ProMinent Sigma 3 S3Ba, Sigma 3 S3Ca Operating Instructions Manual

Page 1
Part No. 987517 ProMinent Dosiertechnik GmbH · 69123 Heidelberg · Germany BA SI XXX XX/XX GB
ProMinent
®
Please completely read through these operating instructions first! · Do not discard!
The warranty shall be invalidated by damage caused by operating errors!
Two sets of operating instructions are necessary to ensure the ProMinent
®
are operated safely and reliably for their intended purpose:
This product specific Sigma/ 3 operating instructions manual and the General operating instructions
ProMinent
®
motor-driven metering pumps and hydraulic accessories are only valid if read together!
Operating Instructions
ProMinent® Sigma/ 3 S3Ba (Basic Type) S3Ca (Control Type)
S3Ba S3Ca
Please enter the identity code of the device here.
S3Ca
___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___
S3Ca
___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___
Version 10.03
Page 2
Control elements: overview
1 Operating light (green) 2Warning light (yellow) 3 Error warning light (red) 4 Stroke length adjuster 5 LCD display 6 UP key 7 DOWN key 8P key
9 STOP/START key 10 i key 11 Relay output (optional) 12 Metering monitor socket 13 Float switch socket 14 External control socket 15 Diaphragm rupture indicator socket 16 Mains switch
Key functions
In continuous display mode In settings mode (operating) (settings)
STOP/START key
STOP
START
Press briefly Stop pump, Stop pump,
start pump start pump
P key
P
Press briefly Start batch (in “batch” operating mode only), Confirm entry- jump to next menu
Cancel error option or continuous display
Press for 2 s Change to settings mode --­Press for 3 s --- Jump to continuous display Press for 10 s Software version displayed --­Press for 15 s Load factory settings (calibration) ---
i key
i
Press x1 Toggle between continuous displays Toggle between “change individual digits”
and change a figure"
Press x2 --- For “change individual digits”:
jumps to first digit
Arrow keys UP and DOWN
Press separately Change directly alterable values Select other settings, (until “Set” appears) change individual digit or figure
Press simultaneously Prime (in “stroke rate” permanent display) ---
Control elements and key functions
1
2
3
16
4
9
10
8
5
6 7
15 14 13 12 11
Page 3
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P P
P
P
i
STOP
STOP
START
START
edom
Batch
Contact
ManualAnalog
edom
Analog
edom
Manual
edom
Contact
edom
Batch
edoc
enon
1edoc
2edoc
0
9
9
0
9
0
9
0
tes
glana
Set
02o
mA
Set
Analog
024
mA
Set
Analog
evruc
Set
Analog
11i
mA
Set
Analog
01i
mA
Set
Analog
12f
Freq.
Set
Analog
02f
Freq.
Set
Analog
11f
Freq.
Set
Analog
01f
Freq.
Set
Analog
91f
Freq.
Set
Analog
01f
Freq.
Set
Analog
91f
Freq.
Set
Analog
01f
Freq.
Set
Analog
92f
Freq.
Set
Analog
92f
Freq.
Set
Analog
02f
Freq.
Set
Analog
02f
Freq.
Set
Analog
91i
mA
Set
Analog
01i
mA
Set
Analog
91i
mA
Set
Analog
01i
mA
Set
Analog
22i
mA
Set
Analog
02i
mA
Set
Analog
92i
mA
Set
Analog
02i
mA
Set
Analog
92i
mA
Set
Analog
02i
mA
Set
Analog
nore
Set
Analog
ffore
Set
Analog
2 s
-----
Set
Analog
Set
Analog
Set
Analog
2
1
Operating-/Settings Diagram
Continuous
display
Start/stop pump
Change directly alterable values
= Lock (CODE 1)
= Lock (CODE 2)
Prime
Start batch (in"batch" operating mode only)
Cancel error
Check adjustable values
2
1
page 47
page 40
page 46
page 40
next page
First select the operating mode here and then enter the settings in the SET menu! Exceptions: Timer and PROFIBUS®.
Page 4
P
P
P
P
P
P
P
P
P
P
P
i
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
hctab
Set
wolf
Set
xua
Set
bilac
Set
raelc
L
N
9
*
Set
Mem
Batch
0
*
Set
Mem
Batch
9
*
Set
Mem
Batch
0
*
Set
Mem
Batch
9
*
Set
Mem
Batch
0
*
Set
Mem
Batch
9
*
Set
Mem
Batch
0
*
Set
Mem
Batch
6
*
Set
Mem
Batch
0
*
Set
Mem
Batch
ffo
Set
Mem
Batch
no
Set
Mem
Batch
no
Set
Flow
ffo
Set
Flow
1
Set
Flow
0
Set
Flow
9
Set
Flow
0
Set
Flow
9
Set
Flow
0
Set
Flow
9
Freq.
Set
Aux
0
Freq.
Set
Aux
9
Freq.
Set
Aux
0
Freq.
Set
Aux
1
Freq.
Set
Aux
0
Freq.
Set
Aux
no
Set
Calib
ffo
Set
Calib
trats
Set
Calib
0
Set
Calib
N
6
LSet
Calib
0
LSet
Calib
9
LSet
Calib
0
LSet
Calib
9
LSet
Calib
0
LSet
Calib
9
LSet
Calib
0
LSet
Calib
9
LSet
Calib
0
LSet
Calib
10000
Set
Mem
Batch
L
02451
Set
Mem
Batch
L
tinu
LSet
tinu
gal
Set
Set
Calib
N
002
P
P
P
P
P
tctnc
Set
no
Set
Mem
Contact
ffo
Set
Mem
Contact
9
Set
Mem
Contact
0
Set
Mem
Contact
9
Set
Mem
Contact
0
Set
Mem
Contact
9
Set
Mem
Contact
0
Set
Mem
Contact
9
Set
Mem
Contact
0
Set
Mem
Contact
P
P
SUB
Set
P
P
P
9
Set
0
Set
9
Set
Calib
0
Set
Calib
Set
Set
sRDDA
Set
0
9
P
page 42
page 44
page 45
page 46
page 46
page 46
page 29
previous page
Page 5
i
i
i
i
i
i
i
i
i
i
i
i
i
i
i
i
i
i
i
i
i
i
i
i
i
i
i
#
N
*
Mem
Contact
Stop
Operating mode "
Analog" 0-20 mA
Stroke rate
Feed rate
To tal stroke number
To tal litres
(feed quantity)
"External" display
Signal current
Strokes remaining
Batch size/
Litres remaining
Factor
"Mem" appears only when "memory" function activated
Stroke length
Operating mode "
Manual"
Continuous display
Operating mode "
Contact" with
memory and tansfer factor 5
Operating mode "
Batch" with
memory and tansfer factor 5
$ # !
N
Analog
Stop
&$ !
L
Analog
Stop
JN A
Analog
Stop
mA
Analog
Stop
#$
%
Analog
Stop
#$
%
Manual
Stop
# $
%
Contact
Stop
#$
%
Batch
Stop
&
Freq.
Manual
Stop
&
Freq.
Contact
Stop
$ # !
N
Stop
Contact
&
Freq.
Batch
Stop
$ # !
N
Stop
Batch
# %
/hL
Manual
Stop
$ # !
N
Stop
Manual
&$ !
L
Stop
Contact
&$ !
L
Stop
Batch
&$ !
L
Stop
Manual
JN A
Stop
Contact
Mem
J
N A
Stop
Batch
Mem
#
N
*
Mem
Batch
Stop
L
*
Mem
Batch
Stop
*
Mem
Batch
Stop
#
*
Mem
Contact
Stop
#
&
Freq.
Analog
Stop
# %
/hL
Analog
Stop
Continuous
display
= UP and/or DOWN arrow keys, directly alterable values
Operating mode ”Contact” with
memory and transfer factor 5
Operating mode ”Batch” with
memory and transfer factor 5
Page 6
Page 6
ProMinent
®
Dulcodes UV-Desinfektionsanlage
Imprint
Operating Instructions for ProMinent
®
Sigma/ 3 S3Ba/S3Ca
© ProMinent Dosiertechnik GmbH, 2000
ProMinent Dosiertechnik GmbH Im Schuhmachergewann 5-11 69123 Heidelberg P.O. Box 101760 69007 Heidelberg · Germany info@prominent.de www.prominent.de
Subject to technical modifications.
Imprint
Page 7
Dulcodes UV-Desinfektionsanlage
Page 7
ProMinent
®
Page
Device Identification/Identity Code 9
1 Notes on safety of ProMinent® metering pumps 11
1.1 General notes 11
1.2 Notes on installation, start-up and operation 11
1.3 Notes on maintenance and repair 12
2Product description S3Ba/S3Ca 13
2.1 Identification of pump type 13
2.2 Design/Functional description 13
2.2.1 Functional description, drive 13
2.2.2 Stroke movement 14
2.2.3 Metering capacity diagram 15
2.2.4 Functional description, delivery unit 17
2.2.5 Integrated overflow valve with bleeder function 18
2.2.6 Diaphragm rupture sensor 20
3Technical data 23
3.1 Technical data Sigma/ 3 basic type S3Ba23 23
3.1.1 Capacity data 23
3.1.2 Dimensions S3Ba 24
3.1.3 Dimensions S3Ca 25
3.1.4 Dimensions S3Ba with servo motor 25
3.1.5 Motor data 26
3.1.6 Stroke actuator drive mechanism 26
3.1.7 Stroke adjuster drive mechanism 26
3.1.8 Electrical data, stroke sensor “S3Ba” 26
3.1.9 Electrical data, pacing relay “S3Ba” 27
3.1.10 Sound intensity level 27
4 Start-up/Maintenance 28
4.1 Start-up 28
4.2 Maintenance 28
4.3 Replacement of wearing parts 28
5 Features of the S3Ca metering pumps 30
5.1 Function description, motors 30
5.2 Function description, controller 30
5.3 Sockets, symbols and wiring diagram 32
5.4 Retrofitting relays 38
Table of contents
Page 8
Page 8
ProMinent
®
Dulcodes UV-Desinfektionsanlage
Table of contents
6 Control elements 39
7 Settings 40
7.1. Check adjustable values 41
7.2 Change to settings mode 41
7.3 Select operating mode (MODE menu) 42
7.4 Settings for operating mode (SET menu) 42
7.4.1 Settings for “manual” operating mode 42
7.4.2 Settings for “analogue” operating mode (ANALG menu) 42
7.4.3 Settings for “contact” operating mode (CONTCT menu) 44
7.4.4 Settings for “batch” operating mode (BATCH menu) 46
7.5 Settings for programmable functions (SET menu) 46
7.5.1 Settings for “calibration” function (CALIB menu) 47
7.5.2 Settings for “auxiliary frequency” function (AUX menu) 47
7.5.3 Settings for the “flow” function (FLOW menu) 48
7.6 Setting code (CODE menu) 48
7.7 Cancel total stroke number or total litres (CLEAR window) 48
8 Operating 49
8.1 Manual operation 49
8.2 Remote control 50
9Troubleshooting 50
10 Decommissioning and disposal 52
11 Spare parts and accessories 53
Annex 54
Motor data sheet 54
EC Declaration of Conformity 55
Exploded diagrams of liquid ends 56
Wiring diagram, stroke actuator 63
Wiring diagram, stroke adjuster 63
Page 9
Dulcodes UV-Desinfektionsanlage
Page 9
ProMinent
®
Identity code ordering system
Please enter the identity code on the device label into the grey box below.
