• A passive infrared unit composed of a pyroelectric infrared (PIR) sensor that detects
radiation emitted by the human body in the infrared spectrum.
• A Microwave antenna using a 10,510 GHz frequency transmitter and a Doppler Effect
receiver detect changes in the state of the radiation field caused by passage of an object
or body in the lobe created by the antenna.
The detection zone formed by the lobe of the microwave antenna and the beams from the mirror of
the PIR create an invisible detection zone. To trigger an alarm, it is necessary that the object or
intruder pass through the detection zone.
MAIN FEATURES:
• Maximum outdoor range:
SDI-78XL3-A: 98ft x 98ft / 30m x 30m
SDI-78XL3-B: 98ft x 33ft / 30m x 10m
SDI-78XL3-C: 131ft x 19.7ft / 40m x 6m
SDI-78XL3-D: 131ft x 9.8ft / 40m x 3m
SDI-78XL3-H: 98ft x 85ft / 30m x 26m
SDI-78XL3-H60: 98ft x 46ft / 30m x 14m
SDI-78XL3-H40: 98ft x 23ft / 30m x 7m
SDI-78XL3-H20: 98ft x 9.8ft / 30m x 3m
• Horizontal orientation +/- 90° in 10° increments. Vertical orientation from 0° to -10°
maximum.
• Anti-masking function by infrared Led.
- 2 -
Page 5
PROTECH PIRAMID XL3
2 DESCRIPTION
Front view Back view
Top view Side view
PIR Lens
MW antenna cover
- 3 -
Page 6
Side view
lens A
98 ft / 30
m
33 ft /
1
0 m
98 ft / 30
m
19.7 ft / 6 m
9.8 ft
/ 3 m
PROTECH PIRAMID XL3
3 OPERATION
Characteristics of detection zone:
SDI-78XL3-A SDI-78XL3-B
Top view
Top view
Side view lens B
98 ft / 30 m
Side view lens B-Pet
Side view lens A-Pet
SDI-78XL3-C SDI-78XL3-D
Top view
131 ft / 40 m
Side view lens C
Side view lens C-Pet
Top view
131 ft / 40 m
Side view lens D
Legend:
PIR detection zone MW detection zone
- 4 -
Page 7
85.3 ft / 26
m
Side view
45.9 ft / 14
m
23 ft / 7
m
Side view
3
m
PROTECH PIRAMID XL3
SDI-78XL3-H SDI-78XL3-H60
Top view
Top view
98.4 ft / 30 m
98.4 ft / 30 m
Side view
SDI-78XL3-H40 SDI-78XL3-H20
Top view
Top view
98.4 ft / 30 m
98.4 ft / 30 m
Side view
Legend:
PIR detection zone MW detection zone
- 5 -
Page 8
PROTECH PIRAMID XL3
4 INSTALLATION PRECAUTIONS
It is important to follow certain rules to ensure proper installation of the detector:
-
ENSURE THAT NO VEGETATION IS FOUND IN THE DETECTION ZONE.
CHECK THAT THE CLOSEST VEGETATION DOES NOT OBSTRUCT THE DETECTION
ZONE IN CASE OF WIND.
DON’T DO
-
RESPECT THE RECOMMENDED INSTALLATION HEIGHT.
6.6ft and 13ft / 2m and 4m
Installation height must be between
- 6 -
Page 9
ount the detector on a wall or solid post
If it is installed on a building with a metal surface,
PROTECH PIRAMID XL3
-
INSTALL THE DETECTOR ON A STABLE MOUNTING SURFACE
DON’T mount the detector on a surface
exposed to strong vibrations, such as a fence
with no support or a flimsy metal surface.
DO: M
the support must be vibration-resistant.
Vibration-resistant
Support Structure
Vibration-resistant
Supportnonsensible
Support Structure
auxvibrations
-
USE AS A MOTION DETECTOR AND NOT AS A PERIMETER DETECTOR
DON’T use the PIRAMID XL3 as a perimeter
detector. For good transverse detection, the
sensitivity must be set to maximum, which risks
increasing the number of unwanted alarms
triggered.
