Promatic Security Systems PDS8830 8820 User Manual

Hongkong Promatic Group
EAS Mono System Manual
Version: V1.0
Date: June 25, 2007
EAS Mono System Manual
Catalog
1.System Features--------------------------------------------------------------------------2
2.Interface Explanation
----------------------------------------------------------------3
3.System Installation--------------------------------------------------------------------4
4.System Adjustment--------------------------------------------------------------------5
1Http://www.promaticgroup.com
1
EAS Mono System Manual
1. System Features
EAS Mono System is a kind of EAS Sensor which integrates with the
Transmitter and the Receiver. The brand new Mono system technology
has already lead the EAS RF system to a mature time. Compared with the
original EAS system, the Mono system is excellent with its fashionable
configuration ,high performance and convenient installation.
Pic1:2 access with original EAS system
Pic2:2 access with Mono system
2Http://www.promaticgroup.com
2
EAS Mono System Manual
p
put
2. Interface Explanation
JP4 RS232 interface
P1 power in
ut
P2 power out
8 Indicate LED: DS1 ~DS8
Pic3:Main board interface sketch map
P7 buzzer interface;P8 alarm light interface
P5relay output interface
P4Syn output interface
P3Syn input interface
P10 TX/RX interface
P11 TX/RX interface
TX GND
RX
+
­+
-
Pic4:Main board interface sketch map
RX/TX
RX/TX
DNG
RX/TX
RX/TX
DNG
+ -
+ -
GND
Relay output
GND
GND
Syn output
Syn input
DNG
3Http://www.promaticgroup.com
3
EAS Mono System Manual
DS1~DS8 explanation
1)DS1: indicate alarm status,flashing when detect the tag/label signal
2)DS2~DS4,for indicating noise level of the system working circumstance. DS2~DS4 three LED all go out:little noise DS2 lighting:Low level of noise DS2 &DS3 lighting:Medium level of noise DS2&DS3&DS4 all lighting:High level of noise. When in normal status,through adjusting the VR1 to get the DS2 lighting,and the DS3 flashing.
3)DS5 (null)
4)DS6&DS7:indicate system working status DS6&DS7 go out:Working as a master status; DS6 goes out and DS7 is lighting:Working as a slave status; DS6&DS7 lighting:Function closed.
5)DS8:indicate program running,lighting when in normal status.
3.System Installation
1)System Synchronization Installation When need to install more than one Mono sensor in a project,synchronization connection is necessary.And the syn cable use resistance 100 Ω twisted-pair cable, synchronized connection way refer to Picture 4. From master signal output to slaver signal input, if you want to install one more, connect the syn cable from the slalver signal output to other slaver signal input.
2)Cable laying and connection
Keep the Mono system away from these cables:network reticle;power cable(>110VAC).The syn cable can not be crossed with other cables,else cover the syn cable with the metallic pipe.
The Mono system adopt the appropriative power supply,can not share
power supply with computer,display or other electricity equipment
4Http://www.promaticgroup.com
4
EAS Mono System Manual
Due to the Mono system has double side detection effect,,articles with label must be placed at the distance of more than 1.5m.
Keep the Switching Power Supply away from the Mono system.(at least 2m away)
The system power cable must adopt 1.5mm
2
twisted-pair shield cable.
4. System Adjustment
After installation,each Mono sensor need adjustment through communication interface with computer .Normally adopt the RS23 2 communication interface.
1)Connection between the PC and the sensor PCB
Pic6: Connection Sketch Map
Adopt the standard COM port communication cable,connect one side of the cable with the PC RS232 interface,and connect the other side of the cable with the sensor PCB JP4(R S232 interface). Pl ease connect Tx&R x cable and ground cable in corret way. After conenction ,if can not open the communication connection,please exchange the TX&RX cable (at the JP4)position and check again.
2)Adjustment software explanation
After correct connection as the instruction above,run the ‘Mono system adjustment’ program:
5Http://www.promaticgroup.com
5
EAS Mono System Manual
Operation Step:
(1)Build the connection:select the corresponding ‘Com’ port and press the ‘Open’ button,’Address’ set to :255 (default). (2)’Master/Slaver’:Select the ‘Master’,and press the ‘Set’ button.This ‘Master/Slaver’ funtion has 3 options,each means:
z ‘Close’---- DS6&DS7 both lighting,system is off working status z ‘Slaver’----only DS7 lighting,need synchronization signal input z ‘Master’----DS6&DS7 both no lighting,system work in normal status.
(3)’Period’:3 options:’20/40/60’;or can input a value in the range:14~20(propositional,the default value is 16) (4)’Gain’:the default value is 1;propositional value:1~5 (5)’Pulse’:the default value is 3(refer to the circustance condition);normally input 3 or 4 (6)’Alarm Threshold’:the default value is 1,input range:1~3(refer to the circustance condition) (7)’Label speed’:the default value is 1,input range:1~5(refer to the circumstance condition)
6Http://www.promaticgroup.com
6
EAS Mono System Manual
(the item3 to item7 above:refer to the circumstance condition to set)
3)Each parameter explanation
Period----valid data period;(Period
detecting speed
Gain----means the gain between the label signal and the noise signal(Gain
1~5.
Pulse----means the valid signal quantity(Pulse
Range
Alarm Threshold----means the system alarm start-up value(Alarm Threshold
),standard value is 3~4.
),standard value range is 14~20.
Æ False AlarmÆ Detecting Range),standard value range is
Æ False AlarmÆ Detecting Range↓)
ÆSystem detecting precisionÆSystem
Æ False AlarmÆ Detecting
Label Speed----means the label signal level when the label passing through the system detecting range.(Label Speed
Range
Master/Slaver----set the system working status. Now it has system turn off, master and slaver three kinds of setting status.
), standard value1-5.
ÆFalse AlarmÆDetecting
7Http://www.promaticgroup.com
7
EAS Mono System Manual
FCC Warning:
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Changes or modifications to this unit not expressly approved by the party responsible for compliance will void the user’s authority to operate the equipment. Any change to the equipment will void FCC grant.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
--Reorient or relocate the receiving antenna.
--Increase the separation between the equipment and receiver.
--Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
--Consult the dealer or an experienced radio/TV technician for help.
The equipment compliance with FCC radiation exposure limit set forth for uncontrolled Environment
8Http://www.promaticgroup.com
8
Loading...