Protemp PT-24-DDF-F, PT-30P-DDF-AF, PT-20F-DDF-A, PT-20S-DDF, PT-24-DDF User's Manual And Operating Instructions

...
Page 1
User’s Manual and
Operating Instructions
Model Numbers: PT-18W-DDF-A, PT-20F-DDF-A,
PT-20S-DDF, PT-24O-DDF, PT-24-DDF, PT-24-DDF-F,
PT-30-DDF, PT-30P-DDF-A, PT-30P-DDF-AF
READ AND SAVE THESE INSTRUCTIONS
IMPORTANT: Read and understand all of the instructions in this manual before assembling,
starting, or servicing the fan. Improper use of this fan can cause serious injury. Keep this manual for future reference.
CAUTION
gasoline, solvents, paint thinners, dust particles, volatile or airborne combustibles, or any unknown chemicals.
This product meets and exceeds the requirements of OSHA 1910.212(a)(5), the standard which regulates electric fan blade safety, and is certified under UL# E355088.
Please note the serial number of your fan, and write it on the back of this User’s Manual for future reference.
For General Ventilating Use Only. Do Not Use To Exhaust Hazardous Or Explosive Materials And Vapors. Never use the fan in spaces which contain products such as
© 2013, Pinnacle Products International, Inc.
668 Stony Hill Road #302 Yardley, PA 19067 USA Toll Free: (800) 641-6996
Fax: (215) 891-8461 • Web: www.protemp.us • Email: info@pinnacleint.com
9500450290-13
Page 2
User’s Manual and
Operating Instructions
Table of Contents
Safety Information................................................................................................................................. 3
Notes Page............................................................................................................................................4
Troubleshooting Guide........................................................................................................................19
Warranty................................................................................................................................Back Cover
5
18” Wall Fan
PT-18W-DDF-A
6-7
20” Floor Fan
PT-20F-DDF-A
8-10
11
24” Barrel Fan
PT-24-DDF PT-24-DDF-F
12-13
24” Omni Fan
PT-24O-DDF
14-16
17-18
30” Pedestal Fan
PT-30P-DDF-A PT-30P-DDF-AF
20” Shop Fan
PT-20S-DDF
© 2013, Pinnacle Products International, Inc. 2 HVF Air Circulator User’s Manual
30” Floor Fan
PT-30-DDF
Page 3
NEVER LEAVE A FAN
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
UNATTENDED WHILE
OPERATING OR WHILE
CONNECTED TO A POWER
SOURCE
Safety Information
IMPORTANT: READ ALL INSTRUCTIONS CAREFULLY BEFORE ASSEMBLY, SERVICE OR
USE OF THIS FAN. FAILURE TO COMPLY WITH THESE INSTRUCTIONS COULD RESULT IN SERIOUS PERSONAL INJURY AND / OR PROPERTY DAMAGE.
THIS IS A FAN - NOT A TOY!
TO REDUCE THE RISK OF PERSONAL INJURY AND ELECTRIC SHOCK, FANS SHOULD NOT BE PLAYED WITH OR PLACED WHERE SMALL CHILDREN CAN REACH IT.
To guard against electric shock
while operating, do not allow fan to come in contact with other grounded objects such as pipes, radiators, etc.
Risk of fire, electric shock, or
personal injury when performing service or maintenance. Unplug or disconnect the fan from the power supply before servicing.
CAUTION Automatically
Operated Device - To Reduce The Risk Of Injury Disconnect From Power Source Before Servicing
To Reduce The Risk Of Fire
Or Electric Shock, Do Not Use This Fan With Any Solid- State Speed Control Device.
To Reduce The Risk Of Electric
Shock And Injury To Persons, Do Not Use In a Window.
To Reduce The Risk Of Electric
Shock, Do Not Expose To Water Or Rain. This unit is designed for indoor use only.
Installation work and electrical
wiring must be done by qualified person (s) in accordance with all applicable codes and regulations.
When servicing or replacing a
component requires the removal or disconnection of a safety device, the safety device is to be reinstalled or remounted as previously installed before operating this fan.
Use this fan only in the manner
intended by the manufacturer. If you have any questions, contact Customer Service at 800-641-6996.
- Before operating always check fan for loose or damaged parts. Inspect power cord for any damage. Never use fan if any parts are damaged or missing. Never use fan without safety guards attached.
- Operate only on 120 volt 60 Hz (cycle) current with a minimum of a 15 amp circuit.
