This equipment has been tested and found to comply with the limits for a
Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause harmful
interference to radio communication.
Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the interference
at his own expense.
Information
USB-232 Converter
MACHINE TYPE
USB-232
FUNCTION
USB Ver 1.1
LED
STATUS
Multiple Port
RS232
USB-422/485 Converter
MACHINE TYPE
USB Ver 1.1
LED
STATUS
USB-422/485
FUNCTION
Multiple Port
RS-422/485
- 1 -
Standard Package
Main Unit
( USB232/422/485-00 )
Driver Disk
( DISK5088 )
USB232/422/485 22/4
User's Manual
( TM951006 )
USB Cable
( WAS-1487 )
- 2 -
Installation
Driver Software Installation -
1.Connect USB232/422/485 converter into the USB PORT of
your Computer first.
2.Under Windows 98/2000/Me/XP,put DISK5088 into the
floppy disk driver,it will automatically install the USB232/422/485
Driver Software into your Computer by following the steps as
below:
1. This wizard searches for new drivers for USB Device
Click Next
2. What do you want Windows to do ?
Select this
Click Next
- 3 -
3. Select Searching locations for new driver
Give the path
location
Select this
Click Next
4. Windows is now ready to install the best driver
Device name
Path location
Click Next
- 4 -
5. Windows is installing the best driver now
6. Windows has finished installing the software
Finish driver software
installation
Click Finish
- 5 -
7. Make sure if the driver software installation is finished
Connect USB232/422/485 unit into the USB port of the computer and then
Click " Start " ->" Settings " -> " Control Panel " -> " System " ->" Device
Manager " to see if there are " PROMAG USB232/422/485(COM3)" at Ports
(COM & LPT) and "PROMAG USB232/422/485 "at Universal Serial Bus
controllers.
USB232/422/485
connected at COM3
USB232/422/485
is here
- 6 -
Remove Driver Software
How to remove USB232/422/485 Driver Software
from your computer-
Put DISK5088 into the floppy disk drive of the computer and then
find and execute Uninstall.EXE by following the steps as below:
1. Execute Uninstall.EXE program
Execute
Uninstall.EXE
program
2. Confirm to execute Remove program
Click
Here
- 7 -
3. Re-boot the Computer after remove program is done
Click Yes
Remove completed
or click "No" button for show as below :
- 8 -
Technical And Operational Description
Front Panel of USB232-00
LINK
USB Port
Front Panel of USB422/485-00
TX
RX
RS232 Port
LINK
USB Port
TX
Remark: One USB485 converter
can be used for connecting two
units of RS-485 devices.
RS422/485
Port
RS-422
RX
Or
RS-485
- 9 -
Operation of USB232/422/485 Converters
RS232/422/485 connector
Connecting with the terminal device,which is e quipped with
RS232/422/485 interface.
USB connector
Connecting with the Computer USB port or Hub.
LINK
LINK LED turns on when the USB232/422/485 unit is ready
for use.
TX
TX LED turns on when the data is
sending from USB port to RS232/422/485 device.
RX
RX LED turns on when the data is
sending from RS232/422/485 device to USB port .
