Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176
TestEquipmentDepot.com
SATELLITE RECEIVER & CABLE TESTER
RP-080
- 0 MI1483 -
SAFETY NOTES
Read the instruction manual before using the equipment, mainly
"SAFETY RULES" paragraph.
The symbol
MANUAL". In this manual may also appear as a Caution or
Warning symbol.
Warning and Caution statements may appear in this manual to
avoid injury hazard or damage to this product or other property.
on the equipment means "SEE USER’S
TABLE OF CONTENTS
1
GENERAL INFORMATION .....................................................1
4.2 Internal fuses which user cannot replace ..........................12
English
11/06 RP-080
11/06 RP-080
SATELLITE RECEIVER &
CABLE TESTER
RP-080
1 GENERAL INFORMATION
1.1 Description
The RP-080 is a handy, versatile and easy to use signal
generator with which satellite receivers and coaxial cables of
buildings can be checked.
1.2 Specifications
RECEIVER TEST MODE
Frequency
Pilot carriers
UHF Band85 MHz and 750 MHz
L Band (IF Sat) 1000 MHz and 2150 MHz
Accuracy± 100 kHz
Level 75 to 100 dBµV (selectable in 1 dB
Accuracy
UHF Band ± 2 dB L (FI Sat) Band ± 3 dB
LEDs Carrier output level (individually)
Voltage and 22 kHz
Indication 13 V yellow LED illuminated
13 V + 22 kHz yellow LED flashes
18 V blue LED illuminated
18 V + 22 kHz blue LED flashes
11/06 - 1 - RP-080
steps)
English
Connector F female (input/output)
Power supply 12 - 18 V / 120 mA (by means of
RF cable or external DC supply)
Equipment consumption 3 W
Environmental operating conditions
Altitude: up to 2000 m
Temperature range: from 5° C to 40° C
Maximum relative
humidity: 80% (up to 31° C), decreasing
lineally up to 50% at 40° C.
Mechanical features
Dimensions 77 mm W x 85 mm H x 28 mm D
Weight 150 g
OPTIONAL ACCESSORIES
CC-030 F/m - F/m coaxial cable
AD-058 F/m - F/f quick adapter
AL-032 230 V UK mains adapter
11/06 - 2 - RP-080
2 SAFETY RULES
* Use this equipment connected only to devices or
systems with their common at ground potential.
* External AC adapter can be used in Overvoltage
Category II, installations and Pollution Degree 1
environment, Only indoor use.
* When using some of the following accessories use only
the specified ones to ensure safety:
Power adapter
* Use this instrument under the specified environmental
conditions.
* Remenber that voltages higher than 70 V DC or 33 V AC
rms are dangerous.
* Use for the signal inputs / outputs, specially when working
with high levels, appropriate low radiation cables.
* Follow the cleaning instructions described in the
Maintenance Paragraph.
English
11/06 - 3 - RP-080
* Symbols related with safety:
DIRECT CURRENT
ALTERNATING CURRENT
DIRECT AND ALTERNATING
GROUND TERMINAL
PROTECTIVE CONDUCTOR
FRAME TERMINAL
EQUIPOTENTIALITY
ON (Supply) / OFF (Supply)
DOUBLE INSULATION
(CLASS II protection)
CAUTION
(Risk of electric shock)
CAUTION (Refer to manual)
FUSE
11/06 - 4 - RP-080
2.1 Descriptive Examples of Over-Voltage Categories
Cat I Low voltage installations isolated from the mains
Cat II Portable domestic installations
Cat III Fixed domestic installations
Cat IV Industrial installations
English
11/06 - 5 - RP-080
11/06 - 6 - RP-080
3 OPERATING INSTRUCTION
3.1 Description of the controls and elements
6
V
7
8
ext.
95959595
85858585
75757575dBµV
18 V13 V 22 k
5
1
2
3
LOCK
ON
OFF
4
Figure 1.- Front view
[1] IF OUTPUT Output connector
Frequency pilots output. This jack will be connected with
the IF input jack (antenna input) of the signal receiver.
[2] PILOT LEVEL INDICATORS
LED indicators in red colour corresponding to the output
level of every carrier signal (in 1 dB steps).
[3] PILOT LEVEL SELECTION BUTTONS
Each button allows output level selection for a single
frequency carrier (in 1 dB steps).