Dulcodes UV-Desinfektionsanlage
Identity code ordering system
ProMinent
®
S3Ba Sigma Basic Type (S3Ba)
H Main power end, diaphragm
Pump type: (Figures 1 + 2 = back pressure [bar], figures 3 - 5 = feed rate [l/h]):
120145* 12 bar; 145 l/h 120190* 12 bar; 190 l/h 120270* 12 bar; 270 l/h 120330* 12 bar; 330 l/h
070410 7 bar; 410 l/h 070580 7 bar; 580 l/h 040830 4 bar; 830 l/h 041030 4 bar; 1030 l/h *for PVDF max. 10 bar
Liquid end material:
PV PVDF SS Stainless steel
Seal material:
T PTFE seal
Positive displacement element:
0 Standard diaphram, PTFE version 1 With membrane rupture signalling (retrofittable)
Liquid end version:
0 No valve springs 1 With 2 valve springs, Hastelloy C, 0.1 bar 4 With bypass valve, Viton® seal, no valve springs 5 With bypass valve, Viton® seal and valve springs
Hydraulic connector:
0 Standard threaded connector (as technical data) 1 Union nut and PVC pipe connector insert 2 Union nut and PP pipe connector insert 3 Union nut and PVDF pipe connector insert 4 Union nut and stainless steel pipe connector insert 7 Union nut and PVDF tubing nozzle 8 Union nut and stainless steel tubing nozzle
Version:
0 With ProMinent® logo (standard) 1 Without ProMinent® logo
Power supply:
S3 ph, 230 V/400 V, 0.37 kW M1 ph, 230 V, 0.55 kW N1 ph, 115 V, 0.55 kW
L3 ph, 230 V/400 V, 0.37 kW, 50 Hz, (EExe, EExde) P3 ph, 230 V/400 V, 0.37 kW, 60 Hz, (EExe, EExde) RVariable speed stroke control motor, 3 ph, 230 V/400 V, 0.55 kW
Z Speed control, 1 ph, 230 V/400 V, 0.55 kW
1 No motor, with B 14 flange, size 71 (DIN)
2 No motor, with C 56 flange, (NEMA)
3 No motor, B 5 flange, size 71 (DIN)
Enclosure rating:
0 IP 55 1 Exe motor version (EExe II T3) 2 Exde motor version (EExde IIC T4)
Stroke sensor:
0 No stroke sensor (standard) 2 Pacing relay (read relay) 3
Stroke sensor (Namur) for potentially hazardons area.
Stroke length adjustment:
0 Manual 1 With stroke positioning motor, 230 V/50/60 Hz 2 With stroke positioning motor, 115 V/50/60 Hz 3 With stroke control motor
0...20 mA 230 V/50/60 Hz
4 With stroke control motor
4...20 mA 230 V/50/60 Hz
5 With stroke control motor
0...20 mA 115 V/50/60 Hz
6 With stroke control motor
4...20 mA 115 V/50/60 Hz
S3Ba _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Viton® is a registered trademark of DuPont Dow Elastomers.
Page 10
Page 10
ProMinent
®
Dulcodes UV-Desinfektionsanlage
Identity code ordering system
Identity code ordering system
Please enter the identity code on the device label into the grey box below.
S3Ca Sigma Control Type (S3Ca)
H Main drive, diaphragm
Pump type: (figures 1+2 = back pressure [bar], figures 3-5 = feed rate [l/h]):
120145* 12 bar; 174 l/h 120190* 12 bar; 228 l/h Note: 120270* 12 bar; 324 l/h 60 Hz performance data apply 070410 7 bar; 492 l/h for S3Ca pump types 070580 7 bar; 696 l/h (due to internal 60 Hz operation). 040830 4 bar; 1000 l/h * for PVDF max. 10 bar
Liquid end material:
PVT PVDF SST Stainless steel
Positive displacement element:
0 Standard diaphram, PTFE version 1 Double diaphragm with rupture indicator incorporating Pump stopping function 2 Double diaphragm with rupture indicator incorporating Pump alarm function
Liquid end version:
0 No valve springs 1With 2 valve springs, Hastelloy C 4: 0.1 bar (standar d for DN 32) 4With bypass valve, Viton® seal, no valve springs 5With bypass valve, Viton® seal and valve springs (standard for DN 32)
Hydraulic connector:
0 Standard thr eaded connector (as technical data) 1 Union nut and PVC insert 2 Union nut and PP insert 3 Union nut and PVDF insert 4 Union nut and stainless steel insert 7 Union nut and PVDF hose nozzel 8 Union nut and stainless steel hose nozzel
Version:
0 With ProMinent® logo (standard) 1 Without ProMinent® logo
Power supply:
A1 ph 200-230 V ±10 %, 50/60 Hz B1 ph 100-115 V ±10 %, 50/60 Hz
W1 ph 115-230 V ±10 %, 50/60 Hz
Lead and plug:
A2 m Europe B2 m Switzerland C2 m Australia D2 m USA
Relay:
0 No relay 1 Fault indicating relay N/C 3 Fault indicating relay N/O 4 As 1 + pacing relay 5 As 3 + pacing relay F power relay N/C
G power relay N/O
Control variants:
0 Manual + external with pulse control 1 Manual + external with pulse control + analogue 4 as 0 + process-timer 5 as 1 + process-timer
P PROFIBUS
®
Access code:
0 No access code 1 With access code
Metering monitor:
0 Input with pulse evaluation 1 Input with continuous contact evaluation
Stroke length adjustment:
0 Manual C Manual + calibration
S3Ca _ _ _ ___________
Viton® is a registered trademark of DuPont Dow Elastomers.
Page 11
Dulcodes UV-Desinfektionsanlage
Page 11
ProMinent
®
Notes on safety of ProMinent® metering pumps
1 Notes on safety of ProMinent® metering pumps
Notes on safety and important operating notes are divided into classes accompanied with pictograms. Please familiarize yourself with the following definitions and pictograms.
DANGER
Danger to life or risk of serious injury!
WARNING
Danger of injury or serious damage to the device!
IMPORTANT
These situations require complete attention!
NOTE
Information which must be followed!
1.1 General notes
WARNING
• The equipment/devices may only be used for their intended purpose.
•ProMinent
®
metering pumps must not be assembled with parts which are not tested and recommended by ProMinent otherwise this can lead to injury to persons and damage to property for which no liability will be accepted!
• Pumps must be accessible at all times to facilitate operation and maintenance. Access points must not be obstructed or blocked!
• Before carrying out any maintenance and repair work always drain off and flush out the liquid end first if hazardous or unknown metered media are used!
• When metering hazardous or unknown liquids, always wear safety clothing (safety goggles, gloves, ...) when working on the liquid end!
•You must observe the guidelines in this operating instructions manual and the ”General operating instructions manual for ProMinent
®
motor-driven metering pumps
and hydraulic accessoires” on assembly, installation and maintenance!
1.2 Notes on installation, start-up and operation
WARNING
• The metering pump can contain water residue in the liquid end as the result of testing at the factory!
If handling media which must not come in contact with water, all traces of water must be removed from the liquid end before start-up! For this purpose, turn the pump through 180˚ and drain off the liquid end then flush with a suitable medium from above via the intake connection!
• Do not connect mains voltage to the control cable!
• When operating the metering pump against a closed shut-off element on the pressure side or in the event of pressure peaks during the metering stroke, the system pressure can reach a multiple of the maximum permissible operating pressure that can conse­quently cause the pressure line to burst!
•To avoid this situation, an overflow is recommended for the purpose of limiting the maximum permissible operating pressure of the pump or system.
• Do not connect a metal bypass line to the overflow valve on the PVT delivery unit! This could cause cracks in the delivery unit!
Page 12
Page 12
ProMinent
®
Dulcodes UV-Desinfektionsanlage
IMPORTANT
• Set stroke length only with pump in operation!
• Pull the red plug for venting the gear unit during initial operation of the Sigma/ 3 metering pump (refer to Fig. 2, item 10)!
NOTE
• The pump must be secured in such a way that no vibrations can occur! The valves of the liquid end must always be positioned vertically in order to ensure trouble-free operation!
• The intake and delivery lines must always be arranged such as to ensure connection at the liquid end free of mechanical stress!
The lines must be secured such that no vibrations can occur!
• Only use the clamping rings and hose sockets intended for the relevant hose diameter as well as original hoses with the specified hose dimensions and wall thickness otherwise the stability and durability of the connection will not be guaranteed!
Avoid reducing hose sizes!
Observe the permissible pressure of the hoses!
•A vent with return to the supply tank is advisable when metering extremely aggressive or hazardous media!
In addition, a shut-off valve should be provided on the delivery or intake side!
1.3 Notes on maintenance and repair
WARNING
• Only specially trained and authorized persons are permitted to carry out maintenance on metering pumps and their periphery!
• If hazardous or unknown metering media are used, always flush out the liquid end first before carrying out any maintenance and repair work!
• When metering hazardous or unknown liquids, always wear safety clothing (safety goggles, gloves, ...) when working on the liquid end!
• Always depressurize the delivery line first before carrying out any work on the pump! Always discharge and flush liquid end! Observe safety data sheets for metered liquid!
DANGER
• Disconnect power plug or power supply line before opening the plug! Isolate relay option if applicable! Check to ensure power is disconnected! Secure pump while carrying out repairs to ensure it cannot be switched on unintentionally!
• Pumps for metering radioactive media must not be shipped through standard channels!
NOTE
The metering pump must be in a cleaned condition with the liquid end flushed if returned for repair!
Notes on safety of ProMinent® metering pumps
Page 13
Dulcodes UV-Desinfektionsanlage
Page 13
ProMinent
®
2Product description S3Ba/S3Ca
WARNING
Use for intended purpose
• The pump is designed as a liquid medium metering pump; it serves the purpose of metering liquid medium within the specified line system!
• Operate the pump only within the conditions described in the technical data!
• General restrictions with regard to viscosity limits, chemical resistance and density must be observed (refer to ProMinent chemical resistance list (catalogue or homepage))!
• All other applications or conversion are prohibited!
• The pump is not designed to meter gaseous media as well as solids.
• The pump is not suitable for metering combustible liquids!
• Only specifically trained and authorized personnel are permitted to operate the pump!
2.1 Identification of pump type
The identity code and serial number are given in addition to the standard technical specifications. These two numbers must always be quoted when making any enquiries as they enable distinct identification of the type of metering pump.
2.2 Design/Functional description
2.2.1 Functional description, drive
The ProMinent® Sigma/ 3 diaphragm-type metering pump is an oscillatory displacement pump with the stroke length adjustable in steps of 0.5%. It is driven by electric motor (1). The rotary drive of the electric motor is stepped down by worm gear and transmitted via the eccentric roller (3) to the push rod (4) connected to fork (8) and converted into oscillatory movement. Return spring (5) presses the fork with push rod positively against the eccentric roller thus producing the return stroke. The stroke is adjusted by means of stroke adjustment knob (6) and spindle (7) by limiting the return stroke. Stroke movement is transmitted directly to the displacement diaphragm. Interacting with the valves, this diaphragm produces the overpressure and vacuum in the liquid end necessary for delivery. Flow is pulsating.
In the basic type, the electric motor is normally a 3-ph extended-range AC motor (refer to Section 3 for other options).
Product description S3Ba/S3Ca
Fig. 1
Page 14
Page 14
ProMinent
®
Dulcodes UV-Desinfektionsanlage
0 180 360
1
10
6
7
3
8
5
4
2.2.2 Stroke movement
Set stroke length dependent on the required delivery capacity.
Product description S3Ba/S3Ca
Fig. 2
61_01-101_00_11-01
20 0
0 50
25 75
5
75%
0
5
0
25
10
30%
Fig. 4
S3Ba/S3Ca-007-GB
75 %
30 %
Fig. 3
S3Ba/S3Ca-006-GB
+ Delivery stroke
b) At reduced stroke length
– Intake stroke
a) Stroke progression
at max. stroke rate and stroke length
Stroke speed
Angle reduced stroke length
Page 15
Dulcodes UV-Desinfektionsanlage
Page 15
ProMinent
®
Product description S3Ba/S3Ca
Q (l/h)
Pressure in (bar)
S3Ba/S3Ca
HM12330
S3Ba/S3Ca
HM12270
S3Ba/S3Ca
HM12190
Q (l/h)
Stroke length in (%)
0
50
100
150
200
250
300
350
400
1211109876543210
S3Ba/S3Ca
HM12145
0
50
100
150
200
250
300
350
100908070605040302010
S3Ba/S3Ca
HM12330
S3Ba/S3Ca
HM12270
S3Ba/S3Ca
HM12190
S3Ba/S3Ca
HM12145
Fig. 6
HM_12 Hub
Fig. 5
HM12_Druck
NOTE
A large stroke length and low metering frequency should be selected for very viscous media! A shorter stroke length and high frequency should be selected to achieve good mixing properties!