- When used with an extension cord, use only cord of proper size (Amp rating), UL listed, and with receptacle to accept three prong grounded plug furnished on the fan’s power cord. Always keep power cord and extension cords away from heat, oil, and sharp edges. Inspect cords periodically and replace if damaged.
© 2013, Pinnacle Products International, Inc. 3 HVF Air Circulator User’s Manual
Page 4
NEVER LEAVE A FAN
UNATTENDED WHILE
OPERATING OR WHILE
CONNECTED TO A POWER
SOURCE
NOTES
__________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________
© 2013, Pinnacle Products International, Inc. 4 HVF Air Circulator User’s Manual
Page 5
Wall Mount Installation
WARNING
NEVER LEAVE A FAN
UNATTENDED WHILE
OPERATING OR WHILE
CONNECTED TO A POWER
SOURCE
18” WALL FAN: PT-18W-DDF-A
1. Attach fan to wall or ceiling using Upper Bracket (Item #6).
2. Be sure Upper Bracket (Item #6) is attached to a suitable beam when hanging.
Tools Needed:
- 10mm Adjustable Wrench.
Exploded View
1
2
3
4
5
6 7
The installer MUST be
certain that the support bracket is mounted to a minimum of a 2x4” stud, and that it is able to support 50 pounds continuously.
9
8
10 11
12
17
15
14
18
16
Figure 1: Exploded View of PT-18W-DDF-A
Replacement Parts
Item # Description Part Number
1 Logo Plate 95-043-0370 2 Front Guard 95-032-0150 3
Fan Blade Assembly 95-003-06064 5 6 Upper Bracket 95-061-0100 7 Rear Guard 95-032-0250 8 Motor 95-030-0515 9 Switch Holder 95-031-0300
© 2013, Pinnacle Products International, Inc. 5 HVF Air Circulator User’s Manual
Item # Description Part Number
10 Switch Gasket 95-031-0340 11 Switch (Chain) 95-031-0110 12 Switch Cover 95-031-0500 13 Cord Bushing 95-026-0160 14 Pivot Washer 95-024-0300 15 Swivel Spacer 95-050-0185 16 Pivot Screw 95-024-0310 17 Capacitor 95-004-0215 18 Power Cord 95-026-0230
13
Page 6
20” FLOOR FAN: PT-20F-DDF-A
WARNING
Installation and Assembly
NEVER LEAVE A FAN
UNATTENDED WHILE
OPERATING OR WHILE
CONNECTED TO A POWER
SOURCE
1. Remove 1 screw from each Frame Support L and R (Items #7* and #19*).
2. Slide Frame Support L and Frame Support R into Support Frame (Item #21*) and line up holes for screw.
3. Re-attach screw to Frame Support L and Frame Support R.
20” FLOOR FAN - OPTIONAL WALL MOUNT
Wall Mount Installation
1. Attach wall mount to stud (Item #24*)
2. Attach Lower Support Frame (Item #21*) to the Wall Mount (Item #24*) by replacing rear part of Lower Support Frame into hook of Wall Mount and resting front and rear feet of fan (Items #17* and #18*) onto the wall.
* On Page 7
4. Place the fan on level ground in a safe, desired position then connect to an approved power source.
Tools Needed:
- Phillips head screwdriver.
-10 mm adjustable wrench.
The installer MUST be certain that the support bracket is
mounted to a minimum of a 2x4” stud, and that it is able to support 50 pounds continuously.
NOTE: Fan must be mounted to wall so that both feet
are positioned against the wall surface. Mounting this fan to a bare stud without both fan feet posi­tioned against a flat surface will result in damage to the fan.
