peripheral options and carrying accessories.
The Omnii XT15f (Freezer Variant) combines modularity, customizability and performance with added technology to resist condensation for use in cold, condensing environments. For details, see “Omnii XT15f
Fre ez er Va ria nts” o n pa ge F-1.
Note: The Omnii Hand-Held Computer is a body worn device, and to maintain compliance with the
FCC RF exposure guidelines, use a Psion approved carrying case. Use of non-approved accessories may violate FCC RF exposure guidelines.
Note: For product specifications, refer to Appendix E: “Omnii Specifications”.
Model Variants
•Omnii RT15 Hand-Held Computer (rugged) - Model 7545XC
•Omnii XT15 Hand-Held Computer (extremely rugged) - Model 7545XT
Sitara AM37xx, ARM Processor 800 MHz (OMAP3® compatible)
Overview of the Omnii Hand-Held Computer
Chapter 1: Introduction
•Naurtech Browser
•Naurtech Terminal Emulation
•NetMotion Mobility XE VPN
Device Management and Utilities
•PsionVU
•Total Recall, TweakIt, Dr. Debug
•Mobile Control Centre (MCC)
- Easy configuration management and provisioning platform.
- Powerful remote control and troubleshooting functionality.
- Integrated real time geofencing and location services.
- Advanced device security, user authentication and lockdown features.
User Interface
•Colour/Touch Display 9.4 cm (3.7 in) diagonal
- VGA (640 x 480) Transflective
2
- High visibility option: superior sunlight visibility with 165 cd/m
- Extreme Duty option: withstands 1.25 Joule impact, superior low temperature operation (to -20° C/4° F), with 160 cd/m
2
brightness. Better abrasion resistance.
brightness
•Touchscreen
- Passive stylus or finger operation; pan and flick gestures supported
-Signature capture
•Keyboards
- Large selection of backlit keypads in both alpha and numeric formats. For a list of currently
available keyboard configurations, consult your Psion representative, or go to:
http://www.psion.com/us/products/handheld.htm
•Voice, Audio & Feedback
- High volume beeper: 95 dBA
- Integrated microphone and speaker
- Optional Push-to-Talk Speaker
•Walkie-talkie style Push-to-Talk – VoIP over WiFi or WWAN
•Vibration feedback
Wireless Connectivity
•Integrated Bluetooth® V2.0 + EDR
•Integrated 802.11a/b/g/n WiFi
•Bluetooth® coexistence
•CCX v4
•Optional SIRF III GPS Receiver
•Optional GPS/GPRS/EDGE WWAN radio
•Optional GPS/GPRS/EDGE with UMTS/HSPA+ WWAN radio
Note: 802.11b/g and Bluetooth are available simultaneously.
The following figures illustrate the main features of the Omnii — for detailed views, please see “Omnii Features” on page 11.
Psion Omnii Hand-Held Computer User Manual
5
Chapter 1: Introduction
Omnii XT15
59-Key ABC Keyboard
Omnii RT15
55-Key ABC Keyboard
Overview of the Omnii Hand-Held Computer
Figure 1.1 Omnii XT15 and RT15 Alphanumeric Variants
Psion Omnii Hand-Held Computer User Manual
6
Fig ure 1.2 Omn ii XT15 f Freezer Vari ant s
Alphanumeric
Numeric
Laser Aperture
Overview of the Omnii Hand-Held Computer
Chapter 1: Introduction
Figure 1.3 Bottom View (Docking Connector)
Figure 1.4 Top View (Scanner Window)
Psion Omnii Hand-Held Computer User Manual
7
Chapter 1: Introduction
This label is affixed below the sca nne r wind ow.
Regulatory Labels
1.4Regulatory Labels
Figure 1.5 Laser Warning Label
Warning:Using controls or adjustments or performing procedures other than those speci-
Figure 1.6 SE955 Laser Warning Label
Figure 1.7 SE965 and SE4500 Laser Warning Label
fied herein may result in hazardous radiation exposure.
The Omnii is powered by a Lithium-ion Smart Battery pack, 5000 mAh—Model ST3001.
Important: Before charging the battery, it is critical that you review the battery safety guide-
lines in the Omnii Hand-Held Computer Regulatory & Warranty Guide
(PN 8000191).
Battery packs shipped from the factory are charged to approximately 40% and must be fully charged prior
to use. Batteries can be charged using a variety of chargers and docking stations. For detailed information,
see “Battery Details” on page 21.
Replacing the Battery Pack
Important: Always switch the unit off before changing the battery (see “Switching the Omnii
On and Off” on page 15). However, assuming the default power saving parameters
and battery reserve level have not been altered, battery swap time is a minimum
of 4 minutes—you will not lose data if the battery is replaced within this time
frame.
Figure 2.6 Omnii Battery
Note: If you are using a docking station or an external power supply, you can insert an uncharged
battery and use the device while the battery charges.
Assuming the default power saving parameters and battery reserve level have not been altered, a battery
can be removed for up to 4 minutes without losing data. After 4 minutes the terminal may reboot.
Removing the Battery Pack
•If your unit is equipped with a hand strap, unhook it from the base of the battery.
•Press the two buttons at the sides of the compartment simultaneously, and slide the battery out.
Installing the Battery Pack
•Slide the charged battery with the contoured plastic facing you into the unit with the contacts matching position and the guide tabs moving into the corresponding slots at the base of the compartment.
Click both sides of the battery into place.
•If your computer is equipped with a hand strap, re-attach the clip to the slot at the base of the battery.
•Switch the unit on (see “Switching the Omnii On and Off” on page 15).
Psion Omnii Hand-Held Computer User Manual
14
2.5Switching the Omnii On and Off
Follow the instructions below for your Omnii. If your keyboard has a power button (55- and 66-key keyboards only), press that instead of the [FN]+[Enter/Power] key combinations described.
Switching the Omnii On
•Press and hold down the [Enter/Power] key for at least one second.
When the unit is turned off, normally it automatically enters a power-saving, “suspend” state. When the
Omnii is switched on from the suspend state, within a few seconds operation resumes in the screen in which
you were working prior to turning the computer off.
Important: If your Omnii fails to power up, consider the following troubleshooting options:
The battery may be overheated (>60C°), a non-Psion battery may be installed, or
the battery may have fallen below the configured Suspend Threshold. See “Suspend Threshold and Estimated Battery Backup” on page 89 for details.
To switch on the hand-held, you will need to replace the overheated battery.
However, if you supply AC power to the Omnii with a battery that falls below the
configured Suspend Threshold, the unit will
Switching the Omnii Off
•To switch off the Omnii, press the [FN] key and then press and release the [Enter/Power] button. The
Omnii will automatically enter the Suspend state.
Chapter 2: Basic Operation
Switching the Omnii On and Off
switch on.
Important: Turning off the hand-held does not result in a complete shutdown; rather, the unit
Important: If the word ‘FN’ is displayed underlined in the taskbar area at the bottom of the
enters a power-saving, “suspend” state. When the Omnii is turned on from
suspend state, operation resumes within a few seconds.
screen, this key is locked “on” and the Omnii will not switch off. Press the [FN]
key twice followed by [Enter/Power] to switch the Omnii off.
However, if you’ve set the mode to “Lock” (see “Keyboard One Shot Modes” on
page 78), the Omnii can be turned off even when the [FN] key is locked ‘on’.
2.6Resetting the Omnii
To perform a warm or cold reset, you can access the menu by going to Start>Shutdown. Alternatively you
can use the keyboard shortcuts described below.
Note: If your Desktop is switched to the PsionVU Shell (refer to “The PsionVU Desktop Shell” on
page 42), resetting the unit is done solely by use of the keyboard shortcuts.
Psion Omnii Hand-Held Computer User Manual
15
Chapter 2: Basic Operation
Pin 6 Pin 5
Performing a Warm Reset
2.6.1Performing a Warm Reset
During a warm reset, running programs are halted. The contents of the file system, RAM Disk, Flash Disk,
and the registry are preserved.
•Press and hold down the [FN] key and the [Enter/Power] key simultaneously for a minimum of
four seconds.
Note: You need to reset your Omnii after configuring the radio by switching between Windows
Zero Config and WiFi Config.
2.6.2Performing a Cold Reset
A cold reset reinitializes all hardware. All RAM including the RAM Disk is erased. Non-volatile storage such
as the Flash Disk is preserved, as is the file system.
To execute a cold reset:
•Press and hold down the [SYM] key, the [FN] key, and the [Enter/Power] key, simultaneously for a
minimum of four seconds.
Note: As part of the normal Windows Embedded CE cold boot process, the screen may go blank for
a few seconds after the splash screen loading bar reaches the end. The desktop is displayed
after a few moments.
2.6.3Performing a Clean Start
A clean start returns the Omnii to factory settings, flushes the registry keys, and deletes volatile storage
and the file system. The Flash Disk is preserved.
•Press and hold down the [FN] key, the [Enter/Power] button and the [SCAN] key simultaneously for a
minimum of six seconds.
The Omnii displays the Boot to BooSt menu.
•On an alpha keyboard, type .clean.
•On a numeric keyboard, type .25326.
2.6.4Boot to BooSt
If you choose Boot to BooSt, the BooSt menu is loaded.
•Press and hold down the [FN] key, the [Enter/Power] button and the [SCAN] key for a minimum of
four seconds.
•Press [1] to launch the OS.
2.6.5Performing a Hard Reset
Important: This procedure is recommended as a last resort, when all other methods fail.
To execute a hard reset:
•Remove the battery.
•Using a coin, or other conductive item, connect pins 5 and 6 of the battery contacts for at least
six seconds.
•Replace the battery and power Omnii on. The terminal will boot as if from a cold reset.
Psion Omnii Hand-Held Computer User Manual
16
2.7Attaching Carrying Accessories
Psion recommends that a carrying accessory — a hand strap — be installed on the Omnii before use. For detailed information, please see “Carrying and Protective Accessories” on page 136.
2.8Calibrating the Touchscreen
Note: The touchscreen function can be turned off (see “Touch” on page 110).
The Omnii touchscreen feature is factory-calibrated and ready-to-go; however, over time the touchscreen's
operating parameters may change, and it may need to be recalibrated for correct operation. Refer to “Calibrating the Touchscreen” on page 27 for details.
2.9Imager and Scanner Options
If your Omnii is equipped with an internal imager or scanner, please review the relevant sections:
Appendix B: “Imager & Camera Settings” and Appendix C: “Scanner Settings” for details.
Appendix D: “Internal Imager & Scanner Specifications” lists their current model numbers, descriptions,
and specifications.
Chapter 2: Basic Operation
Attaching Carrying Accessories
2.10Connectivity
For information on connecting the Omnii to a PC, please refer to “Data Transfer between Omnii and a PC”
on page 67
The Omnii contains an integrated 802.11a/b/g/n radio module. The Wi-Fi Config application is used to config-
ure the radio for one or more wireless network profiles. To configure the radio, follow the steps outlined
under the heading “Wi-Fi Config” on page 123.
To co n f i gure y o u r Bluetooth settings, please go to “Bluetooth® Setup” on page 56.
If you have a GPS (Global Positioning System) module, you can choose from a set of GPS profiles built into
the modem and set up AGPS (Assisted Global Positioning System). See “GPS (Global Positioning System)
Settings” on page 72.
The Omnii is available with one of the following Wireless WAN radio options: the Cinterion MC75i EDGE and
the Cinterion PH8-P HSPA+. See Appendix E: “Wireless Radios” for full specifications. With either of these
radios and a SIM card, you can wirelessly transfer data (see Appendix G: “Wireless Wide Area Network
(WWAN) Settings”), and you can use the Omnii voice option to place phone calls (see below, Section 2.12:
“Voice Communication”).
To see the radio specifications, please go to “Wireless Radios” on page E-6.
2.11Data Transfer
Data transfer options vary slightly depending on the type of operating system installed in your PC. Various
options exist depending on whether you are using Windows XP or earlier, Windows Vista
later. For connection details, please refer to “Data Transfer between Omnii and a PC” on page 67.
2.12Voice Communication
®
, Windows 7 or
If the MC75i EDGE or the Cinterion PH8-P HSPA+ WWAN radio modem is installed and enabled, the Phone icon and the GSM signal strength icon will appear automatically on the taskbar. For details on using your
Voice options, please refer to “Voice – Using the WWAN Phone Dialer” on page 117.
Note: The voice option is not available in North America for the MC75i EDGE radio.
3.7.5 Operating One Dimensional (1D) Internal Laser Scanners...........................34
3.7.6 Operating Internal Two Dimensional (2D) Imagers...............................34
3.8 Windows Embedded CE 6.0 ..................................................35
3.8.1 Navigating in Windows Embedded CE and Applications............................35
3.8.1.1 Navigating Using a Touchscreen....................................35
3.8.1.2 Navigating Using the Keyboard.....................................35
3.8.2 The Windows Classic Shell Startup Desktop...................................36
3.8.2.1 The Taskbar................................................37
3.8.2.2 The Start Menu..............................................38
3.9 The PsionVU Desktop Shell...................................................42
3.9.1 Restoring the Windows Classic Shell.......................................44
3.10 General Maintenance......................................................45
OMNII
Psion Omnii Hand-Held Computer User Manual
19
3.10.1 Caring for the Touchscreen ............................................45
3.10.2Cleaning the Omnii .................................................45
20
Psion Omnii Hand-Held Computer User Manual
3.1Operating System
•Microsoft® Windows® Embedded CE 6.0
3.2Battery Details
Omnii Hand-Held Computers are powered by a lithium-ion battery pack, Model ST3001.
