PSI NXG-Vision PS36L-P7, Li-36, NXG-Vision, PS36L-P7 User Manual

PS 36 L- P 7
PS3 6L-P7
NO TE:
to Powe rTec Solu tio ns M ode ls PS36 L-K7 (N ext G en era tion FT Tx Micr o UPS ) and all p ackag e acc es sor ies as li sted be low.
The ref erenc e to "N XG -Vi sio n" w ith in this U ser Man ual r ef ers
NX G- Vis io n INTRO DU CT ION
NXG-Visi on is des igned a nd in te nde d for use a s Deskt op or Wall -moun t
P
lea
s
e v
e
r
i
f
y a
l
l s
t
a
ndar
d c
ont
e
nt
s are a
cc
oun
t
ed f
or u
pon r
ece
i
p
t o
f
NXG
-
Vi
s
ion
. ST
AN
D
A
RD
: (
1) Powe r Supp
ly
/
C
h
arg
er; (
1) Li I
o
n B
a
t
ter
y P
ac
k
;
(1)
A
C Pow
er C
o
r
d; (1
) 7-
P
i
n C
on
n
ecto
r
; (
1
) U
s
e
r's M
a
nua
l
;
O
p
t
ion
a
l:
(1
) U
niver
s
a
l Wa
l
l M
o
unt E
nc
l
o
s
u
r
e w/ Cove r.
N
OT E:
PS3 6L-P7
VISUA L IND IC ATORS
1
Bat tery
Col or Red-
Ser vice or repl ace bat ter y or bat ter y is n ot ins talle d in NXG- Vi sio n.
,
2
Mut e
Col or-Yel low
Fla shing Aud ible A lar m si len ced for 24h rs. Soi d-Au dib le Al arm S ile nce U nti l man ual ly ena ble.
-
3
DC
Col or Gre en-
NXG Vis ion is w ork ing off Sta ndb y Po wer.-
4
Sys tem
Sta tus
Col or- Gre en
NXG Vis ion is R eci evi ng A C po wer l oad to
ope rate un der nor mal con ditio ns.
-
CONTR OL SWITC HES
5 6
7
4
3
2
1
5
6
7
VISUAL A ND AUDIBL E STATUS/ ALARM SI GN ALS
STATE
VIS UAL
IND ICATOR
AUD IBLE
IND ICATOR
DES CRIPT ION
Nor mal
Sys tem
Sta tus
Ind icati on On
Ope ratin g u nder n ormal AC lin e powe r load a nd con ditio ns, cha rges b atter y. Batt ery is con necte d and in g ood con ditio n.
ON Ba ttery
DC
Ind icato r On
AC l ine pow er fai lur e or A C cord
dis conne ction . NXG­Vis ion i s be ing sup pli ed wit h batt ery pow er.
Rep lace Bat tery
Bat tery
Ind icato r On
1 2 s eco nd a udi ble ind icato r every 15 min .
/
Rep lace f aul ty o r en d of lif e batt ery.
Bat tery
Mis sing
Bat tery
Ind icato r On
NXG Vis ion is o per ati ng on A C line p ower o nly wit hout av ailab le sta nby po wer for o utage sce nario . When b atter y is r emove d from uni t, batt ery ind icato r will ill umina te aft er 5 sec .
-
Low Ba tte ry
DC I ndi cat or Fla shes
1 2 s eco nd a udi ble ind icato r 4 time s per min ute .
/
Bat tery h as r eac hed equ al to or les s tha n 30% rem ainin g capac ity on bat tery di schar ge.
Rev iew the f ollow ing imp ortan t safet y warni ngs to av oid bod ily inj ury or da mage to eq uipme nt duri ng inst allat ion or op erati on of thi s devic e. Rea d ALL i nst ruc tio ns be for e att emp tin g to in sta ll or o per ate t his d evi ce.
Thi s devic e is inte nded fo r indoo r use onl y. To pre ven t the r isk o f fir e or ele trica l shock , insta ll in dry l ocati on free f rom dam p or wet en viron ment, or po tenti ally da mp or wet e nviro nment .
Adh ere to al l accep table o perat ing env ironm ent lim itati ons as li sted to pre vent th e risk of f ire or el ectri cal sho ck (see u ser spe cific ation s wit hin Use r's Man ual)
Ris k of fire o r explo sion if i mprop er batt ery pac k is inst alled a nd att empte d to oper ate wit h this de vice. D evice i s rated a nd appr oved fo r use w ith Pow erTec Sol ution s Inter natio n Li Ion Ba ttery P ack ONLY. Fol low Use r Manua l instr uctio ns for pr oper in stall ation a nd remo val of bat tery pa ck.
NO us er-re place able pa rts wit hin thi s devic e. Do not r emove c over fo r any r eason .
