OD-603/606
QUICK REFERENCE GUIDE
FRONT PANEL
1
7
6
Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176
TestEquipmentDepot.com
2
3
4
5
Power ON/OFF
1
Display area
2
Control (key and knob) area
3
Probe Compensation: Measurement signal (5V/1KHz) output
4
RIGHT SIDE PANEL
EXT Trigger Input
5
Signal Input Channel
6
7
Menu off
8
9
10
11
12
USB Host port
8
USB Device port
9
COM / VGA port (Optional)
10
Trigger signal output & Pass/Fail output port
11
12
LAN port

OD-603/606
REAR PANEL
QUICK REFERENCE GUIDE
13
14
15
16
CONTROL KEY AREA
13
Handle
14
Air vents
AC power input jack
15
16
Fuse
17
Foot stool
17
18
19
20
25
24
Multipurpose knob
18
Function key area
19
Trigger control area
20
Horizontal control area
21
Vertical control area
22
Menu off
23
Menu option setting (H1-H5)
24
Menu option setting (F1-F5)
25
21
22
23

OD-603/606
USER INTERFACE
QUICK REFERENCE GUIDE
23
22
21
20
1
2
3
4
5
6
7
8
9
10
11
12
13
14
1819
Waveform Display Area.
1
The state of trigger, including:
2
Auto:
Trig:
Ready:
Scan:
Stop:
3
The purple T pointer indicates the horizontal position for the trigger.
4
The pointer indicates the trigger position in the internal memory.
5
The two yellow dotted lines indicate the size of the viewing
expanded window.
6
It shows present triggering value and displays the site of present
window in internal memory.
Automatic mode and acquire waveform without triggering.
Trigger detected and acquire waveform.
Pre-triggered data captured and ready for a trigger.
Capture and display the waveform continuously.
Data acquisition stopped.
17
1516
7
It shows setting time.
It indicates that there is a U disk connecting with the oscilloscope.
8
9
The positions of two purple dotted line cursors measurements.
10
The purple pointer shows the trigger level position for CH1.

OD-603/606
11
The waveform of CH1.
12
The waveform of CH2.
13
The frequency of the trigger signal of CH1.
It indicates the current function menu.
14
Current trigger type:
15
Rising edge triggering.
Falling edge triggering.
Video line synchronous triggering.
Video field synchronous triggering.
The reading shows the trigger level value of the corresponding channel.
The reading shows the window time base value.
16
The reading shows the setting of main time base.
17
QUICK REFERENCE GUIDE
The readings show current sample rate and the record length.
18
19
It indicates the measured type and value of the corresponding channel.
F: Means frequency.
T: Means cycle.
V: Means the average value.
Vp: The peak-peak value.
Vk: The root-mean-square value.
Ma: The maximum amplitude value.
Mi: The minimum amplitude value.
Vt: The Voltage value of the waveform's flat top value.
Vb: The Voltage value of the waveform's flat base.
Va: The amplitude value.
The readings indicate the corresponding Voltage Division and the Zero Point positions of the
20
channels. The icon shows the coupling mode of the channel.
"—" indicates direct current coupling.
"~" indicates AC coupling.
" " indicates GND coupling.
It is cursor measure window, showing the absolute values and the readings of the two
21
cursors.
Os: The overshoot value.
Ps: The Preshoot value.
RT: The rise time value.
FT: The fall time value.
PW: The +D width value.
NW: The D Width value.
+D: The +Duty value.
-D: The -Duty value.
PD: The Delay A B value.
ND: The Delay A B value.
The yellow pointer shows the grounding datum point (zero point position) of the waveform
22
of the CH2 channel. If the pointer is not displayed, it shows that this channel is not opened.
The red pointer indicates the grounding datum point (zero point position) of the waveform
23
of the CH1 channel. If the pointer is not displayed, it shows that the channel is not opened.
v1.0
OD-603/606
29-05-2014 (0 DG0149)