Please see the following sections for detailed battery information:
•Installation: “Preparing the Omnii for Operation” on page 14.
•Calibration and power settings: “Power Properties” on page 88.
•Chargers and docking stations: Chapter 5: “Accessories”.
•Specifications: “Lithium-ion Smart Battery 5000 mAh (ST3001)” on page E-5.
•Contact pinout: “Omnii Battery Contacts” on page A-6.
3.2.1Battery Safety
Chapter 3: Getting To Know Your Omnii
Operating System
Important: Before attempting to install, use, or charge the battery pack, it is critical that you
review and follow the important safety guidelines in the quick reference guide
entitled the Omnii Hand-Held Computer Regulatory & Warranty Guide,
PN 8000191.
3.2.2Battery Swap Time
Assuming the default power saving parameters and battery reserve level have not been altered, battery
swap time is a minimum of 4 minutes—you will not lose data if the battery is replaced within this time frame.
To protect data, the safest place to store data is on a microSD memory card or externally to the device on a
USB memory stick or on a PC. You can also save data in the “Flash Disk” partition of the file system.
Refer to “Suspend Threshold and Estimated Battery Backup” on page 89 for details about reserving
battery power for data backup purposes.
The Suspend Threshold adjustment in the Power Properties tab allows you to determine the battery capacity at which the Omnii will be shut down. If left at the default value, Maximum Operating Time, the unit will
run until the battery is completely empty; the RAM is only backed up for a short period of time. If you
choose Maximum Backup Time, the Omnii shuts off with more energy left in the battery so RAM can be
backed up for a longer period of time.
Important: If your Omnii fails to power up, consider the following troubleshooting options:
The battery may be overheated (>60C°), a non-Psion battery may be installed, or
the battery may have fallen below the configured Suspend Threshold. See “Suspend Threshold and Estimated Battery Backup” on page 89 for details.
To switch on the hand-held, you will need to replace the overheated battery.
However, if you supply AC power to the Omnii with a battery that falls below the
configured Suspend Threshold, the unit will
switch on.
3.2.3Charging the Battery
Batteries shipped from the factory are charged to approximately 40% of capacity. Lithium-ion battery
packs must be fully charged before use. These batteries can be charged with a variety of chargers and
docking stations. For detailed information on these accessories, please see Chapter 5: “Accessories”.
Psion Omnii Hand-Held Computer User Manual
21
Chapter 3: Getting To Know Your Omnii
36-Key Numeric 123 Keyboard
59-Key Alpha ABC Keyboard
[FN] Modifier Key
[SYM] Key
[SHIFT] Modifier Key
[SCAN] Key
[Enter/Power] Key
[Windows] Key
The Keyboard
Normally it takes 3 to 4 hours to charge a battery. The Omnii intelligent charging system protects the
battery from over-charging by terminating the charge process when the battery is at maximum capacity.
Table 3.1 Omnii Internal Battery Charging Times at 25°C (77°F)
Important: To avoid damaging the battery, chargers will not begin the charge process until
the battery temperature is between 0°C to 40°C (32°F to 104°F).
3.3The Keyboard
The Omnii offers a wide variety of Alpha and Numeric keyboard layouts.
See http://www.psion.com/us/products/handheld.htm for a list of available configurations. Most of the keys
on these keyboards operate much like a desktop computer. Where a key or key function is not consistent
with the PC keyboard, those differences are described in the following sections.
The Omnii is equipped with either an [Enter/Power] key or Power button (55- and 66-key keyboards only)
that allows you to switch the unit on and to shut down the unit to Suspend mode. For details refer to
“Switching the Omnii On and Off” on page 15.
There are a number of modifier keys that provide access to additional keys and system functions, as described in “Modifier Keys” on page 24.
The [Blue/FN] modifier key provides access to additional keys and system functions. These functions are
colour coded in blue print above the keyboard keys.
Fig ure 3.1 Keyboard Layouts
22
Psion Omnii Hand-Held Computer User Manual
The Power Button (55-Key and 66-Key Keyboards only)
[End] key
[Talk] key
55-Key Alpha ABC Keyboard with phone
Power button
The [Power] button in the upper right corner of the keyboard switches the unit on and off.
3.3.1Regular Keys
Chapter 3: Getting To Know Your Omnii
Regular Keys
The [Enter] Key
The [Enter] key is used to execute the usual Enter keyboard functions, and on some units to also power the
unit on and off (for details refer to “Switching the Omnii On and Off” on page 15).
Note: 55-key and 66-key keyboards are equipped with a Power button. For these keyboards, the
[Enter] key does not switch the unit on or off.
The [SHIFT] Key
The [SHIFT] key is used to display uppercase alpha characters and to provide access to other symbols and
functions on the numeric keyboards. Press the [SHIFT] key to turn the shift state 'on' (it will be represented
by an up arrow in the taskbar), then press another key to access the shifted function of that key.
Press the [SHIFT] key twice to lock the shift state on (the up arrow in the taskbar will be underlined). Press
[SHIFT] again to turn the shift state off.
To access CAPS LOCK mode, press [FN] + [SHIFT]. In this state, if you press a numeric key, the number is
displayed rather than the normal shifted function of that key. Press [FN] + [SHIFT] again to turn the CAPS
LOCK mode off.
The Arrow Keys
The [Arrow] keys are located near the top of the keyboard, and are represented on the keyboard as triangles pointing in different directions. The [Arrow] keys move the cursor around the screen in the direction of
the arrow: up, down, left and right. The left arrow key should not be confused with the [BACKSPACE] key
which is depicted as a left arrow. The cursor is the flashing box or underline character that indicates where
the next character you type will appear.
The [BACKSPACE/DEL] Key
The [BACKSPACE] key (represented on the keyboard as an arrow pointing left) moves the cursor one character to the left, erasing the previous key stroke.
The [DEL] key ([FN] +[BACKSPACE]) erases the character at the current cursor position.
The [CTRL] and [ALT] Keys
The [CTRL] and [ALT] keys modify the function of the next key pressed and are application dependent.
Pressing either key twice locks it 'on' (it appears underlined on the Taskbar). Pressing the key once again
unlocks it.
Psion Omnii Hand-Held Computer User Manual
23
Chapter 3: Getting To Know Your Omnii
Modifier Keys
The [TAB] Key
Typically, the [TAB] key moves the cursor to the next field to the right or downward.
The [ESC] Key
Generally, this key is used as a keyboard shortcut to close the current menu, dialog box, or activity.
The [SPACE] Key
The [SPACE] key is represented on the keyboard by a long, low horizontal line contained by a small vertical
line on each side. Pressing this key inserts a blank space between characters. In a Windows dialog box,
pressing the [SPACE] key enables or disables a check box.
The [SCAN] Key
The Omnii is equipped with a single [SCAN] key on the keyboard and an extra [SCAN] button located on the
left side of the unit. [SCAN] keys activate the scanner beam. For units that do not have internal scanners,
these keys can be remapped to serve other functions.
3.3.2Modifier Keys
The [SHIFT], [CTRL], [ALT], [FN] and [SYM] keys are modifier keys that change the function of the next key
pressed.
The [SHIFT], [CTRL] and [ALT] keys operate much like a desktop keyboard except that they are not chorded
(two keys held down simultaneously). The modifier key must be pressed first followed by the key whose
function you want modified.
[SHIFT] and [FN]
The [SHIFT] and [FN] modifier keys provide access to additional keys and system functions. The functions
related to these modifier keys are colour-coded in white and blue print respectively above the keyboard
keys, dependant on your keyboard format.
[SYM]
Note: When using the Mobile Devices SDK Developers' Guide (PN 8100016), note that the [SYM]
key is interchangeable with the [ORANGE] key.
The Symbol [SYM] modifier key is represented on the keyboard by the characters ‘SYM’ and provides
access to commonly used symbolic characters. Pressing the key brings up the Symbol soft input panel (SIP)
onscreen keyboard, with symbols mapped to each key. If you wish to adjust the settings for the pop-up
screen (e.g. time of delay before screen appears, etc.), modify the file softinputpanel.xml, located in the
Windows folder.
Note: Modifier keys are remapped in Control Panel, and the Symbol SIP will automatically show
and use the new mappings after the next reboot.
The onscreen keyboard corresponds to the specific keyboard on your Omnii—either numeric
or alphanumeric.
24
Psion Omnii Hand-Held Computer User Manual
Figure 3.2 Symbol Soft Input Panels
36-KEY Numeric Keyboard
59-KEY Alpha Keyboard
[SPACE] Key
Internet Browser Keys
3.3.2.1Activating Modifier Keys
When a modifier key is pressed, it is shown in the softkey bar at the bottom of the screen, making it easier
to determine whether a modifier key is active. For example, if the [CTRL] key is pressed, Ctrl is displayed at
the bottom of the unit screen. Once the next key is pressed, the modifier key becomes inactive and disappears from the taskbar.
Chapter 3: Getting To Know Your Omnii
Function Keys and Macro Keys
3.3.2.2Locking Modifier Keys
When a modifier key is pressed twice, it is ‘locked’ on. A ‘locked’ modifier key is displayed in underlined
letters in the taskbar. For example, pressing the [FN] key twice locks it on—it is displayed as an underlined
blue ‘FN’ in the taskbar at the bottom of the computer screen. The same is true of the [SYM] key, which is
shown as an underlined orange ‘SYM’ in the taskbar.
The locked modifier key will remain active until it is pressed a third time to unlock or turn it off. Once a modifier key is unlocked, the underline representation at the bottom of the screen is no longer displayed.
Note: The locking function of the modifier keys can be changed so that pressing a key once will
lock the key ‘on’.
If you disable the ‘One Shot’ function of the key, pressing it once will lock the key ‘on’. Press-
ing the same key a second time will unlock or turn it ‘off’. Refer to “Keyboard One Shot
Modes” on page 78 for details.
3.3.3Function Keys and Macro Keys
In addition to the standard keyboard functions (see “The Keyboard” on page 22), the Omnii supports function keys and macro keys.
All function keys and macro keys can be custom defined for each application. The Open TekTerm application utilizes these keys (for detailed information, see the Open TekTerm Software User Manual,
PN 8000073).
3.3.3.1Function Keys
Function keys perform special, custom-defined functions within an application. These keys are accessed by
pressing one of the dedicated function keys on the keyboard, or through the appropriate [SHIFT] or [FN]
key sequence, depending on the keyboard variant being used.
Alphanumeric Keyboard Function Keys
The Alphanumeric keyboards are equipped with up to thirty function keys, including those function keys
that are colour-coded in blue print above the alpha keys or function keys (depending on your keyboard).
To access the blue function keys, press the [FN] key followed by the appropriate alpha or function key.
Psion Omnii Hand-Held Computer User Manual
25
Chapter 3: Getting To Know Your Omnii
Numeric Keyboards — Accessing Alpha Keys
Function keys [F1] through [F24] can be used with the Windows Embedded CE operating system or another
application. The additional function keys, [F25] through [F30] along with the macros, are not used as part
of the Windows Embedded CE operating system.
Numeric Keyboard Function Keys
The Numeric keyboards are equipped with up to 24 function keys, including those function keys that are
colour-coded in white print above the function keys. Function keys F25 through F30 can only be accessed
by remapping another key to that function.
To access the white function keys, press the [SHIFT] key followed by the appropriate function key.
3.3.3.2Macro Keys
Important: Refer to “Keyboard Macro Keys” on page 79 for details about creating macros.
Several of the Omnii keyboards are equipped with a series of macro keys that can be programmed to
replace frequently used keystrokes, along with the function of executable keys like the [Enter/Power] key,
the [BACKSPACE] key, any function key and arrow key, etc.
59-Key Alphanumeric Keyboard Macro Keys
These keyboards have six macro keys: [M1] to [M6], located on the S to X keys (second-last row of keys).
To access a macro key, press the [FN] key followed by the macro key.
36-Key Numeric Keyboard Macro Keys
These keyboards are equipped with five macro keys: [M1] to [M5]. These keys are colour coded in blue print
above function keys [F1] to [F5].
To access a macro key, press the [FN] key followed by the macro key.
3.3.4Numeric Keyboards — Accessing Alpha Keys
On the Numeric Omnii keyboards, all alphabetic characters are printed on the unit plastic in blue typeface
above the keys. Alpha characters are accessed by pressing the [FN] modifier key, then pressing another key
on the keyboard.
The Alpha Modified Numeric 789 keyboard has each blue alphabetic character assigned as a single [FN]shifted character on individual keys. An indicator in the left corner of the taskbar displays the currently selected character.
The Numeric 123 keyboards have telephone-style alphabetic keys, with the blue alphabetic characters
located in groups of 3 or 4 above each of the numeric keys. To access characters on these keyboards, a few
extra steps are needed, as described below.
Choosing a Single Alpha Character
Note: The following examples assume that the [FN] key is enabled as ‘Lock’ mode in the ‘One Shot’
screen (accessible through the Control Panel Keyboard icon). In ‘Lock’ mode, pressing the
[FN] key once locks it ‘on’. Refer to “Keyboard One Shot Modes” on page 78 for details.
The examples below illustrate how to access A, B and C, all of which are printed in blue characters above
the numeric key [2]. The letters you choose appear in the softkey bar as you press the numeric key, providing a visual indicator of which letter will be displayed on the screen.
