3. General information ............................................................................................................................................
5. Construction ..........................................................................................................................................................
8. Connection of heat medium ...........................................................................................................................
9. Control elements ................................................................................................................................................
10. Wiring control elements ...................................................................................................................................
11. Reference information .....................................................................................................................................
3
4
5
6
7
8
9
11
12
13
14
2
1. INTRODUCTION
The company PROTON GROUP LLC thanks you for choosing
air heaters PROTON.
This manual is an integral part of the product and must
always accompany it, and should be transferred to the user.
To provide proper wiring and application of the unit, please,
study this manual thoroughly before installation.
We recommend keeping the manual safe in order to address
it during operation.
The user should strictly follow safety instructions while
installing, using and servicing the unit.
The access to the unit must be restricted for unauthorized
and unqualified personnel. The appropriate training of the
maintenance sta should be provided.
The manufacturer disclaims any responsibility for damages
caused by wrong installation and misuse of the unit.
The manufacturer disclaims any responsibility for damages
done by people who didn’t study the manual.
The manufacturer preserves the right to introduce any
amendments to the manual without prior notification.
The manufacturer preserves the right to alter the
construction which doesn’t impact its functioning and basic
technical parameters.
The air heater is intended only and exclusively to be installed
and used for purposes which it has been designed. Any
misuse or noncompliance with the manufacturer’s
instructions may lead to property damages, personnel injuries
or death. The user has to take measures to eliminate
possibilities of misuse of the unit.
3
2. SAFETY PRECAUTIONS
Before any actions connected with the air heater, please, study
this manual to provide safety.
Installation and connection of the equipment to pipelines and
networks must be performed by qualified personnel only,
having appropriate access.
During installation, start-up, repair and maintenance of the
air heater follow the safety rules.
Install the unit on a firm base or surface, which can stand its
weight filled with water.
Use screws appropriate for the material which the base is
made of.
Check correctness of connections of the system, accordance
of the heat medium parameters to the parameters indicated
on the rating plate as well as leak proof of joints before filling
in the heat medium.
Avoid substances and impurities in the heat medium causing
copper corrosion.
Check compliance of parameters of the electrical supply
network to the ones indicated on the unit’s rating plate
before connecting to the power supply.
Check grounding. Prohibit the use of the unit without
grounding as it may cause property damages, personnel
injuries and death.
Current network which feeds the unit’s motor and controls
must be additionally protected by a fuse to prevent
consequences of shunt fault.
Provide protection of a fan against overheat by connecting
protection devices to contacts of fan temperature sensor.
While the air heater is operating under low temperatures, the
-t
user must provide protection of the water heat exchanger or
use heat medium with special additives preventing copper
corrosion.
To prevent defrosting of the air heater’s heat exchanger
when circulation of the heat medium is stopped during a
heating period under outdoor temperatures lower than 0°C,
you need to drain the heat medium from the heat exchanger
and blow it o by compressed air.
4
3. GENERAL INFORMATION
Explosion proof
design
PROTON EX
It is designed to heat industrial premises and warehouses under conditions of extra explosion safety.
This equipment is to be mounted in buildings with increased probability of explosion as a result of
interaction with dangerous materials as well as because of some technological processes.
Principle of operation
The air heater PROTON is an element of a
heating system. It is designed for heating air and
Outlet pipe
Inlet pipe
its even distribution in buildings. Its work is
based on axial fan functioning, which charges
the air and pass it through a copper-aluminum
heat exchanger in which the heat medium
(hot water) flows at certain temperature.
Heated air is supplied into a room and is directed
to the working area by directing louvers.
Applications
Chemicals production premises
Paint and varnish industry
Furniture production premises
Oil- and gas processing factories
Workshops with installed vessels and
containers of high pressure
Premises of production of highly explosive
substances
Model range
PROTON EX 30 – heating power 10-30 kW
PROTON EX 50 – heating power 25-50 kW
PROTON EX 70 – heating power 40-70 kW