protech PIRAMID XL3 Installation Instructions Manual

Page 1
US
PIRAMID XL3
Installation instructions - Pages 1-28
529 VISTA BLVD 89434 SPARKS, NV - USA
Toll Free: 1-800-498-9662 / Phone: (775) 856-7333 / Fax: (775) 856-7658 Website: www.protechusa.com E-mail: sales@protechusa.com
NT412 / V1.2 / 09.18
Page 2
Page 3
PROTECH PIRAMID XL3
CONTENTS
1
GENERAL .............................................................................................................2
2
DESCRIPTION ......................................................................................................3
3
OPERATION .........................................................................................................4
4
INSTALLATION PRECAUTIONS ..........................................................................6
5
INSTALLATION .................................................................................................. 10
6
WIRING ............................................................................................................... 11
6.1 Wiring PIRAMID XL3 ........................................................................................................... 11
6.2 Maximum length of 12VDC power supply cables ................................................................. 12
7
SET-UP ............................................................................................................... 12
7.1 Settings PIRAMID XL3 ......................................................................................................... 12
7.2 Anti-masking alarm .............................................................................................................. 15
7.3 Reading the parameters of the PIRAMID XL3: "READ" Mode ............................................. 16
8
SMARTPHONE APPLICATION .......................................................................... 17
8.1 Managing settings ................................................................................................................ 19
8.2 PIRAMID XL3 settings ......................................................................................................... 19
8.3 Real-time Information ........................................................................................................... 21
8.4 Event log .............................................................................................................................. 22
9
PERIODIC MAINTENANCE ................................................................................ 24
10 MAINTENANCE .................................................................................................. 24
11 TECHNICAL SPECIFICATIONS ......................................................................... 25
12 PRODUCT REFERENCES .................................................................................. 26
- 1 -
Page 4
PROTECH PIRAMID XL3
1 GENERAL
PIRAMID XL3 is a dual-technology sensor:
A passive infrared unit composed of a pyroelectric infrared (PIR) sensor that detects radiation emitted by the human body in the infrared spectrum.
A Microwave antenna using a 10,510 GHz frequency transmitter and a Doppler Effect receiver detect changes in the state of the radiation field caused by passage of an object or body in the lobe created by the antenna.
The detection zone formed by the lobe of the microwave antenna and the beams from the mirror of the PIR create an invisible detection zone. To trigger an alarm, it is necessary that the object or intruder pass through the detection zone.
MAIN FEATURES:
Maximum outdoor range: SDI-78XL3-A: 98ft x 98ft / 30m x 30m SDI-78XL3-B: 98ft x 33ft / 30m x 10m SDI-78XL3-C: 131ft x 19.7ft / 40m x 6m SDI-78XL3-D: 131ft x 9.8ft / 40m x 3m SDI-78XL3-H: 98ft x 85ft / 30m x 26m SDI-78XL3-H60: 98ft x 46ft / 30m x 14m SDI-78XL3-H40: 98ft x 23ft / 30m x 7m SDI-78XL3-H20: 98ft x 9.8ft / 30m x 3m
Horizontal orientation +/- 90° in 10° increments. Vertical orientation from 0° to -10°
maximum.
Anti-masking function by infrared Led.
- 2 -
Page 5
PROTECH PIRAMID XL3
2 DESCRIPTION
Front view Back view
Top view Side view
PIR Lens
MW antenna cover
- 3 -
Page 6
Side view
lens A
98 ft / 30
m
33 ft /
1
0 m
98 ft / 30
m
19.7 ft / 6 m
9.8 ft
/ 3 m
PROTECH PIRAMID XL3
3 OPERATION
Characteristics of detection zone:
SDI-78XL3-A SDI-78XL3-B
Top view
Top view
Side view lens B
98 ft / 30 m
Side view lens B-Pet
Side view lens A-Pet
SDI-78XL3-C SDI-78XL3-D
Top view
131 ft / 40 m
Side view lens C
Side view lens C-Pet
Top view
131 ft / 40 m
Side view lens D
Legend:
PIR detection zone MW detection zone
- 4 -
Page 7
85.3 ft / 26
m
Side view
45.9 ft / 14
m
23 ft / 7
m
Side view
3
m
PROTECH PIRAMID XL3
SDI-78XL3-H SDI-78XL3-H60
Top view
Top view
98.4 ft / 30 m
98.4 ft / 30 m
Side view
SDI-78XL3-H40 SDI-78XL3-H20
Top view
Top view
98.4 ft / 30 m
98.4 ft / 30 m
Side view
Legend:
PIR detection zone MW detection zone
- 5 -
Page 8
PROTECH PIRAMID XL3
4 INSTALLATION PRECAUTIONS
It is important to follow certain rules to ensure proper installation of the detector:
-
ENSURE THAT NO VEGETATION IS FOUND IN THE DETECTION ZONE. CHECK THAT THE CLOSEST VEGETATION DOES NOT OBSTRUCT THE DETECTION ZONE IN CASE OF WIND.