To choose the letter ‘a’:
•Press the [FN] key, and press the numeric key [2].
•Press the [FN] key again to unlock or turn it off.
To choose the letter ‘b’:
•Press the [FN] key, and press [2] twice.
•Press the [FN] key again to unlock or turn it off.
To choose the letter ‘c’:
26
Psion Omnii Hand-Held Computer User Manual
•Press the [FN] key, and press [2] three times.
•Press the [FN] key again to unlock or turn it off.
Note: Keep in mind that there is a timeout of one second between key presses when sequencing
through the alphabetic characters on a key. If you pause longer than one second between
key presses, the alphabetic character that is displayed at that time will be entered.
Selecting Uppercase Letters
To display a single capital letter, press the [SHIFT] key first, then the letter you want.
To access CAPS LOCK mode, press [FN] + [SHIFT]. In this state, if you press a numeric key, the number is
displayed rather than the normal shifted function of that key. Press [FN] + [SHIFT] again to turn the CAPS
LOCK mode off.
3.3.5The Keypad Backlight
The intensity of the keypad backlight and the conditions under which this backlight is activated can be configured using the Keyboard icon in the Windows Embedded CE Control Panel. The behaviour of the keypad
backlight is tailored in the Keyboard Properties dialog box. Refer to “Keyboard Backlight” on page 78 for
details about this option.
Note: Keep in mind that this option may be restricted to supervisory use only.
Chapter 3: Getting To Know Your Omnii
The Keypad Backlight
3.4The Display
The Omnii is equipped with display backlighting to improve character visibility in low light conditions. The
backlight switches on when a key is pressed.
3.4.1Adjusting the Display Backlight
The behaviour of the display backlight and the intensity of the backlight can be specified in the Display
Properties dialog box in the Control Panel.
Note: Refer to “Backlight” on page 68 for details about the Display Properties dialog box.
3.4.2Calibrating the Touchscreen
If your Omnii touchscreen has never been calibrated, or if you find that the stylus pointer is not accurate
when you tap on an item, use the Stylus Properties dialog box in the Control Panel to recalibrate the screen.
•In the Control Panel, choose the Stylus icon to display the Stylus Properties window.
•Select the Calibration tab, and then choose the Recalibrate button.
Psion Omnii Hand-Held Computer User Manual
27
Chapter 3: Getting To Know Your Omnii
3. Radio Status
4. Scanner Status
1. Battery Charge Status
2. Operating System Status
1
2
3
4
Indicators
•Follow the directions on the calibration screen to calibrate the screen.
3.5Indicators
The Omnii uses LEDs (Light Emitting Diodes), onscreen messages, vibrations, and audio tones as indicators.
3.5.1LEDs
The Omnii is equipped with four coloured LEDs. This section outlines what these LEDs indicate.
Important: If an LED is illuminated in red, the operator should be cautious as this generally
indicates an abnormal operating condition or active laser emission.
Figure 3.3 LED Status Indicators
28
Psion Omnii Hand-Held Computer User Manual
3.5.1.1Battery Charge Status LED
The far left LED is reserved for battery charge status. This indicator is active even when the hand-held is inserted in a docking station (and in suspend mode) so that the charge status of the battery can be
detected easily.
Table 3.2 Battery Charge LED Behaviours
Charge LED BehaviourFunction
OFFExternal power not detected.
Solid GreenBattery charging complete.
Flashing GreenCharge in progress.
YellowCell temperature out of range for charge.
Solid RedUnable to charge battery.
3.5.1.2Operating System Status LED
The second LED indicates system notifications and operating system status. It is also available for userloaded custom Windows Embedded CE applications.
Tabl e 3. 3
Chapter 3: Getting To Know Your Omnii
LEDs
Operating LED BehaviourFunction
OFF when unit is in Suspend or Shutdown.Normal operating status.
Solid YellowThe unit is powering on.
Fast Flashing YellowThe unit is entering Suspend mode.
Flashing YellowThis LED is controlled by the Microsoft NLED api.
3.5.1.3Radio Status LED
The third LED from the left indicates that the GPS radio is enabled or that the WWAN radio is enabled.
Tabl e 3.4
Radio Traffic LED BehaviourFunction
OFFThe radio is disabled.
Slow Flashing BlueThe radio is enabled and active.
3.5.1.4Scanner Status LED
The fourth (far right) LED indicates scanner status.
Tabl e 3. 5
Scan LED BehaviourFunction
OFFThe scanner is not in use.
Solid Red during scanScan in progress.
Solid Green after decode
OFF when scan ended
Flashing RedUnsuccessful scan.
Successful scan.
Psion Omnii Hand-Held Computer User Manual
29
Chapter 3: Getting To Know Your Omnii
GoodNo Radio
Reception
Weak
ReceptionLink
Onscreen Indicators
3.5.2Onscreen Indicators
The taskbar at the bottom of the screen displays a variety of system status indicators, including the Input
Panel button if you have chosen to show that option in the Tas k b ar and St a r t M enu settings.
Fig ure 3. 4 Taskb ar
The taskbar changes dynamically, and only those icons that are applicable are displayed. For example, if a
radio is not installed in your Omnii, the radio signal icon is not displayed in the taskbar.
®
Windows
Start Button
If you are using the touchscreen, you can either tap the Windows icon at the bottom left of the screen, or
press the [Windows] key to display the Start Menu, and then tap on the desired application.
Modifier Key Indicators
[SHIFT], [CTRL], [ALT], [FN] and [SYM] are modifier keys that have onscreen indicators to show when a key
is active or locked. If a modifier key is pressed once to activate it, the key is displayed in the taskbar, for example, pressing the [FN] key once displays ‘FN’ in the taskbar. If a modifier key is pressed twice, it is ‘locked
on’ and the onscreen indicator is displayed with underlined letters in the taskbar, for example, pressing [FN]
twice displays ‘FN’ in the taskbar.
Power
The battery shaped icon displayed in the taskbar provides quick access to the charge state of the battery.
Tapping on the icon once will show the percentage charge left in the battery. Tapping on the icon twice
opens the Power Properties menus (see “Power Properties” on page 88), where you can set the low battery
warnings levels, and time to enter Suspend.
If the Omnii is using external AC power, an AC icon is displayed in the taskbar.
802.11 Radio Signal Quality
Increasing radio signal quality is represented by longer, filled bars within this icon.
WWAN Radio Signal Quality
Wireless WAN icons in the taskbar indicate the status of your wide area network connection. For details, see
“Taskbar Icons” on page G-3.
30
Psion Omnii Hand-Held Computer User Manual
Docking Device
Combo Charger &
Combo Docking Station
Quad Docking StationPowered Vehicle Cradle, Desktop Dock
& Snap Module
OPEN
LOCK
SD Cover
microSD Card Slot
SIM Card Slot
When a hand-held is inserted in a docking station, charger or cradle, an associated icon appears in
the taskbar.
Bluetooth RadioThis icon displayed in the taskbar represents the installed Bluetooth radio.
Input Panel
You can tap the Input Panel icon to activate the soft keyboard application.
3.5.3Audio Indicators
The Omnii supports several audio options, including Bluetooth. The optional rear speaker can be used for
system (Windows) sounds and .wav files. When a rear speaker is absent, those sounds are routed to the
front receiver. The beeper provides a variety of sounds and can be configured to emit a sound when a key is
pressed, a keyboard character is rejected, scan input is accepted or rejected, an operator’s entry does not
match in a match field or the battery is low. The volume rocker button is located on the left side of the
hand-held. Information on configuring sounds is detailed in “Volume & Sounds Properties” on page 122.
Chapter 3: Getting To Know Your Omnii
Audio Indicators
3.5.4Vibrations
You can set the Omnii to vibrate when a successful or unsuccessful barcode scan is performed. See “Scanners”, page 97.
3.6Inserting the microSD Card and SIM Card
There are two slots available in the battery compartment—the lower slot is provided for a microSD (Secure
Digital) card, which provides additional non-volatile memory to your Omnii, and the upper slot is for a SIM
(Subscriber Identity Module) card, which allows access to the Voice option, access to the Internet, and so
on.
3.6.1Inserting the Cards
•Switch off the power to the Omnii.
•Remove the battery.
•Use a Phillips screwdriver to remove the SD cover screw. Flip the cover open or remove it.
For a microSD ca rd:
•Slide the microSD card door to the left to unlock it. Flip it open.
Psion Omnii Hand-Held Computer User Manual
31
Chapter 3: Getting To Know Your Omnii
icro
M
OPEN
LOCK
Scanners and Imagers
•Slide the microSD card into the guides on the SD card door.
•Close the microSD card door, and slide it to the right to lock it.
For a SIM ca rd:
•Slide the SIM card metal door latch to the right to unlock it, then flip the door open.
•Slide the card into the guides on the SIM card door.
•Swing the hinged door back down into place, and slide the metal door latch to the left to lock it.
3.7Scanners and Imagers
Important: It is critical that you review the “Laser Warnings” in the Omnii Hand-Held Compu-
Note: To enable a newly-installed imager or scanner, press and hold down the [FN] key and the
The Omnii supports a wide range of scanner options to address a variety of user application requirements.
Refer to the following sections for detailed information:
•Scanner list and specifications: Appendix D: “Internal Imager & Scanner Specifications” .
•Configuration: “Scanners” on page 97 and “Manage Triggers” on page 84.
•“Scanning Techniques” on page 33 outlines the mechanics of a successful scan.
•“Scanner Status LED, Sounds, and Vibrations” on page 33 details how to interpret whether or not a
barcode has been successfully scanned.
•Imager Settings: Appendix B: “Imager & Camera Settings”.
•“Troubleshooting” on page 33 provides some helpful suggestions should the scan fail.
Scanner types include:
•Long Range: reads large 1D barcodes (55 mil) at long distances (up to 3m).
•Standard Range/High Performance: reads damaged or low contrast regular 1D barcodes (5 - 55mil) at
medium distances (up to 1m).
•Extended Range: reads regular 1D barcodes (5 - 55mil) at short to medium distances (1m), as well as
large 1D barcodes (e.g. 55 mil) at long distances.
•1D Imager: reads regular 1D and PDF417 barcodes at short to medium distances.
ter Regulatory & Warranty Guide (PN 8000191) before using any of the scanners
described in this chapter.
For detailed scanner specifications and decode zone tables, refer to Appendix D:
“Internal Imager & Scanner Specifications” .
[Enter/Power] key simultaneously for a minimum of three seconds.
If your unit has a [Power] button, press and hold down the [FN] key and the [Power] button
for a minimum of three seconds.
32
Psion Omnii Hand-Held Computer User Manual
•EA11 2D imager: reads 1D and 2D barcodes including damaged and low contrast regular 1D barcodes;
smallest barcode at 5 mil with a minimum read distance to 2.8 in. / maximum read distance of 5.1 in.;
largest barcode at 40 mil with a minimum read distance of 3.1 in. / maximum distance of 32.4 in.
•EA20X 2D imager: reads 1D and 2D barcodes including damaged and low contrast regular 1D barcodes;
shortest barcode at 6 mil with a minimum read distance of 6.1 inches / maximum read distance of 9.1
inches; longest barcode at 40 mil with a minimum read distance of 5.1 inches / maximum read distance
of 49.2 inches.
•SE4600LR imager: captures digital images for transmission to a decoder to decode a barcode of any
format supported by the decoding software. Uses laser aiming, LED illumination, and CMOS sensors to
capture barcode images over an extended range and under a wide variety of lighting conditions.
3.7.1Basic Scanner Operations
•Turn the hand-held on. Wait until the unit has booted up completely.
•Aim at the barcode and press the scan key or the trigger. A scan beam and a warning indicator appear
until a successful decode is achieved or six seconds have elapsed.
3.7.2Scanning Techniques
•Hold the scanner at an angle. Do not hold it perpendicular to the barcode.
•Do not hold the scanner directly over the barcode. In this position, light can reflect back into the scanner’s exit window and prevent a successful decode.
•Scan the entire barcode. If you are using a 1D or PDF laser scanner, make certain that the scan beam
crosses every bar and space on the barcode, including the margins on either end of the symbol.
•If you are using a 2D imaging scanner, make certain the red, oval shaped framing mark is centered
within the barcode you want to scan.
•When using imaging scanners, do not move the scanner while decoding the barcode. Movement blurs
the image.
•Hold the scanner farther away for larger barcodes.
•Hold the scanner closer for barcodes with bars that are close together.
Chapter 3: Getting To Know Your Omnii
Basic Scanner Operations
3.7.3Scanner Status LED, Sounds, and Vibrations
The scanner LED (the far right LED) indicates whether or not your scan is successful. The LED behaves as
follows:
•Scan In Progress: scan LED displays solid red colour.
•Successful Scan: scan LED displays solid green colour and turns off when the scan is ended.
•Unsuccessful scan: scan LED flashes red.
A barcode icon appears on the screen during a scan. While the scanner beam is active, the onscreen
message states: SCANNING. If you want to turn off the onscreen message, disable the “Scan Indicator” parameter in the Control Panel>Scanners>Options>Display menu.
When the scan is successful, the barcode data is displayed on the screen until the scan button (or pistol trigger) is released, but only if the “Scan Result” parameter is turned on in the Control Panel>Scanners>Op-tions>Display menu.