11/06 - 7 - RP-080
English
Note: When two contiguous LEDs appear lit the level is 1
dB higher than this one stated by the lower LED. (See
an example in the next figure).
V
ext.
18 V13 V22 k
95959595
85858585
75757575dBµV
(86 dBµv)(85 dBµv)(87 dBµv) (89 dBµv)
Figure 2.- Output level Indication in dBµV
[4] OFF-ON-LOCK Power on/off switch / Output levels
OFF Instrument power-off (deactivates the
ON Activates the output levels
LOCK Locks the output levels
[5] H ( 18 V )Blue LED for 18 V
This LED will be illuminated, if on the coaxial line is
present a 18 V supply voltage. If in addition, a 22 kHz
switching signal is superimposed on the 18 V supply
voltage, this LED will flash.
11/06 - 8 - RP-080
locking
output levels)
[6] V ( 13 V )Yellow LED for 13 V
This LED will be illuminated, if on the coaxial line is
present a 13 V supply voltage. If in addition, a 22 kHz
switching signal is superimposed on the 13 V supply
voltage, this LED will flash.
[7] VextC INPUTGreen LED states external power supply
Connector to power the instrument through an external
DC source (13-18 V / 120 mA).
[8] DC INPUTDC power supply adapter jack
Jack to connect external DC power supply (12-18 V / 120
mA).
3.2 Operating Instructions
3.2.1 Using combined with a TV level meter
The RP-080 has been specially designed for using joint to
PROMAX’s TV level meters, which are able to tune the Satellite and Terrestrial band like PRODIG-5
EXPLORER,
PROLINK-4/4C Premium, PROLINK-3/3C Premium or
MC-577.
English
11/06 - 9 - RP-080
MAIN VIDEO SIGNAL
DISTRIBUTION
PANEL
CO-AXIAL
CABLE
CABLE TV
OR
SAT
ANTENNA
SIGNAL
V
18 V13 V 22 k
ext.
95 95 95 95
85 85 85 85
75 75 75 75dBµV
ONLOCK
TEST SIGNAL
OFF
GENERATOR
RP-80
V
18 V13 V 22 k
ext.
95 95 95 95
85 85 85 85
75 75 75 75dBµV
ONLOCK
OFF
RP-80
TEST SIGNAL
GENERATOR
TV JACK OUTLET
RF METER IN
Figure 3.- Checking a TV SAT - UHF installation.
1.- Separate the installation section that is desired to check
from the general panel or from one of the jack outlets of
the TV signal distribution network.
2.- Connect the RP-080 OUTPUT [1] connector to one of the
ends from section under test, and use the TV level meter
(RF input) on the other.
3.- Select on RP-080, depending on the presence of
amplifiers in the line, the output levels for each carrier by
means the pilot level selection buttons [3].
4.- Turns on the level meter, select the TERRESTRIAL (UHF)
or SATELLITE (IF) band, select the representation of the
spectrum in the whole band (Full Span) and set as
maximum a 100 dBµV reference level.
11/06 - 10 - RP-080
5.- Verify on the TV level meter screen in the SPECTRUM
ANALYSER mode the presence of the two pilot
frequencies generated by the RP-080 as well as the
received signal level to evaluate the attenuation value
from line. Adjust the frequency span to a suitable margin.
6.- Repeat the two steps previously described in order to
verify the following frequency band.
Consequently, the correct equalisation of the selected
installation section will be able to be verified.
IMPORTANT REMARK:
Video carriers generated by RP-080 are not modulated,
therefore do not try to visualize a video picture on TV
receiver or TV level meter since these equipments only
demodulate AM signals.
It is possible to verify the pilot signal level using the
SPECTRUM analyser mode on a TV level meter.
English
11/06 - 11 - RP-080
4 MAINTENANCE
The method of maintenance to be
consists of cleaning the cover. All other operations should be
carried out by authorised agents or by personnel qualified in
the service of instruments.
carried out by the user
4.1 Cleaning recommendations
CAUTION
Do not use scented hydrocarbons or chlorides solvents.
Such products may attack the materials used in the
construction of the cover.
The cov
of detergent and water applied with a soft cloth.
er should be cleaned by means of a light solution
Dry thoroughly before using the system again.
4.2 Internal fuses which user cannot replace
The following fuse mus
personnel:
F1 0.5 A SLOW 125 V SMD
11/06 - 12 - RP-080
t be replaced by authorized
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.