2.2.3 Metering capacity diagram
Page 16
Page 16
ProMinent
®
Dulcodes UV-Desinfektionsanlage
Product description S3Ba/S3Ca
Fig. 7
HM07_Druck
Pressure in (bar)
Q (l/h)
Fig. 8
HM07_Hub
Stroke length in (%)
S3Ba/S3Ca
HM070410
S3Ba/S3Ca
HM040830
S3Ba/S3Ca
HM070580
S3Ba/S3Ca
HM041030
0
200
400
600
800
1000
1200
1009080706050403020
Q (l/h)
S3Ba/S3Ca
HM070410
S3Ba/S3Ca
HM040830
S3Ba/S3Ca
HM070580
S3Ba/S3Ca
HM041030
0
200
400
600
800
1000
1200
76543210,50
Page 17
Dulcodes UV-Desinfektionsanlage
Page 17
ProMinent
®
13
5
2
1
3
4
13
Product description S3Ba/S3Ca
Fig. 9
3154-4
Fig. 10
61_05-104_00_72-03
2.2.4 Functional description, delivery unit
The heart of the delivery unit is the DEVELOPAN® metering diaphragm (2). It hermetically seals the delivery chamber of liquid end (4) and produces a displacement in the liquid end. The end disc (5) made of chemically resistant plastic together with safety diaphragm (13) separates the drive housing from the delivery unit and protects the drive from corrosion in the event of the diaphragm failing. Delivery is based on the interaction between intake valve (1) and head valve (3) of the same design together with the diaphragm movement. The valve balls can be supported with springs for metering viscous media.
The connection dimensions of valves and liquid ends of the same size but with different materials are identical. These parts can be interchanged as required.
Materials and dimensions are specified in Section 3, Technical data.
3
2
5
1
4
13
2
5
3
1
4
Page 18
Page 18
ProMinent
®
Dulcodes UV-Desinfektionsanlage
110
127
134
102
133
137
132
138
139*
131
202
203
126
125
136
128
130
111
112
100
114
115
118
200
201
117
101
113
116
Product description S3Ba/S3Ca
2.2.5 Integrated overflow valve with bleeder function
Task:
The task of the overflow valve is to protect the motor and gear unit against impermissible overpressure caused by the metering pump.
This function is produced by a spring-loaded ball.
A pressure relief mechanism for the bleeder function is provided.
Design and functional description
(refer to Fig. No. 11 and 12)
Initially, the overflow valve illustrated under item 102 operates as a simple directly control safety valve. As soon as the pressure set with spring item 132 is exceeded, the effective pressure raises ball item 130. The liquid then flows off into the tank via hose connection item 128.
Delivery unit overflow valve Sigma/ 3, 10 bar PVT Identity code type: 120145, 120190, 120270, 120330
Delivery unit overflow valve Sigma/ 3, 4 bar PVT Identity code type: 040830, 041030
Delivery unit overflow valve Sigma/ 3, 7 bar PVT Identity code type: 070410, 070580
Fig. 11
3160-4
Page 19
Dulcodes UV-Desinfektionsanlage
Page 19
ProMinent
®
111
134
102
133
132
138
139*
131
202
203
126
125
127
136
128
130
112
100
110
114
115
118
200
201
117
101
113
116
137
141
140
129
Product description S3Ba/S3Ca
Delivery unit overflow valve Sigma/ 3, 12 bar SST Identity code type: 120145, 120190, 120270, 120330
Delivery unit overflow valve Sigma/ 3, 4 bar SST Identity code type: 040830, 041030
Delivery unit overflow valve Sigma/ 3, 7 bar SST Identity code type: 070410, 070580
Fig. 12
3161-4
IMPORTANT
• Knob item 139 must be turned in clockwise direction as far as it will go ”close“.
• The bypass line must always be closed and must be routed back into the supply tank. Connection via hose connection item 128.
• Minimal overflow can occur in the bypass line when the valve operates close to the overpressure function.
The bleeder function is achieved by turning knob item 139 in counterclockwise direction as far as it will go ”open“: Priming aid for starting up pump against pressure. The force of spring item 132 relieves ball item 130 which is controlled by the lower spring force of bleeder spring item 133.
IMPORTANT
Once the pump has primed, turn knob item 139 in clockwise direction as far as it will go ”close“! The pump can now be placed into operation.
Page 20
Page 20
ProMinent
®
Dulcodes UV-Desinfektionsanlage
Product description S3Ba/S3Ca
Technical data
Corresponding to the type of pump, overflow valves are available for pressure stages p
nom
4, 7,
10 and 12 bar with (1.05 ... 1.15) xp
nom
opening pressure.
Material in contact with metered medium
Liqiud end: Overflow valve: Seals in overflow valve: Balls (DN25): Plates (DN 32): Springs:
PVDF PVDF Viton
®
O-rings*, PTFE Glass Hastelloy C Hastelloy C
Stainless steel 1.4571 Stainless steel 1.4571 Viton® O-rings*, PTFE Stainless steel 1.4571 Hastelloy C Hastelloy C
*Viton® is a registered trademark of DuPont Dow Elastomers.
Use for intended purpose/Use not for intended purpose
Use for intended purpose
To protect the motor and gear unit against impermissible overpressure caused by the metering pump.
If the pump is the only pressure generator in the system, the overflow valve will also protect the system automatically.
IMPORTANT
• The ceramic ball and ball seat of the overflow valve are wearing parts. Slight leakage can occur at the safety valve after a prolonged period of operation. The ball and ball seat should be replaced if leaks occur.
• The bypass line must always be connected and must be routed back into the supply tank.
Use not for intended purpose
To protect the system from impermissible overpressure which has other causes than the pressure generated by the metering pump.
The pump must not be operated without the bypass line connected.
The bypass line must not be connected in the intake line (the bleeder function will no longer be guaranteed). The bypass line must be routed back into the supply tank.
DANGER
When carrying out maintenance work on the overcurrent valve, pay attention to the tensioning state of the pressure spring item132! Wear safety goggles!
2.2.6 Diaphragm rupture sensor
Function:
Monitors the seals in the working diaphragm. This liquid end can continue to function for a short period in emergency mode, i.e. full operating pressure, no leakage, even after diaphragm rupture.
Design and function description (see Fig. 13)
Liquid ends with diaphragm rupture sensors comprise a standard liquid end (item 100) a working diaphragm (item 200) and an auxiliary diaphragm (item 148) The auxiliary diaphragm is positioned between the back plate (item 201) and the interim plate (item 147) and forms a sealed compartment together with the working membrane (item 200).
The leak tightness of the working diaphragm, Item 200, is monitored with a diaphragm failure detector, Item 104, that triggers a contact signal in the event of diaphragm failure so that the pump is stopped in the S3Ca and the diaphragm failure is indicated on a LCD.
Page 21
Dulcodes UV-Desinfektionsanlage
Page 21
ProMinent
®
103
111
112
118
203
204
200
100
116
110
101
117
113
114
115
147
148
149
158
160
104
150
201
159
156
157
155
161
162
163
Product description S3Ba/S3Ca
The liquid end can continue to operate in emergency mode, i.e. full operating pressure, no leakage, even after diaphragm rupture, until the diaphragm has been replaced. We offer two versions of the S3Ca with diaphragm rupture sensor:
After a working diaphragm rupture, the pump stops and an error message/diaphragm sensor signal is given.
After a working diaphragm rupture, the pump will continue to run. An error message/ electrical signal is given.
A function plug is supplied which allows the pump to continue operating after a fault has occurred (diaphragm rupture, failure of the diaphragm rupture sensor).
IMPORTANT
• In the case of the S3Ba, the customer should install a diaphragm rupture signal monitor and/or ensure that the pump will stop after a diaphragm rupture.
• In the event of diaphragm failure, a contact signal is triggered as from 2 bar system backpressure.
• Exact pump delivery can no longer be guaranteed after failure of the working diaphragm.
• The auxiliary diaphragm, Item 148, is a wearing part and must be replaced after failure of the working diaphragm. The diaphragm rupture sensor lens should be replaced after every diaphragm rupture.
FM 130 Id. code type: 120145, 120190, 120270, 120330
FM 350 Id. code type: 040830, 041030, 070410, 070580
Fig. 13
3162-4
Page 22
Page 22
ProMinent
®
Dulcodes UV-Desinfektionsanlage
Material in contact with metered medium
Liquid end: Parts of diaphragm failure monitor in contact with medium
Lens, seals Intermediate disc Item 147, Item 148, 156, 159 intermediate bush Item 150
PVDF PTFE PVDF Stainless steel 1.4571 PTFE PVDF
Electrical data for the diaphragm breakage sensor
30 V DC/1 A or 125 V AC/0.6 A or 250 V AC/0.3 A
The diaphragm sensor is a N/C relay.
IMPORTANT
Before commencing operation, install the provided diaphragm breakage sensor together with the gasket (Item159) and make the electrical connections.
NOTE
• For safety reasons it is advisable to connect a safe low voltage (e.g. EN 60335-1 (SELV)).
• The cable priority is arbitrary.
Product description S3Ba/S3Ca
Page 23
Dulcodes UV-Desinfektionsanlage
Page 23
ProMinent
®
Technical data
3Technical data
3.1 Technical data Sigma/ 3
3.1.1 Capacity data
Technical data S3Ba at 50 Hz operation
Capacity at max. Intake Permissible Connection Shipping max. stroke head admission intake/ weight backpressure frequency pressure delivery
intake side side
Pump type bar l/h ml/ Strokes/ m water bar G-DN kg Sigma/ 3 stroke min. column
120145 PVT 10 145 31.5 72 5 2 1
1
/2"-DN 25 22
120145 SST 12 145 31.5 72 5 2 11/2"-DN 25 26
120190 PVT 10 190 31.5 103 5 2 1
1
/2"-DN 25 22
120190 SST 12 190 31.5 103 5 2 11/2"-DN 25 26
120270 PVT 10 270 31.5 144 5 2 11/2"-DN 25 22
120270 SST 12 270 31.5 144 5 2 1
1
/2"-DN 25 26
120330 PVT 10 330 31.5 180 5 2 11/2"-DN 25 22
120330 SST 12 330 31.5 180 5 2 11/2"-DN 25 26
070410 PVT 7 410 95.1 72 4 1 2"-DN 32 24
070410 SST 7 410 95.1 72 4 1 2"-DN 32 29
070580 PVT 7 580 95.1 103 4 1 2"-DN 32 24
070580 SST 7 580 95.1 103 4 1 2"-DN 32 29
040830 PVT 4 830 95.1 144 3 1 2"-DN 32 24
040830 SST 4 830 95.1 144 3 1 2"-DN 32 29
041030 PVT 4 1030 95.1 180 3 1 2"-DN 32 24
041030 SST 4 1030 95.1 180 3 1 2"-DN 32 29
Technical data S3Ba at 60 Hz and all S3Ca types
Capacity at max. Intake Permissible Connection Shipping max. stroke head admission intake/ weight backpressure frequency pressure delivery
intake side side
Pump type bar psi l/h/gph Strokes/ m water bar G-DN kg Sigma/ 3 min. column
120145 PVT 10 145 174/ 46 86 5 2 1
1
/2"-DN 25 22
120145 SST 12 174 174/ 46 86 5 2 11/2"-DN 25 26
120190 PVT 10 145 228/ 60.2 124 5 2 11/2"-DN 25 22
120190 SST 12 174 228/ 60.2 124 5 2 1
1
/2"-DN 25 26
120270 PVT 10 145 324/ 85.6 173 5 2 11/2"-DN 25 22
120270 SST 12 174 324/ 85.6 173 5 2 11/2"-DN 25 26
070410 PVT 7 100 492/ 130 86 4 1 2"-DN 32 24
070410 SST 7 100 492/ 130 86 4 1 2"-DN 32 29
070580 PVT 7 100 696/ 183.9 124 4 1 2"-DN 32 24
070580 SST 7 100 696/ 183.9 124 4 1 2"-DN 32 29
040830 PVT 4 58 1000/ 264 173 3 1 2"-DN 32 24
040830 SST 4 58 1000/ 264 173 3 1 2"-DN 32 29
All performance data applies to water at 20 °C. The suction lift applies when the suction line and liquid end are full and correctly installed.
