Promax PROLITE-57 User Manual

Page 1
Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com
User's Guide to the PROLITE-57
PON Power Meter
v1.0 0 MI2029 (01/12/2014)
Page 2
2008-08-22 17:00:01
1310nm
1490nm
1550nm
ONU
OLT
VIDEO
1.2
4.5
-15.0
-
dBm
Pass
dBm
warning
dBm
Fail
mode
Threshold
dBm/dB
Time
REF/SEL
PROLITE-57
1. Introduction
1.1 Summary
PROLITE-
1550nm optical signal, but also accurately detect and measure the upstream burst at 1310nm sent from an ONU while the ONU is in the idle mode. The simple operation and accurate measurement make
PROLITE-
(suitable for APON, BPON, EPON and GPON application) installation/acceptance test to ensure that they meet required standards, and service activation and troubleshooting.
57
can measure not only 1490nm and
57
57
becomes an ideal tool for PON
1
Page 3
PROLITE-57
1.2 Main Function and Specifications
Cost efficient palm size designed for field and lab testing.
Support P/F measurement and normal measurement.
Easy-to-use interface with large color TFT display for easy visibility and LED indicators.
Simply connect-and-display the results of all three wavelengths (1310/1490/1550 nm) of PON
signals with two optical ports
Detect and measure the upstream burst at 1310 nm.
Support APON, BPON, EPON and GPON networks.
Pass, Fail and Warning indicators for easy view of signal condition.
User definable threshold value (up to 10 sets) Auto power shut off.
Low battery warningUSB interface.
Real-time clockUnit runs either by Ni-MH battery for more than 20 hours continuously work or
AC/DC adapter.
2
Page 4
1.3 Specification:
PROLITE-57
Connector Type
Detector type
Measurement Range
(Continuous Datastream)
Burst measurement range
(1310 nm bursted signal)
Spectral Passband
Insertion Loss
Accuracy
Linearity
Display
Refresh Rate of Display
Threshold
Auto Power-off
Number of Ports
Operating Temperature
Relative Humidity
Power Supply
Battery life
Dimension
Net Weight
SC/APC, ST/APC
InGaAs
1310 nm 1490 nm
-40 dBm~+10 dBm -40 dBm~+10 dBm -40 dBm~+20 dBm
-30 dBm~+10 dBm
1310 nm 1490 nm 1550 nm
1260 nm~1360 nm
10 sets(configured via PC-based software)
and one for 1490 nm / 1550 nm (OLT)
1.2V*4pcs Ni-MHAA;12V AC/DC Adapter
190 mm*105 mm*55 mm(L*W*H)
1480 nm~1550 nm
1.5 dB
±0.5 dB
±0.2 dB
2.8 inch TFT LCD
2.5 Hz
Yes
2 ports. One for 1310 nm (ONU)
-10 to +50° C
0%~95%,non-condensing
>20 hours
with rubber protector
700 g
1550 nm
1539 nm~1565 nm
3
Page 5
PROLITE-57
3 Safety Information
SAFETY RULES
The safety could not be assured if the instructions for use are not closely followed.
The external DC charger is a equipment, for safety reasons plug it to a
corresponding ground terminal
Use the mains adapter in and installations. To use
INDOOR
When using some of the following accessories use only the ones to ensure safety:
Observe all both of supply and measurement.
Use this instrument under the .
The user is not allowed to carry
Any change on the equipment must be carried out exclusively by technical staff.
Follow the described in the Maintenance paragraph.
.
Power adapter
specified ratings
cleaning instructions
Class II supply line with the
.
Overvoltage Category I Pollution Degree 1
specified
specified environmental conditions
out the following maintenance operations:
4
Page 6
PROLITE-57
Symbols related with safety:
DIRECT CURRENT
ALTERNATING CURRENT
DIRECT AND ALTERNATING
GROUND TERMINAL
PROTECTIVE CONDUCTOR
FRAME TERMINAL
EQUIPOTENTIALITY
ON (Supply)
OFF (Supply)
DOUBLE INSULATION (Class II protection)
CAUTION (Risk of electric shock)
CAUTION REFER TO MANUAL
FUSE
EQUIPMENT OR COMPONENT TO BE RECYCLED
Specific Precautions
Never look directly into optical outputs or a fiber while the equipment is on. Invisible laser beam may damage your eyes.
Descriptive Examples of Over-Voltage Categories
Cat I
Cat II
Cat III
Cat IV
Low voltage installations isolated from themains.
Portable domestic installations.
Fixed domestic installations.
Industrial installations.
Discharged batteries
1.- When the battery power is almost out, there will be a warning of indicator keeps blinking, then please replace the batteries or plug inAC adapter to charge batteries.
