Operating and Installation Instructions ProTect Safes Grad S2
1. Scope of delivery
The delivery comprises:
For models with electronic locks – operating instructions for the safe, operating instructions for the lock, anchor
bolt.
For models with key locks – 2 keys for the outer door, operating instructions for the safe, anchor bolt.
2. Installation of the safe
Important: Please check the bearing capacity of the floor prior to installing the safe. The floor must
indicate at least the weight of the safe per square metre.
The concrete should have a crushing strength of up to 30Nm (4,350psi) and should be reinforced with
reinforcing steel with a diameter of at least 8mm and a mesh spacing of 150mm.
(Generally, a floor bearing capacity of at least 0.5kg/cm² is applicable for all types of safes.) It is
recommended to be very careful when installing the safe. Prior to bolting the door should be opened and
closed for a few times to ensure functionality. In case the safe is to be bolted to the floor, the open door
should be lined with appropriate materials to prevent the risks associated with tipping of the safe.
1. Mark the bore hole positions.
2. Drill the holes in accordance with your anchor bolt and the table in item 7.
3. Remove dust and place the anchor (without the bolt) into the bore hole.
4. Align the safe to the bore hole.
5. Secure the safe on the floor using the anchor bolt (the use of a torque wrench with the setting 30Nm is
recommended).
6. Press the plastic cover onto the anchor bolt.
7.

Länge (L) des
Ankerbolzens in
mm
Durchmesser (d)
des Bohrers in
mm
Minimale Tiefe(m)
der Durchbohrung
in mm
Minimale Tiefe (h)
der Einsetzung in
mm
3. Using the safe and validity of the certificate
If the safe has not been anchored in accordance with the prescribed procedure and is damaged by fire, a break-in
attempt or incorrect usage, the certificate of the safe will be void.
4. Troubleshooting
If the safe has been damaged or if you lost a key, please contact your dealer or dial the following service number
+49 (0) 221-88081930.
5. Maintenance
The hinges should be lightly lubricated at the appropriate points on a yearly basis.
6. Service
Please contact your dealer or dial the following service number
Service number: P: +49 (0) 221-88081930
7. Technical features of ProTect Safe Security level S2
Gaia
Modell
S2-100 300 445 400 220 365 296 24 26 1 0
S2-120 450 445 400 370 365 296 40 35 1 4
S2-140 600 445 400 520 365 296 56 43 1 4
S2-160 800 445 400 720 365 296 78 55 2 8
S2-180 1000 445 400 920 365 296 99 65 2 8
mm
Kg
mm mm mm mm mm
( )
V
I
* - allowed tolerance +/–10% of the weight of the products listed in the table

Modell
S2-100 300 427 385 170 316 235 13 49 1 0
S2-120 315 445 450 185 335 300 19 57 1 0
S2-140 460 440 450 330 330 300 32 71 1 4
S2-160 490 360 450 360 249 300 27 66 1 3
S2-180 670 440 450 540 330 300 53 96 1 4
S2-200 950 440 450 822 330 300 81 127 2 8
mm
Kg
mm mm mm mm mm
( )
V
I
* - allowed tolerance +/–10% of the weight of the products listed in the table
Chronos 60P
Modell
S2-220 345 480 460 185 332 300 18 66 1 0
S2-240 490 480 460 330 332 300 33 85 1 4
S2-260 670 480 460 510 332 300 51 108 1 4
mm
Kg
mm mm mm mm mm
I
(
)
V
* - allowed tolerance +/–10% of the weight of the products listed in the table
Erebos
Modell
OB-180 1220 930 520 1050 820 405 349 90 2 30
OB-200 1950 1250 520 1780 1140 405 822 200 4 70
OB-220 1950 930 520 1800 820 420 638 142 4 50
S2-100 1950 940 585 1760 801 392 553 457 4 50
S2-120 1200 1250 585 1030 1110 390 445 440 2 39
S2-140 1950 1250 585 1785 1110 390 773 650 4 65
1-160 1950 940 585 1760 801 392 553 658 4 50
mm
Kg
mm mm mm mm mm
( )
V
I
* - allowed tolerance +/–10% of the weight of the products listed in the table
If your model is not be listed in the table, please contact the service number given
in item 6 for further information.
Important! Under certain circumstances the internal dimensions of the safes
may be reduced due to integrated alarm systems.