DO: Use the PIRAMID XL3 as an approach
detector (use of A, B or C lenses possible). A
low sensitivity setting enables a reduction of the
number of unwanted alarms triggered.
DON’T DO
BUILDING BUILDING
-
BE CAREFUL OF WASTE WHICH COULD ATTRACT SMALL ANIMALS AND BIRDS
- 7 -
Page 10
be used as perches
PROTECH PIRAMID XL3
DON’T leave any bin in the range of the
detector which could attract small animals and
birds. When they are near to the detector, they
may be identified as larger targets by the
detector.
fixtures or signage. They can
by birds and trigger false alarms.
DON’T DO
Rubbish
-
BE CAREFUL OF BIRDS WHICH COULD PERCH IN THE RANGE OF THE DETECTOR
DON’T install the detector near to lighting
DON’T DO
DO: Place bins away from the range of the
detector.
Rubbish
detector with a range which is free of any
obstacles.
DO: Select a location which provides the
- 8 -
Page 11
mount the detector under eaves which
PROTECH PIRAMID XL3
-
BE CAREFUL OF ANIMALS PASSING THROUGH HOLES IN OR DUG UNDER A FENCE
DON’T ignore openings which have been
made in a fence and may provide an easy
passage for small animals (dogs, cats,
raccoons, etc.) in the protected area.
DON’T DO
-
-
WARNING IF INSTALLING THE SENSOR UNDER EAVES
DON’T
are not equipped with a gutter. In the event of
heavy rainfall, the flow of water directly in front of
the sensor may trigger false alarms.
DON’T DO
DO: Repair holes in the fence (or fill in
holes dug underneath) to block access to the
protected area.
DO: mount the detector under eaves
provided that they are equipped with a gutter.
- 9 -
Page 12
/ 80mmm
PROTECH PIRAMID XL3
5 INSTALLATION
For optimum performance, the PIRAMID XL3 detector must be installed at a height between
6.6ft / 2m and 13ft / 4m.
Drilling template for wall mounting:
2.4 in
/ 60mm
REQUIRED ACCESSORIES TO MOUNT
PIRAMID XL3:
-
4 Screws 4.8x60
-
4 Screw anchors
-
3.2 in
4 Washer Ø5
-
1 Hex key size 6mm
Drilling template for corner mounting:
2,8 in
70 mm
0,4 in
70 mm
10 mm
1
n
i
7
,
m
0
,
7
i
n
9
m
m
m
9
1
2,8 in
- 10 -
Page 13
1: 12V DC
power supply
13:
Tamper
Contact N
C *
2: 0V DC
power
supply
14:
Tamper
Contact NO *
3: Intrusion
alarm contact
NC 15:
Tamper
Contact COM *
4: Intrusion
alarm contact
NO
5: Intrusion
alarm contact
COM
6: Anti
-
masking alarm contact N
C
7:
Anti
-
masking alarm contact
NO
PROTECH PIRAMID XL3
Opening the cover
Loosen the screw, raise, and then pull the
cover up.
6 WIRING
6.1 Wiring PIRAMID XL3
8: Anti-masking alarm contact COM
- 11 -
Page 14
/ 5 m
/
10 m
/ 15 m
/ 20 m
/ 25 m
/ 30 m
/ 35 m
/ 40 m
/ 45 m
ALARM LED
PROTECH PIRAMID XL3
6.2 Maximum length of 12VDC power supply cables
(Wire type SYT1 shielded)
∅
Wire
0.02 in
0.04 in
0.06 in
Note: When using the same cable to supply power to several components, the indicated distances should be
divided by the number of connected components. When using several wires with the same section in
parallel by polarity, the indicated distances should be multiplied by the number of connected wires.