You can also enable sounds and vibrations to indicate good and bad scans by enabling those options in the
Control Panel>Scanners>Options>Display menu.
3.7.4Troubleshooting
If the scanner is not working, investigate the following:
•Is the unit on?
•Check that the barcode symbology being scanned is enabled for the hand-held you are using. Check
any other parameters that affect the scanning procedure or the barcode.
•Check the barcode to make sure it is not damaged. Try scanning a different barcode to verify that the
problem is not with the barcode.
•Check that the barcode is within the proper range.
•Does the hand-held display the warning without scanning? This suggests a hardware problem in the
hand-held.
Psion Omnii Hand-Held Computer User Manual
33
Chapter 3: Getting To Know Your Omnii
Operating One Dimensional (1D) Internal Laser Scanners
•Is the laser beam scanning across the barcode?
•Once the scan beam has stopped, check the scanner window for dirt or fogging.
3.7.5Operating One Dimensional (1D) Internal Laser Scanners
•Turn the hand-held on. Wait until the unit has booted up completely.
Important: If an aiming dot is available on the installed scanner, the dot will be enabled for a
•Aim at the barcode and press the scan key or the trigger. A scan beam and a warning indicator appear
until a successful decode is achieved or six seconds have elapsed.
configurable time period (including off), after which normal scanning begins. Refer
to “Dot Time (msec)” on page -5 for details.
Double-clicking the trigger will override the aiming delay and initiate an immediate scan. Note that the aiming dot is standard on long-range and high visibility
internal scanners.
3.7.6Operating Internal Two Dimensional (2D) Imagers
An imager scanner takes a snap shot of a single barcode or multiple barcodes (at one time). It can find a
barcode regardless of its orientation—that is, even a barcode printed at a 45 degree angle to the hand-held
will be decoded successfully.
Note: When scanning multiple barcodes, ensure that all of the desired barcodes are within the
field of view of the scanner. It is possible that even when all barcodes are within the field of
view, not all of them will be decoded. Only successfully decoded barcodes are passed to the
application program. The application program then issues a warning, asking that you scan
the missing barcodes.
When scanning a single barcode, ensure that only the desired barcode is within the field of
view of the scanner.
Because imager scanners generally have a shorter depth of field than laser scanners, some practise may be
required to find the optimal distance from the types of barcodes being scanned. Although the imager includes illumination LEDs, ambient light will help the imager decode the barcodes, especially if the barcode
is far from the hand-held.
34
Important: Keep in mind that the imager scanner is a camera, and the LED illumination is a
flash. Glare can be an issue on reflective media such as plastic coated barcodes,
just as glare is an issue for photographers. When pointing at a shiny surface,
either shift the barcode to the side or top, or angle the barcode so that the glare
reflects away from the imager scanner.
Most imagers take several ‘snap shots’ of the barcode in order to decode it. It is
normal for the LEDs to flash two or three times. Hold the unit steady between
flashes to improve decode performance.
•Turn the hand-held computer on. Wait until the unit has booted up completely.
•Aim at the barcode and press the scan key or the trigger. Hold the trigger until a successful or failed
scan result is obtained.
•When the scan button or trigger is pressed, a red, oval shaped light (the framing marker) is displayed.
Centre the framing marker in the field—either in the centre of the barcode you want to scan or in the
centre of the area in which multiple barcodes are to be scanned.
The illumination LEDs will flash (typically several times) and a picture of the barcode is taken.
Psion Omnii Hand-Held Computer User Manual
3.8Windows Embedded CE 6.0
3.8.1Navigating in Windows Embedded CE and Applications
Graphic user interfaces such as Windows Embedded CE for portable devices and desktop Windows (Windows Vista™, Windows 7, Windows 8, etc.) utilize ‘point and click’ navigation. An equivalent keyboard shortcut is also available for every ‘point and click’ action.
Windows Embedded CE supports the same ‘point and click’ user interface and keyboard shortcuts as
desktop Windows with one difference—the ‘point and click’ action is accomplished using a touchscreen
rather than a mouse. Actions can be performed using any combination of keyboard shortcuts or touchscreen tapping. In those applications that support it, you can also flick and pan your finger to scroll
through screens.
3.8.1.1Navigating Using a Touchscreen
Note: If the touchscreen is not registering your screen taps accurately, the touchscreen may need
recalibration. Refer to “Calibrating the Touchscreen” on page 27.
The Omnii comes equipped with a stylus—a pointing tool that looks like a pen. The stylus is used to select
objects on the touchscreen. You can also use gestures with your fingers. You can use two gestures: pan and
flick. Use left or right flicks to quickly move between tabs of a multi-tab control panel, or to scroll long lists
of options. Use panning by touching and dragging a page that has scrollbars.
Chapter 3: Getting To Know Your Omnii
Windows Embedded CE 6.0
Note: To prevent damage to the touchscreen, use only a finger touch or the stylus (pen) supplied
with your Omnii.
To choose an icon, open a file, launch an applet or open a folder:
•Double-tap on the appropriate icon.
3.8.1.2Navigating Using the Keyboard
If you would like to use keyed input to choose icons and to navigate dialog boxes, refer to Table 3.6 for a description of the navigation keys.
Table 3.6 Keyboard Navigation
OperationKey or Key Combination
Switch between active applications[ALT] [TAB]
Open task manager[ALT] [ESC]
Move the cursorArrow keys
Open file, folder or icon[Enter]
Exit & Save[Enter]
Close/Exit & Do Not Save[ESC]
Navigate Dialog Boxes[TAB]
Select Radio Button/Press Button[SPACE]
Go to Start Menu[Windows]
To move cursor up [SHIFT] [TAB]
To display the contents of the next ‘tab’ in a dialog box [CTRL] [TAB]
Keep in mind that unlike a desktop computer, the Omnii does not support key chording (pressing two keys
at the same time). You must press one key followed by the next in sequence.
Psion Omnii Hand-Held Computer User Manual
35
Chapter 3: Getting To Know Your Omnii
The Windows Classic Shell Startup Desktop
3.8.2The Windows Classic Shell Startup Desktop
When the Omnii boots up, the default startup desktop (Windows Classic Shell) is displayed. Any applications
stored in the Startup folder start up immediately.
Note: The startup folder is located in \Windows\StartUp and \Flash Disk\StartUp.
Figure 3.5 Omnii Windows Classic Shell Startup Desktop
To access desktop icons:
•Double-tap on the icon to open a window or, in the case of an application icon, launch an application.
On the keyboard:
•Use the arrow keys to highlight the icon, and press [Enter] to launch the highlighted icon.
Note: If the arrow keys do not highlight the desktop icons, the desktop may not be selected. Press
[Windows] to display the Start Menu, and select Desktop. Now the desktop will be “in focus”
and the arrow keys will highlight the icons.
36
Psion Omnii Hand-Held Computer User Manual
3.8.2.1The Taskbar
The Omnii is equipped with a taskbar at the bottom of the screen. It displays icons through which you can
view the battery capacity and radio signal quality of your unit. If the hand-held is attached to a charger,
cradle, docking station, or Snap Module, an associated icon is displayed. In addition, the taskbar displays
the application(s) currently running on your unit.
The taskbar also displays active modifier keys: [SHIFT], [ALT], [CTRL], [FN] and [SYM]. Keys that have been
locked “on” are displayed with underlined letters. For example, if you have set the [CTRL] key lock to “on” in
the Keyboard menu and you press the key, it is displayed as an underlined ‘Ctrl’ in the taskbar. (For detailed
information on modifier keys and keyboard options, see “The Keyboard” on page 22).
Chapter 3: Getting To Know Your Omnii
The Windows Classic Shell Startup Desktop
3.8.2.1.1 Using the Taskbar
A tooltip is displayed as each taskbar icon is highlighted. The tooltip provides the status of each icon.
If you’re using the touchscreen:
•Tap and hold on an icon to display the icon's tooltip. Double-tap the icon to open the Control Panel
dialog box associated with the icon. For example, double-tap the battery icon to display a dialog box
listing the current battery capacity information.
On the keyboard:
•Press [Windows] to display the Start Menu.
•Choose Shortcuts from the Start Menu, and then press the [RIGHT] arrow key to display the sub-
menu.
•Choose System Tray in the sub-menu.
•Use the arrow keys to highlight the icon in the taskbar about which you’d like more information.
•Press [Enter] to display the appropriate dialog box.
3.8.2.1.2 Customizing the Taskbar
To customize the taskbar so that it displays only those icons you require:
•In the Start Menu, choose Settings, and then Ta sk b ar .
If you’re using the keyboard:
•Press [Windows] to display the Start Menu.
•Highlight the Settings option, highlight Ta skba r in the sub-menu, and press [Enter].
The Ta s k bar and S tart Menu dialog box is displayed.
Psion Omnii Hand-Held Computer User Manual
37
Chapter 3: Getting To Know Your Omnii
The Windows Classic Shell Startup Desktop
•Tap on the items you want to activate or deactivate. The check mark indicates active items.
If you’re using the keyboard:
•Highlight the options you want to activate, and press the [SPACE] key to select them. A check mark
indicates active items.
3.8.2.2The Start Menu
The StartMenu lists the operations you can access and work with. It is available from the startup desktop or
from within any application.
•To display the menu, tap on the Start Menu.
Note: Tap on the item in the menu with which you want to work.
If you’re using the keyboard:
•Use the arrow keys to highlight a menu item, and press [Enter], or
If the menu item has an underlined character:
•Type the underlined alpha character. For example, to display the Run dialog box, type the letter ‘r’.
3.8.2.2.1 Programs
•Choose Programs to display a sub-menu of options. The programs displayed will be those resident in
the Windows\Programs folder of the computer.
38
Psion Omnii Hand-Held Computer User Manual
Chapter 3: Getting To Know Your Omnii
The Windows Classic Shell Startup Desktop
Figure 3.6 Program Sub-Menu
This sub-menu allows you to choose Command Prompt, Internet Explorer, installed applications (e.g., Micro-
soft WordPad), PsionVU Access, Remote Desktop Connection, Wi-Fi Config, or Windows Explorer.
Demo
This folder contains the Scanner Demo, Demo Signature and Demo Sound applications. Scanner Demo can
be used to test how the hand-held reads barcodes. Demo Signature allows you to capture a signature
written on the screen with your stylus and save it to a file. Demo Sound allows you to record and playback
sound files. The ‘Sample Rate’ and the ‘Bits Per Sample’ are the rates at which the sound will be recorded.
Sounds recorded at the higher sample rate or bits per sample will be higher quality sound but will require
more file storage space. Lower sample rates and/or bits per sample produces a smaller file, but the sound
quality suffers. The record and play buttons operate the same as any recording device. The X icon deletes
the sound and the diskette icon allows you to save your sound.
Command Prompt
Command Prompt is used to access the DOS command prompt. At the prompt, you can type DOS commands such as dir to display all the directories in the drive.
Internet Explorer
The Omnii is equipped with Microsoft Internet Explorer for Windows Embedded CE. You can access the Internet Options icon through the Start Menu under Settings>Control Panel or by double-tapping on the
desktop icon My Device and then, double-tapping on the Control Panel icon.
Microsoft WordPad
WordPad is a basic word processor used to create, edit, and print .rtf, .doc, and .txt files.
PsionVU Access
PsionVU Access allows you to change the appearance and actions of the desktop from the default Windows
Classic Shell to the PsionVU shell.
Remote Desktop Connection
Remote Desktop Connection is an Omnii application used to connect to a Windows Terminal Server so that
you can run a “session” on the Server machine using the hand-held (Windows Embedded CE device).
“Remote Desktop Connection” on page 97 provides a website with details about this option.
Wi-Fi Config
The Wi-Fi Config application is used to configure the Omnii 802.11a/b/g/n radio for one or more wireless
network profiles.
Psion Omnii Hand-Held Computer User Manual
39
Chapter 3: Getting To Know Your Omnii
The Windows Classic Shell Startup Desktop
Windows Explorer
The Windows Explorer installed on your Omnii is consistent with all Windows Embedded CE devices.
3.8.2.2.2 Shortcuts
Figure 3.7 Shortcuts Sub-Menu
System Tray
If your touchscreen is not enabled, you can use the System Tray option to access the icons in the taskbar at
the bottom of the screen. The taskbar displays indicators such as a radio signal icon. These indicators are
attached to dialog boxes that provide additional information.
•Choose Shortcuts>System Tray.
When System Tray is chosen, the taskbar icons become accessible. To display the dialog box attached to
an icon:
•Use the arrow keys to highlight an icon, for example, the Bluetooth icon.
•Press [Enter] to display the Bluetooth menus.
Cycle Tasks
When Cycle Tasks is selected (and the Task Manager is not open), you can cycle through active applications.
To cycle through your active applications:
•Choose Shortcuts>Cycle Tasks, or
•Press [ALT] [TAB].
Tas k M a n a ger
The Task M a n a g e r allows you to switch to another task or to end an active task. To display the task
manager window:
•Tap on Shortcuts>Task Manager, or
•Press [ALT] [ESC].
40
Psion Omnii Hand-Held Computer User Manual
3.8.2.2.3 Settings
The Settings sub-menu includes the following settings: Control Panel, Network and Dial-up Connections
and Taskbar and Start Menu.
Figure 3.8 Settings Sub-Menu
Chapter 3: Getting To Know Your Omnii
The Windows Classic Shell Startup Desktop
Control Panel
The Control Panel contains applets used to configure hardware, the operating system and the shell. If your
Omnii is running with the Psion Open TekTerm application or another application, additional configuration
applets may appear in the Control Panel.