2.- Please make sure that you have turned the instrument on before charge the batteries, unplug the AC adapter when the batteries are fully charged.
3.- Please make sure the batteries are well placed before charge them.
4.- To eliminate the possibility of acid leakage, please take out the batteries if the unit will not be used for a long time
AC operation
If the instrument is mainly used at one location, e.g. in a laboratory or test department, the AC adapter can be used to power it instead of batteries. There is a DC input jack on the left side of the PL-57 instrument casing into which the output cable of the AC adapter is plugged. And when the AC adapter is plugged in, the AC Indicator on the LCD will be displayed.
Note:
1.- Power is supplied by the AC adapter even if battery is fitted. And the battery indicator is not displayed on the screen whenAC adapter is plugged.
2.- Make sure that the operating voltage of the AC Adapter / Charger is the same as the local AC line voltage.
5
Page 7
PROLITE-57
4. Preparing for Operation
Unpacking the instrument
Packing material
We suggest that you keep the original packing material. Using the original packing material is your guarantee of protecting the instrument during transit.
Checking the package contents
The standard accessories of are as follows:
Main unit Carrying Case CD(software) User's Guide 2 SC & ST adaptors 3 Ferrules USB-USB mini cable Case strap
Checking for damage in transit
After unpacking the instrument, check to see whether it was damaged in transit. This is particularly likely if the outer casing is clearly damaged. If there is damage, do not attempt to operate the instrument or to repair it without authorization. Doing so can cause further damage and you may lose your warranty qualification.
PROLITE-57
4*Ni-MH Batteries
AC Adapter
6
Page 8
2008-08-22 17:00:01
1310nm
1490nm
1550nm
ONU
OLT
VIDEO
1.2
4.5
-15.0
-
dBm
Pass
dBm
warning
dBm
Fail
mode
Threshold
dBm/dB
Time
REF/SEL
5. Operation
5.1 Layout
The front panel is divided in two parts:
– LCD Display
Part I
-
Part II Keypad
PROLITE-57
Video/OLTONU
Part 1
The tester shows test result on LCD screen, and in the meanwhile
indicates different status in part 2 by LED.
Tester connector types: SC/APC, ST/APC
Part 2
7
Page 9
5.2 Key’s Functions
P-ROLITE 57
Power Switch
down the key and release quickly (less than 2 seconds), the unit will switch to auto power off; if pressing down the key for longer than 2 seconds, the unit will shut down. If the unit is in threshold setup, time setup and backlit setup menu, the key becomes ESC key to exit the menu.
Mode Key
unit is in time setup, threshold setup and backlit menu, the key is used to increase value.
Threshold
menu. In threshold setup menu, press and release the key quickly (less than 2 seconds) to switch wavelength. In time setup menu, this key functions as <left> arrow key.
dBm/dB/Time
between dB and dBm; pressing the key down for more than 2 seconds enters to time setup menu. In time setup menu, threshold setup and backlit setup menu, the key is used to decrease value.
REF/SEL
the instrument will take current light intensity as reference to do measurement. If pressing and release the key quickly (less than 2 seconds), then the key will function as <right> arrow key.
– Press the key to Power On the unit. While the unit is in the state of power on, if pressing
– test mode. It is used to switch the test mode - P/F test mode and normal test mode. When the
– It is used to set threshold. Pressing it down for more than 2 seconds enters threshold setup
– unit switching key. Press and release the key quickly (less than 2 seconds) to switch unit
– It is used for reference value setup and selection. If pressing it down for more than 2 seconds,
8
Page 10
P-ROLITE 57
5.3 Definitions
LEDs
Not only the instrument will display measured optical power value on LCD screen, but also under P/F test
mode its three LED indicators will function with following meanings:
The three LED indicators represent upstream 1310 nm (ONU), downstream 1490 nm (OLT) and 1550 nm
(Video) respectively. The RED color indicates Fail, ORANGE color is Warning and GREEN color means
Pass.
Thresholds
The definitions for the three states (Fail, Warning and Pass) are described as below:
If assuming the instrument’s measuring upper limit as and lower limit as , the “Pass” threshold
value in instrument’s internal setup are , as Warning threshold and as
Fail threshold, . value represents
measured optical power, then:
P < Limit2 Low LED RED
1.If , means the power is , the will indicate in ;
Limit2 < P < Threshold3, Fail LED RED
2.If means , the will indicate in ;
Threshold3 < P < Threshold2 Warning LED ORANGE
3.If , means , the will indicate in ;
Threshold2 < P < Threshold1 Pass LED GREEN
4.If , means , the will indicate in ;
Threshold1 < P < Limit1 Fail LED RED
5.If , means , the will indicate in ;
P > Limit1 LED RED
6.If , means the power is High, the will indicate in .
also Limit2 < Threshold3 < Threshold2 < Threshold1 < Limit1 P
Threshold1 Threshold2 Threshold3
Limit1 Limit2
9
Page 11
P-ROLITE 57
5.4 Quick Operation
Connect the instrument to the optical link under test.