0.6 mm
0.9 mm
1.4 mm
Wire section Maximum length of cables
23 AWG
20 AWG
16 AWG
0.3 mm²
0.6 mm²
1.5 mm²
0.06 mi 94 m
0.13 mi 211 m
0.29 mi 470 m
7 SET-UP
7.1 Settings PIRAMID XL3
Using the setting mode:
PIR LED
MW LED
Code selector setting
max. distance
Code selector setting
Sensitivity
ALARM LED: lights up when the PIR and MW are in alarm.
PIR LED: lights up when the PIR is in alarm.
MW LED: lights up when the MW is in alarm.
Code selector max. distance: setting the maximum distance of detection. The detector is insensitive to
moving objects beyond this distance.
Code selector sensitivity: setting the sensitivity of the MW.
Low sensitivity High sensitivity
Code selector
value
Distance
1 2 3 4 5 6 7 8 9
16.4 ft
33 ft
49 ft
66 ft
82 ft
98 ft
115 ft
131 ft
- 12 -
147 ft
Page 15
value
PROTECH PIRAMID XL3
1. Turn the “Test Mode” switch to the ON position to change to Settings mode.
2. Set the sensitivity to maximum (code selector set to 9).
Code selector
sensitivity setting
3. Set the maximum distance beyond which the PIRAMID XL3 should not detect.
Code selector setting
Max. distance
Code selector
1 16.4 ft / 5 m
2 33 ft / 10 m
3 49 ft / 15 m
4 66 ft / 20 m
5 82 ft / 25 m
6 98 ft / 30 m
7 115 ft / 35 m
8 131 ft / 40 m
9 147 ft / 45 m
Distance
Note: On the two code selectors, setting 0 is reserved for rereading the value memorized in the
detector. (See §7.3 Reading the parameters of the PIRAMID XL3: "READ" Mode)
- 13 -
Page 16
(PIR + MW)
ALARM
PROTECH PIRAMID XL3
4. Turn the product on, the PIR and MW LEDs will light up when the initiation phase has ended
(5s).
LED
PIR LED
MW LED
5. Determine the desired PIRAMID XL3 detection range by performing walk test in this area.
Adjust detector orientation and sensitivity to the required settings.
When one of the technologies, PIR or MW, switches to alarm status, the associated LED will light
up red.
When both PIR + MW technologies are in alarm status, the ALARM LED will light up red.
Detector status
NO alarm
Alarm PIR
Alarm MW
Alarm intrusion
ALARM
LED
LO
LO
LO
RL
MW LED PIR LED Buzzer *
GL
GL
RL
RL
GL
RL
GL
RL
Off
Slow beers
Rapid beeps
Continuous
Legend:
* If buzzer is enabled in the hub
LO : LED off
RL : Red LED on
- 14 -
GL : Green Led on
Page 17
PROTECH PIRAMID XL3
6. Turn the "Test Mode" to the OFF position to switch to detection mode.
7. Close the cover.
8. In normal operation, the LEDs are off.
It is possible to activate them via smartphone application (see §8.2).
Note: “INTRUSION” and "MASKING” relays remain in alarm status when the "Test Mode"
switch is in the ON position.
7.2 Anti-masking alarm
The alarm is triggered when an obstacle
obstructs the masking sensor located in the
upper cover.
(The masking alarm is triggered approximately
15s after the obstacle has been located)
Anti-masking sensor
- 15 -
Page 18
PROTECH PIRAMID XL3
7.3 Reading the parameters of the PIRAMID XL3: "READ" Mode
Sensitivity and distance settings max. can be modified:
-
Either via the code selectors on the detector
-
Or via the smartphone application
Note: In Settings mode, sensitivity and distance settings are stored in memory by the code selectors.
In Detection mode, sensitivity and distance settings are stored in memory either by the
application: last backup performed.
To find out the values of stored settings, switch the detector to “READ” mode:
1. Set the code selector to "0".
2. Turn the "Test Mode" switch to ON.
3. The detector LED(s) will blink.
Note: only the LED linked to the code selector set to 0 will blink.