Figure 2: Wall Mount Installation
© 2013, Pinnacle Products International, Inc. 6 HVF Air Circulator User’s Manual
Figure 3: Wall Mount Installation - Close Up
Page 7
Exploded View
NEVER LEAVE A FAN
UNATTENDED WHILE
OPERATING OR WHILE
CONNECTED TO A POWER
SOURCE
20” FLOOR FAN CONTINUED
1
Figure 4: Exploded View of PT-20F-DDF-A
2
3
4
6
5
7
21
20
8
9
10
11
12
13
14
15
16
23
22
24
19
18
17
Replacement Parts
Item # Description Part Number
1 Logo Plate 95-043-0405 2 Front Guard 95-032-0160 3
Fan Blade Assembly 95-003-06164 5 6 Frame Washer 95-024-0250 7 Frame-Support L 95-024-0265 8 Main Circle Tube 95-024-0280 9 Top Washer 95-024-0290
10 Rear Guard 95-032-0260 11 Motor 95-030-0525 12 Switch Holder 95-031-0310
© 2013, Pinnacle Products International, Inc. 7 HVF Air Circulator User’s Manual
Item # Description Part Number
13 Switch 95-031-0120 14 Switch Cover 95-031-0510 15 Cord Bushing 95-026-0165 16 Control Knob 95-027-0110 17 Front Foot 95-023-0220 18 Rear Foot 95-023-0230 19 Frame-Support R 95-024-0275 20 Swivel Spacer 95-050-0180 21 Lower Support Frame 95-024-0245 22 Power Cord 95-026-0240 23 Capacitor 95-004-0225 24 Wall Mount Kit 95-078-0100
Page 8
Installation and Assembly
WARNING
WARNING
NEVER LEAVE A FAN
UNATTENDED WHILE
OPERATING OR WHILE
CONNECTED TO A POWER
SOURCE
20” SHOP FAN: PT-20S-DDF
1. Remove Knob Screw (Item #15*) and Wing Nut (Item #14*) from top of Post.
2. Slide Connector Bracket (Item #4*) onto top of post.
3. Line up holes on the Post and Connector Bracket (Item #4*).
4. Re-insert the Knob Screw (Item #15) through the Post and Connector Bracket (Item #14*) and tighten firmly with the Wing Nut (Item #14*).
Tripod Operation Instructions
TRIPOD LEG OPERATION
1. Fold legs out and slide support bracket to center of leg.
2. To adjust leg height; rotate locking ring clockwise to loosen.
NOTE: Keep a firm grip on the tripod while leg is
unlocked! The leg will collapse into itself unless
held tightly.
NOTE: Be certain to make all three legs the same
height. Setting legs to different heights will make the fan unbalanced and COULD FALL OVER.
3. Slide leg extension to desired height.
4. Rotate locking ring counter-clockwise and tighten firmly. Be sure the leg is secure before moving to next leg.
5. Repeat steps 2-4 for remaining legs.
5. Place the fan on level ground in a safe, desired position then connect to an approved power source.
6. Set desired tripod stand height following “Tripod Operation Instructions” below.
* On Page 10
TRIPOD CENTER POST OPERATION
1. To change the post height; rotate locking ring counter-clockwise to unlock post.
NOTE: Be certain to keep a firm grip on post while
unlocked! The fan will slide down to its lowest point if it is not held and slowly moved to desired
position.
2. Raise or lower post to desired position.
3. Rotate locking ring clockwise to lock post and tighten firmly.
DO NOT MOVE OR ADJUST
FAN WHILE IN OPERATION. THIS CAN CAUSE DAMAGE TO FAN AND INJURY TO THE OPERATOR.
Installation and Assembly
1. Attach Ceiling Mounting Kit (Item #16*) to 2x4” stud that is able to support 50 lbs continuously using M6x40mm screw. (See Figure 5**)
The installer MUST be certain that the support bracket is
stud, and that it is able to support 50 pounds continuously.
3. Be Certain that the Safety Pin lines up with the groove on the Connector Bracket (Item #4). (See Figure 6**)
© 2013, Pinnacle Products International, Inc. 8 HVF Air Circulator User’s Manual
mounted to a minimum of a 2x4”
OPTIONAL CEILING MOUNT
2. Slide Connector Bracket (Item #4*) onto Ceiling Mounting Post. (See Figure 7**)
4. Rotate the entire fan so the safety pin locks into place and the holes on the Mounting Post line up with the holes on the Connector Bracket (Item #4*). (See Figure 8**)
5. Insert the Knob Screw (Item #15*) through the Mounting Post and Connector Bracket (Item #4*) and tighten firmly with the Wing Nut (Item #14*). (See Figure 8**)
* On Page 10
** On Page 9
Page 9
NEVER LEAVE A FAN
UNATTENDED WHILE
OPERATING OR WHILE
CONNECTED TO A POWER
SOURCE
20” SHOP FAN CONTINUED - OPTIONAL CEILING MOUNT
Figure 5: Optional Ceiling Mount
Figure 6: Optional Ceiling Mount
Figure 7: Optional Ceiling Mount
© 2013, Pinnacle Products International, Inc. 9 HVF Air Circulator User’s Manual
Figure 8: Optional Ceiling Mount
Page 10
Exploded View
NEVER LEAVE A FAN
UNATTENDED WHILE
OPERATING OR WHILE
CONNECTED TO A POWER
SOURCE
20” SHOP FAN CONTINUED
123
4
567 8 91011
13
121514
16
Figure 9: Exploded View of PT-20S-DDF
Replacement Parts
Item # Description Part Number
1 Logo Plate 95-043-0420 2 Front Guard 95-032-0185 3 Fan Blade Assembly 95-003-0616 4 Frame 95-001-0500 5 Rear Guard 95-032-0285 6 Motor 95-030-0525 7 Switch Holder 95-031-0335 8 Power Cord 95-026-0270
© 2013, Pinnacle Products International, Inc. 10 HVF Air Circulator User’s Manual
Item # Description Part Number
9 Power Switch 95-025-0600 10 Capacitor 95-004-0250 11 Bushing 95-026-0180 12 Switch Cover 95-031-0540 13 Tripod 95-040-0100 14 Wing Nut 95-075-0400 15 Base Knob 95-015-0220 16 Ceiling Mount Kit 95-078-0300