DON’T DO
-
RESPECT THE RECOMMENDED INSTALLATION HEIGHT.
6.6ft and 13ft / 2m and 4m
Installation height must be between
- 6 -
Page 9
ount the detector on a wall or solid post
If it is installed on a building with a metal surface,
PROTECH PIRAMID XL3
-
INSTALL THE DETECTOR ON A STABLE MOUNTING SURFACE
DON’T mount the detector on a surface exposed to strong vibrations, such as a fence with no support or a flimsy metal surface.
DO: M
the support must be vibration-resistant.
Vibration-resistant Support Structure
Vibration-resistant
Support non sensible
Support Structure
aux vibrations
-
USE AS A MOTION DETECTOR AND NOT AS A PERIMETER DETECTOR
DON’T use the PIRAMID XL3 as a perimeter detector. For good transverse detection, the sensitivity must be set to maximum, which risks increasing the number of unwanted alarms triggered.
DO: Use the PIRAMID XL3 as an approach detector (use of A, B or C lenses possible). A low sensitivity setting enables a reduction of the number of unwanted alarms triggered.
DON’T DO
BUILDING BUILDING
-
BE CAREFUL OF WASTE WHICH COULD ATTRACT SMALL ANIMALS AND BIRDS
- 7 -
Page 10
be used as perches
PROTECH PIRAMID XL3
DON’T leave any bin in the range of the
detector which could attract small animals and birds. When they are near to the detector, they may be identified as larger targets by the detector.
fixtures or signage. They can by birds and trigger false alarms.
DON’T DO
Rubbish
-
BE CAREFUL OF BIRDS WHICH COULD PERCH IN THE RANGE OF THE DETECTOR
DON’T install the detector near to lighting
DON’T DO
DO: Place bins away from the range of the
detector.
Rubbish
detector with a range which is free of any obstacles.
DO: Select a location which provides the
- 8 -
Page 11
mount the detector under eaves which
PROTECH PIRAMID XL3
-
BE CAREFUL OF ANIMALS PASSING THROUGH HOLES IN OR DUG UNDER A FENCE
DON’T ignore openings which have been made in a fence and may provide an easy passage for small animals (dogs, cats, raccoons, etc.) in the protected area.
DON’T DO
-
-
WARNING IF INSTALLING THE SENSOR UNDER EAVES
DON’T
are not equipped with a gutter. In the event of heavy rainfall, the flow of water directly in front of the sensor may trigger false alarms.
DON’T DO
DO: Repair holes in the fence (or fill in holes dug underneath) to block access to the protected area.
DO: mount the detector under eaves
provided that they are equipped with a gutter.
- 9 -
Page 12
/ 80mmm
PROTECH PIRAMID XL3
5 INSTALLATION
For optimum performance, the PIRAMID XL3 detector must be installed at a height between
6.6ft / 2m and 13ft / 4m.