Page 24
Page 24
ProMinent
®
Dulcodes UV-Desinfektionsanlage
Technical data
A
B
214
136
120
G
F
452.5
177
D/D1
C
225
E/E1
6.5
120
28
Connection
variations
PVDF
PP/PVC/PTFE
SS
Fig. 14
61_01-101_00_12-73
Materials in contact with metered media
Material Liqiud end: Intake/delivery Seal: Balls Plates connection: connection: FM 330: FM 1000:
PVT PVDF PVDF PTFE Glass
Hastelloy C
SST Stainless steel Stainless steel PTFE Stainless steel
Hastelloy C
1.4571 1.4571 1.4571
Temperature specifications
Permissible storage temperature: –10 to +50 °C Permissible ambient temperature: –10 to +40 °C
Temperature compatibility (medium temperature) of materials
Material: Long-term at max. Short-term, max. 15 min.
backpressure: at max. 2 bar
PVT 65 °C 100 °C
SST 90 °C 120 °C
The specified temperatures (see above) can be exceeded temporarily, e.g. for sterilisation or flushing with hot water.
Accuracy
Under constant conditions and in minimum stroke length of 30 % corresponding to following notes, the reproducibility of the metered quantity is better than ±2 %.
All specifications refer to metered quantities with water at 20 °C and correct installation of the metering pump.
3.1.2 Dimensions S3Ba (in mm)
Dimensions Sigma/ 3 (in mm)
Feed unit Connection A B C D D1* E E1* F Ø G
FM 330 PVT DN 25 292 230 G11/2"A 120 140 353 373 82 156
FM 330 SST DN 25 292 230 G1 1/2"A 121 141 343 363 89 156
FM 1000 PVT DN 32 325 297 G2"A 127 147 373 393 121 206
FM 1000 SST DN 32 322 291 G2"A 127 147 357 377 121 206
FM 330 for Sigma/ 3, 120145, 120190, 120270, 120330 FM 1000 for Sigma/ 3, 070410, 070580,040830, 041030
* Measurements with diaphragm rupture sensor.
Page 25
Dulcodes UV-Desinfektionsanlage
Page 25
ProMinent
®
452.5
B
A
50
C
G
F 257.6
E/El
D/Dl 120
28 6.5
177.5
177.5
+7
60.5
136
120
214
Technical data
3.1.3 Dimensions S3Ca (in mm)
Fig. 16
61_01-101_00_12-73
3.1.4 Dimensions S3Ba with stroke positioning motor (in mm)
Dimensions Sigma/ 3 with stroke positioning motor (in mm)
Motor flange Ø P Ø M Ø N Ø S Ø D T R
B14 160/200 200 165 130 11 19 6 41.5
56 C 167 149.3 114.3 11 15.87 6 56.5
B14 160 160 130 110 11.8 14 4 35
Fig. 15
61_01-101_00_15-73
Table of alternative dimensions, see 3.1.2
Page 26
Page 26
ProMinent
®
Dulcodes UV-Desinfektionsanlage
Technical data
3.1.5 Motor data
Electrical data Motors: Ident code letter
3 ph IP 55 230 V/400 V 50/60 Hz 0.37 kW S
1 ph AC 230 V 50/60 Hz 0.55 kW M
1 ph AC 115 V 60 Hz 0.55 kW N
3 ph EEXe o. EEXde 230 V/400 V 50 Hz 0.37 kW L
3 ph EEXe o. EEXde 230 V/400 V 60 Hz 0.37 kW P
3 ph IP 55 230 V/400 V 50/60 Hz 0.55 kW R
Version with external fan 1 ph 230 V: 50/60 Hz and PTC
For more details you can request the motor specification sheets. Custom motors and/or custom motor flanges are available on request.
Fuse data
IMPORTANT
• No fuse is provided for the 3pH AC motor. Fitting a motor circuit-breaker.
• When connecting the motor, make sure that it rotates in the correct direction (see Fig. 16 on the left side).
Protection against accidental contact and moisture (IP)
Motor: IP 55 DIN EN 60034-5 (in accordance with DIN VDE 0470 Part 1, corresponds to
EN 60529 and IEC 529).
External fan
External fan for speed controlled motor with external fan and temperature monitor: Note information in General operating instructions for ProMinent
®
metering pumps and
hydraulic accessories.
3.1.6 Stroke actuator drive mechanism
Cf. Appendix for terminal connection diagram.
3.1.7 Stroke adjuster drive mechanism
Cf. Appendix for terminal connection diagram.
3.1.8 Electrical data, stroke sensor “Sigma”
A) Reed contact (Identcode ID “Stroke sensor”: 2)
Pin 1 (white) = 4.5 V to 24 V, max. 10 mA Pin 2 (brown) = OUT, open collector, 24 V, 20 mA Pin 3 (green) = GND Pulse width (low) 4 ms (depending on gearbox and power frequency)
B) Namur sensor (Identcode characteristic “Stroke sensor”: 3)
5-25 V DC, Namur type and/or DIN 19234, zero volt design.
Rated voltage: 8 V DC (R
i
~ 1 kΩ)
Power consumption:
Active surface, uncovered > 3 mA Active surface, covered < 2 mA
Rated switching distance: 1.5 mm
The monitor/feeder must be capable of evaluating current changes in order to indicate diaphragm rupture!
Enclosure rating: EEx ia ll C T 6 and/or EEx ib C T 6 Can be used in explosive areas with suitable power supply unit.
Fig. 17
S3Ba/S3Ca-026-D
direction of rotation
Blue -
Brown +
230 V ± 10 % 50/60 Hz 11.7 W
115 V ± 10 % 60 Hz 11.7 W
230 V ± 10 % 50/60 Hz 6.5 W
115 V ± 10 % 60 Hz 6.5 W
Page 27
Dulcodes UV-Desinfektionsanlage
Page 27
ProMinent
®
Technical data
3.1.9 Electrical data, pacing relay “S3Ba”
Relay input
(power supply for the relay board)
Relay output
Input voltage Mains frequency Power consumption
200/230 V AC (180-254 V) 50/60 Hz 10 mA (230 V/50 Hz)
100/115 V AC (90-134 V) 50/60 Hz 15 mA (115 V/60 Hz)
24 V DC (20-23 V) 10 mA at 24 V DC
Voltage, max. 42 V DC
Current, max. 100 mA
Hook up duration 100 ms Standard adjustable
The contacts are zero volt.
3.1.10 Sound intensity level
The sound intensity level is < 70 dB (A) at maximum stroke, maximum stroking rate, maximum back pressure (water) in accordance with DIN EN 12639 (noise measurement in fluid pumps)
Page 28
Page 28
ProMinent
®
Dulcodes UV-Desinfektionsanlage
4 Start-up/Maintenance
IMPORTANT
Observe the safety notes provided in Section 1.
4.1 Start-up
All general guidelines in the accompanying General operating instructions ProMinent
®
motordriven metering pumps and hydraulic accessories apply.
4.2 Maintenance
IMPORTANT
After loosening the liquid end screws (e.g. to change the valves or diaphragm), the screws must be retightend corsswise to the specified tightening torque.
What requires maintenance?
Secure fit of liquid end screws.
Secure fit of metering lines (intake and delivery sides).
Secure fit of head valve and intake valve.
Leakage hole at end disc for moisture (indicates possible diaphragm failure).
Operate pump continuously for a short period of time in order to check whether it delivers
correctly.
Maintenance intervals
General recommendation for maintenance intervals - every 3 months.
Shorter intervals are recommended if operated under load conditions (e.g. continuous operation).
The gear oil should be changed after approx. 5000 duty hours.
Gear oil ISO viscosity class VG 460, e.g. Mobil Gear 634,
ProMinent Order No. 555325 (Amount of oil approx. 0.9 l).
The metering diaphragm is a wearing part whose service life is dependent on following parameters:
System backpressure.
Operating temperature.
Properties of medium to be metered.
The service life of the diaphragm is restricted in the case of abrasive media. In such cases, it is recommended to check the diaphragm more frequently and to install a diaphragm failure monitor.
4.3 Replacement of wearing parts
Replacing diaphragm (see exploded diagrams in appendix!)
IMPORTANT
Flush liquid end first in the case of hazardous media. For this purpose, force water or a suitable flushing agent through the intake connection of the liquid end with a wash bottle.
Set stroke length to zero with the pump running. Switch off pump.
Release the six screws holding the liquid end, detach liquid end together with screws.
Release diaphragm from the push rod by jolting in counterclockwise direction and unscrew.
Screw on new diaphragm until it is firmly seated on the push rod. Mount the dosing head with
screws such that the suction connection lies at the bottom (observe the flow through direction / arrow marks on the valves). Switch on pump. Set stroke length to 100% and turn in screws then tighten crosswise to 7.5 ± 0.5 Nm (FM 330) resp. 12 Nm ± 1 Nm (FM 1000). Check pump for leaks at max. pressure.
Start-up/Maintenance
Page 29
Dulcodes UV-Desinfektionsanlage
Page 29
ProMinent
®
Start-up/Maintenance
NOTE
The tightening torque of the liquid end screws should be rechecked after 24 hours of operation.
The tightening torques of the liquid end screws should be checked every 3 months for the PVT material version.
GUIDELINE ON VALVE INSTALLATION (DN 25 ball valve)
In the case of suction problems during installation, place the valves on a firm surface and tap the PTFE ball seat disk lightly with a brass rod and a hammer weighing about 300 g. Let the valves such in the wet state.
IMPORTANT
• If suction problems with the pump or leakage at the overcurrent valve are encountered, first clean the ball and the ball seat disc.
NOTE
• For media containing particles larger than 0.3 mm it is absolutely essential to install a filter in the suction line.
Fig. 19
S3Ba/S3Ca-019-GB
approx. 300 g
Brass rod 9 mm diam. x approx. 200 mm
Fig. 18
S3Ba/S3Ca-014-GB
Page 30
Page 30
ProMinent
®
Dulcodes UV-Desinfektionsanlage
Features of the S3Ca metering pumps
5 Features of the S3Ca metering pumps
5.1 Function description, motors
All pump versions are fitted with integrated motor overload circuit breaker. This responds as soon as the maximum admissible power consumption is reached and the motor stops running.
The electronic controller recognises when a motor is stopped due to a system overload and
indicates a fault on the display and at the pump.
The fault signal can be cancelled by pressing the P key, altering the level for a brief period at
the pause input (switch function) or by reconnecting the pump to the mains.
IMPORTANT
If the motor has been switched off via the electronic overload protection, check that the pump is not being continuously overloaded.
NOTE
• The motor is electrically installed on delivery.
• The performance data in section. 3.1.1 for the S3Ba are measured with a 3-phase motor. If the S3Ba is fitted with a single phase motor the speed may be up to 5 % less due to the different motor characteristic i.e. resulting in up to 5 % lower feed rate!
• The controller changes over to digital stroking mode at low stroke frequencies! This takes place at stroke frequencies below 1/3 of the maximum stroke frequency. This function is designed to ensure sufficient cooling of the motor and low stroke frequencies.
Type: 115 – 230 V ± 10 %, 50/60 Hz
at 115 V at 230 V
Nominal output 420 W 420 W
Nominal current 6.0 A 3.4 A
Peak current (in operation)* 20 A 13 A
Making peak current 12 A 24 A
Fuse, internal** 6.3 AT (1.5kA) 6.3 AT (1.5kA)
* internal switch function ** Only genuine fuses of ProMinent, item no. 732379, may be used!
5.2 Function description, controller
Operating modes Operating modes are selected using the MODE menu (depending upon identity code, some
operating modes may be absent).