Network and Dial-Up Connections
The Network and Dial-up Connections window allows you to configure the Omnii network interfaces or
execute an existing configuration. Refer to “Connectivity” on page 17 for radio setup details.
Taskbar and Start Menu
The Ta s k bar and S tart Menu option displays a dialog box in which you can customize the taskbar, choosing
which options will be displayed. Refer to “Customizing the Taskbar” on page 37 for additional details about
this option.
3.8.2.2.4 Run
Choosing the Run option from the Start Menu displays a dialog box in which you can enter the name of the
program, folder or document you want to open or launch.
Psion Omnii Hand-Held Computer User Manual
41
Chapter 3: Getting To Know Your Omnii
The PsionVU Desktop Shell
3.8.2.2.5 Shutdown
The Shutdown menu includes these options: Suspend, Warm Reset and Cold Reset.
Suspend
The Suspend option suspends the Omnii immediately. This is equivalent to turning the hand-held off.
Warm Reset
The Warm Reset option resets the hand-held, leaving all saved files and registry settings intact. Any
unsaved data is lost.
Cold Reset
The Cold Reset option resets the hand-held. Any files not stored in permanent memory are lost; however,
the registry settings are saved.
3.9The PsionVU Desktop Shell
The appearance and actions of the desktop can be changed by tapping on the PsionVU Shell icon on your
desktop, which activates the PsionVU shell.
Note: The Omnii will be reset if you choose to switch shells.
42
Psion Omnii Hand-Held Computer User Manual
Chapter 3: Getting To Know Your Omnii
Hold the stylus or your finger on the Active Tasks, Favourites, or Notifications Bar,
Fav our ite s Ba r
Notifications Bar
Active Tasks Bar
and swipe to the left or right to switch to the next screen.
The PsionVU Desktop Shell
Figure 3.9 Switch to PsionVU Shell
After resetting the Omnii, the desktop appearance will be very different. The programs are accessed with
finger (or stylus) taps and swipes. If there are more applications than shown on one screen, a white animated dot will be present on the side of the screen in the direction of the next set of icons. Swiping the
screen to that direction will move the display to the next screen.
Note: Although the Desktop appearance defaults to the “Ingenuity” theme, the theme is not
changed using the PsionVU Shell icon. To change themes, open the Shell Settings>Advanced
menu in PsionVU Access (see “Shell Settings” on page 94).
A different program, PsionVU Access, enables you to customize your computer settings, remove or add
shortcuts to the Favourites Bar and Control Panel, and limit access to various different components on the
computer and the system tray icons for security. For details see “PsionVU Access” on page 92. To change
your Desktop background, refer to “Shell Settings” on page 94.
Active Tasks Bar
Open applications are shown in the top bar—the most recently opened is the first icon on the left. Tapping
once on a program icon will maximize the application. This feature replaces the Task Manager of the
Windows Classic Shell.
Psion Omnii Hand-Held Computer User Manual
43
Chapter 3: Getting To Know Your Omnii
Restoring the Windows Classic Shell
Date/Time Bar
Tapping once on the date or time will open the Date/Time Properties settings to enable you to change your
settings and time zone.
Fav o u rites B a r
The Favourites Bar replaces the Windows Classic Shell’s Desktop and Start Menu. These icons are the
program shortcuts from your Windows>Start Menu. Tapping once will open the program. If you tap and hold
on an icon, the application name is displayed.
Notifications Bar
This bar shows the run-time program notifications for Battery, Volume, Wi-Fi, Phone or GPRS, and other notifications for the programs you are running. This feature replaces the Taskbar of the Windows Classic
Shell.
Desktop Minimized View
When an application is opened and maximized, the desktop view is minimized and the Notifications Bar is
shown at the bottom of the screen. Tapping anywhere on the Notifications Bar (except on the SIP) will
restore the PsionVU desktop.
Note: In order to use the SIP, turn on the automatic settings in Control Panel>Input Panel.
PsionVU Access
The PsionVU Access program allows you to open a different program, PsionVU, which enables you to customize your computer settings, remove or add shortcuts to the Favourites Bar and Control Panel, and limit
access to various different components on the computer and the system tray icons for security. For details
see “PsionVU Access” on page 92. To change your Desktop background, refer to “Shell Settings” on
page 94.
To open PsionVU:
•Tap on the PsionVU Access icon in the Favourites Bar.
3.9.1Restoring the Windows Classic Shell
The default Desktop appearance and actions can be restored by tapping on the PsionVU Shell icon in the
Favourites Bar.
44
Psion Omnii Hand-Held Computer User Manual
Figure 3.10 Shell Switch to Windows Classic Shell Desktop
Note: The Omnii will be reset if you choose to switch shells.
3.10General Maintenance
Chapter 3: Getting To Know Your Omnii
General Maintenance
3.10.1Caring for the Touchscreen
The touchscreen is covered with a thin, flexible polyester plastic sheet with a conductive coating on the
inside. The polyester can be permanently damaged by harsh chemicals and is susceptible to abrasions and
scratches. Using sharp objects on the touchscreen can scratch or cut the plastic, or crack the internal conductive coating. The chemicals listed below must not come into contact with the touchscreen:
•mustard
•ketchup
•sodium hydroxide
•concentrated caustic solutions
•benzyl alcohol
•concentrated acids
If the touchscreen is used in harsh environments, consider applying a disposable screen protector
(RV6105). These covers reduce the clarity of the display slightly but will dramatically extend the useful life
of the touchscreen. When they become scratched and abraded, they are easily removed and replaced.
Do not to expose the touchscreen to direct sunlight for prolonged periods of time. If this is unavoidable, use
a UV screen protector to extend the the life of the screen.
3.10.2Cleaning the Omnii
Important: Do not immerse the unit in water. Dampen a soft cloth with mild detergent to wipe
the unit clean.
To prevent damage to the touchscreen, use only your finger or the stylus (pen)
supplied with your Omnii.
•Use only mild detergent or soapy water to clean the hand-held unit.
•Avoid abrasive cleaners, solvents or strong chemicals for cleaning. The Omnii has a plastic case that is
susceptible to harsh chemicals. The plastic is partially soluble in oils, mineral spirits and gasoline. The
plastic slowly decomposes in strong alkaline solutions.
•Exposure to aircraft de-icing fluids can degrade the plastics on Omnii. If the Omnii is used near aircraft
de-icing environments, regular rinsing with water is recommended.
•To clean ink marks from the keypad and touchscreen, use isopropyl alcohol.
Psion Omnii Hand-Held Computer User Manual
45
4
CONFIGURATION
CONFIGURATION4
4.1 Overview of Software..................................................... 51
The Omnii programs and applications are accessed through two main areas from the Desktop Start Menu:
Programs and Settings>Control Panel. This chapter details the configuration for the major software from
both areas, listed alphabetically.
4.1.1Psion Software Advantage
Psion Software Advantage is a collection of applications and features designed to support system administrators and end users. These tools enable enterprises to customize the product to meet their needs and to
maximize productivity.
AGPSWiFiConnect A.R.C.
App Launch KeysPsionVu
Battery HealthTweakIt
Bluetooth ManagerScanner
CompassTotal Recall
Dr. DebugManage Triggers
PartnerUpWiFi Config
4.1.2Microsoft Software
Windows CE 6.0 R3 is a 32-bit, real-time, multitasking Operating System. The OS features a small footprint,
with compatibility to port existing Win32 applications and Touch & Gesture support.
Some of the major Windows CE 6.0 R3 components are:
Control Panel, where both Psion Advantage and Microsoft applications are listed
Flash Lite
Internet Explorer Embedded
Microsoft WordPad
Remote Desktop Connection
Windows Explorer
Chapter 4: Configuration
Overview of Software
4.2The Control Panel
The Windows Embedded CE Control Panel provides a group of applications through which you can set a
variety of system-wide properties, such as power, keyboard sensitivity, network configuration, system
backup, desktop appearance, and so on.
When the Omnii boots up, the startup desktop (Windows Classic Shell) is displayed, and any applications
stored in the Startup folder start up immediately.
To access the Control Panel:
•Press the [Windows icon] to display the Start Menu.
•Tap on Settings>Control Panel.
If you’re using the keyboard:
•Press the [Windows icon] to display the Start Menu.
•Highlight Settings in Start Menu, and press the [RIGHT] arrow key to highlight the Control Panel.
•Press the [Enter] key.
The Control Panel folder contains icons used in the setup of your Omnii.
Psion Omnii Hand-Held Computer User Manual
51
Chapter 4: Configuration
Control Panel Applications
Figure 4.1 Control Panel Icons
4.2.1Control Panel Applications
The Control Panel provides a group of applications that allow you to customize and adjust settings on your
Omnii. This section shows the related icons in the Control Panel and gives a brief description of each.
App Launch Keys
By mapping keys to applications using this program, you can then launch those applications from a single
key-press.
Bluetooth
Opens the Bluetooth Manager which provides options for configuring various Bluetooth peripherals. It also
provides the capability to use a Bluetooth-enabled cellular phone as a data modem to exchange information with other Bluetooth devices and provide network access.
Certificates
This program provides access to the Certificates Manager and Stores. The Certificates Manager displays
the certificates in the Windows Certificates Store, and allows you to import, delete, and view these certificates. “Compass” on page 66 directs you to the appropriate setup information.
Compass
The internal compass can be calibrated to indicate in which direction the unit is pointed.
Date/Time
Allows you to set the current Month, Date, Time, and Time Zone on your unit.
Dialing
Specifies dialing settings, including area code, country code, dial type and the code to disable call waiting.
You can store multiple patterns—for example, ‘Work’, ‘Home’, and so on using this dialog box.
Display
Changes the display backlight and the appearance (colour scheme) on the unit desktop.
Dr. Debug
Provides both error diagnostic and troubleshooting tools.
Error Reporting
Allows you to enable or disable Microsoft error reporting prompts.
52
Psion Omnii Hand-Held Computer User Manual
Chapter 4: Configuration
Control Panel Applications
GPS Settings
Allows you to enable and configure GPS operation.
Imagers
The Imagers applet is used to create, modify, delete, and activate imager settings. This icon is only present
when the appropriate imager is installed. For detailed information, see Appendix B: “Imager & Camera Settings”.
Input Panel
Provides the framework for a Microsoft Soft Input Panel (SIP) should you need to design your own SIP, or
change some soft keyboard options.
Internet Options
Provides options to configure your Internet browser. You can determine items such as the default and
search page that the browser applies when connecting to the Internet, the cache size, the Internet connection options, and the security level that is applied when browsing.
Keyboard
Toggles character repeat on and off and specifies delay and rate for repeated characters. It also allows you
to adjust the keyboard backlight threshold and intensity, and many other functions.
Manage Triggers
This utility allows you to define buttons as triggers for different devices. For example you would use this
utility to configure a button for the scanner, RFID reader, and camera.
Microphone
Enables you to adjust the gain for the specific microphones associated with your hand-held.
Network and Dial-up Connections
Displays network interfaces and allows new dial-up and VPN interfaces to be created. It also allows Windows
configuration of the interface. Refer to “Connectivity” on page 17 for details.
Owner
Provides fields in which you can specify owner information. A Notes tab allows additional information to be
entered and displayed when the unit is powered up. Network ID tab information is used to access network
resources. (This information should be provided by your System Administrator.)
PartnerUp
This app displays a number of pre-loaded applications. By tapping on an application in the list, you are
taken to the associated web site and allowed to install the application.
Password
Allows you to assign a password to restrict access to elements of the unit. Once assigned, password access
cannot be circumvented so it is important that you write down your password and keep it in a safe place.
PC Connection
Enables direct connection to a desktop computer (or through ActiveSync—see “Data Transfer” on page 17).
Selecting the Change Connection button allows you to change the type of direct connection to your PC.
Power
Displays battery pack power status. (Alternately, battery status can be accessed through the taskbar.) Additional tabs allow you to determine suspend states and specify a suspend threshold.
PsionVU
PsionVU enables you to customize your computer settings, remove or add shortcuts to the desktop and
Control Panel, and lock down access to various different components on the computer and the system tray
icons for security. With PsionVU and PsionVU Shell (see “The PsionVU Desktop Shell” on page 42) you can
customize the entire look and feel of your User Experience.
Psion Omnii Hand-Held Computer User Manual
53
Chapter 4: Configuration
Control Panel Applications
Quick Defrost
The optional Heater Control feature for the OmniiXT15f freezer models is used in cold environments to
prevent condensation from developing on or inside the Omnii. Refer to Appendix F: “Omnii XT15f Freezer
Variants” for detailed information.
Region and Language
Allows you to specify the local language that is to be displayed on the hand-held screen along with the
format of numbers, currency, time and date for your region.
Remove Programs
Lists the programs that can be removed from your unit. To remove a program, select it and then click on
the Remove button.
Scanners
Provides scanner parameters and the barcode symbologies that the Omnii barcode scanner will successfully read.
Screen Rotation
This feature enables you to change screen orientation into either landscape, portrait, or both modes.
Storage Manager
Allows you to view information about the storage devices that are present, such as SD-MMC flash cards. For
details, see page 105.
Stylus
Adjusts how Windows Embedded CE recognizes your double-tap (as slow or rapid successive taps). In the
Calibration tab, you can recalibrate your touchscreen by tapping on the Recalibrate button and following
the directions on the screen.