Drilling template for wall mounting:
2.4 in
/ 60mm
REQUIRED ACCESSORIES TO MOUNT PIRAMID XL3:
-
4 Screws 4.8x60
-
4 Screw anchors
-
3.2 in
4 Washer Ø5
-
1 Hex key size 6mm
Drilling template for corner mounting:
2,8 in
70 mm
0,4 in
70 mm
10 mm
1
n
i
7
,
m
0
,
7
i
n
9
m
m
m
9
1
2,8 in
- 10 -
Page 13
1: 12V DC
power supply
13:
Tamper
Contact N
C *
2: 0V DC
power
supply
14:
Tamper
Contact NO *
3: Intrusion
alarm contact
NC 15:
Tamper
Contact COM *
4: Intrusion
alarm contact
NO
5: Intrusion
alarm contact
COM
6: Anti
-
masking alarm contact N
C
7:
Anti
-
masking alarm contact
NO
PROTECH PIRAMID XL3
Opening the cover
Loosen the screw, raise, and then pull the cover up.
6 WIRING
6.1 Wiring PIRAMID XL3
8: Anti-masking alarm contact COM
- 11 -
Page 14
/ 5 m
/
10 m
/ 15 m
/ 20 m
/ 25 m
/ 30 m
/ 35 m
/ 40 m
/ 45 m
ALARM LED
PROTECH PIRAMID XL3
6.2 Maximum length of 12VDC power supply cables
(Wire type SYT1 shielded)
Wire
0.02 in
0.04 in
0.06 in
Note: When using the same cable to supply power to several components, the indicated distances should be
divided by the number of connected components. When using several wires with the same section in parallel by polarity, the indicated distances should be multiplied by the number of connected wires.
0.6 mm
0.9 mm
1.4 mm
Wire section Maximum length of cables 23 AWG 20 AWG 16 AWG
0.3 mm²
0.6 mm²
1.5 mm²
0.06 mi 94 m
0.13 mi 211 m
0.29 mi 470 m
7 SET-UP
7.1 Settings PIRAMID XL3
Using the setting mode:
PIR LED MW LED
Code selector setting max. distance
Code selector setting Sensitivity
ALARM LED: lights up when the PIR and MW are in alarm. PIR LED: lights up when the PIR is in alarm. MW LED: lights up when the MW is in alarm.
Code selector max. distance: setting the maximum distance of detection. The detector is insensitive to moving objects beyond this distance.
Code selector sensitivity: setting the sensitivity of the MW.
Low sensitivity High sensitivity
Code selector
value
Distance
1 2 3 4 5 6 7 8 9
16.4 ft
33 ft
49 ft
66 ft
82 ft
98 ft
115 ft
131 ft
- 12 -
147 ft
Page 15
value
PROTECH PIRAMID XL3
1. Turn the “Test Mode” switch to the ON position to change to Settings mode.
2. Set the sensitivity to maximum (code selector set to 9).
Code selector sensitivity setting
3. Set the maximum distance beyond which the PIRAMID XL3 should not detect. Code selector setting
Max. distance
Code selector
1 16.4 ft / 5 m 2 33 ft / 10 m 3 49 ft / 15 m 4 66 ft / 20 m 5 82 ft / 25 m 6 98 ft / 30 m 7 115 ft / 35 m 8 131 ft / 40 m 9 147 ft / 45 m
Distance
Note: On the two code selectors, setting 0 is reserved for rereading the value memorized in the detector. (See §7.3 Reading the parameters of the PIRAMID XL3: "READ" Mode)
- 13 -
Page 16
(PIR + MW)
ALARM
PROTECH PIRAMID XL3
4. Turn the product on, the PIR and MW LEDs will light up when the initiation phase has ended
(5s).
LED
PIR LED
MW LED
5. Determine the desired PIRAMID XL3 detection range by performing walk test in this area.
Adjust detector orientation and sensitivity to the required settings.
When one of the technologies, PIR or MW, switches to alarm status, the associated LED will light up red. When both PIR + MW technologies are in alarm status, the ALARM LED will light up red.
Detector status NO alarm
Alarm PIR Alarm MW
Alarm intrusion
ALARM
LED
LO LO LO
RL
MW LED PIR LED Buzzer *
GL GL RL
RL
GL RL GL
RL
Off Slow beers Rapid beeps
Continuous
Legend:
* If buzzer is enabled in the hub
LO : LED off
RL : Red LED on
- 14 -
GL : Green Led on
Page 17
PROTECH PIRAMID XL3
6. Turn the "Test Mode" to the OFF position to switch to detection mode.
7. Close the cover.
8. In normal operation, the LEDs are off.
It is possible to activate them via smartphone application (see §8.2).