Page 11
24” BARREL FAN: PT-24-DDF, PT-24-DDF-F
Installation and Assembly
1. Fully expand Pipe Frame (Item #20) open, and tighten Frame Brackets (Items #21 and #22) with attached bolt.
Exploded View
NEVER LEAVE A FAN
UNATTENDED WHILE
OPERATING OR WHILE
CONNECTED TO A POWER
SOURCE
2. Place the fan on level ground in a safe, desired position then connect to an approved power source.
NOTE: This model CAN NOT be wall mounted.
Figure 10: Exploded View of PT-24-DDF / PT-24-DDF-F
Replacement Parts
Item # Description Part Number
1 Logo Plate 95-043-0410 2 Front Guard 95-032-0170 3
Fan Blade Assembly 95-003-06214 5 6 Rubber Washer A 95-077-0100 7 Rubber Washer B 95-077-0110 8 Barrel 95-001-0300 9 Handle 95-006-0210
10 Rear Guard 95-032-0270 11 Motor 95-030-0530 12 Switch Holder 95-031-0320
© 2013, Pinnacle Products International, Inc. 11 HVF Air Circulator User’s Manual
Item # Description Part Number
13 Switch 95-031-0130 14 Cord Bushing 95-026-0170 15 Switch Cover 95-031-0520 16 Control Knob 95-027-0120 17 Power Cord 95-026-0250 18 Capacitor 95-004-0230 19 Foot 95-023-0210 20 Pipe Frame L/R 95-009-0500 21 Frame Bracket A 95-009-0510 22 Frame Bracket B 95-009-0520 23 Wheel Bolt 95-008-0310 24 Wheel 95-008-0110
Page 12
24’’ OMNI DIRECTIONAL FAN: PT-24O-DDF
Installation and Assembly
1. Place the fan on level ground in a safe, desired position then connect to an approved power source.
Exploded View
3
1
2
4
5
10
8
6
7
9
11
12
13
NEVER LEAVE A FAN
UNATTENDED WHILE
OPERATING OR WHILE
CONNECTED TO A POWER
SOURCE
16
15
17
14
19
18
30
31
Figure 11: Exploded View of: PT-24O-DDF
Replacement Parts
Item # Description Part Number
1 Front Guard 95-032-0170 2 Fan Barrel 95-001-0400 3 Power Knob 95-027-0130 4 Power Knob Holder 95-031-0325 5 Capacitor 95-004-0235 6 Power Cord 95-026-0255 7 Motor 95-030-0535 8 Motor Mount Assembly 95-030-0555 9 Motor Cooling Fan 95-030-0556
10 Fan Blade Assembly 95-003-0621 11 Rear Guard 95-032-0275 12 Front Leg 95-009-0600 13 Horizontal Adj. Knob 95-015-0150 14 Spacer 95-050-0200 15 Outer Ring Frame 95-024-0320
20
29
28
27
26
25
22
23
24
Item # Description Part Number
16 Vertical Adj. Knob 95-015-0150 17 Wall Mount 95-078-0200 18 Handle Pad 95-007-0100 19 Spacer 95-050-0200 20 Handle Arm 95-006-0300 21 Rear Leg 95-009-0610 22 Large Base Cap 95-024-0410 23 Large Base 95-024-0400 24 Foot Pad 95-023-0240 25 Wall Bracket - L 95-077-0100 26 Wall Bracket - R 95-077-0110 27 Small Base 95-024-0500 28 Small Base Cap 95-024-0510 29 Wheel 95-004-0155 30 Lower Mount 95-024-0325 31 Logo Plate 95-043-0331
21
© 2013, Pinnacle Products International, Inc. 12 HVF Air Circulator User’s Manual