System
You can display the system and memory properties, as well as create your device name. In the Memory tab,
you can allocate memory between storage memory and program memory.
System Properties
Identifies the computer’s software and hardware components, indicating which components are installed,
their version or part numbers, and whether they are enabled or disabled.
Total Rec a l l
Provides access to a backup/restore and deployment utility to maintain applications and settings over cold
reboots and for multiple devices.
TweakI t
Allows you to change Advanced System Settings (interface, network, and servers), User System Settings
(display font size), and provides the Registry Editor.
Volume & Sounds
Allows you to adjust the volume of the sound emitted to indicate events like warnings, key clicks, and screen
taps. You can also configure system (Windows) sounds and .wav files.
Wireless WAN
Provides access to technology like GSM/GPRS, which allows wide area networking capability such as internet browsing via GSM/GPRS. It also provides access to the Phone API. For detailed information, see
Appendix G: “Wireless Wide Area Network (WWAN) Settings”.
54
Psion Omnii Hand-Held Computer User Manual
4.3App Launch Keys
The App Launch Keys icon allows you to map a key to an application so that you can then launch the application from a single key-press.
•In the Control Panel, choose the App Launch Keys icon.
To assign an application key:
•Tap the Add button.
Chapter 4: Configuration
App Launch Keys
•Press the key you want to use to launch an application. (If an unsupported key is pressed, a message
appears on this screen letting you know.)
The cursor moves to the App field and a new screen is displayed where you can choose the application to
which you want to assign the application key. If you need to, you can Browse through the information in
your Omnii until you locate the application you want to launch.
•Once you’ve selected the file you want to map, tap on OK.
The cursor moves to the Data field. You can use this field if you need to need to define command line parameters for your application. If you don’t want to assign any parameters, you can leave the Data field
blank. If, for example, you want to assign an application launch key to launch the WordPad application, you
can leave this field blank. If you want to assign an application launch key that will open a specific document
in the WordPad application, you need to browse to and choose that document while the cursor is in the Data
field.
•Tap on OK.
Psion Omnii Hand-Held Computer User Manual
55
Chapter 4: Configuration
Bluetooth
®
Setup
•If you need to Edit, Remove or Add another App Launch Key, you can do it from this final screen. Oth-
erwise, tap on OK to save your Application Launch Key.
•To launch the application you chose, press the application key you assigned.
4.4Bluetooth® Setup
Bluetooth is a global standard for wireless connectivity for digital devices and is intended for Personal Area
Networks (PAN). The technology is based on a short-range radio link that operates in the ISM band at
2.4 GHz. When two Bluetooth-equipped devices come within a 10 metre (32 ft.) range of each other, they
can establish a connection. Because Bluetooth utilizes a radio-based link, it does not require a line-of-sight
connection in order to communicate.
It is possible to communicate with a variety of Bluetooth peripherals, including GSM/GPRS handsets, scanners, printers, and so on.
Psion provides built-in support for:
•GSM/GPRS universal handset
•Bluetooth printer
•Bluetooth headset
Keep in mind that Bluetooth and IEEE 802.11g radios both operate in the 2.4GHz band. Although the Omnii
includes features to minimize interference, performance of the system will not be optimal if you use both
radios simultaneously. Typically, when both radios operate in the hand-held at the same time, they cannot
transmit simultaneously—this has a negative impact on overall system throughput. To minimize the impact
on the backbone 802.11 network, Psion recommends using Bluetooth peripherals that have low transaction
rates (such as printers and scanners).
Bluetooth peripherals are configured by choosing the Bluetooth icon in the Control Panel. In addition,
review the manual shipped with your Bluetooth device to determine the method used to associate with the
Omnii host.
Note: The Bluetooth radio uses an internal antenna.
•In the Control Panel, choose the Bluetooth icon to display the Bluetooth Manager screen.
The BluetoothManager allows users to search, pair and connect to other Bluetooth devices within their
personal area network.
The Bluetooth radio is disabled by default. Before you begin the setup process:
•Tap on the Mode tab, and tap in the check box next to Tur n o n Bluetooth. Tap on OK.
When the radio is enabled, a Bluetooth icon appears on the taskbar at the bottom of the screen. It is ready
for setup.
56
Psion Omnii Hand-Held Computer User Manual
4.4.1Paired
This tab lists all paired devices and their corresponding services. The format of the name is <Device
Name>:<Service Name>. Additional information may appear in this screen such as the Port Numbers for
Serial Profiles service.
To learn how to scan for devices to pair, review “Device” on page 58.
Note: If a service is actively paired and connected, the device and its services are displayed in bold
Chapter 4: Configuration
Paire d
typeface in this list.
•Tap on an item in the Paired tab to display an associated pop-up menu.
The displayed menu depends on the type of the service chosen.
Query Services and Remove Commands
•Query Services displays a Services dialog box where a pairing service is chosen.
•Remove unpairs the highlighted service and deletes the entry from the tab.
OBEX OPP (Object Exchange-Object Push Profile) Commands
The OPP defines two roles—a Push Server and a Push Client. Push Server is the device that provides an
object exchange server. Push Client is the device that pushes and pulls objects to and from the Push Server.
OBEX OPP contains the following unique menu option:
•Send File displays an Open File dialog box where the file to be sent can be selected. When the transmis-
sion begins, another dialog box tracks the progress of the file transmission.
HSP/HFP (Headset Profile/Hands-Free Profile) Service Commands
The HSP (Headset Profile) allows users to connect their device to Bluetooth enabled headsets and other
audio devices.
HSP/HFP services provide the following unique menu options:
•Connect Audio establishes an audio connection to the Bluetooth headset.
Psion Omnii Hand-Held Computer User Manual
57
Chapter 4: Configuration
Device
•Disconnect Audio disconnects the audio connection from the Bluetooth headset.
•Volume Control displays a dialog box where the headset and microphone volume can be adjusted.
4.4.2Device
In this tab, users can discover and display Bluetooth devices.
4.4.2.1Discovering and Removing Devices
Scan discovers Bluetooth devices in range of the Omnii and lists them in this tab. Any existing devices previously discovered and listed will also be displayed.
Clear removes all Bluetooth devices listed except those with currently paired and connected services.
Note: To limit the number of devices listed to a particular type of device, refer to “Filtering By Class
of Device (COD)”, next section.
4.4.2.2Filtering By Class of Device (COD)
This menu allows you to filter the displayed devices by their COD. If, for example, you choose Computer
from this menu, only the devices that have the matching Computer COD value will be displayed. Choosing All lists all detected devices.
58
Psion Omnii Hand-Held Computer User Manual
4.4.2.3Device Pop-up Menu
The Device pop-up menu allows you to pair a device, update a device name or delete a device from the list.
Pair begins the pairing process by querying the services and profiles of the discovered device. An authenti-
cation dialog box is displayed the first time a Bluetooth device is paired.
Refresh Name repeats the device name inquiry, updating the name. This command is useful if a device is
listed without a name (unknown), or if a device name has been changed remotely.
Delete removes this device from the list.
Chapter 4: Configuration
Device
4.4.2.4Pairing a Device
To pa i r d evices :
•Follow the manufacturer’s instructions to place the remote device in pairing mode.
•Choose the Devices tab and Scan for devices in your area.
•When the scan is complete, tap on the device to which you want to pair.
•In the pop-up Device menu, tap on Pair.
An Authentication dialog box is displayed.
•If the remote device has authentication enabled, type the PIN in this dialog box.
•To proceed without authentication, tap on Next.
After entering the device PIN, the Services dialog appears with a list of services available for that device.
Psion Omnii Hand-Held Computer User Manual
59
Chapter 4: Configuration
Device
•Click in the check box to the left of the service to activate it.
•Click on Done.
Services that require more information present a configuration dialog box. Serial Profile is an example.
This dialog box offers a number of additional options such as enabling Encryption and selecting four different Modes: Serial, ActiveSync,Scanner, and Printer Port.
Serial is used for simple serial port communication.
ActiveSync is for ActiveSync-over-Bluetooth.
Scanner is used to create a connection to a barcode scanner. A serial connection is created, then the
Scanner Services is notified of the connection so that the incoming barcode scan will be forwarded to
Scanner Services directly.
Printer Port must be chosen here if you want to communicate with a paired Bluetooth printer. For further
details, see “Mode” on page 61.
•Once you’ve completed the information, tap on Next and then in the Services screen, click on Done.
60
Psion Omnii Hand-Held Computer User Manual
4.4.3Servers
When a remote Bluetooth device initiates a Bluetooth connection to the Omnii, the remote device is considered the ‘Bluetooth master’ and the hand-held, the ‘Bluetooth slave’. In order for the remote device to
connect to the hand-held, the Omnii must offer a service in the form of a server. The Servers tab allows
these services to be enabled and configured. There are three server services available: Serial, Scanner and
OBEX OPP.
Serial server enables the Serial Port Profile server; a Serial Port can be selected from the drop-down menu.
You can assign either a BSP or a COM prefix from the drop-down menu. BSP (Bluetooth Serial Port) was
created by Microsoft to allow Bluetooth to have its own serial prefix in order to free up virtual COM prefixes
as these are limited and are widely used.
Chapter 4: Configuration
Servers
Note: Even after a Serial Port Profile server is created, an application must open the created port
Scanner server enables a Serial Port Profile server and then relays it to the Scanner Service (SCS). This is
used for Bluetooth barcode scanners that operate in client mode. SCS opens the server port and handles
the scanner input.
OBEX OPP server enables the Object Push Profile server. A warm reset must be performed on the Omnii
after a change is made to this option. The OPP Server allows other Bluetooth devices to send files to this
device.
•Tap on the check box to activate the server.
4.4.4Mode
before a remote device can connect.
Turn on Bluetooth activates the Bluetooth radio.
Discoverable determines whether the Omnii is visible or invisible to other devices.
Psion Omnii Hand-Held Computer User Manual
61
Chapter 4: Configuration
About
Printer Port allows you to assign and enable a virtual outgoing COM port selected from the drop-down
menu to communicate with a paired Bluetooth printer. Keep in mind that when a port is chosen, the printer
must be on and connected to the chosen port for a remote device to be able to connect.
•Select a port within the Printer Port drop-down list, e.g. BSP1:
•Check the Printer Port check box.
•Open the Device tab and tap on Scan.
•Tap-and-hold each Bluetooth Printer device entry and then select Pair, key-in the Passcode (if needed)
and then tap Done. DO NOT select any services!
•Close the Bluetooth Manager.
•Select the Bluetooth device to print to—you will need to key-in (or programmatically raise) the following
key sequence [CTRL] [ALT] [F1].
•You can now select the Bluetooth device to which you wish to print.
Allow Bluetooth to wake system allows remote Bluetooth devices to wake the Omnii by requesting a Blue-
tooth service that requires host intervention. This feature can also be used when the Omnii is waking from suspend to significantly to reduce the initialization time of the Bluetooth system.
4.4.5About
Device Name displays the broadcasted name of the hand-held. The name can be changed in the System
Properties applet: Start>Settings>Control Panel>System icon>Device Name tab.
Local Address displays the MAC address (BD_Addr) of the Bluetooth chip.
HCI Version & LMP Version display the version of the chip firmware.
Component indicates the version of the Psion Bluetooth Subsystem (the manager, drivers, etc).
Profiles lists the supported profiles on this specific Omnii.
4.4.6The Bluetooth GPRS WAN Connection
The following steps describe how to set up an Internet data connection using a GSM cellular telephone with
Bluetooth. The Omnii communicates via Bluetooth to the cell phone, which then accesses a WAN (Wide Area
Network) and transfers data using GPRS.
1.Enable the Dial-Up Networking service in the cell phone.
2.Make the phone discoverable.
3.Pair the phone service with the Omnii Dial-Up Networking service using the Bluetooth Manager.
(For instructions on pairing devices, refer to “Pairing a Device” on page 59.)
4. To set up the Internet parameters, choose the Network And Dial-up Connections icon from the Control Panel.
62
Psion Omnii Hand-Held Computer User Manual
The Bluetooth GPRS WAN Connection
Chapter 4: Configuration
5.Tap on Make New Connection.
6.In the Make New Connection dialog box, choose Dial-Up Connection. Enter a name for your GPRS
network connection.
7.C ho ose t he Next button to display the Modem dialog box.
8. In the drop-down menu labelled Select a modem, choose the name of the modem with which you
want to connect, and then choose the Configure button to display the Device Properties dialog
box.
The Omnii communicates via Bluetooth to your Bluetooth equipped cellular telephone and retrieves
the parameters for the Device Properties dialog box. Omnii then disconnects.
Psion Omnii Hand-Held Computer User Manual
63
Chapter 4: Configuration
The Bluetooth GPRS WAN Connection
9.Under the Call Options tab, turn off Cancel the call if not connected within, and press [Enter] to
save your changes.
10. In the Modem dialog box, choose the Next button to display the Phone Number dialog box.
The phone number you enter is network carrier dependent. Once you’ve specified all the necessary
information, choose the Finish button.
11. In the Control Panel, choose the Dialing icon.
12. The values in the Dialing Properties dialog box need to be edited according to your network carrier
specifications.
64
Psion Omnii Hand-Held Computer User Manual
Chapter 4: Configuration
Once you’ve edited this dialog box to reflect your network carrier requirements, press [Enter] to save
your changes.