Note: “INTRUSION” and "MASKING” relays remain in alarm status when the "Test Mode" switch is in the ON position.
7.2 Anti-masking alarm
The alarm is triggered when an obstacle obstructs the masking sensor located in the upper cover. (The masking alarm is triggered approximately 15s after the obstacle has been located)
Anti-masking sensor
- 15 -
Page 18
PROTECH PIRAMID XL3
7.3 Reading the parameters of the PIRAMID XL3: "READ" Mode
Sensitivity and distance settings max. can be modified:
-
Either via the code selectors on the detector
-
Or via the smartphone application
Note: In Settings mode, sensitivity and distance settings are stored in memory by the code selectors.
In Detection mode, sensitivity and distance settings are stored in memory either by the application: last backup performed.
To find out the values of stored settings, switch the detector to “READ” mode:
1. Set the code selector to "0".
2. Turn the "Test Mode" switch to ON.
3. The detector LED(s) will blink.
Note: only the LED linked to the code selector set to 0 will blink.
Max distance LED setting
Sensitivity LED setting
Max distance code selector setting
Code selector sensitivity setting
- 16 -
Page 19
Sorhea Connect
PROTECH PIRAMID XL3
4. Turn the code selector until the LED is permanently lit.
The value displayed on the code selector corresponds to the stored setting.
5. Turn the "Test Mode" switch OFF to exit “Read” mode.
8 SMARTPHONE APPLICATION
Note: The smartphone application is compatible from Android 4.1 or higher.
1. Download the “Sorhea Connect” smartphone application.
2. Launch the “Sorhea Connect” application.
Authorize activation of Bluetooth if requested to do so by the application.
3. Check that the tamper switches are turned downwards.
Switches down
- 17 -
Page 20
PROTECH PIRAMID XL3
4. Set a tamper alarm to activate the BLE connection with the smartphone application: leave
the tamper contact pressed down for 2 seconds, then release. Note: the connection remains active for as long as the PIRAMID XL3 is connected to the
smartphone application. It is disconnected when the cover is shut (tamper contact closed) or after 1 minute of inactivity (application closed).
5. Launch the search.
6. Click on the product found.
PIRAMID XL3 Radio ID found is identical to the sticker on the card
PIRAMID XL3 found
Tamper contact
- 18 -
Page 21
PROTECH PIRAMID XL3
8.1 Managing settings
8.2 PIRAMID XL3 settings
1. Click on Menu
2. Click on Settings
Settings
Menu
Setting the time on the PIRAMID XL3
Name of PIRAMID XL3: Click on the name to change it then click on Save.
- 19 -
Page 22
Antimask enabled / disabled
:
PROTECH PIRAMID XL3
3. PIRAMID XL3 settings
LEDS enabled / disabled
Buzzer enabled / disabled
Legend:
Enable Sensor ejected
Disable Sensor not ejected
Relay outputs enabled / disabled
MW ejection PIR ejection
Moving direction:
Settings save above
MW Range settings 1 : 16 ft / 5 m 9 : 148 ft / 45 m
MW Sensitivity settings 1 : Not very sensitive 9 : Very sensitive
Max. speed settings:
0.62 to 31 mph / 1 to 50 km/h
Distance to be covered settings
0.33 to 16 ft / 0.1 to 5m
PIR Sensitivity settings:
1 : Not very sensitive 81 : Very sensitive
MW and PIR settings save
MW range:
Modification of the maximum detection range of the MW
.
MW sensitivity: Max. speed:
Modification of the detection sensitivity of the MW
Modification of the maximum speed to detect of the MW Makes it possible to filter objects for which the speed is superior to the “Speed max.”
Distance of movement:
PIR sensitivity:
Modification of the detection sensitivity of the PIR
.
.
.
Modification of the maximum distance an object has to move before the MW detects it
.
Minimum distance of movement that an object has to move in the same direction before triggering an alarm
.
.