Page 13
CONNECTED TO A POWER
WARNING
24” OMNI FAN - OPTIONAL WALL MOUNT
NEVER LEAVE A FAN
UNATTENDED WHILE
OPERATING OR WHILE
SOURCE
Wall Mount Installation
1. Attach Wall Mount (Item #17*) to wood stud as shown below.
2. Slide Wall Bracket L (Item #25*) and Wall Bracket R (Item #26*) on Large Base (Item #23*) onto Wall Mount.
* On Page 12
Wall Mount (Item #17*)
The installer MUST be
certain that the support bracket is mounted to a minimum of a 2x4” stud, and that it is able to support 105 pounds continuously.
Tools Needed
-Flat head Screw Driver.
2”x4”
STUD
Figure 12: Wall Mount installation Close Up
Handle Arm (Item #20*)
Wall
Large Base (Item #23*)
Wall Mount (Item #17*)
Figure 13: Wall Mount installation
© 2013, Pinnacle Products International, Inc. 13 HVF Air Circulator User’s Manual
Page 14
30” FLOOR FAN: PT-30-DDF
NEVER LEAVE A FAN
UNATTENDED WHILE
OPERATING OR WHILE
CONNECTED TO A POWER
SOURCE
Installation and Assembly
1. Place the fan on level ground in a safe, desired position then connect to an approved power source.
Exploded View
1
2
4
7
8
9
6
5
NOTE: This fan uses a folding wheel design. For quick
assembly, simply swing the wheels out and snap to
lock in place.
10
25
15
16
19
17
22
11
18
21
20
23
24
3
25
12
Figure 14: Exploded View of PT-30-DDF
Replacement Parts
Item# Description Part Number
1 Front Guard 95-032-0140 2 Front Swivel Bracket 95-050-0100 3 Fan Blade Assy 95-003-0501 4 Motor 95-030-0500 5 Frame Foot 95-023-0200 6 Cart Frame 95-009-0400 7 Swivel Cover 95-050-0106 8 Frame Swivel Bracket 95-050-0111
9 Frame Upper Swivel Latch 95-050-0120 10 Swivel Latch Pin 95-050-0131 11 Frame Cap 95-011-0300 12 Wheel 95-008-0165
13
14
Item# Description Part Number
13 Wheel Axle 95-008-0260 14 Wheel Frame 95-008-0500 15 Upper Swivel Housing 95-050-0141 16 Frame Lower Swivel Latch 95-050-0150 17 Latch Spring 95-060-0155 18 Lower Swivel Housing 95-050-0161 19 Rear Guard 95-032-0240 20 Rear Swivel Bracket 95-050-0170 21 Capacitor 95-004-0200 22 Power Switch 95-025-0500 23 Rear Motor Cover 95-048-0100 24 Power Cord 95-026-0150 25 Guard Screw 95-033-0225
© 2013, Pinnacle Products International, Inc. 14 HVF Air Circulator User’s Manual
Page 15
NEVER LEAVE A FAN
WARNING
UNATTENDED WHILE
OPERATING OR WHILE
CONNECTED TO A POWER
30” FLOOR FAN - OPTIONAL CEILING MOUNT
SOURCE
Ceiling Mount Installation
MOUNTING BRACKET INSTALLATION:
1. Remove Wheel Frame (Item #15)
2. Attach Cart Frame to Ceiling beam using U-bolts (Item #5).
3. Assemble and attach Ceiling Mount Assembly as shown in Figure 15 below.
Tools Needed
- Phillips and flat head screw driver.
- 10 mm adjustable wrench.
Ceiling Kit Exploded View
3
5
2
4
1
The installer MUST be
certain that the support bracket is mounted to a minimum of a 2x4” stud, and that it is able to support 105 pounds continuously.
This 30” Floor Fan (PT-30-DDF) is approved for use with California’s BAR-97 Emissions Inspection System and meets
all BAR-97(EIS) required specications and standards
6
7
8
9
Figure 15: Exploded View of PT-30-DDF (ceiling mount kit)
Ceiling Kit Replacement Parts
Item# Description Part Number
1 Safety Cable Assy 95-060-0100 2 Nut for Ceiling Swivel Pin 95-060-0180 3 Nut 95-060-0125 4 Upper Ceiling Bracket 95-060-0110 5 U-Bolt 95-060-0120
Item# Description Part Number
6 Top Washer 95-060-0120 7 Lower Ceiling Bracket 95-060-0160 8 Tapping Screw 5-15mm 95-060-0195 9 Ceiling Swivel Pin 95-060-0170
© 2013, Pinnacle Products International, Inc. 15 HVF Air Circulator User’s Manual
Page 16
30” FLOOR FAN - OPTIONAL CEILING MOUNT CONTINUED
WARNING
Ceiling Mount Installation
SAFETY CABLE INSTALLATION:
1. After the fan is securely mounted, feed the safety cable between one of the swivel brackets as shown in Figure
15.