Max distance
LED setting
Sensitivity LED
setting
Max distance code
selector setting
Code selector
sensitivity setting
- 16 -
Page 19
Sorhea Connect
PROTECH PIRAMID XL3
4. Turn the code selector until the LED is permanently lit.
The value displayed on the code selector corresponds to the stored setting.
5. Turn the "Test Mode" switch OFF to exit “Read” mode.
8 SMARTPHONE APPLICATION
Note: The smartphone application is compatible from Android 4.1 or higher.
1. Download the “Sorhea Connect” smartphone application.
2. Launch the “Sorhea Connect” application.
Authorize activation of Bluetooth if requested to do so by the application.
3. Check that the tamper switches are turned downwards.
Switches down
- 17 -
Page 20
PROTECH PIRAMID XL3
4. Set a tamper alarm to activate the BLE connection with the smartphone application: leave
the tamper contact pressed down for 2 seconds, then release.
Note: the connection remains active for as long as the PIRAMID XL3 is connected to the
smartphone application. It is disconnected when the cover is shut (tamper contact closed) or
after 1 minute of inactivity (application closed).
5. Launch the search.
6. Click on the product found.
PIRAMID XL3 Radio ID found is
identical to the sticker on the card
PIRAMID XL3
found
Tamper contact
- 18 -
Page 21
PROTECH PIRAMID XL3
8.1 Managing settings
8.2 PIRAMID XL3 settings
1. Click on Menu
2. Click on Settings
Settings
Menu
Setting the time on the PIRAMID XL3
Name of PIRAMID XL3:
Click on the name to change it then click on
Save.
- 19 -
Page 22
Antimask enabled / disabled
:
PROTECH PIRAMID XL3
3. PIRAMID XL3 settings
LEDS enabled / disabled
Buzzer enabled / disabled
Legend:
Enable
Sensor ejected
Disable
Sensor not ejected
Relay outputs enabled / disabled
MW ejection
PIR ejection
Moving direction:
Settings save above
MW Range settings
1 : 16 ft / 5 m 9 : 148 ft / 45 m
MW Sensitivity settings
1 : Not very sensitive 9 : Very sensitive
Max. speed settings:
0.62 to 31 mph / 1 to 50 km/h
Distance to be covered settings
0.33 to 16 ft / 0.1 to 5m
PIR Sensitivity settings:
1 : Not very sensitive 81 : Very sensitive
MW and PIR settings save
MW range:
Modification of the maximum detection range of the MW
.
MW sensitivity:
Max. speed:
Modification of the detection sensitivity of the MW
Modification of the maximum speed to detect of the MW
Makes it possible to filter objects for which the speed is superior to the “Speed max.”
Distance of movement:
PIR sensitivity:
Modification of the detection sensitivity of the PIR
.
.
.
Modification of the maximum distance an object has to move before the MW
detects it
.
Minimum distance of movement that an object has to move in the same
direction before triggering an alarm
.
.
- 20 -
Page 23
PROTECH PIRAMID XL3
8.3 Real-time Information
1. Click on Menu
2. Click on Real-time
Real-time
Menu
3. Viewing PIRAMID XL3 real-time information
MW and PIR sensor status
Intrusion and anti-mask relays status
“Test mode” switch status
: Setting mode
Internal temperature of the PIRAMID XL3
Power supply
Legend:
No Alarm
Alarm
: Detection mode
- 21 -
Page 24
PROTECH PIRAMID XL3
8.4 Event log
1. Click on Menu
2. Click on Event log
Event log
Menu
- 22 -
Page 25
− Alarm
intrusion
− Alarm
mask
−
− Alarm
tamper
− End alarm tamper
−
− Configuration
−
−
− Blocking
event log
−
−
− End
de
fault 12V
−
− End
default MW
− Default radio
card
−
− MW
ejected
− End
MW
ejected
−
− End
PIR ejected
− BLE
Connection
−
PROTECH PIRAMID XL3
3. View event log
Date/Time of the event
Type of events
PIRAMID XL3 setting
List of events:
End alarm mask
Time setting
Power on
Raz event log
Unblock event log
Default 12V
Default MW
End default radio card
PIR ejected
End BLE Connection
- 23 -
Page 26
Failure
Probable
causes
Solutions
(see §
8.2)
towards the bottom. (see §
8)
PROTECH PIRAMID XL3
9 PERIODIC MAINTENANCE
To guarantee performance over time, basic maintenance operations should be performed to confirm
the status of the PIR filter. If necessary, clean the filter with a soft, moist cloth.
