PROMAX PROMAX AE-366 Quickstart

AE-366B
mзпЙк=лзЕвЙн
rp_=_=éçêí
sd^=éçêí
pÉÅì êáíó=ëäçí
c~å
cмеЕнбзе=hЙул
jÉåì= hÉóë
mзпЙк=Дмннзе
i `a=a áëéä~ó
^êêçï=âÉóë
oc=fеймн= нЙкгбе~д
pЕкздд=пЬЙЙд
rp_=^=éçêí
hÉóé~Ç=~åÇ=ìåáí=âÉóë
kмгЙкбЕ=qЙкгбе~д
Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com
QUICK REFERENCE GUIDE
FRONT VIEW
1
2
3
i` a =aáëéä~ó
1
pЕкздд=пЬЙЙд
5
9
rp_=^=éçêí
4
5
6
7
8
9
10
mзпЙк=Дмннзе
2
cмеЕнбзе=hЙул
3
jÉåì= hÉóë
4
REAR PANEL
11
12 13
^êêçï=âÉóë
6
hÉóé~Ç=~åÇ=ìåáí=âÉóë
7
oc=fеймн= нЙкгбе~д
8
kмгЙкбЕ=qЙкгбе~д
10
15
14
11
12
rp_=_=éçêí
op=OPO=éçêí
sd^=éçêí
13
pЙЕмкбну=лдзн
14
c~å
15
mзпЙк=лзЕвЙн
16
16
AE-366B
0
1
4
7
2
5
8
3
6
9
MHz / mSec
dB
Enter
GHz /
Sec
kHz / µSec
BK SP
MENU KEYS
QUICK REFERENCE GUIDE
cкЙимЙеЕу
pé~å
^гйдбнмЗЙ
^мнзлЙн
j~êâÉê
mÉ~â
pÉ~êÅÜ
Sets the center frequency, start frequency, stop frequency and step frequency.
Sets the span, with options for full span, zero span and last span.
Sets the amplitude reference level, scale and amplitude units.
Automatically searches the peak signal with maximum amplitude and displays it with appropiate horizontal and vertical scales.
The Marker key is used to configure the markers, as well as other related functionality.
Finds each maximum and minimum peak. Used with the Marker functions.
_t
qê~ÅÉ
aáëéä~ó
jЙгзку
mкЙлЙн
e~кЗЕзйу
Sets the resolution bandwidth.
Sets traces and trace related functions.
The Display key configures the split­screen windowing mode and the basic display properties.
The memory key is used to save or recall setup, trace and limit line data.
The Preset key will restore the spectrum analyzer to the factory settings.
The hardcopy key is a quick save key that will save a screen-shot of the display.
jÉ~ë
Configures ACPR and OCBW measurements.
iáãáí=iáåÉ
Sets and tests Pass/Fail limit lines.
NUMERIC TERMINAL
e~кЗЕзйу
pÉíìé
pулнЙг
Configures the hardcopy options.
The System key is used to configure the RS232 interface, language, update the firmware as well as other system options.
The numeric keypad is used to enter values and parameters.
It is often used in conjuction with the arrow keys and scroll wheel.
To confirm a value press the Enter key .
âeòL
båíÉê
‘pÉÅ
SCROLL WHEEL
Edit values, select listed items.
ARROW KEYS
Increment/decrement values (in steps), select listed items.
AE-366B
RF INPUT 50
+30 dBm MAX.
MAX.DC ±25V
?
INPUT / OUTPUT CONNECTORS
QUICK REFERENCE GUIDE
RF INPUT TERMINAL
RF input port.
- Maximum input: +30dBm (+20 dBm measurable)
- Input impedance: 50 W.
- Maximum DC voltage: ± 25 V.
- N-type: female.
RS-232 PORT
RS 232 9 PIN DSUB
For remote control.
DESCRIPTION DISPLAY
1
Ref: 20.0dBm
USB-B PORT
USB-B Device port.
For remote control.
Mkr 1 at
USB-A PORT
USB A port for saving/recalling settings/files to external memory.
Only supports FAT/FAT32 formatting.
1.0MHz
5.9
VGA PORT
Frequency
dBm
Center
1.0MHz
VGA video-out port. Supports SVGA
(640x480)
5 6
Start
500.0kHz
Stop
2
1.5MHz
7
Step
200.0kHz
3
Start: 500.0kHz RBW: 30kHz
Center: 1.0MHz
4
Reference Level
1
Trace and waveforms
2
Center: 1.0MHz
Span: 1.0MHz
trA
Stop: 1.5MHz
Sweep: 1.5sec
Marker information
5
Function menu
6
8
Frequency Bandwidth settings
3
Entry/Message area
4
Soft menu keys
7
Trace icons
8
Loading...
+ 5 hidden pages