1.
Press Power On key to turn on the instrument.
2.
Pressing down key and key at same time enters to Backlit setup menu. Using ▲ and
3. Threshold REF/SEL
▼ keys to adjust backlit to a suitable brightness then press Power key again to save the backlit setup and exit
Backlit setup menu.
4. Time REF/SEL
Pressing key for more than 2 seconds enters to time setup menu. Using ▲ ▼ ◄, ► and
keys to setup time. After the setup, press Power key (less than 2 sec) to save the setting and exit.
5. Threshold
Pressing key for more than 2 seconds enters to threshold setup menu. Select one group of
threshold from the preset list and press Power key (less than 2 sec) to exit.
6. Mode
Press key to select a test mode, and then the instrument will execute the test automatically and
display the test results on the LCD screen.
7. test
Power Off. After completing the , pressing Power key for more than 2 seconds to shut down the
instrument.
,,
10
Page 12
P-ROLITE 57
5.5 Detail Operation
5.5.1 Powering On the Instrument
Press the Power key to turn on the instrument. It will automatically go to test menu. In test menu,
press Power key and release quickly (less than 2 seconds) to activate or deactivate Auto shut
down function. The auto shut down function means the instrument will shut down automatically if
the instrument has not been operated for a certain period of time. The time period can be set. The
default is 10 min.
11
Page 13
5.5.2 Test mode switch:
P-ROLITE 57
In the test menu, press to switch between normal test mode and P/F test
Mode
mode.
1. Normal test mode
Normal test mode means do not setup threshold value but display optical power directly. In this mode, the LED indicators will not light. The results are displayed in two units: dB and dBm using dB/dBm key to switch. See Fig. 1.
Unit dBm is to display the actual power Unit dB is to display a power value relative to reference value. In this mode, reference value needs to be preset correctly.
2. P/F test mode
P/F test mode means the measured light power comparing to preset threshold value to determine if the measured light power meets user’s requirement or not. LCD will display the optical power and current state. The LED indicators below the LCD display will also change color to match the current state of measured light. This test mode is very useful in some special cases required. See Fig. 2.
12
Auto off
Fig.1 Normal Test Mode Menu (dB)
Auto off
Fig.2 P/F Test Mode Menu
Page 14
5.5.3 Threshold Setup
The user can setup the value. The steps are as following:
In the test menu, pressing key for more than 2 seconds enters to
threshold setup menu – see Fig. 3
In this menu, left side displays wavelength and right side displays threshold value. Top line indicates system information (date & time) and bottom line indicates the information of threshold including threshold symbol, threshold number and name. In this menu, press and release key quickly (less than 2 seconds) to switch the wavelength among 1310 nm, 1490 nm and 1550 nm. Press ▲ ( ) key to view previous record, ▼ ( ) key to view next record, key to validate the current threshold value. After above operation, all P/F mode test results will base on this threshold value.
Note: The threshold value can only be preset by PC software. See PC software section for detail.
After finishing the setup, press Power key (less than 2 sec) to exit the setup
menu.
Mode dBm/dB
REF/SEL
Threshold
Threshold
P-ROLITE 57
USING
Threshold 01 Telecom
Threshold Setup MenuFig.3
13
Page 15
5.5.4 Time Setup
P-ROLITE 57
Pressing key for more than 2 seconds enters to time setup menu, see Fig. 4.
In the time setup menu, the key becomes <left> arrow key and key becomes
Time
Time Setup
08-10-25 15:02:03
Yes
Fig.4 Time Setu p Me nu
Threshold REF/SEL
<right> arrow key - using them to move cursor. When cursor moves to a number, the user can use ▲
Mode dBm/dB
( ) key to increase value and ▼ ( ) to decrease value. When cursor moves to “Yes” and
REF/SEL
press key for more than 2 seconds, the “Yes” will flash, means the instrument accepts the time change. During the time setup, the user can press Power key (less than 2 sec) to exit time menu and back to test menu, then the system time setup remains unchanged.
14
Page 16
P-ROLITE 57
5.5.5 Unit Switch
When the instrument is in normal test mode, pressing dBm/dB can switch unit between dBm and dB. Here, the unit dBm is the actual power and unit dB is a power value relative to reference value. Refer to next section about “Reference value setup”.
When the instrument is in the P/F test mode, pressing dBm/dB key will automatically exit P/F test mode and switch to normal test mode. Its unit will be in dB.