10 MAINTENANCE
Default settings:
-
LEDs status : disable (see §8.2 for led settings)
-
Buzzer status : enable (see §8.2 for buzzer settings)
-
Permanent alarm
"Test Mode" switch in the
ON position.
-
Incorrect voltage (<10V)
-
The relays are disabled.
-
Turn the "Test Mode" switch to the
OFF position.
-
Check the power supply.
-
Enable relays via the application
No triggering of the
intrusion alarm
Anti-masking alarm in
permanent alarm
Permanente tamper
alarm
The smartphone
application cannot
detect the PIRAMID
XL3.
-
Passage beyond the
distance set on the code
-
Change the distance set on the
code selector.
selector.
-
The relays are disabled.
-
The anti-masking alarm is
-
Enable relays via application
(see §8.2)
-
Enable the anti-masking alarm
(see §8.2)
disabled.
-
Tamper switches are in up. - If the tamper is to be used in a local
connection, wire the terminals
13,14,15.
-
If the tamper is to be used in a
network connection, turn the
switches to the bottom.
-
The PIRAMID XL3 BLE
connection is not activated.
-
Press on the tamper switch for at
least 2 seconds, then release.
(see §8)
-
Check that the tamper switches are
- 24 -
Page 27
SDI-78XL3
-
H20:
98ftx9.8ft
/ 30mx3m
Vertical from 0° to
-
10°
PROTECH PIRAMID XL3
11 TECHNICAL SPECIFICATIONS
SDI-78XL3-A:
SDI-78XL3-B:
SDI-78XL3-C:
Maximum outdoor range
Detection mode PIR sensor and MicroWave antenna
Antenna MW frequency 10.510 GHz
Power supply voltage 10 to 20V DC
Power supply current 80 mA
Typical intrusion alarm duration 5 seconds
Typical anti-masking alarm duration Duration the sensor is masked
NC Tamper relay rating 24VDC – 1A
NC Intrusion relay rating 24VDC – 1A
NC Anti-masking relay rating 24VDC – 1A
Operating temperature -31°F to 158°F / -35°C to +70°C
Relative humidity 95% max without condensation
Protection Index IP55
Weight 1.98 lb / 0,9 Kg
SDI-78XL3-A range 98x98ft / 30x30m white ref: 60760301
•
SDI-78XL3-B range 98x33ft / 30x10m white ref: 60760302
•
SDI-78XL3-C range 131x19.7ft / 40x6m white ref: 60760303
•
SDI-78XL3-D range 131x9.8ft / 40x3m white ref: 60760304
•
SDI-78XL3-A PET range 98x98ft / 30x30m white ref: 60760305
•
SDI-78XL3-B PET range 98x33ft / 30x10m white ref: 60760306
•
SDI-78XL3-C PET range 131x19.7ft / 40x6m white ref: 60760307
•
SDI-78XL3-A range 98x98ft / 30x30m gray anthracite ref: 60760401
•
SDI-78XL3-B range 98x33ft / 30x10m gray anthracite ref: 60760402
•
SDI-78XL3-C range 131x19.7ft / 40x6m gray anthracite ref: 60760403
•
SDI-78XL3-D range 131x9.8ft / 40x3m gray anthracite ref: 60760404
•
SDI-78XL3-A PET range 98x98ft / 30x30m gray anthracite ref: 60760405
•
SDI-78XL3-B PET range 98x33ft / 30x10m gray anthracite ref: 60760406
•
SDI-78XL3-C PET range 131x19.7ft / 40x6m gray anthracite ref: 60760407
•
SDI-78XL3-H range 98ft x 85ft / 30x26m white ref: 60760308
•
SDI-78XL3-H20 range 98ft x 9.8ft / 30x3m white ref: 60760309
•
SDI-78XL3-H40 range 98ft x 23ft / 30x7m white ref: 60760310
•
SDI-78XL3-H60 range 98ft x 46ft / 30x14m white ref: 60760311
•
SDI-78XL3-H range 98ft x 85ft / 30x26m gray anthracite ref: 60760408
•
SDI-78XL3-H20 range 98ft x 9.8ft / 30x3m gray anthracite ref: 60760409
•
SDI-78XL3-H40 range 98ft x 23ft / 30x7m gray anthracite ref: 60760410
•
SDI-78XL3-H60 range 98ft x 46ft / 30x14m gray anthracite ref: 60760411
