accuracy specifications of the
product are valid for one year after
the date of calibration, and the
product requires recalibration after
this period.
Only operate the measuring
instrument properly, for its
intended purpose and within the
parameters specified in the technical
data. Readings from moisture meters
are not definitive but are used to help
a professional make informed
judgment to the material’s moisture
condition. Conductive material such
as salts, carbon and metal can give
false positive readings.
2 Search Mode (REL)
The Aquant non-invasive mode gives
readings, in relative terms, of the
moisture condition up to 19mm / 3/4”
beneath the surface of materials. This
mode of operation is ideal for making
rapid surveys of solid walls and
floors and to pinpoint areas of
concern that may justify a more
extensive investigation.
Protimeter AquantPage 1
Page 4
2 Search Mode (REL) (cont.)
The Search mode may also be used as
an alternative to the Measure mode
when it is impractical or undesirable
to push electrode pins into surfaces.
Consider, for example, taking
moisture readings behind ceramic
tiles in shower cubicles or in walls
covered by quality wallpapers where
pinholes would not be acceptable.
Surface moisture (such as
condensation on an otherwise dry
wall) has little effect on Search mode
readings. Conductors (other than
water) within the material may cause
high Search mode readings. Make
sure the flat surface on the back of the
meter is in full contact with the
material to be tested.
It is recommended that users place
the meter onto different areas to
measure and do not slide the meter
across surfaces.
Note: Sliding the meter can cause
premature wear to the back of
the meter.
Page 2Protimeter Aquant
Page 5
3 Reference Mode
Measure the material until the meter’s
reading is stable, then press for
2 seconds. This will store the reading
until the mode changes of the meter
turns off. Now all reading taken after
will be displayed as normal, but
below you will see a second reading
that shows you if the material is
measured above or below the original
reading. Reference mode can be
useful when trying to establish what
materials are above or below a point
of reference or dry standard. See
page 6 for further information.
Protimeter AquantPage 3
Page 6
4Operating Aquant
Switch On:
Press the ON/OFF button.
The unit turns on, with the LCD
displaying all the segments and
sweeping the LED bar graph.
Page 4Protimeter Aquant
Page 7
Measurements:
The numeric measurement and color
LED will be shown as well as the
“DRY” (green) or “AT RISK”
(yellow) or “WET” (red), based on
the measurement shown.
70-169 DRY (Green)
170-199 AT RISK (Yellow)
200-999 WET (Red)
Reference Mode of Measurement:
Take the first measurement which
needs to be taken as reference. While
the first reading is displayed on the
screen, press and hold the button
for 2 seconds to enter the Reference
Mode. The display will be similar to
the one shown below.
To return to the normal measurement
mode, press again.
Protimeter AquantPage 5
Page 8
Settings:
Press and hold the button and
switch on the unit by pressing .
Hold both the buttons until the
Aquant displays the version.
Release both buttons while it shows
the version number. The unit enters
Settings Mode.
Page 6Protimeter Aquant
Page 9
DRY, AT RISK and WET Settings:
The first screen to appear in Settings
is the DRY, AT RISK and WET
setting screen.
This screen sets whether the
indication on the display needs to be
switched ON or OFF. When it is ON,
the moisture condition will be
displayed on the screen. When it is
OFF, no indication is displayed on
screen.
Protimeter AquantPage 7
Page 10
DRY, AT RISK and WET Settings
(cont.):
Use the button to turn ON/OFF
the settings.
If the unit detects no key press for 2
seconds in the Setting screen, it
moves to the next setting.
Pressing the button, after you
have entered the desired setting, will
save the setting and move the screen
to the next setting.
Page 8Protimeter Aquant
Page 11
Buzzer ON/OFF Settings:
Once the DRY, AT RISK and WET
settings are entered, the next setting
turns the Buzzer ON or OFF.
To change the settings, press the
button.
If the unit detects no key press for 2
seconds in the Setting screen, it
moves to the next setting.
Pressing the button, after you
have entered the desired setting, will
save the setting and move the screen
to the next setting.
Protimeter AquantPage 9
Page 12
Backlight Settings:
Once the Buzzer settings are entered,
the next setting turns the Backlight
ON or OFF.
To change the settings, press the
button.
If the unit detects no key press for 2
seconds in the Setting screen, it
moves to the next setting.
Pressing the button, after you
have entered the desired setting, will
save the setting and move the screen
to the next setting.
Page 10Protimeter Aquant
Page 13
Auto Off Time Settings:
When Auto Off is set, the unit will
shut down automatically at a
specified time between 1 and 6
minutes, if there is no key press
detected within the set time.
For example, if the Auto Off time is
set as 1, then the unit will
automatically shut down after a
minute when no key is pressed.
The duration will change based on the
set time of 1- 6 minutes.
If the auto off time is set to be "0",
then the unit will not automatically
turn off. A user must manually turn it
off by pressing and holding the
button for 5 sec.
Protimeter AquantPage 11
Page 14
Auto Off Time Settings (cont.):
Turn off time can be set by pressing
the button, and can be saved by
pressing .
After you save this setting, the unit
will exit to the measurement screen.
Battery Low Indication:
Whenever the battery is low, there
will appear a battery low indication
symbol on the screen (bottom right).
This indicates that the battery is low
and should be replaced soon. The unit
will continue to perform in battery
condition within the specified
accuracy, and turns off when the
battery reaches the limit.
Page 12Protimeter Aquant
Page 15
Holding/Freezing the Reading:
While measuring, if the reading needs
to be frozen for any observation,
press during measurement. A
text "HOLD" will be displayed on the
screen.
5 Battery Replacement
A 550mAh battery will last
continuously for more than 20 hours
for a Aquant in operation. A Battery
Low indication on the screen
indicates that the battery needs to be
changed in a short time.
Remove the screw assembled to fix
the battery lid on the back side of the
unit. Slide the battery lid downwards
applying a little pressure with the
thumb to open the battery
compartment.
Remove the battery, and replace. Care
must be taken to ensure that the
polarity is correct as below. Place the
battery inside the compartment.
Protimeter AquantPage 13
Page 16
6 Technical Specifications
Operating Conditions:
Operating temperature range:
0°C to 50°C
Humidity: 0 to 90% RH,
non-condensing
Measurement Specifications:
Non-Invasive moisture measurement:
Measurement depth:
up to 3/4” (19mm) deep
Reading: 70 to 999
(no effect on reading by
surface moisture)
7 Physical Specifications
Power:
9V- Alkaline 550mAh
Battery low indication on LCD
Size:
19cm x 6.5cm x 5cm
(7.5" x 2.5" x 2")
Gross Weight (without battery):
~240g
Buzzer
Audible buzzer for Key tone and
measurement indication,
user configurable
Regulatory Compliance
CE, RoHS, ETL
Page 14Protimeter Aquant
Page 17
Protimeter AquantPage 15
Page 18
Page 16Protimeter Aquant
Page 19
Page 20
Amphenol
Advanced Sensors
99 Washington Street
Melrose, MA 02176
Phone 781-665-1400
Toll Free 1-800-517-8431
Visit us at www.TestEquipmentDepot.com
INS5765 Rev. B, May 2014
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.