- 20 -
Page 23
PROTECH PIRAMID XL3
8.3 Real-time Information
1. Click on Menu
2. Click on Real-time
Real-time
Menu
3. Viewing PIRAMID XL3 real-time information
MW and PIR sensor status
Intrusion and anti-mask relays status
“Test mode” switch status
: Setting mode
Internal temperature of the PIRAMID XL3 Power supply
Legend:
No Alarm Alarm
: Detection mode
- 21 -
Page 24
PROTECH PIRAMID XL3
8.4 Event log
1. Click on Menu
2. Click on Event log
Event log
Menu
- 22 -
Page 25
− Alarm
intrusion
− Alarm
mask
− Alarm
tamper
− End alarm tamper
− Configuration
− Blocking
event log
− End
de
fault 12V
− End
default MW
− Default radio
card
− MW
ejected
− End
MW
ejected
− End
PIR ejected
− BLE
Connection
PROTECH PIRAMID XL3
3. View event log
Date/Time of the event
Type of events
PIRAMID XL3 setting
List of events:
End alarm mask
Time setting
Power on Raz event log
Unblock event log Default 12V
Default MW
End default radio card
PIR ejected
End BLE Connection
- 23 -
Page 26
Failure
Probable
causes
Solutions
(see §
8.2)
towards the bottom. (see §
8)
PROTECH PIRAMID XL3
9 PERIODIC MAINTENANCE
To guarantee performance over time, basic maintenance operations should be performed to confirm the status of the PIR filter. If necessary, clean the filter with a soft, moist cloth.
10 MAINTENANCE
Default settings:
-
LEDs status : disable (see §8.2 for led settings)
-
Buzzer status : enable (see §8.2 for buzzer settings)
-
Permanent alarm
"Test Mode" switch in the
ON position.
-
Incorrect voltage (<10V)
-
The relays are disabled.
-
Turn the "Test Mode" switch to the
OFF position.
-
Check the power supply.
-
Enable relays via the application
No triggering of the intrusion alarm
Anti-masking alarm in permanent alarm
Permanente tamper alarm
The smartphone application cannot detect the PIRAMID XL3.
-
Passage beyond the
distance set on the code
-
Change the distance set on the
code selector.
selector.
-
The relays are disabled.
-
The anti-masking alarm is
-
Enable relays via application
(see §8.2)
-
Enable the anti-masking alarm
(see §8.2)
disabled.
-
Tamper switches are in up. - If the tamper is to be used in a local
connection, wire the terminals 13,14,15.
-
If the tamper is to be used in a
network connection, turn the switches to the bottom.
-
The PIRAMID XL3 BLE
connection is not activated.
-
Press on the tamper switch for at
least 2 seconds, then release. (see §8)
-
Check that the tamper switches are
- 24 -
Page 27
SDI-78XL3
-
H20:
98ftx9.8ft
/ 30mx3m
Vertical from 0° to
-
10°
PROTECH PIRAMID XL3
11 TECHNICAL SPECIFICATIONS
SDI-78XL3-A: SDI-78XL3-B: SDI-78XL3-C:
Maximum outdoor range
Detection mode PIR sensor and MicroWave antenna Antenna MW frequency 10.510 GHz Power supply voltage 10 to 20V DC Power supply current 80 mA Typical intrusion alarm duration 5 seconds Typical anti-masking alarm duration Duration the sensor is masked NC Tamper relay rating 24VDC – 1A NC Intrusion relay rating 24VDC – 1A NC Anti-masking relay rating 24VDC – 1A Operating temperature -31°F to 158°F / -35°C to +70°C Relative humidity 95% max without condensation Protection Index IP55 Weight 1.98 lb / 0,9 Kg
Electromagnetic compatibility Detector orientation
SDI-78XL3-D: SDI-78XL3-H: SDI-78XL3-H60: SDI-78XL3-H40:
Compliance with European standards
Horizontal: +/- 90° in increments of 10°
98ftx98ft 98ftx33ft 131ftx19.7ft 131ftx9.8ft 98ftx85ft 98ftx46ft 98ftx23ft
(label CE)
/ 30mx30m / 30mx10m / 40mx6m / 40mx3m / 30mx26m / 30mx14m / 30mx7m
External dimensions:
8,6 in 220 mm
6,5 in 165 mm
9,2 in 233 mm
4,1 in 103 mm
- 25 -
Page 28
PROTECH PIRAMID XL3
12 PRODUCT REFERENCES
SDI-78XL3-A range 98x98ft / 30x30m white ref: 60760301
SDI-78XL3-B range 98x33ft / 30x10m white ref: 60760302