“Analogue” operating mode: (Identity code, control variant: analogue) The stroke rate is controlled via an analogue electrical signal via the external control terminal. Signal processing is pre-selected at the controller.
“Manual” operating mode:
The stroke rate is controlled manually via the controller.
“Contact” operating mode:
This operating mode offers the opportunity to make fine adjustments with small increase/ decrease factors. Dosing can be activated by a pulse via the external control terminal or by a semiconductor element. With the pulse control option it is possible to pre-set a feed quantity (batch) or number of strokes (factor 0.01 to 99.99) via the control unit.
“Batch” operating function:
This operating mode offers the option of working with larger transfer factors (up to 65535). Metering can be triggered by pressing the P key or a pulse from the external control terminal via a contact or semiconductor element. A batching quantity or number of strokes can be pre­selected via the control unit.
“PROFIBUS
®
” mode: (Identity code, control variant: PROFIBUS®)
This operating mode provides the option of controlling the pump via the PROFIBUS® (see Supplementary instructions for ProMinent® gamma/ L and ProMinent® Sigma versions with PROFIBUS®”).
Page 31
Dulcodes UV-Desinfektionsanlage
Page 31
ProMinent
®
Features of the S3Ca metering pumps
Functions The following functions can be selected using the SET menu:
“Calibrate” function (Identcode, Stroke length adjustment: manual + calibration):
The S3Ca can be operated in all operating modes including in calibrating mode. The corresponding continuous displays can show the actual feed quantity or the feed rate. Calibration is maintained within the stroke frequency range 0-180 strokes/ min. Calibration is also maintained when a stroke frequency is altered up to ±10 scale points.
“Auxiliary frequency” function:
It is possible to set a stroke rate in the SET menu, which may be activated via the external control terminal. This auxiliary frequency overrides all other pre-set stroke rate frequencies.
“Flow” function:
Stops the S3Ca when the flow is insufficient. In the SET menu, the number of failed strokes is entered after which the pump will be turned off.
The following functions are available as standard:
“Float switch” function:
Information on the liquid level in the feed chemical container is transmitted to the S3Ca. This option requires the installation of a 2-stage float switch. This is connected to the float switch terminal.
“Pause” function:
The S3Ca can be stopped by remote control via the external control terminal. The pause function operates only via the external control terminal.
The following functions are activated by keystrokes:
“Stop” function:
The S3Ca can be stopped by pressing the STOP/START key without disconnecting from the mains power supply.
“Prime” function:
Priming (short term feed at maximum frequency) is activated by pressing both arrow keys at the same time (in permanent display Stroke rate).
Optional relay The S3Ca has two connection options (not with PROFIBUS
®
).
“Fault indicating relay or power relay” option:
In the event of fault signals, warning signals or float switch activation signals, connects an electrical circuit to trigger alarm sirens etc. The relay is retrofitted via an aperture in the power end.
“Fault indicating and pacing relay” option:
In addition to the fault-indicating relay the pacing relay make a contact with every stroke. The relay is retrofitted via an aperture in the power end.
Function and error
indicators The operating and error status is shown via the three LEDs and the error indicator on the
LCD (see also section 9):
LCD indicator If a fault occurs error will appear along with an additional fault warning.
LED indicator Operating indicator (green)
This indicator is lit as long as the S3Ca is operating correctly. It is cancelled briefly at every stroke.
Warning indicator (yellow)
This warning light appears if the S3Ca electronics detect a situation that could lead to a fault, e.g. liquid levels low 1st stage”.
Warning indicator (red)
This warning light appears if a fault occurs, e.g. liquid levels low 2nd stage”.
Page 32
Page 32
ProMinent
®
Dulcodes UV-Desinfektionsanlage
Hierarchy of operating modes, functions and fault statuses
The different operating modes, functions and fault statuses each have a differing effect on whether and how the S3Ca functions. These effects are given below:
1. Prime
2. Fault, stop, pause
3. Auxiliary frequency
4. Manual, analogue, contact, batch
i.e.
1. Priming is possible in the Stroke rate permanent display in any pump mode.
2. Fault, stop and pause stop all system parts up to prime”.
3.
The Auxiliary frequency stroke rate always takes priority over the stroke rate specified by an operating mode set as under 4.
5.3 Sockets, symbols and wiring diagram
(1) Socket for two-stage float switch with advance warning and de-activate function
(2) External socket for contact or analogue controller with zero volts deactivation via pause
function
(3) Metering monitor socket for connection of ProMinent metering monitor
(4) Mains switch (1-pin)
(5) Relay cable (fault indicating and/or pacing relay)
(6) Socket for diaphragm rupture sensor
(7) Mains lead with plug
*Must be plugged in unless cable attached.
Features of the S3Ca metering pumps
4
1
7
5
23
6
Fig. 20
Page 33
Dulcodes UV-Desinfektionsanlage
Page 33
ProMinent
®
Features of the S3Ca metering pumps
2
1
4
green/NC
white/NO
brown/C
pacing relay
fault indicating relay
yellow/NO
white/NO
green/NC
brown/C
1
4
3
2
2
3 1
4
Technical data, relay (control version)
Pump type S3Ca
Relay Fault-indicating relay Fault-indicating relay + pulse generator
Relay type Fault-indicating relay pulse generator Fault-indicating relay
Voltage, max: 250 V 50/60 Hz 24 V DC 24 V 50/60 Hz
Current, max. 2 A (ohmic) 100 mA 100 mA
Hook up duration 100 ms
Behaviour see Identcode see Identcode see Identcode
Service life > 200 000 cycles > 50 x 106 (10 V 10 mA) > 200 000 cycles
Relay type Power relay
Voltage, max: 250 V 50/60 Hz
Current, max. 16 A (ohmic)
Hook up duration
Behaviour see Identcode
Service life > 30 000 switching cycles
* in the case of nominal load
The contacts are zero volt.
N/C fault indicating relay - the relay closes immediately after the power is switched on and opens in the event of a fault.
N/O fault indicating relay, the relay closes in the event of a fault.
Use suitable interference suppression (e.g. RC glands) when connecting inductive loads.
Page 34
Page 34
ProMinent
®
Dulcodes UV-Desinfektionsanlage
Wiring diagram
View of cable connectors from front
Float switch cable
for
Universal signal cable (5-score)
for
Metering monitor cable
for
Diaphragm rupture cable
for
External/contact cable (2 core)
for
Contact open -> alarm
-> pump stops with controller type 0
Contact closed -> metering stroke
Blue and black open
-> alarm signal Brown and black open
-> alarm signal + pump stops
Pause function:
brown and black closed
-> pump metering
brown and black open
-> pump stopped
External/contact:
white and black closed
-> start contact for pump (note pause function: brown and black closed)
Analogue:
blue, black
-> analogue output 0/4-20 mA (note pause function: brown and black closed)
Auxiliary frequency:
grey and black closed
-> pump metering at pre-set stroking rate
Circuit examples page 37
Features of the S3Ca metering pumps
2 blue/alarm
1 black GND
3 brown/pause
1 brown / 5 V
2 white/cod
3 blue
4 black/ GND
1 brown / pause
2 white/cod
3 blue / analogue
4 black/ GND
5 grey/auxiliary
2 brown
4 white
2 blue/alarm
1 black/GND
Page 35
Dulcodes UV-Desinfektionsanlage
Page 35
ProMinent
®
Technical data, external contact
Semi-conductor switch elements (e.g. transistors in open-collector circuits) or contactors (relays) with a residual voltage of -0.7 V can be used as input switch elements.
Controller type 0 (see identity code)
Pin 1 = Pause input (activating function)
Voltage at open contacts: approx. 5 V Input resistance: 10 k Controller: – zero volts contact (approx. 0.5 mA)
– semi-conductor (residual voltage: < 0.7 V)
Pin 2 = Contact input
Voltage at open contacts: approx. 5 V Input resistance: 10 k Controller: – zero volts contact (approx. 0.5 mA)
– semi-conductor (residual voltage: < 0.7 V) Min. contact duration: 20 ms Max. pulse frequency: 25 pulses/s
Pin 3 = unused
Pin 4 = GND
Pin 5 = Auxiliary input
Voltage at open contacts: approx. 5 V Input resistance: 10 k Controller: – zero volts contact (approx. 0.5 mA)
– semi-conductor (residual voltage: < 0.7 V)
Controller type 1 (see identity code)
Pin 1 = Pause input (activating function)
Voltage at open contacts: approx. 5 V Input resistance: 10 k Controller: – zero volts contact (approx. 0.5 mA)
– semi-conductor (residual voltage: < 0.7 V)
Pin 2 = Contact input (not active during analogue operation)
Voltage at open contacts: approx. 5 V Input resistance: 10 k Controller: – zero volts contact (approx. 0.5 mA)
– semi-conductor (residual voltage: < 0.7 V) Min. contact duration: 20 ms Max. pulse frequency: 25 pulses/s
Pin 3 = Identical to input*
Input load: approx. 120
Pin 4 = GND
Pin 5 = Auxiliary input
Voltage at open contacts: approx. 5 V Input resistance: 10 k Controller: – zero volts contact (approx. 0.5 mA) – semi-conductor (residual voltage: < 0.7 V)
* The metering pump makes its first metering stroke at approx. 0.4 mA (4.4 mA) and starts continuous operation at approx. 19.2 mA.
Features of the S3Ca metering pumps
Page 36
Page 36
ProMinent
®
Dulcodes UV-Desinfektionsanlage
GND
External
activation
Diaphragm
rupture
sensor
Metering
monitor
Level
monitor
Fault
indicating
relay
warning
Mains
Circuit examples overleaf
Metering
monitor
Flow control
Diaphragm
rupture
sensor
3 white/NO (pacing)
Fault
indicating
and
pacing relay
VDE cable:
Empty signal,
2 brown/C (pacing)
1 white /NO
4 brown/C
1 yellow/NO (fault)
4 green/C (fault)
2 green/NC
3 brown/pause
2 blue/alarm
1 black/GND
1 brown/5 V
2 white/cod
4 black/GND
3 blue
2 blue/alarm
1 black/GND
VDE cable:
1 brown/pause
2 white/contact
4 black/GND
3 blue/analogue
5 grey/auxiliary
Block circuit diagram S3Ca
Features of the S3Ca metering pumps
Input
Pump, Inside
Output
Page 37
Dulcodes UV-Desinfektionsanlage
Page 37
ProMinent
®
Features of the S3Ca metering pumps
Circuit examples: universal signal cable
by customer Cable Pump, inside
Pause function
Permanent contact, e.g. from control room
Auxiliary frequency function
External analogue function
Permanent contact, e.g. from control room
Analogue signal, e.g. from magnetic inductive flow meter
0/4-20 mA
External activation
External activation
3 blue/analogue
2 white/contact
1 brown/pause
4 black/GND
5 grey/auxiliary
3 blue/analogue
2 white/contact
1 brown/pause
4 black/GND
5 grey/auxiliary
3 blue/analogue
2 white/contact
1 brown/pause
4 black/GND
5 grey/auxiliary
Pulse rate, e.g. contact water meter
External activation
3 blue/analogue
2 white/contact
1 brown/pause
4 black/GND
5 grey/auxiliary
External contact function (ProMinent universal signal cable)
Pulse rate, e.g. contact water meter
External activation
2 white/contact
4 brown/GND
External contact function (ProMinent external/contact cable)
External
activation
Page 38
Page 38
ProMinent
®
Dulcodes UV-Desinfektionsanlage
IMPORTANT
• The universal signal cable, the external/contact cable and the level monitor cable should not be less than 1.20 m long, otherwise cable recognition will fail.
Features of the S3Ca metering pumps
5.4 Retrofitting relays
(not with PROFIBUS®)
Delivery range:
1relay circuit set with 2 screw fasteners 1relay cable set with socket 1 seal
Press-out relay opening
WARNING
Disconnect the S3Ca from the mains power supply and rinse liquid end before commencing work (see section 10)!
IMPORTANT
When preparing the opening, ensure that the punch is not forced through the entire pump base! Pump circuits may become damaged.