2. Pull safety cable through and secure cable with safety cable U-bolt as shown in Figure 17.
3. Take other end of cable and wrap around beam
4. Secure cable loop as shown in step 2. Be sure there is approximately 2 inches of slack in the safety cable once both ends are secured.
5. Repeat on other side of fan so there are two safety cables.
NEVER LEAVE A FAN
UNATTENDED WHILE
OPERATING OR WHILE
CONNECTED TO A POWER
SOURCE
Tools Needed
- Phillips and flat head screw driver.
- 10 mm adjustable wrench
The installer MUST be
certain that the support bracket is mounted to a minimum of a 2x4” stud, and that it is able to support 105 pounds continuously.
Figure 16: Safety Cable Installation
© 2013, Pinnacle Products International, Inc. 16 HVF Air Circulator User’s Manual
Figure 17: Safety Cable Installation - Close Up
Page 17
NEVER LEAVE A FAN
CAUTION
UNATTENDED WHILE
OPERATING OR WHILE
CONNECTED TO A POWER
30” PEDESTAL FAN: PT-30P-DDF-A, PT-30P-DDF-AF
SOURCE
Installation and Assembly
Tools Needed:
Pliers
Phillips head screwdriver Flat head screwdriver 10mm / adjustable wrench 6mm hex wrench (included)
Parts Included In Box:
(1) Rubber Base Ring
(1) Base
(1) Front Guard (1) Rear Guard (1) Motor Assembly (1) Fan Blade Assembly
(1) Spring (1) Support Pole Assembly
Machine Screw
Pivot Bolt
Tilt
Adjustment
Knob
Upper Support Pole
Motor Assembly
Motor Support Assembly
Wing Nut
Nut
1. Attach Rubber Base Ring (Item #16*) to outer edge of
Base (Item # 5*). Be sure ribbed side of Base Ring is facing down.
2. Remove 5 screws from Flange on bottom of Lower
Support Pole (Item #13*).
3. Completely extend Upper Support Pole (Item #21*)
from Lower Support Pole and insert Spring into bottom of Lower Support Pole.
4. Attach Support Pole Assembly to Base. Tighten
hardware using star pattern to insure a tight, uniform fit.
5. Stand assembly on Base, and press down Upper
Support Pole and then tighten Height Adjustment Knob (Item #3*).
6. Attach Motor Support Assembly to Motor Assembly
(see Figure 18).
7. Place Motor Support into Upper Support Pole.
- Insert Pivot Bolt and tighten.
- Insert Tilt Adjustment Knob and tighten.
8. Remove 4 screws on motor, and attach the Rear Guard.
Tighten screws only after all 4 screws are reattached to the motor.
9. Remove the screws on the Motor and attach the Rear
Guard onto groove in motor shaft, and replace screws (See Figure 19).
10. Loosen the set screw on the back of the Fan Blade
Assembly and slide onto the motor shaft.
11. Position set screw over flat groove on motor shaft an
tighten set screw using 6mm hex wrench (included). Be
Do NOT slide fan blade screw
beyond the groove on the shaft! This will cause the fan blade to not spin properly and can cause damage to your fan! Be sure that fan shaft is flush with front of fan blade assembly.
Figure 18: Attaching Motor to Motor Support Assembly
Figure 19: Attaching Rear Guard to Motor
© 2013, Pinnacle Products International, Inc. 17 HVF Air Circulator User’s Manual
Rear Guard
Motor
sure set screw is on the groove, and the front of Fan Blade Assembly is flush with front of shaft before tightening.
12. Attach Front Guard by first aligning the top hooks of
the Front Guard onto the top of the Rear Guard edge. Work your way around the Guard, placing the Front Guard hooks over the Rear Guard edge. If necessary, use a flat head screwdriver to help pry the Front Guard hooks over the Rear Guard edge. Continue until all hooks are completely attached to the Rear Guard edge.