15
Page 17
5.5.6 Reference Value Setup
P-ROLITE 57
In the test menu, press key for more than 2 seconds, then the LCD will display in red (see
REF/SEL REF
Fig. 5). This means the instrument choose the current light power as reference value. The test results afterward are the values after comparing to this reference value. Now, the unit will be in dB and LED below LCD display will not light.
REF
Auto off
Fig.5 REF Value Setup Menu
In the test menu, press and release key quickly (less than 2 seconds), then current reference
value will appear on LCD display. See Fig. 6.
REF/SEL
View REF Value MenuFig.6
16
dBm Ref
dBm Ref
dBm Ref
Auto off
Page 18
5.5.7 Backlit Setup
P-ROLITE 57
Pressing and keys at same time enters to backlit setup menu. See Fig. 7.
In this menu, press ▲ ( ) key to brighten the backlit and ▼ ( ) key to weaken the backlit. After completing the setup, press Power key (less than 2 sec) to save the setting, exit and back to the test menu.
Threshold REF/SEL
Backlit Setup MenuFig.7
Mode dBm/dB
17
Page 19
5.5.8 Description of Memory Record Function
P-ROLITE 57
Description of Interface:
At the main interface, it shows the current recording number on the left bottom of the page:
Displaying
: num : xxxx(xxxx means the current recording number, the
maximum number up to 1000 pieces ).
As you may refer to the picture 8,it means there are 24 pieces of test recording
inside.
Press the button for longer than 3 seconds to save the current testing
"mode"
value, as you may refer to the picture 9, the recording number automatically adds 1 when the interfaces shows "Save".
18
num:0024
Low
Low
Low
Fig.8
SAVE
Fig.9
m
m
m
Auto off
Page 20
P-ROLITE 57
At the " " interface(refer to picture 10), the characters on top of horizon line are "total number of recording" and "wavelength"(from left to right). The characters under horizon line are "the number of recording" and the optical power value in accordance to the corresponding wavelengths
record view
3
low
1:
low
2:
low
3:
low low low
low low low
1550
1490
1310
On the bottom of the page you may see the main menu
RST
X
Esc
Description of button
Simultaneously press to enter the "record view" interface,press the " "
"Mode" "Threshold"and
Fig.10
shortly to exit it, refer to picture 10 for this interface.
At the "record view" interface,you may see the main menu on the bottom of the page,they are (from left to right):
ESC X RS T
There is an underline when you selected the menu ( the "ESC" has been chosen in picture 10),press " " shortly to move the underline from left to right , after the underline moved to your ideal
Threshold
menu,press " " shortly to execute it.
REF/SEL
19
Page 21
P-ROLITE 57
Description of every individual menu:
: Page up to the last 10 recording : Page down to the next 10 recording : Page up to the last 100 recording : Page down to the next 100 recording : Exit the "record view" interface ( same as press " ")
ESC
: Select one or more than one recording to delete
X
: Reset the recording memory,this operation is not reversible and it'll take 5 seconds to complete
RST
with power supply can not be disconnected,otherwise it may damage the chip of tester.
At the "record view" interface,press " " button to move "X" upward one step,press " "
mode dBm/dB
button to move "X" downward one step. In picture 10,the interfaces explains that there are totally 3 testing result inside," " means the saving power value is lower than the value from threshold setting.In picture 11, " " means the saving power value is higher
low
high
than the value from threshold setting. The digital means the power value of corresponding wavelength.
25 13: 14: 15: 16: 17: 18: 19: 20:
high high high high high high high high
Esc
1490 high high high high high high high high
X
1310
Fig.11
20
1550 high high high high high high high high
RST
Page 22
PROLITE-57
6. Remarks
1.
When battery power is not enough, the battery indicator will flash. Please immediately use the
attached AC/DC adapter or charge the instrument/battery.
2.
While charging, the instrument does not allow the user to power off. If pressing Power Off key, the
charger head will flash. After the battery gauge shows “full”, means the battery is fully charged,
remove the charger.
3.
Before charging the instrument, please make sure the rechargeable battery pack is installed.
4.
If do not use the instrument for long time, please remove the battery pack to avoid battery
descompotion.
5.
Due to existence of strong interference in some working environment, sometime short lines or
disorder may appear on LCD screen, this is normal and not going to affect the instrument. The
display will back to normal if reboot the unit or switch menu to refresh the display.
21
Page 23
PROLITE-57
7. Advice:
Please use the dust-proof cap to secure the connector to be scratched or contaminated everytime
1)
when the product is not in operation.
Please always stay the optical connectors away from oil, dirt and other contamination to ensure
2)
the proper operation,
3)
Always be careful when you are intend to plug in and pull out the connectors because optical
interface is extremely sensitive.
22