PROMAX PROMAX PROLITE-17 Manual

Page 1
OPTICAL INSTRUMENTS SERIES
PROLITE-17
User's Guide to the PROLITE-17
Mini Optical Power Meter
Optical PowerMeter
v1.0 0 DG0179 (30-09-2014)
Specifications
Type Display Range Resolution(dB) Calibrated Wavelength (nm) Sensor Type Accuracy Working Wavelength (nm) Continuous Working Hours Power Source Working Temp Storage Temp Accessory Dimension
1
Note:
1
With 1550 nm mode, under 23 °C ± 3 °C test condition.
2
New battery,under 23°C±3°Ctestcondition.
Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com
PROLITE-17
Description
PROLITE-17 Pen type optical power meter has compact structure and stable performance, ensure high measuring precision of 850 nm, 1300 nm, 1310 nm, 1490 nm, 1550 nm and 1625 nm wavelengths. Use together with GS series optical source could accurately measure the loss of fiber, cable and other passive optical device.
Control Panel
6
1 2
Features
InGaAs sensor head.
2.5 mm universal interface(support FC/SC/STconnectors). Low power consumption, continously work more than 80 hours. Linear optical power and logarithmic power display. Power remains indication. Relative value measurement function. Compact and portable design.
8
Optical PowerMeter
PROLITE-17
+10 ~ -70 dBm @1550 nm
0.01
850/1300/1310/1550/1490/1625
InGaAs
0.35 dB ±1 nW
2
7
3
About 80 hours(stand-by time: About1600 hours)
Operates with twoAAA batteries
2 pieces ofAAA batteries, Quick guide, Packing box, Carrying case
L120 mm * W33 mm * H30 mm / About 70 g
Num.
1
2
Icon
850/1300/1310/
1490/1550/1625 nm
-51.99 dBm
3 4
54
5
6 7 8
Interface Dust Cap
Battery Compartments
800 ~ 1700
-0 ~ +40 °C; <90% RH ~°
-20 +70 C; <90 % RH
Description
Display current wave length.
Display current power value.
Indicate remainingcapacity of batteries.
Power Switch:
long press short press
short press
wavelengths.
long pres
2.5 mm standard interface. Resist dust for interface. Install with 2* AAA batteries.
( 2 s) to turnon/off the power.
( 1.5 s) to turnon/off backlight.
:Fn button
( 1.5 s) to switchbetween
( 2 s) to setreference value.
PROLITE-17