PSC Scanning QuickScan 6000, QuickScan 6000 plus User Manual

ANDHELD LASER SCANNER
U
I
NTERF ACE
NIVERSAL
P
ROGRAMMING
W
EDGE
PSC Scanning, Inc. 959 Terry Street Eugene, Oregon 97402-9120 Telephone: (541) 683-5700 Toll Free: (800) 547-2507 Fax: (541) 686-1702
PSC and the PSC logo are registered trademarks of PSC INC.
This manual and the procedures described in it are copyrighted, with all rights reserved. Under copyright law, this manual may not be copied in whole or part without prior written consent from PSC Scanning, Inc. The same proprietary and copyright notice must appear on any permitted copies as appears on the original. This exception does not permit copies to be made for others, whether or not sold. Under the law, copying includes translating into another language or format including electronic media.
Disclaimer
Reasonable measures have been taken to ensure that all information contained in this manual is complete and accurate. However, PSC Scanning, Inc. reserves the right to change any specification at any time without prior notice.
UNIVERSAL WEDGE INTERFACE PROGRAMMING
For your convenience, this guide provides minimal configuration and op­tion settings for your scanner's Universal Wedge interface. For more de­tailed programming information and features, reference the QuickScan 6000/6000 Plus Universal Wedge Programming Guide (R44-1548), avail­able from your dealer.
DISCONNECTING/CONNECTING THE INTERFACE (I/F) CABLE
To disconnect the I/F cable at the scanner, insert a bent paper clip or .050" hex driver into the opening marked CABLE RELEASE as shown in Figure 1, and push inward. Once the connector latch is released, con­tinue to hold in on the latch while carefully pulling the cable free. Connect the scanner to your system using ONLY the proper PSC ap­proved QuickScan 6000/6000 Plus I/F cable.
WARNING
Connection using an unapproved cable can result in damage to the scanner. QuickScan 6000/6000 Plus cables can be identified by a cable I.D. code printed on a white label, ap­proximately 1" in length, attached to them.
Paper Clip
Approved QuickScan 6000/6000+ Cable
Latch
Overmolding
DO NOT use unapproved cables
Interface
Connector
e s a
le
e
R
le b a
C
Figure 1. Disconnecting/Connecting the QuickScan 6000/6000 Plus I/F Cable
R44-1549
1
RETURN TO FACTORY CONFIGURATION
If, during a programming session, you wish to reset the scanner's con­figuration to its original factory settings, scan the RETURN TO FACTORY SETTINGS label below. Use this label ONLY IF NECESSARY, since it will reset any changes made to this interface during any previous program­ming session.
RETURN TO FACTORY SETTINGS
*/+$*
NOTE
When this feature is scanned, return to factory set­tings will take about five seconds to complete. The scanner will sound a tone at its conclusion.
P
ROGRAMMING MODE
The scanner must be placed in Programming Mode before its configura­tion can be altered using the barcodes in this guide. Enter Programming Mode by scanning the START label found at the bottom of each page. The scanner's green light will flash continuously, indicating the scanner is in Programming Mode.
While in Programming Mode, the scanner will recognize only specially formatted programming barcode labels like those contained in this guide, and will not decode barcode labels of any other type. Scan all program­ming barcode labels needed to set the scanner's features to the desired settings. The scanner will beep after each barcode label is scanned, indi­cating that the setting has been stored in memory. The scanner will emit a rejection tone if a scanned barcode programming label isn't valid. To exit Programming Mode and save all changes made during the pro­gramming session, scan the END label located at the bottom of each page. The scanner will return to normal operation.
Disconnecting power during Programming Mode will cause the scanner to return to its previous settings.
QuickScan 6000/6000 PLus
Universal Wedge Interface Programming
2
PC KEYBOARD WEDGE INTERFACE SELECTION
The default communication mode (factory settings) is Keyboard Wedge for PC AT (keyboard I.D. 11). Use the codes on this page to activate keyboard-wedge mode and to select the I.D. corresponding to your computer or terminal (reference Connectivity Guide R44-1040 or call PSC Customer Support):
*AEU*
KEYBOARD-WEDGE MODE ACTIVATED
Consult the list of connections listed in Connectivity Guide R44-1040 (or call PSC Customer Support) and enter the I.D corresponding to your computer or terminal using this barcode pad.
