TM
This document hosted by: www.oldwillknottscales.com
Thank you for purchasing a PROSCALE® LÜR™ digital scale. Please read all operating instructions carefully before use. This electronic scale is a precision instrument. With normal care and proper treatment, it
will provide years of reliable service.
Never load the scale with more than the maximum capacity. Overloading will permanently damage it!
Avoiding any exposure to extreme heat or cold, your scale works better when operated at normal room
temperature. Always allow the scale to acclimate to normal room temperature for at least one hour
before use. Give your scale sucient warm up time. Usually 30-60 seconds to give the internal components a chance to stabilize. Keep your scale in a clean environment. Dust, dirt, moisture, vibration, air
currents and a close distance to other electronic equipment can all cause an adverse eect on the
reliability and accuracy of your scale. Handle with care. Gently apply all items to be weighed onto tray
top. Although this scale is designed to be quite durable, try to avoid rough treatment as this may permanently damage the internal sensor. Avoid shaking, dropping or otherwise shocking the scale. This is a
precision instrument and must be handled with extreme care.

OPERATION
1. Place scale on a horizontal at surface, press [ON/ZERO]
key to turn on the scale.
2. Wait until "0.0" is displayed
3. Put the object(s) on the weighing platform
4. Using the [g/lb] key, you can change the weighing units.
TARE/ZERO
T
are can be used for eliminating the weight value of an
empty container. Place an empty container on the scale,
press [ ON/ZERO ]. Then place the items to be weighed in the
container. NOTE: When all weight is removed from the
weighing tray, the tared value of a container will be
displayed as a negative number. Press [ON/ZERO] again to
return the scale to zero.
SPECIFICATIONS
Capacity 5000g
Readability 1g
Modes g/lb:oz
Tare Range Full capacity
Auto O 60 seconds
Op. Temp 15 to 30 degrees C
Display LCD 5 digits
Power 4 x AAA
Scale Dim. 207 x 175 x 20 mm
Tray 175 mm x 175 mm
DISPLAY ERROR MESSAGES
Change the batteries.
CLOCK/TIMER SETTING
1. General Settings
Please make sure that the scale is in clock mode. To toggle
through the modes (Clock, Alarm, Date) press [MODE].
Press [SET] when the scale is in clock mode to enter the
menu. Press [SET] again to toggle the settings till you
reach the desired mode. Press [MODE] to adjust the
selected digit. Press [SET] to conrm..
2. Setting the alarm & buzzer
Please make sure that the scale is in the clock mode. Press
[SET] to display the alarm time. Press [MODE] to toggle ON
and OFF the alarm and buzzer which are indicated by the
symbols ( ) and ( ) .
[O-LD]
[UnST]
You are overloading the
scale. Remove the
excessive load immediately.
Use the scale in a more
stable position.