Place the S3Ca on a firm surface with the relay opening press-out section at the top (see
fig. 21)
Place a punch (dia. 8-15 mm) in the centre of the relay opening press-out section, and
strike briefly and sharply with a hammer (approx. 250 g)
If necessary clean up the edges of the openingRemove the pressed out section from the S3Ca
Inserting the relay component
Hold the relay component with your right hand gripping the left and right hand edges of
the relay cover, and tilt the front end slightly to the left (see fig. 22)
Push the relay component through the relay opening, holding the upper corner of the lower
edge against the guide rail on the pump base, until the contact of the relay component has reached the controller contact. (test: can you still move the end of the circuit back and forth?)
Gently push the relay component right into the openingScrew the relay cover firmly onto the housing using the screws providedInsert the relay cable plug seal into the relay cover and screw on the plug (see fig. 24)The pump is generally programmed ex-factory to drop-out action alarm relay and – if
fitted – „pull-up action clock pulse generator relay. If a switching function is required, the pump can be reprogrammed at the Heidelberg plant.
Fig. 21 Fig. 22
Page 39
Dulcodes UV-Desinfektionsanlage
Page 39
ProMinent
®
Features of the S3Ca metering pumps / Contorl elements
Fig. 23 Fig. 24
Set
Flow
Calib
Mem
ErrorPauseAux
Stop
6 Control elements
Please acquaint yourself with the S3Ca control elements with the help of the control elements and key functions overview!
Indicators The LCD display supports the operation and setting of the S3Ca with a range of indicators:
The indicators are interpreted as follows:
Symbol for P key: The S3Ca is in settings mode. Close symbol: In a continuous display: lock (if code has been set).
In settings mode: indicates access to code menu.
Stop: The S3Ca has been stopped using the STOP/START key. Pause: The S3Ca has been stopped using the pause function
(external).
Aux: The S3Ca is pumping at the auxiliary frequency. In AUX menu:
the S3Ca is in the AUX menu.
Error: A fault has occurred and the pump has been stopped. Mem: An additional memory function has been set in the contact
and batch operating modes. In CNTCT or BATCH menus (mem flashes): the memory function can be set.
Calib: The S3Ca is in the CALIB menu.
In a continuous display (calib flashes): Deviation of the stroke length by more than 10 scale points (e.g. at a stroke length of 40 %, if set smaller than 30 % or greater than 50 %).
Flow: The S3Ca is in the FLOW menu. Set: The S3Ca is in the SET menu. Exclamation mark: The number of strokes reached is above the maximum value
(99999) that can be shown in the LCD display.
NOTE
The S3Ca indicates the metering volume and the metering rate in l or l/hor gal or gal/h only when calibrated.
Page 40
Page 40
ProMinent
®
Dulcodes UV-Desinfektionsanlage
7 Settings
NOTE
• Open out the fold-out page following the title page fully! There you will find the overviews “control elements and key functions” and “operating settings diagram”.
• If no keys are pressed within a period of 1 minute, the S3Ca will return to a continuous display.
Basic information for setting up the S3Ca
P
P
P
3 s
P
3 s
continuous
display
IIAHF
Set
F
Set
= flashes
= Settings option
Confirm entries Press the P key briefly;
you will automatically move to the next menu option or to a continuous display.
Exit menu option
without confirming Press the P key for 3 s:
The entry is cancelled and you will return to a continuous display.
i
1x
2x
!"#
!"#
!"# !"#
i
P
Incremental change
Iof a value Press the i key 1x;
you can toggle between altering the digits of a value (change individual digits = standard) or incremental alteration of a value (change a figure).
Change adjustable values Press UP or DOWN arrow key;
The flashing digit or figure will start to increase or decrease incrementally.
Confirm adjustable values For change individual digits: confirm each digit using the P key. When the last digit has been
confirmed you will automatically move to the next menu option or to a continuous display.
For change a figure; press the P key 1x; you will simultaneously move to the next menu option or to a continuous display.
Correct wrongly set digits Press the i key 2x;
you will go back to the first digit.
Settings
Page 41
Dulcodes UV-Desinfektionsanlage
Page 41
ProMinent
®
Settings
7.1 Check adjustable values
Before setting up the S3Ca you can check the current settings of adjustable values:
Press the i key (“i” as in info) when the S3Ca is in continuous display mode (There is no P key symbol in the LCD display).
Each time you press the i key you will see a different continuous display. The number of continuous displays depends upon the identity code, the selected operating mode and the connected accessories (see overview continuous displays).
7.2 Change to settings mode
If you hold down the P key for 2 seconds in any continuous display, the S3Ca will change to the settings mode. If CODE 1 is set, the code must be entered after pressing the P key.
The following menu options appear first in the settings mode (see also overview operating/ settings diagram):
MODE menu
CODE menu (optional)
SET menu
CLEAR window
In order to adapt the S3Ca to your process requirements you must:
1. Select the operating mode in the MODE menu.
2. If necessary enter the settings for this operating mode in the SET menu. Exceptions: Timer + Profibus
®
.
IMPORTANT
Note the diagram below!
P
2 s
Continuous
display
MODE
menu
SET
menu
CODE
menu
CLEAR
window
1.
2.
7.3 Select operating mode (MODE menu)
The following operating modes are selected via the MODE menu (depending upon identity code, some operating modes may be absent):
Manual: for operation by hand (Identity code, control variant: manual, standard option)
Analogue: for electronic control (Identity code, control variant: analogue current)
Page 42
Page 42
ProMinent
®
Dulcodes UV-Desinfektionsanlage
Settings
Contact: for contact operation (Identity code, control variant: external 1:1 / external with pulse control)
Batch: for batch operation (Identity code, control variant: external with pulse control)
P
Batch
Contact
ManualAnalog
Analog
Manual
Contact
Batch
- ANALOG
- MANUAL
- CONTACT
- BATCH
P
7.4 Settings for operating mode (SET menu)
NOTE
First select the operating mode in the MODE menu! Exceptions: Timer and PROFIBUS
®
.
In the SET menu you can adjust various settings depending upon the selected operating mode.
The following programmable function settings menus appear in all operating modes:
Calibrate (CALIB menu)
Auxiliary frequency (AUX menu)
Flow (FLOW menu, available only if flow monitor is connected)
See also section 7.5!
Further settings menus depend upon the selected operating mode.
7.4.1 Settings for “manual” operating mode
There are no other settings menus in the overall SET menu for the manual operating mode apart from those described in 7.5.
7.4.2 Settings for “analogue” operating mode (ANALG menu)
In addition to those settings menus described in 7.5, there is an additional ANALG menu in the overall SET menu for the analogue operating mode.
The stroke rate is controlled by an analogue electrical signal via the external control terminal.
You can select three signal-processing methods:
0 - 20 mA: at 0 mA the S3Ca does not operate at 20 mA the S3Ca operates at 180 strokes/min. Between these two extremes the stroke rate is proportional to the electrical signal.
PP
P
Continuous
display
glana
Set
02o
mA
Set
Analog
tes
Page 43
Dulcodes UV-Desinfektionsanlage
Page 43
ProMinent
®
Settings
4 - 20 mA: at 4 mA the S3Ca does not operate at 20 mA the S3Ca operates at 180 strokes/min. Between these two extremes the stroke rate is proportional to the electrical signal. For signals of below 3.8 mA a fault will be detected and the S3Ca will stop (e.g. cable break).
Curve: In the curve processing mode you can programme the S3Ca ratios. There are 3 options available:
= straight line
= lower band
= upper band
P
P
P
P P
P
P P
P
Continuous
display
glana
Set
evruc
Set
Analog
nore
Set
Analog
Set
Analog
04o1i
Analog
mA
Set
0212f
Analog
Freq.
Set
06o1f
Analog
Freq.
Set
0612i
Analog
mA
Set
tes
Straight line:
The following symbol appears in the LCD display: . You can enter any stroke frequency ratio for the S3Ca in proportion to the electrical signal. You must enter two points P1 (I1, F1) and P2 (I2, F2). F1 is the stroke rate at which the pump should operate at current I1: the straight line and the ratio are fixed accordingly:
I [mA]
I 1
I 2
F1
F2
F
max
020
P1
P2
Fig. 25
NOTE
Draw a diagram like the one above - with values for (I1, F1) and (I2, F2) - in order to set the S3Ca to your required stroke rate!
Page 44
Page 44
ProMinent
®
Dulcodes UV-Desinfektionsanlage
Settings
Lower/upper band:
This processing mode allows you to control a pump via an electrical signal as shown in the
diagrams below.
Lower band Upper band
e.g. Alkali pump e.g. acid pump
I [mA]
I 1 I 2
F2
F1
020
P1
P2
F
max
I [mA]
I 1
I 2
F1
020
P1
P2
F2
F
max
Fig. 26 Fig. 27
Lower band:
The symbol
appears in the LCD display. The S3Ca will operate below I1 at F1. Above I2, the S3Ca ceases to operate. Between I1 and I2 the stroke rate is between F1 and F2, propor- tional to the signal current.
Upper band:
The signal
appears in the LCD display. The S3Ca will cease to operate below I1. Above I2, the S3Ca will operate at F2. Between I1 and I2 the stroke rate between is F1 and F2, proportional to the signal current.
The smallest processable difference between I1 and I2 is 4 mA.
Error processing In the ER (error) menu option you can activate an error processing function for the curve
mode. An error message appears for signals below 3.8 mA and the S3Ca stops.
7.4.3 Settings for “contact” operating mode (CONTCT menu)
In addition to those settings menus described in 7.5, there is an additional CONTCT in the overall SET menu for the contact operating mode.
The operating mode contact allows you to activate a single stroke or a series of strokes. The strokes can be activated by a pulse or via the external control terminal. This operating mode is intended to transfer input pulses into a reduction (break) or small increase in strokes.
IMPORTANT
The factor resets to “1” if you change to a different operating mode!
Contact - identity code: external with pulse control
Page 45
Dulcodes UV-Desinfektionsanlage
Page 45
ProMinent
®
In the contact - identity code: external with external pulse control you can enter the number of pulses after which a stroke should be carried out. Contact - identity code: external with external pulse control is intended for small dosing quantities.
P
PP
P
Continuous
display
tctnc
Set
no
Set
Mem
Contact
0
Set
Mem
Contact
021
tes
The number of strokes per pulse depends upon the factor, which you can enter. This allows you to vary to a certain extent the input pulses by a factor of 1.01 to 99.99 and/or reduce by a factor of 0.01 to 0.99:
Number of strokes activated = factor x number of input pulses
Examples Factor Pulse (sequential) Stroke number (sequential)
Increase 11 1
21 2
25 1 25
99,99 1 99,99
1.50 1 1.5 (1 / 2)
1.25 1 1.25 (1 / 1 / 1 / 2)
Reduction 11 1
0.50 2 1
0.10 10 1
0.01 100 1
0.25 4 1
0.40 2.5 (3 / 2) (1 / 1)
0.75 1.33 (2 / 1 / 1) (1 / 1 / 1)
Explanation of increase At a factor of 1 For every 1 pulse, 1 stroke is activated
At a factor of 2 For every 1 pulse, 2 strokes are activated At a factor of 25 For every 1 pulse, 25 strokes are activated
Explanation of decrease At a factor of 1 After 1 pulse, 1 stroke is activated
At a factor of 0.5 After 2 pulses, 1 stroke is activated At a factor of 0.1 After 10 pulses, 1 stroke is activated At a factor of 0.75 After 2 pulses, 1 stroke is activated,
then after 1 pulse, 1 stroke is activated, then after 2 pulses, 1 stroke is activated etc.
Settings
Page 46
Page 46
ProMinent
®
Dulcodes UV-Desinfektionsanlage
Settings
NOTE
If a remainder occurs when the factor is processed, the S3Ca counts up the remainder values. When the sum reaches or exceeds “1” the S3Ca will activate a stroke. This ensures that the stroke number corresponds exactly to the factor throughout the dosing operation.
The number of input pulses which have not been processed are stored by the S3Ca in the stroke memory. The stroke memory is limited to the batch size if Memory is not activated (- with Memory at 65535 strokes). You can cancel it by changing to a different operating mode.