SDI-78XL3-C range 131x19.7ft / 40x6m white ref: 60760303
SDI-78XL3-D range 131x9.8ft / 40x3m white ref: 60760304
SDI-78XL3-A PET range 98x98ft / 30x30m white ref: 60760305
SDI-78XL3-B PET range 98x33ft / 30x10m white ref: 60760306
SDI-78XL3-C PET range 131x19.7ft / 40x6m white ref: 60760307
SDI-78XL3-A range 98x98ft / 30x30m gray anthracite ref: 60760401
SDI-78XL3-B range 98x33ft / 30x10m gray anthracite ref: 60760402
SDI-78XL3-C range 131x19.7ft / 40x6m gray anthracite ref: 60760403
SDI-78XL3-D range 131x9.8ft / 40x3m gray anthracite ref: 60760404
SDI-78XL3-A PET range 98x98ft / 30x30m gray anthracite ref: 60760405
SDI-78XL3-B PET range 98x33ft / 30x10m gray anthracite ref: 60760406
SDI-78XL3-C PET range 131x19.7ft / 40x6m gray anthracite ref: 60760407
SDI-78XL3-H range 98ft x 85ft / 30x26m white ref: 60760308
SDI-78XL3-H20 range 98ft x 9.8ft / 30x3m white ref: 60760309
SDI-78XL3-H40 range 98ft x 23ft / 30x7m white ref: 60760310
SDI-78XL3-H60 range 98ft x 46ft / 30x14m white ref: 60760311
SDI-78XL3-H range 98ft x 85ft / 30x26m gray anthracite ref: 60760408
SDI-78XL3-H20 range 98ft x 9.8ft / 30x3m gray anthracite ref: 60760409
SDI-78XL3-H40 range 98ft x 23ft / 30x7m gray anthracite ref: 60760410
SDI-78XL3-H60 range 98ft x 46ft / 30x14m gray anthracite ref: 60760411
Changes or modifications not expressly approved by PROTECH could void the user’s authority to operate the equipment.
FCC Part 15 compliance statement
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on, the user is encouraged to try to correct interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
- 26 -
Page 29
PROTECH PIRAMID XL3
ISED Licence-Exempt Radio Apparatus
This device contains license-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s license-exempt RSS(s). Operation is subject to the following two conditions:
1. This device may not cause interference.
2. This device must accept any interference, including interference that may cause undesired operation of the device.
Appareils radio exempts de licence ISDE
L’émetteur/récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR d’Innovation, Sciences et Développement économique Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes :
1. L’appareil ne doit pas produire de brouillage ;
2. L'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
Radio Frequency (RF) Exposure Compliance of Radiocommunication Apparatus
To satisfy FCC and IC RF Exposure requirements for mobile devices, a separation distance of 20 cm or more should be maintained between the antenna of this device and persons during operation. To ensure compliance, operation at closer than this distance is not recommended. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Pour satisfaire aux exigences FCC et IC concernant l'exposition aux champs RF pour les appareils mobile, une distance de séparation de 20 cm ou plus doit être maintenu entre l'antenne de ce dispositif et les personnes pendant le fonctionnement. Pour assurer la conformité, il est déconseillé d'utiliser cet équipement à une distance inférieure. Cet émetteur ne doit pas être co-situé ou fonctionner conjointement avec une autre antenne ou un autre émetteur
PROTECH hereby declares that the device PIRAMID XL3 is in conformity with the essential requirements of Directive 2014/53/EU. The declaration of conformity can be found at:
www.protechusa.com
-
Frequency Band: 2400-2483.5MHz / Maximum Transmitting Power: 10mW (EIRP)
-
Frequency band: 10.5-10.6GHz / Maximum Transmitting Power: 13mW (EIRP)
- 27 -
Page 30
PROTECH PIRAMID XL3
In compliance with the European environmental directives, this product must not be thrown away but recycled through an appropriate subsidiary.
- 28 -
Loading...