13. At this point, return to the Control Panel, and choose the Network and Dial-up Connections icon.
14. In the network connection window, the new network configuration—in this case, New Connection is
displayed. Tap on the new icon.
Certificates
When you tap on your new connection, an onscreen message indicates the status of your connection: con-nected, disconnected, error messages, and so on.
4.5Certificates
This program provides access to the Certificate Manager and Stores. The Certificate Manager displays the
certificates in the Windows Certificate Store, and allows you to import, delete, and view these certificates.
Omnii checks that the certificate has been digitally signed by a certification authority that the Omnii explicitly trusts. This option is used in conjunction with 802.1x authentication to enhance Omnii security.
•In the Control Panel, choose the Certificates icon.
Your Omnii has certificates preinstalled in the computer. My Certificates is the repository for the device’s
personal certificate store, Other Authorities is the repository for the intermediate certificate store, and
Trusted Authorities is the repository for the Trusted Root certificate store.
Psion Omnii Hand-Held Computer User Manual
65
Chapter 4: Configuration
Compass
You can import or remove certificates, and view certificate information for any listing, including names,
dates, serial numbers, etc.
For a detailed description about Certificate setup for both the server and client-side devices (Omnii HandHeld Computers), refer to the following website:
Like all compasses, the Omnii digital compass indicates the direction in which the unit is pointed. If you find
that the compass is inaccurate, you may need to calibrate it.
•In the Control Panel, choose the Compass icon.
•Tap on the Calibrate button and follow the directions to calibrate the compass. Make certain that
you perform the figure ‘8’ indicated in the instructions in a fairly wide loop to better ensure
successful calibration.
When the compass recalibration is complete, a message appears on the Omnii screen indicating
successful calibration.
Note: The accuracy of the digital compass is affected by the following:
a) close proximity to large magnets or metal structures, and
b) internal scanner/imager activation.
66
Psion Omnii Hand-Held Computer User Manual
4.7Data Transfer between Omnii and a PC
Data transfer options vary slightly depending on the type of operating system installed in your PC.
For Windows XP SP2 operating systems or earlier, Microsoft
used to connect your Omnii to PCs.
®
If the Windows Vista
quired to transfer data between your Omnii and your PC.
By using a Snap Module or Desktop Docking Station with your Omnii, you can connect to a PC with a
cable to :
•View Omnii files from Windows Explorer.
•Drag and drop files between the Omnii and the PC in the same way that you would between PC drives.
•Back up Omnii files to the PC, restore them from the PC to the hand-held again, etc.
4.7.1Uploading Data in a Docking Station
The Desktop Docking Stations allow your hand-held to upload transaction data to a server computer when
a radio link is not available. When the Omnii is properly inserted in a docking station, a dock icon is displayed in the taskbar at the bottom of the unit screen. For detailed information, refer to “Desktop Docking
Stations - Models ST4002 and ST4003” on page 142.
4.7.2Using Microsoft ActiveSync
, Windows 7 or later, operating system is installed in your PC, ActiveSync is not re-
Data Transfer between Omnii and a PC
®
ActiveSync® connectivity software can be
Chapter 4: Configuration
Note: If you use a serial port to connect devices like the Omnii to your desktop computer, the connection
may not succeed because ActiveSync has trouble connecting at non-default baud rates.
To work around this problem, set the ActiveSync baud rate on the desktop to use the same baud
rate as the device. You can set the baud rate by editing the registry on the desktop host computer,
as detailed in the steps outlined at the following website:
http://support.microsoft.com/kb/324466
To install ActiveSync, follow the step-by-step instructions provided with the program’s setup wizard. For details, go to the following website and type the name into the search box:
If you are running Windows Vista, Windows 7, or later, your data transfers do not require ActiveSync.
Instead,you will need to download Windows Mobile Device Center. For instructions, go to the following
website and type the name into the search box:
To transfer data between your PC and your hand-held:
•Tap on Start>Computer to display the drives. The Omnii will be visible here.
•Open drives, files and folders as you would on your PC.
Psion Omnii Hand-Held Computer User Manual
67
Chapter 4: Configuration
Display Properties
4.8Display Properties
•In theControl Panel, choose the Display icon.
4.8.1 Background
•In the Display Properties dialog box, open the Background tab. This dialog box allows you to customize
your background image.
4.8.2 Appearance
•In the Display Properties dialog box, open the Appearance tab. This dialog box allows you to customize
the display colour scheme.
4.8.3 Backlight
The backlight is activated for a configurable amount of time. The Display Properties dialog box in the
Control Panel allows you to specify the intensity of the backlight along with how long the backlight remains
on when the unit is not in use (no key press, scanner trigger, etc.).
Note: Keep in mind that this option may be restricted to supervisory use only.
•In theDisplay Properties dialog box, open the Backlight tab.
68
Psion Omnii Hand-Held Computer User Manual
Chapter 4: Configuration
Backlight
Note: Backlight changes take effect immediately. You do not need to reset the unit.
To maximize battery run time, keep the display backlight brightness and active durations as
low as possible.
Intensity
This parameter is used to adjust the light intensity of the Omnii backlight. Sliding the bar to the left lowers
the light intensity, and sliding it to the right raises the intensity.
Bright For
The value chosen from this drop-down menu determines the duration of time that the backlight stays on at
the configured intensity after the last user action (keypress, scan trigger).
Dim For
The value chosen from this drop-down menu determines the duration of time that the backlight stays on at
half the configured intensity (dimmed backlight) after expiration of the Bright For delay and as long as no
user action takes place (such as a keypress or scan trigger). At the expiration of the Dim For duration, the
display backlight shuts off.
External Power Check Box
When you select the check box next to When using external power keep the backlight always ON, the backlight remains ON at the configured intensity when the Omnii is operating with external power (not battery
power). If the Omnii is drawing power from its battery, this option is ignored and the other parameters
defined in Display Properties dialog box take effect.
Psion Omnii Hand-Held Computer User Manual
69
Chapter 4: Configuration
Dr. Debug
4.9Dr. Debug
Dr. Debug is an error diagnostic and troubleshooting tool.
•Tap on Start>Settings>Control Panel. Tap on the Dr. Debug icon.
4.9.1Status
This tab indicates the status (on/off) of the debug engines. Tapping on Browse logs displays error logs for
your review. The logs should be used as reference when working with Psion Technical Support personnel.
4.9.2Utilities
The Utilities tab can be used to log network traffic. When you tap on the Start button, debug data is col-
lected so that, if necessary, it can be forwarded to a Psion technician for evaluation.
Psion Omnii Hand-Held Computer User Manual
70
The Utilities tab can also be used to log heater control logic board information.
4.9.3Motion Meter
Chapter 4: Configuration
Motion Meter
Tapping on the Start button enables the Motion Meter feature. Once enabled, this applet records the
number of impacts the Omnii has sustained, the distance of the fall in meters, the duration in 10
second, and the date and time that the event occurred. The top 40 events are logged in a non-volatile location and can be used for diagnostic purposes by Psion or the site administrator.
4.9.4Settings
•Choose an Error Level from the drop-down menu.
•To change the location where debug information will be stored, tap on the button to the right of the
Log Folder option.
ths
of a
Psion Omnii Hand-Held Computer User Manual
71
Chapter 4: Configuration
Error Reporting
4.10Error Reporting
Error Reporting allows you to enable or disable Microsoft error reporting prompts.
•Tap on Start>Settings>Control Panel>Error Reporting icon to access your options.
4.11GPS (Global Positioning System) Settings
This applet allows you to define how the GPS module operates. You can determine when the GPS module is
powered and operating, and choose from a set of GPS profiles built into the modem. You can also set up the
AGPS Manager (an assisted GPS utility).
•Tap on Start>Settings>Control Panel>GPS Settings icon.
4.11.1Power
This tab allows you to dictate how the GPS module behaves. The GPS Power drop-down menu is used to
control when the GPS is powered on and off.
•Off – the GPS module is left off, always.
• Always on – the GPS module is powered on at all times regardless of the power state of the hand-held
(suspend).
•On, and off in suspend – the GPS module is powered on, but if the Omnii is in suspend mode, the GPS
module is turned off.
Psion Omnii Hand-Held Computer User Manual
72
4.11.2Profiles
Tapping on the GPS Profile Selection drop-down menu allows you to choose an appropriate profile: Default,
Automotive or Pedestrian.
•Default profile is a good general profile suitable for most uses.
•Automotive profile is designed for in-vehicle use, providing quick location updates as the vehicle
moves. When the GPS module is set to this profile and the vehicle enters an area such as a tunnel
where satellite coverage is interrupted, it will attempt to predict the vehicle position.
•Pedestrian profile is designed for those using the GPS module while walking. It takes into account the
slower pace of the pedestrian when mapping the location of the user. When the GPS module is set to
this profile and the operator moves into an area where satellite coverage is interrupted, the GPS
module will not attempt to predict the operator’s movement.
Chapter 4: Configuration
Profiles
4.11.3Programs
Tap on the GPS Program Port drop-down menu to choose the communication (COM)
port that the GPS software will use to communicate with the GPS receiver.
Psion Omnii Hand-Held Computer User Manual
73
Chapter 4: Configuration
AGPS
4.11.4AGPS
To determine your location, a GPS module receives data from three or more GPS satellites in fixed orbit
around the Earth. The GPS module triangulates your location based on the time it takes for signals to get to
and from the satellites. This works well in fairly clear areas, outdoors for example. However, if you’re attempting to triangulate your location in city centres where signals bounce off tall concrete buildings or
from within a building, the GPS module will have greater difficulty calculating a fix.
AGPS reduces Time To First Fix (TTFF) and increases the likelihood of finding and keeping a fix in poor coverage areas such as indoor sites. AGPS downloads satellite ephemeris (orbital) data to the Omnii periodically through Wi-Fi or WWAN. The downloaded data is used by the GPS module to speed the process of
getting a fix.
Update
•Click on the Update button to download Extended Ephemeris (EE) files from a secure host on the Internet using any interface that has an Internet connection. These files contain several days worth of
ephemeris (orbital) data that can be used if the satellite’s broadcast ephemeris is not available.
The Status field above the Update button displays the progress of the download, and once successfully
downloaded, the Status field will read Idle.
Settings
•Click on the Settings button to define the AGPS server connection settings.
The AGPS server connection settings drop-down menu allows you to choose from two settings: Use default settings and Use custom settings.
The Use default settings option is generally acceptable for most applications. Note that aside from the Update field in which you can choose how long the fix is stored in your Omnii, the field values cannot be
edited.
The Use custom settings option is generally used to configure devices that will have access only to an in-tranet rather than the Internet and should only be altered with the assistance of qualified Psion personnel.
They will be able to help you configure your Psion devices and web server to retrieve the ephemeris data.
Psion Omnii Hand-Held Computer User Manual
74
4.11.5Info
This tab provides general information about the GPS module such as the firmware version, the date on
which files were last updated, and so on. If GPS module support service is required, you may be asked to tap
on the Save button in this tab and forward the information to Psion support staff.
4.12Imager & Camera Settings
Chapter 4: Configuration
Info
The Imagers applet is used to create, modify, delete, and activate imager and camera settings. The principle
uses of the applet are to decode barcodes and to capture images. A Demonstration Application is provided
to demonstrate how the imager works. Refer to “Demo” on page 39 for details.
Refer to Appendix B: “Imager & Camera Settings” for configuration details.
To launch this applet:
•In the Control Panel, choose the Imagers icon.
Note: This icon is only displayed when the appropriate imager is installed in your Omnii. If there is
an imager installed but this icon is not present, additional software (ICS) may need to be
installed.
To enable a newly-installed imager, Press and hold down the [FN] key and the
[Enter/Power] key simultaneously for a minimum of three seconds.
Psion Omnii Hand-Held Computer User Manual
75
Chapter 4: Configuration
Soft Keyboard
Input Panel
Button Icon
Input Panel
4.13Input Panel
The Omnii is equipped with a Soft Input Panel (SIP). Shown below is the standard Microsoft SIP, accessed
from the Control Panel.
Tapping on the Input Panel button displays a soft input panel (soft keyboard) that can be customized using
the Input Panel dialog box.
Important: If the Input Panel button icon is not visible in the taskbar, from the ‘Start’ menu,
tap on Settings>Taskbar and Start Menu. Tap the check box next to ‘Show Input
Panel Button’. To remove this icon from the taskbar, tap in the check box to erase
the check mark.
The soft keyboard operates just like a standard keyboard except that rather than pressing a key, you tap on
letters, numbers, modifier keys, etc. on the Omnii screen.
To customize the appearance and behaviour of the soft keyboard:
Tap on the Input Panel icon in the Control Panel.
Figure 4.2 Input Panel Properties
•Tap on the Options button to change the appearance of your soft keyboard.
Psion Omnii Hand-Held Computer User Manual
76
Note: You can also display this dialog box by double-tapping on the Input icon in the far-right cor-
ner of the taskbar.
Fig ure 4. 3 Soft Keybo ard Op tio ns
4.14 Keyboard Properties
This icon displays the Keyboard Properties dialog box in which you can adjust the repeat rate of the keys,
the intensity of the keyboard backlight and the behaviour of the [FN] and [SYM] modifier keys. This dialog
box also allows you to define macro keys and Unicode characters.
•In the Control Panel, choose the Keyboard icon.
Chapter 4: Configuration
Keyb oard Properties
4.14.1Key Repeat
Note: These settings apply when a key is held down continuously.