All ows NX G Vi sio n to c old st art po wer off Bat tery Pa ck when A C line po wer is no t pre sent an d new or re place ment pa ck is con necte d,pr ess a nd ho ld fo r 3 sec ond s.
-
All ows fo r DC lin e po wer res et o f op tic al Net work te rmina l.Pre ss and ho ld for 3 sec onds to r eset/ re boo t opt ica l new wor k ter minal .
Alar m Sil ence
Col d Sta rt
N.I .R. Res et
Dis ables Au dible Al arm fun ction . Press a nd rele ase to di sable Au dible Al arm for 2 4 hours . Press a nd hold for 1 5 secon ds to dis able Aud ible Ala rm inde finit ely. Pre ss and ho ld for an other 1 5 secon ds in ord er to re- enabl e Aud ible Ala rm func tion.
TEC HNI CAL S PEC IFI CATI ON
INP UT
Volt age Ra nge
100 Vac 240 Vac-
Fre quenc y R ange
50 6 0Hz/
Inp ut Pow er or d C
NEM A 5 15 3 Pro ng P owe r Cor d - / -
Int put Gr oun d Re fer enc e
Ear th Gro und ed
OUT PUT- ON AC
Out put Vol tag e
12V dc N omi nal ( )
Con tinuo us Pow er C apa cit y
3A 3 6WATT( )
OUT PUT- ON BAT TERY
Out put Vol tag e
12V dc N omi nal ( )
Con tinuo us Pow er C apa cit y
3A 3 6WATT( )
BATT ERY
Bat tery Typ e
Lit hium l on B att ery Pac k
Des ign Li fe
10 1 5Years-
Bat tery Ca pacit y
14 8 V 5 200 mAh. /
Typi cal Re cha rge Tim e
12 hr s
Rep lacea ble Pa ck
Yes
SUR GE PROT ECTIO N AND FILT ERI NG
Lig htnin g S urg e Pr ote cti on/
Yes I EC 6 100 0 4 5 2 005 LE VEL D( - - )
MAN AGEME NT
Bat tery A uto Cha rge -
Yes
Rem ote Ba tte ry A lar min g
Opt ional
Loc al Ala rmi ng A udi ble Vis ual ( / )
Yes
Ala rm Sile nce
24 Ho ur Sile nce
Yes
Dis able In defin itely
Yes
ONT Re set
Yes
Col d Start
Yes
PHY SICAL
Max imum D ime nsi ons × W×D (L )
155 mm×89 mm×31 mm
Wei ght lb( . )
1 76 lb wit h b atter y p ack.
ENV IRONM ENT
Ope ratin g Tem perat ure
-1 0℃ - 49℃( 14℉ - 12 0. 2℉) at fu ll po wer
Ope ratin g Humid ity
0- 95no nco nde nsi ng wi thi n enc los ure
Max Op era tin g Ele vaion
10 0 00ft 3 000 m ( , )
Sto rage Tem per atu re
-3 0℃ - 65℃( -2 2℉ -1 49℉)
FIGURE 2
FIGURE 3
FIGURE 1
FIGURE 1
FIGURE 2
PROCE DURE:
Remov e the N XG- Vis ion B atter y Pac k by sl iding o ff in o ppo sit e dir ectio n of inst all ati on( FI GUR E 3) an d fol low "In sta lla tion St ep A." a bov e for insta lli ng ne w NXG -Vi sion Ba tte ry Pa ck.
IN STALL ATIO N
A.Sli de NX G-V isi on Ba ttery P ack ( FIG URE 1) on to NX G-V isi on Po wer Sup ply / Charg er (F IGU RE 2) u nt il NX G-V isi on Ba ttery P ack b eco mes f ul ly fl ush w ith NXG-Vi si on Po wer S upp ly/Ch arg er. You sh ould he ar a "c lic k" when N XG- Vis ion Batte ry Pa ck is f ull y se ate d.
B.Con nec t pro vid ed AC P owe r Cor d to AC In pu t Con nec tor o n botto m of NXG- Vis io n Pow er Su ppl y/Cha rge r.
C.Con nec t 3 Pro ng AC Po we r Cor d Plu g End i nt o sta nda rd 3 Pr ong AC Rec ept acl e rated f or NE MA 5-1 5 3 Pro ng AC P lug .
D.Veri fy "S yst em St at us" L ED is " On" w ith Gre en il lum inati on.
E.Con nec t NXG -Vi sio n to ONT (Opti cal N etw ork Ter min al).
F.Ensur e "Sy ste m Sta tu s" LE D is th e onl y illum ina ted L ED on NXG -Vi sio n. If any ad dit ion al LE Ds a re il lum ina te d rec hec k NXG -Vi sion Ba tte ry Pa ck to m ak e sure it i s ful ly se ate d an d ens ure t hat a ll w iri ng fr om NX G-Visi on t o ONT is ins tal led corre ctl y as li ste d by O NT speci fic i nst ructi ons .