NOTE: This model CAN NOT be wall mounted
* On Page 18
Page 18
Exploded View
NEVER LEAVE A FAN
UNATTENDED WHILE
OPERATING OR WHILE
CONNECTED TO A POWER
SOURCE
30” PEDESTAL FAN
6
4
5
9
8
23
2
7
1
22
11
3
10
13
17
12
19
14
15
Figure 20: Exploded View of PT-30P-DDF-A / PT-30P-DDF-AF
16
Replacement Parts
Item # Description Part Number
1 Logo Plate 95-043-0340 2 Front Guard 95-032-0181 3 Height Adjustment Knob 95-015-0205 4
Fan Blade Assembly 95-003-06315 6 7 Power Switch (Chain) 95-031-0140 8 Motor Assembly 95-030-0545 9 Rear Guard 95-032-0281
10 Height Adjust. Knob Nut 95-015-0215 11 Pipe Ring 95-017-0215 12 Pipe Support 95-017-0220
18
20
21
Item # Description Part Number
13 Lower Support Pole 95-017-0205 14 Latch Spring 95-060-0210 15 Upper Base 95-024-0225
Lower Base (Rubber
16
Base Ring)
95-024-0235
17 Motor Support 95-030-0560 18 Left Support 95-030-0570 19 Right Support 95-030-0575 20 Tilt Adjustment Knob 95-015-0210 21 Upper Support Pole 95-010-0305 22 Power Cord 95-026-0260 23 Capacitor 95-004-0240
© 2013, Pinnacle Products International, Inc. 18 HVF Air Circulator User’s Manual
Page 19
Troubleshooting Guide
Problem Possible Cause Corrective Action
NEVER LEAVE A FAN
UNATTENDED WHILE
OPERATING OR WHILE
CONNECTED TO A POWER
SOURCE
Fan does not operate
Reduced Air Flow
Humming sound but no operation
Excess Noise (vibration, squealing)
1. No power
2. Bad motor Replace motor
1. Obstruction
2. Bad switch or capacitor
1. Bad capacitor Replace capacitor
1. Fan is not on level ground Turn off fan, and move unit to smooth level surface.
2. Guard is not secure Check guard screws to be sure all are tight.
Inspect power cord for damage. Be sure unit is plugged in and turned on.
Turn off and unplug fan. Remove guard and make sure nothing is obstructing the fan blades.
Replace switch or capacitor (Note: To prolong life of fan, operate fan first in 1(LOW) for 5-10 seconds before switching to higher speed.
© 2013, Pinnacle Products International, Inc. 19 HVF Air Circulator User’s Manual
Page 20
1 YEAR LIMITED WARRANTY
PINNACLE PRODUCTS INTERNATIONAL, INC. WARRANTS THIS
PRODUCT TO THE ORIGINAL RETAIL PURCHASER ONLY, TO BE FREE FROM DEFECTS IN MATERIAL AND WORKMANSHIP FOR A PERIOD OF ONE (1) YEAR FROM THE DATE OF INITIAL PUR­CHASE. THIS PRODUCT MUST BE PROPERLY INSTALLED, MAIN­TAINED AND OPERATED IN ACCORDANCE WITH THE INSTRUC­TIONS PROVIDED.
PINNACLE PRODUCTS INTERNATIONAL, INC. REQUIRES REA- SONABLE PROOF OF YOUR DATE OF PURCHASE FROM AN AUTHORIZED RETAILER OR DISTRIBUTOR. THEREFORE, YOU SHOULD KEEP YOUR SALES SLIP, INVOICE, OR CANCELLED CHECK FROM THE ORIGINAL PURCHASE. THIS LIMITED WARRANTY SHALL BE LIMITED TO THE REPAIR OR REPLACEMENT OF PARTS, WHICH PROVE DEFECTIVE UNDER NORMAL USE AND SERVICE WITHIN THE WARRANTY PERIOD, AND WHICH PINNACLE PRODUCTS INTERNATIONAL, INC. SHALL DETERMINE AT ITS REASONABLE DISCRETION.
THIS WARRANTY DOES NOT APPLY TO PRODUCTS PURCHASED FOR RENTAL USE.