You can optimally adapt the S3Ca to the respective process, e.g. in connection with contact water meters.
“Memory” extension function
The memory extension function can be optionally activated (mem appears in the LCD display). Is active gamma/ L adds the remaining unperformed strokes up to a maximum stroke memory capacity of 65535 strokes. If this maximum capacity is exceeded the pump will go into fault mode.
7.4.4 Settings for “batch” operating mode (BATCH menu)
In addition to those settings menus described in 7.5, there is an additional BATCH menu in the overall SET menu for the batch operating mode.
P
P P
P
Continuous
display
hctab
Set
no
Set
Mem
Batch
02451
Set
Mem
Batch
L
tes
The batch operating mode is a variant of the contact operating mode (see 7.4.3). You can pre-select a stroke number (no breaks, whole numbers only from 1 to 65535) as well as a feed quantity (batch). To switch between entries for stroke number and feed quantity press the i key 1x in the corresponding menu option (see also overview operating/settings diagram, fold-out page). The batch operating mode is intended for large dosing quantities.
Metering can be actuated by pressing the P-key or via a pulse from the external control socket”.
The number of input pulses which have not been processed are stored by the S3Ca in the stroke memory. The stroke memory is limited to the batch size if Memory is not activated (- with Memory at 65535 strokes). You can cancel it by changing to a different operating mode.
“Memory” extension function
The memory extension function can be optionally activated (mem appears in the LCD display). If Memory is active gamma/ L adds the remaining unperformed strokes up to a maximum stroke memory capacity of 65535 strokes. If this maximum capacity is exceeded the pump will go into fault mode.
7.5 Settings for programmable functions (SET menu)
The following programmable function settings menus appear in all operating modes:
Calibrate (CALIB menu)
Auxiliary frequency (AUX menu)
Flow (FLOW menu, available only if flow monitor is connected)
Page 47
Dulcodes UV-Desinfektionsanlage
Page 47
ProMinent
®
Settings
7.5.1 Settings for “calibration” function (CALIB menu)
P
P
P
P P
P
Continuous
display
bilac
Set
no
Set
Calib
trats
Set
Calib
tinu
LSet
0
LSet
Calib
2324
tes
Set
Calib
N
002
The S3Ca can also run in calibration mode. The corresponding continuous displays show the current dosing quantities or the feed rate.
The calibration is retained if the stroke length is changed by up to +/- 10 scale points (at a preset stroke length of 40 % the range is 30 % - 50 %). If the stroke rate is altered more than ±10 scale points the yellow warning light is lit, the continuous display flashes and the flashing message calib appears.
NOTE
• Do not go below 30 % stroke length (SEK type: 50 %). This will significantly affect accuracy of calibration.
• Calibration becomes increasingly accurate the more strokes made by the S3Ca during calibration (recommended: at least 200 strokes).
WARNING
If using a hazardous feed chemical, the following setting instructions ensure adequate safety precautions have been taken!
Calibration 왘 Insert the suction tube into a measuring cylinder containing the feed chemical - the
discharge tubing must also be correctly installed (operating pressure,!)
Suck up the feed chemical (press both arrow keys at the same time) when the suction tube
is empty
Note the liquid level in the measuring cylinder and the stroke length
Select the CALIB menu and go the first menu option using the P key
Select ON using an arrow key and change to the next menu option using the P key
To commence calibration, press the P key. The S3Ca starts to pump and displays the
number of strokes (STOP appears at regular intervals)
After a sufficient number of strokes, stop the S3Ca with the P key
Calculate the dosed quantity (difference between the original quantity and the quantity
remaining)
Enter this quantity in the next menu and then go to the next menu option using the P key
Select the unit (L or gal) in the UNIT menu with an arrow key and using the P key
The S3Ca is calibrated. The corresponding continuous displays show the calibrated values. The total stroke number and total litres are set during calibration to “0”.
The S3Ca is in STOP mode.
7.5.2 Settings for “auxiliary frequency” function (AUX menu)
P
P
P
Continuous
display
NK=
Set
Freq.
Set
Aux
#&
JAI
P
Page 48
Page 48
ProMinent
®
Dulcodes UV-Desinfektionsanlage
The programmable function auxiliary frequency allows switching to a different stroke frequency, which can be set in the AUX menu. It can be activated via the external control terminal. When the auxiliary frequency is activated, aux appears in the LCD display.
This auxiliary frequency overrides the current stroke frequency set for the selected operating mode.
7.5.3 Settings for the “flow” function (FLOW menu)
P
P P
P
Continuous
display
wolf
Set
no
Set
Flow
800
Set
Flow
tes
The flow menu only appears when a dosing monitor is connected to the dosing monitor terminal. This dosing monitor registers each discharge stroke of the S3Ca at the discharge connector and transmits it back to the S3Ca. If this response transmission is serially omitted for a period set in the FLOW menu (due to failure or below-minimum dosing) the S3Ca stops.
7.6 Setting code (CODE menu)
The code menu is used to select whether you want to prevent access to parts of the settings options.
P
P P
Continuous
display
edoc
1edoc
2345
In the first menu option you can choose CODE 1 or CODE 2 (both use the same number).
Select CODE 1 to prevent access to the settings mode (➀ in the overview operating/ settings diagram, fold-out page). In the next menu option, enter the number you wish to use as the code.
Select CODE 2 to prevent access to the settings options for directly alterable values in the continuous displays ( in the overview operating/settings diagram, fold-out page). In the next menu option, enter the number you wish to use as the code.
Select NONE to remove a pre-set security lock.
7.7 Cancel total stroke number or total litres (CLEAR window)
In the CLEAR window you can delete the stored total stroke number and simultaneously the total litres (= set to “0”). You may then press the P key briefly to exit this window.
The values displayed are counted incrementally from the point of commissioning the pump, or from the last delete action.
P
Continuous
display
raelc
L
N
Page 49
Dulcodes UV-Desinfektionsanlage
Page 49
ProMinent
®
Operating
8 Operating
This section describes all operating options available to you when the S3Ca is in continuous display mode (no P key symbol in the LCD display).
NOTE
• Open out the fold-out page following the title page fully! There you will find the
overviews “control elements and key functions” and “operating/settings diagram”.
• Look at the overview “continuous displays”. This page shows you which displays are
available in which operating mode, and which values are directly alterable in the corresponding continuous displays.
8.1 Manual operation
Set stroke length Stroke length is continually adjustable within a range of 0-100 %. The recommended stroke
length range, which will practically guarantee technical reproducibility, is 30-100 % (SEK type: 50-100 %).
NOTE
At low stroking rates (less than 1/3 maximum stroking rate) the controller switches to digital stroking mode. This ensures adequate cooling of the motor at low stroking rates.
The following operating options are available via the different keys (see also figure on the next page):
Stop/Start S3Ca To stop S3Ca: press STOP/START key.
To start S3Ca: press STOP/START key.
Start batch Press the P key briefly in batch operating mode.
Load factory settings Press the P key for 15 s to load factory calibration settings!
Current settings will be deleted.
Change to settings mode WeIf you press the P key for 2 s in any continuous display the S3Ca will change to settings
mode (see section 7). If CODE 1 is set, the code must be entered after pressing the P key.
Check adjustable values Each time you press the i key you will see a different continuous display. The number of
continuous displays depends upon the identity code, the selected operating mode and the connected accessories.
Change directly
alterable values To change a value (see below) directly in the corresponding continuous display, press one of
the arrow keys until set appears in the LCD display. The delay has been programmed in to prevent inadvertent changing of values.
If CODE 2 has been set, this code must be entered after pressing the arrow key.
Directly alterable values are as follows:
Stroke rate In manual, contact and batch operating modes:
The stroke rate can be altered in the stroke rate display.
Feed rate In manual operating mode
The feed rate can be altered in the feed rate display.
Factor The factor is the number of strokes activated by an external pulse or a press of the P key (in
batch mode only).
In batch operating mode: You can alter the factor from the “remaining strokes display. The S3Ca returns to the original continuous display a few seconds after the factor has been reset.
Display program version Press the P-key for 10 seconds to display the program version.
Example: V 1052 + X 1010. Release key immediately if LOAD 3 appears !
Page 50
Page 50
ProMinent
®
Dulcodes UV-Desinfektionsanlage
Operating / Troubleshooting
Batch size In batch operating mode:
The batch size can by changed from the batch size/remaining litres display. The S3Ca returns to the original continuous display a few seconds after the batch size has been reset. In the permanent display Stroke rate
Priming The priming function is activated by pressing both arrow keys at the same time.
Cancel error Error messages are cancelled by pressing the P key briefly.
Settings
mode
P
P
P
i
STOP
STOP
START
START
Continuous
display
2 s
Stopp/start pump
Change directly alterable values
= Security lock (CODE 1)
= Security lock (CODE 2)
Prime
Start batch (in "batch" operating mode only)
Cancel error
Check adjustable values
2
2
1
1
8.2 Remote control
Remote control of the S3Ca is possible via a control cable or PROFIBUS® (see Section 5.3 and Chapter 7, Supplementary instructions for ProMinent® gamma/ L and ProMinent® Sigma versions with PROFIBUS®“ as well as your documentation in the annex).
9Troubleshooting
WARNING
• Always take suitable precautions when using hazardous chemicals!
• Ensure the equipment is de-pressurised before working on the pump!
The pump does not prime despite full stroke and ventilation
Cause Crystalline deposits on the ball seat because valves have dried out.
Remedy Remove the suction sleeve from the chemical supply container and rinse out the liquid and
thoroughly.
If still unsuccessful, dismantle valves and clean.
Fluid is seeping from the top plate
Cause The liquid end is not sealed against the pump diaphragm.
Remedy Tighten screws in the liquid end.
If unsuccessful, replace the diaphragm (see section 4.3).
Page 51
Dulcodes UV-Desinfektionsanlage
Page 51
ProMinent
®
Troubleshooting
Green LED indicator (operating display) is not lit
Cause Incorrect or no mains voltage.
Remedy Use the recommended mains voltage as given in the voltage specification on the
nameplate.
Error Messages
Red LED display is lit, “Error” and “MINIM” flash in the display
Cause Fluid level in the chemical storage tank has reached liquid level low, stage 2”.
Remedy Fill the chemical supply container.
Red LED display is lit, “Error” and “ANALG” flash in the display
Cause S3Ca is in “analogue operating mode, a fault routine has been programmed in the ANALG
menu and the operating current has fallen below 3.8 mA.
Remedy Remedy low operating current.
Switch fault routine OFF (see section 7.4.2.).
Red LED display is lit, “Error” and “CNTCT” flash in the display
Cause S3Ca is in contact or batch operating mode and the extended function memory has been
set. In addition a very large factor has been entered, too many contacts have been input or the P­key has been pressed too often, resulting in an overflow of the stroke memory.
Remedy Press the P-key, saved data will be deleted.
Change S3Ca set up.
Red LED display is lit, “Error” and “FLOW” flash in the display
Cause Dosing monitor not properly connected.
Remedy Connect dosing monitor properly.
Press P-key.
Cause Dosing monitor has reported more defective strokes than have been set in the FLOW menu.
Remedy Press P-key.
Investigate the cause and remedy.
Red LED is lit. “Error” appears in the display and “MOTOR” is flashing
Cause The motor is not operating accurately because the backpressure is too high.
Remedy Reduce backpressure.
Press the P key (reset key).
Cause The motor is overheating.
Remedy Check ambient temperature (max. 40 ºC).
Allow motor to cool down.
Press the P key (reset key).
Cause Other motor fault.
Remedy Call ProMinent.
Press the P key (reset key).
Red LED is lit. “Error” appears in the display and “TEMPERATURE” is flashing
Cause The temperature in the pump housing is too high because the ambient temperature is too high.
Remedy Reduce ambient temperature.
Allow motor to cool down.
Press the P key (reset key).
Cause The temperature in the pump housing is too high because the pump is consuming too much power.
Remedy Check installation, rectify if necessary.
