PROTEK PLC01-6 Datasheet

05071
Only One Name Means ProTek’Tion™
APPLICATIONS
T1/E1 Line CardsISDN Telecom EquipmentxDSL, USB, SCSI & Ethernet InterfacesCellular Base StationsData & Bus Lines for FCC Part 68 Applications
IEC COMPATIBILITY (EN61000-4)
PLC01-6
LOW CAPACITANCE TVS ARRAY
61000-4-2 (ESD): Air - 15kV, Contact - 8kV61000-4-4 (EFT): 40A - 5/50ns61000-4-5 (Surge): 48A, 8/20µs, L3(Line-Gnd), L4(Line-Line) & L1(Power)
FEATURES
ESD PROTECTION > 40 kilovolts
1,500 Watts Peak Pulse Power per Line (tp=10/1000µs)Low Clamping Voltage100A (10/1000µs) per Bellcore 1089(Intra-Building)200A (10/160µs) per FCC Part 68Bidirectional ConfigurationProtects 1 Line
MECHANICAL CHARACTERISTICS
Molded JEDEC SO-16 (Wide Body) PackageWeight 0.15 grams (Approximate)Flammability rating UL 94V-016mm Tape and Reel Per EIA Standard 481Marking: Logo, Part Number, Date Code & Pin One Defined By Dot on Top of Package
SO-16
(Wide Body)
16
PIN CONFIGURATION
15
1
2
14
3
13
4
12
5
105071.R4 8/03 www.protekdevices.com
11
6
10
78
9
DEVICE CHARACTERISTICS
MAXIMUM RATINGS @ 25°C Unless Otherwise Specified
PLC01-6
PARAMETER Peak Pulse Power (td = 10/1000µs) - See Figure 1 Operating Temperature Storage Temperature
SYMBOL VALUE
P
PP
T
J
T
STG
1,500 Watts
-55°C to 150°C
-55°C to 150°C
ELECTRICAL CHARACTERISTICS PER LINE @ 25°C Unless Otherwise Specified
PA RT
NUMBER
(See Note 1)
PLC01-6
Note 1: Electrical characteristics apply from pins 13-16 to 1-4 and 5-8 to 9-12; see circuit diagram. Note 2: VC tested at 10/1000µs impulse waveform. Note 3: 10/160µs impulse waveform per FCC Part 68.
RATED
STAND-OFF
VOLTAGE
V
WM
VOLTS
6.0 8.0
MINIMUM
BREAKDOWN
VOLTAGE
@ 1mA
V
(BR)
VOLTS
MAXIMUM
CLAMPING
VOLTAGE
(See Note 2)
@ IP = 100A
V
C
VOLTS
15.0
MAXIMUM
CLAMPING
VOLTAGE
MAXIMUM
LEAKAGE
CURRENT
(See Note 3)
@ IP = 200A
V
C
16.0 50
@V
µA 25
WM
I
D
UNITS
°C °C
TYPICAL
CAPACITANCE
@0V, 1 MHz
C
pF
2 www.protekdevices.com05071.R4 8/03