THIS LIMITED WARRANTY DOES NOT COVER REPLACEMENT OF BELTS OR TIGHTENING OF BELTS, OR ANY FAILURES OR OPERATING DIFFICULTIES DUE TO NORMAL WEAR AND TEAR, ACCIDENT, ABUSE, MISUSE, ALTERATION, MISAPPLICATION, IMPROPER INSTALLATION OR IMPROPER MAINTENANCE AND SERVICE BY YOU OR ANY THIRD PARTY. FAILURE TO PERFORM NORMAL AND ROUTINE MAINTENANCE ON THE FAN, SHIPPING DAMAGE, DAMAGE RELATED TO INSECTS, BIRDS, OR ANIMALS OF ANY KIND, AND DAMAGE DUE TO WEATHER CONDITIONS ARE ALSO NOT COVERED. IN ADDI­TION, THE LIMITED WARRANTY DOES NOT COVER DAMAGE TO THE FINISH, SUCH AS SCRATCHES, DENTS, DISCOLORATION, RUST OR OTHER WEATHER DAMAGE, AFTER PURCHASE. ALL TRANSPORTATION COSTS FOR THE RETURN OF THE DAM­AGED PRODUCT OR PARTS WILL BE THE RESPONSIBILITY OF THE PURCHASER. UPON RECEIPT OF DAM­AGED ITEM, PINNACLE PRODUCTS INTERNATIONAL, INC. WILL EXAMINE THE ITEM AND DETERMINE IF DEFECTIVE.
NEVER LEAVE A FAN
UNATTENDED WHILE
OPERATING OR WHILE
CONNECTED TO A POWER
SOURCE
PINNACLE PRODUCTS INTERNATIONAL, INC. WILL REPAIR
OR REPLACE AND RETURN THE ITEM, FREIGHT PRE-PAID. IF PINNACLE PRODUCTS INTERNATIONAL, INC. FINDS THE ITEM TO BE IN NORMAL OPERATING CONDITION, OR NOT DEFEC­TIVE, THE ITEM WILL BE RETURNED FREIGHT COLLECT.
THIS LIMITED WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES. PINNACLE PRODUCTS INTERNATIONAL, INC. DISCLAIMS ALL WARRANTIES FOR PRODUCTS THAT ARE PUR­CHASED FROM SELLERS OTHER THAN AUTHORIZED RETAIL­ERS OR DISTRIBUTORS.
AFTER THE PERIOD OF THE ONE (1) YEAR LIMITED WARRANTY EXPIRES, PINNACLE PRODUCTS INTERNATIONAL, INC. DISCLAIMS ANY AND ALL IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR APPLICATION. FURTHER, PINNACLE PRODUCTS INTERNATIONAL, INC. SHALL HAVE NO LIABILITY WHATSOEVER TO PURCHASER OR ANY THIRD PARTY FOR ANY SPECIAL, INDIRECT, PUNITIVE, INCIDENTAL, OR CONSEQUENTIAL DAMAGES. PINNACLE PRODUCTS INTERNATIONAL, INC. ASSUMES NO RESPONSIBILITY FOR ANY DEFECTS CAUSED BY THIRD PAR­TIES. THIS LIMITED WARRANTY GIVES THE PURCHASER SPECIFIC LEGAL RIGHTS; A PURCHASER MAY HAVE OTHER RIGHTS DEPENDING UPON WHERE HE OR SHE LIVES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMI­TATION OF SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES, OR LIMITATIONS ON HOW LONG A WARRANTY LASTS, SO THE ABOVE EXCLUSION AND LIMITA­TIONS MAY NOT APPLY TO YOU.
PINNACLE PRODUCTS INTERNATIONAL, INC. DOES NOT AUTHORIZE ANY PERSON OR COMPANY TO ASSUME FOR IT ANY OTHER OBLIGATION OR LIABILITY IN CONNECTION WITH THE SALE, INSTALLATION, USE, REMOVAL, RETURN, OR REPLACEMENT OF ITS EQUIPMENT, AND NO SUCH REP­RESENTATIONS ARE BINDING ON PINNACLE PRODUCTS
INTERNATIONAL, INC.
Register Online at: www.protemp.us/Product_Registration.php
ALWAYS BE SURE TO SPECIFY MODEL NUMBER AND SERIAL NUMBER WHEN MAKING ANY CLAIM WITH PINNACLE PRODUCTS INTERNATIONAL, INC. FOR YOUR CONVENIENCE USE THE SPACE PROVIDED BELOW TO LIST THIS INFORMATION:
Model #: ____________________ Serial #: ______________________
Date of Purchase: _________________
© Pinnacle Products International, Inc.
668 Stony Hill Road #302 Yardley, PA 19067 USA Toll Free: (800) 641-6996
Fax: (215) 891-8461 • Web: www.protemp.us • Email: info@pinnacleint.com
Loading...