•In theKeyboard Properties dialog box, open the Repeat tab.
Repeat Delay
The value assigned for this parameter determines the delay in milliseconds between repeat characters.
Sliding the Repeat Delay bar to the left increases the delay between key repeats, and sliding the bar to the
right shortens the repeat delay time.
Psion Omnii Hand-Held Computer User Manual
77
Chapter 4: Configuration
Keyboard Backlight
Repeat Rate
The value assigned for the Repeat Rate parameter determines how quickly the key you press repeats and is
measured in characters per second (cps). Sliding the bar to the left slows the repeat rate, and sliding the bar
to the right increases the repeat rate.
Note: Use the field at the bottom of this dialog box to test the repeat delay and rate settings
you’ve chosen.
4.14.2Keyboard Backlight
•In theKeyboard Properties dialog box, open the Backlight tab.
Intensity
This parameter is used to adjust the light intensity of the Omnii keyboard backlight. Sliding the bar to the
left darkens the keyboard backlight intensity, and sliding it to the right lightens the intensity.
Note: The keypad backlight maximum brightness will decrease over time as it ages. Use mid-range
intensity settings when possible to extend the backlight lifespan. When the backlight starts
to dim, use this parameter to make it brighter.
ON For
The value chosen from this drop-down menu determines the duration of time that the keyboard backlight
stays on after the last user action (keypress or scan trigger).
Note: Tapping in the check box next to ‘When using external power, keep the backlight always
ON’ forces the keypad backlight to remain on when the unit is operating with external power.
4.14.3Keyboard One Shot Modes
•In theKeyboard Properties dialog box, open the One Shots tab.
78
Psion Omnii Hand-Held Computer User Manual
Chapter 4: Configuration
Keyboard Macro Keys
The options in this tab allow you to determine how modifier keys on your Omnii behave. For each modifier
key—[ALT], [SHIFT], [CTRL], [FN], and [SYM]—you have the following options in the drop-down menu: Lock ,
OneShot, and OneShot/Lock.
Note: Keep in mind that checking the taskbar lets you know whether or not these keys are locked
on. For example, if the [FN] key is locked ‘on’, the taskbar at the bottom of the screen displays it underlined. If this key is displayed without the underline in the taskbar, you’ll know
that the key is not locked. It will become inactive following a key press.
Important: Once you’ve assigned a One Shot mode to a modifier key, you need to tap on the
OK button at the top of the tab to activate your selection.
Lock
If you choose Lock from the drop-down menu, pressing a modifier key once locks it ‘on’ until you press the
modifier key a second time to unlock or turn it off.
OneShot
If you choose OneShot, the modifier key remains active only until the next key is pressed.
OneShot/Lock
OneShot/Lock allows you to combine these functions. When you choose this option and you press the modifier key once, it remains active only until the next key is pressed.
If you press the modifier key twice, it is locked ‘on’, remaining active until the modifier key is pressed a third
time to turn it ‘off’.
4.14.4Keyboard Macro Keys
•In the Keyboard Properties dialog box, open the Macros tab.
A macro has 200 programmable characters (or “positions”). The macro keys can be programmed to replace
frequently used keystrokes, along with the function of executable keys including [Enter], [BACKSPACE] and
[DEL] ([FN]-[BACKSPACE]), function keys and arrow keys.
Recording and Saving a Macro
You can program up to 6 physical macro keys, depending on your keyboard layout. You can also increase
the number of virtual macro keys up to 15 using Scancode Remapping (for details, see “Scancode Remap-
ping” on page 81).
•In the Macro menu highlight a macro key number, for example macro 1, to assign a macro to macro key
[M1]. Choose the Record button.
A message screen is displayed instructing you to Enter Key Strokes to Record.
Psion Omnii Hand-Held Computer User Manual
79
Chapter 4: Configuration
Unicode Mapping
•Type the macro sequence you want to assign to the Macro key. You can type text and numbers, and you
can program the function of special keys into a macro.
•When you’ve finished recording your macro sequence, press the key sequence: [CTRL] [ALT] [Enter], or
choose the Stop Recording button.
A new screen ‘Verify Macro’ displays the macro sequence you created. The Save button is highlighted.
•Press [Enter] to save your macro, or highlight CANCEL and press [Enter] to discard it.
Executing a Macro
To execute a macro:
•Press the macro key to which you’ve assigned the macro.
Deleting a Macro
To dele t e a macro :
•In the Macros tab, highlight the macro number you want to delete.
•Choose the Delete button.
4.14.5Unicode Mapping
•In the Keyboard Properties dialog box, open the Unicode Mapping tab.
The Unicode Mapping tab is used to map combinations of virtual key values and [CTRL] and [SHIFT] states
to Unicode™ values. This tab shows the configured Unicode character along with the Unicode value. For ex-
80
Psion Omnii Hand-Held Computer User Manual
Chapter 4: Configuration
Scancode Remapping
ample, the sample screen above shows “a (U+0061)” indicating that the character “a” is represented by the
Unicode value “0061”, and so on. Keep in mind that Unicode configurations are represented as hexadecimal
rather than decimal values.
All user-defined Unicode mappings are listed in the Unicode Mapping tab in order of virtual key value, and
then by order of the shift state. If a Unicode mapping is not listed, the Unicode mapping is mapped to the
default Unicode value.
Adding and Changing Unicode Values
Important: Changes to Unicode mappings are not saved until you exit the Keyboard Proper-
ties dialog box.
•Choose the Add/Change button.
•Highlight a value in the Unicode mapping list. In the sample screen above, a value will be assigned to
virtual key 0 (VK 0).
•Position the cursor in the Unicode Mapping field, and type a Unicode value for the highlighted key.
Note: To add a shifted state, [SHIFT] and/or [CTRL], press [TAB] to position the cursor in the check
box next to ‘SHIFT Pressed’ and/or ‘CTRL Pressed’. Press [SPACE] to select the shift state
you want to assign.
Removing Unicode Values
•In theUnicode Mapping tab, highlight the item you want to delete, and choose the Remove button.
4.14.6Scancode Remapping
A scancode is a number that is associated with a physical key on a keyboard. Every key has a unique scancode that is mapped to a virtual key, a function or a macro. Scancode Remapping allows you to change the
functionality of any key on the keyboard. A key can be remapped to send a virtual key (e.g. VK_F represents
the ‘F’ key; VK_RETURN represents the [Enter] key, etc.), perform a function (e.g. turn the scanner on,
change volume, etc.) or run a macro.
There are three different tables of scancode mappings: the Normal table, the FN table and the SY M table.
Note: When using the Mobile Devices SDK Developers' Guide (PN 8100016), note that the
[ORANGE] key is interchangeable with the [SYM] key. Similarly, in the context of the scancode mapping tables, ‘Orange’ is interchangeable with ‘SYM’.
The Normal table defines unmodified key presses; the FN table defines key presses that occur when the
[FN] modifier is on; the SYM table defines key presses that occur when the [SYM] modifier is on. The default
Psion Omnii Hand-Held Computer User Manual
81
Chapter 4: Configuration
Scancode Remapping
mappings of these scancodes can be overwritten for each of these three tables using the Scancode Remap-ping tab accessed from the Keyboard Properties dialog box.
The first column in the Scancode Remapping tab displays the scancodes in hexadecimal. If the scancode is
remapped to a virtual key, that virtual key is displayed in the next column labelled ‘V-Key’. A virtual key that
is ‘Shifted’ or ‘Unshifted’ is displayed in the third column labelled ‘Function’.
If the scancode is remapped to a function or a macro, the first and second columns remain blank while the
third column contains the function name or macro key number (e.g., Macro 2).
Adding a Remap
To add a new remapping:
•Choose the Add button at the bottom of the dialog box.
The Remap Scancode dialog box is displayed.
•Type the scan code in hexadecimal in the field labelled Scancode.
Note: The Label field displays the default function of the scancode you are remapping.
Virtual Key, Function and Macro
The radio buttons at the bottom of the dialog box allow you to define to what the scan code will be remapped: Virtual Key, Function or Macro.
When Virtual Key is selected, you can choose to force [SHIFT] to be on or off when the virtual key is sent. If
No Force is selected, the shift state is dependent on whether the shift state is on or off at the time the
virtual key is sent.
82
Psion Omnii Hand-Held Computer User Manual
When Fu nc ti on is selected, a list of valid functions appears in the dialog box.
When Macro is selected, the macro keys available on your unit are listed in the dialog box.
•Choose Virtual Key, Function or Macro.
•Choose a function from the Fun cti on list in the dialog box, and tap on OK.
Editing a Scancode Remap
To edit a scancode:
•In the Scancode Remapping tab, tap on the remap you want to edit.
•Tap on the Edit button, and make the appropriate changes.
•Tap on OK to save your changes.
Removing a Remap
To delete a remap:
•In the Scancode Remapping tab, highlight the scancode you want to delete, and tap on the Remove
button.
•Tap on OK.
4.14.7Lock Sequence
The Lock Sequence menu allows you to lock the Omnii keyboard to prevent keys from being pressed accidentally when, for example, the unit is inserted in a holster.
Chapter 4: Configuration
Lock Sequence
•To lock the keyboard, tap in the check box next to Enable key lock sequence.
•Tap in the check box next to Keyboard locked at startup.
•In the Key sequence drop-down menu, choose the key sequence you will need to type to unlock the
keyboard.
Note: It is useful to leave the ‘Show popup message’ enabled (default) so that anyone attempting to
use the keyboard will see the key sequence they will need to enter to unlock the keyboard displayed on the screen.
A locked keyboard icon is displayed in the softkey bar when the keyboard is locked.
Psion Omnii Hand-Held Computer User Manual
83
Chapter 4: Configuration
Locked Keyboard
Icon
Manage Triggers
•Type the key sequence to unlock the keyboard.
4.15Manage Triggers
Allows users to configure how barcode scanners and other devices such as RFID readers are triggered. You
can configure the trigger ID for each trigger button for both single- and double-click, and the double-click
time.
•In the Control Panel, choose the Manage Triggers icon.
•In the Manage Triggers screen you’ll see a list of trigger mappings.
4.15.1Trigger Mappings
A trigger mapping is an association between a particular key on the keyboard and a driver or application,
the module(s)—sometimes referred to as “trigger consumer(s)”—of the trigger source. Along with keyboard
keys, the external trigger (scan button) is software-based. When the specified key is pressed, the owner (for
example, a decoded scanner) is sent a message.
84
Psion Omnii Hand-Held Computer User Manual
Chapter 4: Configuration
Add and Edit Trigger Mapping
Important: It is not possible to have two or more identical mappings—for example [F1] cannot
be mapped to the Non-Decoded Scanner twice—even if the trigger type is
different.
A keyboard key that is used as a trigger source will no longer generate key data,
or perform its normal function. For example, if the space button is used as a
trigger source, it will not be able to send space characters to applications.
Double-Click
When a key is pressed and released, then pressed again within the configured time (between 0 to
1000 msec), a double-click occurs. See also “Trigger-Press Type” on page 86.
Show All Modules
By default, the trigger mapping list only shows active mappings. Mappings for drivers or applications that
are not currently active are not normally displayed. By checking this check box, all mappings, both active
and inactive, are displayed.
Add
Tapping this button brings up the Add Mapping dialog (see page 85), so that you can add new trigger mappings.
Edit
Tapping this button brings up the Edit Mapping dialog (see page 85), so that you can edit existing trigger
mappings.
Remove
Tapping this button removes an existing mapping.
OK
The OK button in the top right of the Manage Triggers screen saves all changes made. If the cancel button X
is tapped instead, or the [ESC] key is pressed, all changes made will be discarded.
4.15.2Add and Edit Trigger Mapping
These dialogs allow you to add and edit trigger mappings.
Trigger Key
This drop-down list allows you to specify the source of the trigger events, such as the Soft Scan, Left Scan,
etc., for the trigger module selected.
Psion Omnii Hand-Held Computer User Manual
85
Chapter 4: Configuration
Microphone
Note: It is possible to map the same source to different modules (trigger consumers)—for example,
to both the Imager and Non-Decoded Scanner. If so, both devices/operations will occur
simultaneously. This is not recommended in most cases, especially with devices such as
Imagers or RFID Readers.
It is also possible to map different sources to the same module (trigger consumer)—for
example, two different trigger keys can be mapped to the RFID File System.
Add Key
Only existing trigger sources are shown in the Source combo-box. To add a new source to this list, tap on
the Add Key button. A dialog will pop up and allow you to select the keyboard key to use as a trigger
source.
Trigger-Press Type
You can enable either an Up/Down or Double Click response to a trigger press. Normally, when a trigger
(keyboard key, etc.) is pressed and released, a “trigger down” event is sent to the “owner”—that is, the application receiving the trigger press information—followed by a “trigger up”. If Double Click is chosen in this
menu, when the trigger is pressed, released, and then pressed again, a “double-click” event will have occurred. If a mapping with the type Up/Down has also been configured for the same source, it will only
receive the first set of trigger events.
Module Trigger
This identifies the driver or application receiving the trigger presses.
Show All Modules
By default, inactive owners are not shown. By checking this check box, all owners, both active and inactive,
are displayed.
4.16Microphone
•In the Control Panel, choose the Microphone icon. Use this dialog box to adjust the gain for the specific
microphones associated with your hand-held.
86
Psion Omnii Hand-Held Computer User Manual
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.