Promax PROLITE-55 User Manual

Page 1
User's Guide to the PROLITE-55
Three-wavelength Laser Source
99 Washington Street Melrose, MA 02176 Phone 781-665-1400
v1.0 0 MI2028 (01/12/2014)
Visit us at www.TestEquipmentDepot.com
Toll Free 1-800-517-8431
Page 2
1 Introduction
ROLITE-55
P
nm
1310
270Hz
1kHz
2kHz
8.8.8.8
SINGLE TWIN
ON
OFF
AUTO-OFF
TWIN
CW/Hz
The three-wavelength laser
PROLITE-
55
source offers excellent stability, portability and facile adjustments for accurate optical fiber testing. Single output connector serves three wavelengths, 1310nm,1490nm & 1550nm.
PROLITE- can be used to test single mode
55
optical fiber of long distance and local network. Also it can work with optical power meter to measure the loss of optical fiber.
Page 3
PROLITE-55
2 Safety Information
SAFETY RULES
The safety could not be assured if the instructions for use are not closely followed.
The external DC charger is a equipment, for safety reasons plug it to a
corresponding ground terminal
Use the mains adapter in and installations. To use
INDOOR
When using some of the following accessories use only the ones to ensure safety:
Observe all both of supply and measurement.
Use this instrument under the .
The user is not allowed to carry
Follow the described in the Maintenance paragraph.
.
Power adapter
.
specified ratings
Any change onthe equipment mustbe carried outexclusively by technicalstaff.
cleaning instructions
Class II supply line with the
.
Overvoltage Category I Pollution Degree 1
specified
specified environmental conditions
out the following maintenance operations:
Page 4
PROLITE-55
Symbols related with safety:
DIRECT CURRENT
ALTERNATING CURRENT
DIRECT AND ALTERNATING
GROUND TERMINAL
PROTECTIVE CONDUCTOR
FRAME TERMINAL
EQUIPOTENTIALITY
ON (Supply)
OFF (Supply)
DOUBLE INSULATION (Class II protection)
CAUTION (Risk of electric shock)
CAUTION REFER TO MANUAL
FUSE
EQUIPMENT OR COMPONENT TO BE RECYCLED
Specific Precautions for PROLITE-55
CLA SS 1
LASER PRODUCT
Never look directly into optical outputs or a fiber while the equipment is on. Invisible laser beam may damage your eyes.
The use of devices that are not specified by this manual and the internal manipulation of the instrument may cause harmful radiation.
Use the laser source output with caution.
Keep closed the cover of this output when not using it.
The laser source output emits light at 1310 nm, 1490 nm and 1550 nm wavelength and 0 dBm power.
Descriptive Examples of Over-Voltage Categories
Cat I
Cat II
Cat III
Cat IV
Low voltage installations isolated from themains.
Portable domestic installations.
Fixed domestic installations.
Industrial installations.
Page 5
ROLITE-55
P
3 Preparing for Operation
3.1 Unpacking the instrument
Packing material
We suggest that you keep the original packing material. Using the original packing material is your guarantee of protecting the instrument during transit.
Checking the package contents
The standard accessories of are as follows:PROLITE-55
Main unit DC 6V Adapter 2 rechargeables AA batteries
Checking for damage in transit
After unpacking the instrument, check to see whether it was damaged in transit. This is particularly likely if the outer casing is clearly damaged. If there is damage, do not attempt to operate the instrument or to repair it without authorization. Doing so can cause further damage and you may lose your warranty qualification.
Carrying Case
User's Guide Connectors(SC/APC,ST/APC) 3 ferrules
Page 6
P
ROLITE-55
3.2 Power Supply
There are battery indicator and power plug on the screen to show the power supply. When you use the DC 6v charger, there is no battery indicator on the screen. When you do not connect the DC 6v charger, the adapter indicator will disappear on the screen.
nm
18 88
When you use the battery, the battery indicator on the screen will show the remaining charge. An empty battery indicator means the power is almost out. When the battery charge is extremely low to supply the necessary power, the instrument will automatically switch off after several beeps of the buzzer. Please change the battery or recharge it
nm
18 88
18 88
18 88
nm
nm
Page 7
4 Operation
FHS2T01F
LASER SOURCE
>2s PERM
FH
TWIN
CW/Hz
ON
OFF
FHS2T01F
LASER SOURCE
>2s PERM
TWIN
CW/Hz
ON
OFF
TWIN
CW/Hz
ON
OFF
4.1 Display and controls
4.1.1 Front(Panel Board)
ROLITE-55
P
1
2
3
4
5
KeyNo.
CW/Hz
TWIN
>2s PERM
ON
OFF
Function
Wavelength Shifting Key: Switches working wavelength between 1310nm,1490nm and 1550nm.
Modulated Wavelength Shifting Key: Switches modulated wavelength and continuous wavelength.