Allow motor to cool down.
Press the P key (reset key).
Page 52
Page 52
ProMinent
®
Dulcodes UV-Desinfektionsanlage
Troubleshooting / Decommissioning and disposal
Red LED display is lit, “Error” appears in the display and “FAN” is flashing
Cause Fault related to fan in pump housing.
Remedy Check fan and replace if necessary.
Press the P key (reset function).
Red LED display is lit, “Error” appears in the display and “SYSTEM” is flashing
Cause Controller fault.
Remedy Disconnect the pump from the mains and reconnect.
If the error message continues, send the pump back to ProMinent.
Red LED lit, “Error” appears in the display and “Mem” flashes
Cause Stroke memory full
Remedy Eliminate causes
Press P-key (consider the consequences on your process)
All other Errors
Please contact your ProMinent branch or representative!
Fault Signals
Yellow LED display is lit
Cause Liquid level in chemical storage tank has reached liquid level low, stage 1”.
Remedy Fill chemical storage tank.
Yellow LED Display is lit and “calib” flashes
Cause The pump is calibrated and the stroke length deviates by more than ±10 % from the value at
the time of calibration.
Remedy 왘 Reset the stroke length or calibrate the pump again to the desired stroke length.
10 Decommissioning and disposal
Decommissioning
WARNING
• When decommissioning the pump the housing and, in particular, the liquid end must be thoroughly cleaned to remove chemicals and dirt!
• Always take suitable precautions when using hazardous chemicals!
• Ensure that the equipment is de-pressurised!
Disconnect the pump from the power supply.
Empty the liquid end by turning the pump upside down and allow the feed chemical to pour
out.
Rinse the liquid end with a suitable material, thoroughly rinse the liquid end after use with
hazardous materials!
If decommissioning is only temporary, maintain the correct storage conditions:
Storage temperature: -10 to +50 °C
Air humidity: < 92 % relative humidity
Disposal
WARNING
Spring under tension! Ta ke particular care when disassembling the pump as the return spring (Item 5, Chapter 2.2)
is under considerable mechanical tension!
IMPORTANT
Observe your locally applicable regulations (particularly with regard to electronic waste and transmission fluid)
Page 53
Dulcodes UV-Desinfektionsanlage
Page 53
ProMinent
®
11 Spare parts and accessories
CAUTION
The assembly and installation of ProMinent
®
metering pumps with other-make parts that are not tested and recommended by ProMinent are not permitted and can lead to personal injury and damage to property for which no liability shall be accepted!
Spare parts
You will find the order numbers for the wearing parts in the exploded view drawings in the annex. If you require further parts, please order the Spare parts list ProMinent Sigma/ 3”.
Actuator for automatic stroke length adjustment, actuating period approx. 1 sec for 1 % stroke length, 1 response signal potentiometer, enclosure rating IP 54.
Controller consists of actuator with servomotor and integrated servo control for stroke length adjustment via a standard signal. Standard signal input 0/4-20 mA, corresponds to stroke length 0 - 100 %. Automatic/manual operation selection key for manual stroke adjustment. Mechanical status display of actual stroke length value output 0/4-20 mA for remote display.
Variable speed motors with integrated speed controller (identcode characteristic V)
Power supply 1 ph 230 V, 50/60 Hz, 0.55 kW External control with 0/4-20 mA
Speed controllers in metal housing (identcode characteristic Z)
The speed controller assembly consists of a speed controller and a 0.55 kW variable speed motor.
Float switches
2-stage, with 2 m connection cable
Alarm relays
For signalling faults
Alarm and clock pulse generator relays
For cyclic timing of other devices and for signalling faults.
Control cables
Universal control cable 5-core/2.5 and 10 m External contact cable 2-core/2.5 and 10 m
Foot valves
With intake filter and non-return ball for connection at end of intake line.
Metering valves
With spring-loaded non-return ball for metering in open or closed systems and for mounting the metering line.
Backpressure valves
For exact metering at low operating pressure or as overflow safety valve.
Accumulators
For pulsation damping in long metering lines.
Metering monitors
For monitoring metering operations. After an adjustable number of non-acknowledged metering strokes, a fault is indicated and the metering pump shut down.
Intake assemblies
With foot valve and float switch for expendable packing drums or metering tanks.
Metering tanks
From 35 to 1000 l capacity with lockable screw cover and necessary accessories.
Manual/electric stirrers
For mixing and preparing metering solutions.
Spare parts and accessories
Page 54
Page 54
ProMinent
®
Dulcodes UV-Desinfektionsanlage
Motor-Typ AF71/4B-7 Leistungsfaktor 0,70/0,70
motor type power factor type du moteur facteur de puissance
Maschinenart 3-Ph. Motor Wirkungsgrad 70 % type of machine efficiency désignation rendement
Schutzart IP55 Bemessungsfrequenz 50/60 Hz protection class rated frequency degré de protection fréquence nominale
Bauform IMV1 Bemessungsdrehzahl 1420/1720 U/min mounting rated speed rpm construction vitesse nominale t/mn
Bemessungsleistung 0,370 kW Wärmeklasse F rated output temperature class puissance nominale classe d’isolement
Bemessungsspannung
/ Anzugsstrom 4,4 fach
rated voltage 400/230 V starting current fold tension nominale courant de démarrage fois
Bemessungsstrom 1,30/2,30 (50 Hz) Anzugsmoment 2,4 fach rated current 1,10/1,90 (60Hz) starting torque fold courant nominale couple de démarrge fois
Geprüft nach / Kippmoment 3,2 fach tested in acc. with pull-out torque fold contrôlé selon couple de décrochage fois
PTB Nr. / Umgebungstemperatur 40 °C
ambient temperature température ambiante
Schaltung
/ connection branchement
Anmerkung 400/230 V comments 380-420/220-242 V (50 Hz) abservation 380-460/220-265 V (60 Hz)
ProMinent
Pumpentyp S3Ba _ _ _ _ _ _ _ _ S _ _ _
HP2a _ _ _ _ _ _ _ _ S _ _ _
Motor data sheet
Motor Datenblatt / Motor data sheet / Fiche technique pour moteur
Bestell Nr. 1003455/A Hersteller ATB order no. / no. de commande producer / fabricant
Motor datasheets are available for further information.
Special motors and special motor flanges are possible on request.
ProMinent Dosiertechnik GmbH · 69123 Heidelberg · Germany Nr./No. MD - 1003455/A Datum/Date 08.08.2002
Page 55
Dulcodes UV-Desinfektionsanlage
Page 55
ProMinent
®
EC Declaration of Conformity
Page 56
Page 56
ProMinent
®
Dulcodes UV-Desinfektionsanlage
Exploded diagrams of liquid ends
Delivery unit Sigma/ 3 330 PVT for identity code types: S3Ba/S3Ca 120145, 120190, 120270, 120330
Spring **
Ball *
Ball seat *
Valve assy DN 25/PVT* Order No. 740615
Valve assy DN 25/PVT* Order No. 740615
Diaphragm FM 330 Order No. 1004604
Spare parts kit FM 330 PVT/PPT/PCT Order No. 1005308.
* The listed items are constituent parts of the spare part kit.
** Special accessories (not included in spare part kit).
Subject to technical modifications.
Fig. 28
61_05-104_0_72-03_330
Page 57
Dulcodes UV-Desinfektionsanlage
Page 57
ProMinent
®
Exploded diagrams of liquid ends
Delivery unit Sigma/ 3 1000 PVT/PPT/PCT for identity code types: S3Ba/S3Ca 070410, 070580, 040830, 041030
Valve spring *
Valve plate *
Valve plate seat *
Valve assy DN 32/PVT/PPT/PCT*
Order No. 1002806
Valve assy DN 32/PVT/PPT/PCT *
Order No. 1002806
Diaphragm FM 1000 Order No. 1002835
Spare parts kit FM 1000 PVT/PPT/PCT Order No. 1005309.
* The listed items are constituent parts of the spare parts kit.
Subject to technical modifications.
Fig. 29
61_05-104_0_72-03
Page 58
Page 58
ProMinent
®
Dulcodes UV-Desinfektionsanlage
For other spare parts see delivery unit without overflow valve (see P. 54 and 55).
Subject to technical modifications.
Fig. 30
61_05-104_0_74-03_330
Exploded diagrams of liquid ends
Delivery unit Sigma/ 3 330 PPT/PCT/PVT ÜV-A for identity code types: S3Ba/S3Ca 120145, 120190, 120270, 120330 Delivery unit Sigma/ 3 1000 PVT/PPT/PCT ÜV-A for identity code types: S3Ba/S3Ca 070410, 070580, 040830, 041030
Overflow valve assy 10 bar PVA Order No. 1005626
Overflow valve assy 7 bar PVA Order No. 1004801
Overflow valve assy 4 bar PVA Order No. 1004778
Page 59
Dulcodes UV-Desinfektionsanlage
Page 59
ProMinent
®
Fig. 31
61_05-104_0_73-03_330
Exploded diagrams of liquid ends
Delivery unit Sigma/ 3 330 SST for identity code types: S3Ba/S3Ca 120145, 120190, 120270, 120330
Spring **
Ball *
Ball seat *
Valve assy FM 330 SST * Order No. 803708
Diaphragm FM 330 Order No. 1004604
Valve assy FM 330 SST * Order No. 803708
Spare parts kit FM 330 SST without valve Order No. 1005310.
Spare parts kit FM 330 SST with valve Order No. 1005312.
* The listed items are constituent parts of the spare parts kit.
** Special accessories (not included in spare parts kit).
Subject to technical modifications.
Page 60
Page 60
ProMinent
®
Dulcodes UV-Desinfektionsanlage
Spare parts kit FM 1000 SST without valve Order No. 1005311
Spare parts kit FM 1000 SST with valve Order No. 1005313
* The listed items are constituent parts of the spare parts kit.
Subject to technical modifications.
Exploded diagrams of liquid ends
Delivery unit Sigma/ 3 1000 SST for identity code types: S3Ba/S3Ca 070410, 070580, 040830, 041030
Fig. 32
61_05-104_0_73-03
Valve spring *
Valve plate *
Valve plate seat *
Valve assy FM 1000 SST * Order No. 1002811
Diaphragm FM 1000 Order No. 1002835
Valve assy FM 1000 SST * Order No. 1002811
Page 61
Dulcodes UV-Desinfektionsanlage
Page 61
ProMinent
®
For other spare parts see delivery unit without overflow valve (see P. 57 and 58).
Subject to technical modifications.
Exploded diagrams of liquid ends
Liquid end Sigma/ 3 330 SST ÜV-A for identity code types: S3Ba/S3Ca 120145, 120190, 120270, 120330 Liquid end Sigma/ 3 1000 SST ÜV-A for identity code types: S3Ba/S3Ca 070410, 070580, 040830, 041030
Fig. 33
61_05-104_0_75-03_330
Overflow valve assy 12 bar SSA Order No. 1005625
Overflow valve assy 7 bar SSA Order No. 1005042
Overflow valve assy 4 bar SSA Order No. 1005038
Page 62
Page 62
ProMinent
®
Dulcodes UV-Desinfektionsanlage
Exploded diagrams of liquid ends
Retrofit kit double diaphragm S3Ba/S3Ca
Abb. 34
61_05-104_00_53-03_2
S3Ba Retrofit kit double diaphragm FM 330 Order No. 1004596
S3Ba Retrofit kit double diaphragm FM 1000 Order No. 1004594
S3Ca Retrofit kit double diaphragm FM 330 Order No. 1004597
S3Ca Retrofit kit double diaphragm FM 1000 Order No. 1004595
* These items belong to the retrofit kit.
Subject to technical modifications.
Diaphragm failure detector *
Lense Order No. 792807
Page 63
Dulcodes UV-Desinfektionsanlage
Page 63
ProMinent
®
Wiring diagram
Stroke actuator wiring diagram
Wiring diagram for stroke length adjuster
N
P1
P2
E
-
Sig.
V+
3 2
1
5
6
7
4321
321
Feedback signal mA
Input signal mA
PE N L
Power supply
Power supply