*AG1*
1
*AG4*
4
*AG7*
7
*AG2*
2
*AG5*
5
*AG8*
8
*AG3*
3
*AG6*
6
*AG9*
9
*AG0*
0
Use the next pages to adjust some general parameters of Universal Wedge communication.
*$%/*
START END
*$+$*
R44-1549
3
END OF M
One of the characters below can be systematically emulated by the scanner as the end of message character:
ESSAGE CHARACTER
*DP7* *DP3*
RETURN*
(DEFAULT)
FIELD EXIT
*DP5* *DP1*
ENTER TAB +
*DP6* *DP2*
CR/LF ; FEED ; SEND LF
*DP4* *DP0*
FIELD ADVANCE
NO CHARACTER
U
PPER/LOWER CASE OPTIONS
Use one of these codes to inform the scanner of the state of your keyboard:
*DH4* *DHI*
*$%/*
UPPER CASE/CAPS*
(DEFAULT)
START
QuickScan 6000/6000 Plus
4
Universal Wedge Interface Programming
LOWER CASE/SMALL
*$+$*
END
T
IME-OUT BETWEEN CHARACTERS
The insertion of a time-out between each character can sometimes avoid the occurrence of errors during fast transmission speeds (especially with PS/2, or when DOS and BIOS are very busy).
(I
NTERCHARACTER DELAY
)
*G00* *G14*
0 ms*
(DEFAULT)
20 ms
*G05* *G32*
5 ms 50 ms
*G0A* *G64*
10 ms 100 ms
T
RANSFORMATIONS
Use these codes to transform labels to the desired format before transmission to the host terminal.
*GHA* *GHO*
UPC TRANSMITTED AS EAN*
(DEFAULT)
UPC TRANSMITTED AS UPC
*GHS* *GHU*
UPC E TRANSMITTED AS UPC E*
R44-1549
(DEFAULT)
UPC E TRANSMITTED AS UPC A
*$+$**$%/*
ENDSTART
5
Asia Pacific
PSC Hong Kong Hong Kong Telephone: [852]-2-584-6210 Telefax: [852]-2-521-0291
Italy
PSC S.r.l. Vimercate (MI), Italy Telephone: 039/62903.1 Telefax: 039/6859496
Australia
PSC Asia Pacific Pty Ltd. North Ryde, Australia Telephone: [61]0(2)9878 8999 Telefax: [61]0(2)9878 8688
France
PSC Sarl LES ULIS Cedex, France Telephone: [33].1.64.86.71.00 Telefax : [33].1.64 46.72.44
Germany
PSC GmbH Darmstadt, Germany Telephone: + 49 (0) 61 51/93 58 - 0 Telefax: + 49 (0) 61 51/93 58 58
Japan
PSC Japan K.K. Shinagawa-ku, Tokyo, Japan Telephone: 81 (0)3 3491 6761 Telefax: 81 (0)3 3491 6656
Latin America
PSC S.A., INC. Miami, Florida, USA Telephone: (305) 539-0111 Telefax: (305) 539-0206
United Kingdom
PSC Bar Code Ltd. Watford, England Telephone: 44 (0) 1923 809500 Telefax: 44 (0) 1923 809 505
Corporate Headquarters
675 Basket Road Webster, NY 14580-9787 Telephone: (716) 265-1600 Toll Free: (800) 828-6489 Telefax: (716) 265-6400
Printed on recycled paper
© 1998 PSC
INC.
www.pscnet.com
R44-1549 (Rev. B)
PSC Scanning, Inc.
959 Terry Street Eugene, OR 97402-9150 Telephone: (541) 683-5700 Toll Free: (800) 547-2507 Telefax: (541) 686-1702
PRINTED WITH
SOY INK
Printed in USA 8/98
Loading...