SINGLE: Auto-wavelength recognition is off. TWIN: Auto-wavelength recognition is on.
Switches backlighting on/off.
Switches Instrument on/off. Long keypress while powering on to activate the instrument without Auto-off function.
Page 8
4.1.2 Back & top
P
Connector
Battary Plate (including 2 units of AA batteries)rechargeables
ROLITE-55
DC 6v power input
Page 9
4.1.3 LCD
18 88
nm
date
P
Wavelength
DC Adapter
Battery Charge
Modulation
ROLITE-55
270Hz
1kHz
2kHz
SINGLE TWIN
8.8.8.8
AUTO-OFF
Power
Measurement Unit(dBm)
Auto-wavelength Recognition
Auto-off
Page 10
4.2 Turning the instrument on and off
ROLITE-55
P
>2s PERM
ON
OFF
Press the “ON/OFF” key briefly. The instrument powers on.(See the figure) Press the “ON/OFF” key briefly again. The instrument powers off.
Note:
1 The instrument powers off automatically if no key press in 10 minutes. 2 Press the “ON/OFF” key for about 2 seconds to power on the instrument with
Auto-off function
1310
SINGLE
nm
-5.0
AUTO-OFF
Page 11
4.3 Switching the wavelength
1550
1490
1310
nm
ROLITE-55
P
Press the “ Key to switch the wavelength between 1310nm,1490nm and 1550nm.
λ”
10
SINGLE
-5.0
AUTO-OFF
Page 12
4.4 Frequency Output
CW/Hz
2kHz
1310
1
CW
nm
P
ROLITE-55
The instrument defaults to CW when it switch on. When it is set to CW, there is no frequency on display. Press the " " Key to select the
CW/Hz
output among 270Hz, 1kHz and 2kHz.
11
1kHz
270Hz
-5.0
SINGLE
1."CW" is not displayed on the LCD
AUTO-OFF
Page 13
ROLITE-55
P
4.5 Auto-wavelength Recognition
TWIN
Press the "TWIN" Key to tun on and off the auto-wavelength recognition function.
:
Note
It is suggested to turn off the "TWIN" code when you do not use it. The optical power output of
1)
laser source will be fluctuated.
2)
The function of "TWIN" and Modulation cannot work together. When the "TWIN" is on, modulation
of laser source module is closed automatically.
3)
Wavelength will be shifted automatically according to the recognition when the "TWIN" of power meter module is on. In another word, the modulated signal of 270Hz, 1kHz and 2kHz cannot be recognized and received at the moment.
12
Page 14
4.6 Switching backlighting of the LCD on and off
Press the Key to switch the backlighting of the LCD on and off.backlighting
P
ROLITE-55
1310
SINGLE
nm
-5.0
AUTO-OFF
13
1310
SINGLE
nm
-5.0
AUTO-OFF
Page 15
P
ROLITE-55
4.7 Connecting with Optical Power Meter
It can work with optical power meter to measure the loss of optical fiber accurately.
nm
1310
270Hz
1kHz
2kHz
8.8.8.8
SINGLE TWIN
AUTO-OFF
nm
ON
TWIN
OFF
CW/Hz
1888
REF
270Hz
1kHz
2kHz
8.8.8.8
AUTO-OFF
14
Page 16
5 Specifications
Optical Specifications
Model PROLITE-55
PROLITE-55
Laser
Spectral Width
Stability (15 min preheat @ 25 C)
CW output power
Modulated Wavelength
Available Connector
Power
°
Class I
3 nm typical value
± 0.05 dB/15 min ±0.1 dB/5 h to 1310 nm ± 0.1 dB/15 min ± 0.2 dB/5 h 1490 nm ± 0.05 dB/15 min ± 0.1 dB/5 h 1550 nm
-5.0 dBm 1 dB±
270 Hz, 1 kHz, 2 kHz
SC/APC,ST/APC interchangeable connectors.
2 units of AA batteries
rechargeables
to
to
15
Page 17
General Specifications
ROLITE-55
P
Operation Temperature
Storage Temperature
Humidity
Size(H×W×D)
Weight
-10 °C ~ +50 °C
-20 °C ~ +70 °C
<90%
160 mm × 76 mm × 45 mm
0.26 kg (including batteries)
16
Page 18
6 Maintenance
Please disconnect the DC adapter/charger and cover the protective dust cap once you finish using. It is a good idea to clean the connector and the instrument when they get dirty through use. Optical cleaning pads and anhydrous alcohol is recommended. And please be careful not to get the detergent inside the instrument.
ROLITE-55
P
17
Page 19
PROMAX ELECTRONICA, S. L.
99 Washington Street Melrose, MA 02176
Phone 781-665-1400 Toll Free 1-800-517-8431
Visit us at www.TestEquipmentDepot.com