Changes or modifications not expressly approved by PROTECH could void the user’s authority to
operate the equipment.
FCC Part 15 compliance statement
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates uses
and can radiate radio frequency energy and, if not installed and used in accordance with the
instruction, may cause harmful interference to radio communications. However, there is no guarantee
that interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception which can be determined by turning the equipment off and
on, the user is encouraged to try to correct interference by one or more of the following measures:
−
Reorient or relocate the receiving antenna.
−
Increase the separation between the equipment and receiver.
−
Connect the equipment into an outlet on circuit different from that to which the receiver is
connected.
−
Consult the dealer or an experienced radio/TV technician for help.
- 26 -
Page 29
PROTECH PIRAMID XL3
ISED Licence-Exempt Radio Apparatus
This device contains license-exempt transmitter(s)/receiver(s) that comply with Innovation, Science
and Economic Development Canada’s license-exempt RSS(s). Operation is subject to the following
two conditions:
1. This device may not cause interference.
2. This device must accept any interference, including interference that may cause undesired
operation of the device.
Appareils radio exempts de licence ISDE
L’émetteur/récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR
d’Innovation, Sciences et Développement économique Canada applicables aux appareils radio
exempts de licence. L’exploitation est autorisée aux deux conditions suivantes :
1. L’appareil ne doit pas produire de brouillage ;
2. L'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible
d'en compromettre le fonctionnement.
Radio Frequency (RF) Exposure Compliance of Radiocommunication Apparatus
To satisfy FCC and IC RF Exposure requirements for mobile devices, a separation distance of 20 cm
or more should be maintained between the antenna of this device and persons during operation. To
ensure compliance, operation at closer than this distance is not recommended. This transmitter must
not be co-located or operating in conjunction with any other antenna or transmitter.
Pour satisfaire aux exigences FCC et IC concernant l'exposition aux champs RF pour les appareils
mobile, une distance de séparation de 20 cm ou plus doit être maintenu entre l'antenne de ce
dispositif et les personnes pendant le fonctionnement. Pour assurer la conformité, il est déconseillé
d'utiliser cet équipement à une distance inférieure. Cet émetteur ne doit pas être co-situé ou
fonctionner conjointement avec une autre antenne ou un autre émetteur
PROTECH hereby declares that the device PIRAMID XL3 is in conformity with the essential
requirements of Directive 2014/53/EU. The declaration of conformity can be found at:
www.protechusa.com
-
Frequency Band: 2400-2483.5MHz / Maximum Transmitting Power: 10mW (EIRP)
-
Frequency band: 10.5-10.6GHz / Maximum Transmitting Power: 13mW (EIRP)
- 27 -
Page 30
PROTECH PIRAMID XL3
In compliance with the European environmental directives, this product must not be
thrown away but recycled through an appropriate subsidiary.
- 28 -
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.