RS232 PIN FUNCTION
9
1
RS422
PIN No.I/ODESCRIPTION
PIN
TX
RX
1
2
3
4
5
6
7
8
9
+
+
I
I
O
O
X
I
O
I
I
-
-
Data Carrier Detect
Received Data
Transmitted Data
Data Tirminal Ready
Signal Ground
Data carrier
Request To Send
Clear To Ssend
Positive dc TEST
DESCRIPTION
RS422 TX -
RS422 TX +
RS422 RX -
RS422 RX +
RS485
PIN
1
2
- 10 -
+
+
DESCRIPTION
-
-
RS485 -
RS485 +
RS485 -
RS485 +
Connection
1. Communication between TR550 RS-232
Device and USB Port
WAS-1436WAS-1487
USB PC
USB232TR550
2. Communication between TR510 RS-232
Device and USB Prot
WAS-1392WAS-1487
USB PCUSB232TR510
3. Communication between AC9400 RS-232
Device and USB Port
WAS-1436WAS-1487
USB PCUSB232AC9400
4. Communication between RS-232
MODEM and USB Port
MODEM
USB PC
WAS-1487
USB232
ACCESSORY
RS232
MODEM
- 11 -
TEL
LINE
5. Communication between TR550 RS-485
Device and USB Port
WAS-1467WAS-1487
USB PC
USB485TR550
6. Communication between TR510 RS-485
Device and USB Prot
WAS-1392WAS-1487
USB PCUSB485TR510
7. Communication between AC9400 RS-485
Device and USB Port
WAS-1467WAS-1487
USB PCUSB485AC9400
8. Communication between TR530 RS-422
Device and USB Port
WAS-1467WAS-1487
USB PCUSB422TR530
- 12 -
If you are using RS485 interface,you have to add 1 pcs
120 Ohm terminal resister on the last unit of machine.
See the figure below:
RS485:
WAS-1487
USB PC
WAS-1467
AC-9400
last unit
RS422:
USB PC
120 Ohm
WAS-1487
RS485 +
RS485 -
TX+
AC-9400AC-9400
WAS-1467
TR530
AC-9400
last unit
120 Ohm
TX-
RX+
RX-
- 13 -
TR530TR530
9. Wire connection between RS485 Device
and USB485 Converter
USB485
PIN
1
2
1
2
+
-
+
-
USB485
PIN
+
-
+
-
FUNCTION
RS485+
RS485-
RS485+
RS485-
FUNCTION
RS485+
RS485-
RS485+
RS485-
WIRE
CUT*
CUT*
CUT*
CUT*
5
CUT*
7
WIRE
CUT*
CUT*
CUT*
4
CUT*
6
WAS-1467
COLOR
GRAY
ORANGE
BLACK
RED
GREEN
YELLOW
BLUE
WAS-1392
COLOR
BLUE
BROWN
RED
ORANGE
YELLOW
GREEN
PLUG
1
2
3
4
5
6
7
8BROWNCUT*
PLUG
1
2
3
4
5
6
10. Wire connection between RS422 Device
and USB422 Converter
TX
RX
PIN
USB422
+
-
+
-
FUNCTION
T+
T-
R+
R-
WIRE
1
CUT*
3
CUT*
5
CUT*
7
WAS-1467
COLOR
GRAY
ORANGE
BLACK
RED
GREEN
YELLOW
BLUE
- 14 -
PLUG
1
2
3
4
5
6
7
8BROWNCUT*
Specifications
USB
RS232
RS-422/485
USB Interface:
Full compliance with the USB Specification V 1.1
RS232 Interface :
RS232 , Full , 8N1 , max 120K bps, 10KV ESD
RS422/485
Interface :
RS422/485 , Full , 8N1 , max 250K bps, 10KV
ESD
Mounting :
Any surface
±
±
Dimensions :
USB232: D 18.8 x W 35 x H 56 mm
USB422/485: D 18.8 x W 35 x H 63 mm
%
C/F
Environment :
Operating Temp : 0 ~ 55 Deg.C
Storage Temp : -10 ~ 55 Deg.C
Humidity : 10 ~ 90 % relative
- 15 -
Note
1.#Do not disconnect the USB-xxx converter during running
your application program to avoid any unexpected problem.
2. USB-xxx Driver software provides maximum 8 pcs of
USB-xxx converters to be used for multiple device
communication.The addresses of the multiple devices
are according to the COM PORT addresses of the PC or
the addresses of the HUB USB PORT where the devices
are connected.You should insert the USBxxx into the
COM PORT or HUB PORT one by one in order with the
addresses indicated.
3. USB-xxx does not work with DOS.Only Win98/2000/Me/
XP
support USB.
4. You must connect USB-xxx Converter into the USB port
of your computer before you start USB-xxx Driver
software installation.
5. After USB-xxx Converter is connected into USB port of
the computer which is with USB-xxx Driver software
installed,LINK LED will turn on to be ready for use,
otherwise unplug USBxxx converter and try again after
5 seconds or longer.
6. After unplug USB-xxx converter from the computer,you
must wait for minimum 5 seconds and then plug
USB-xxx converter into the computer again,otherwise
Windows may not detect USB-xxx converter.
7. In the Application Software, the handshaking property
must be set to "None" when you use USB485.
8.If you are using RS485 interface for long distance
transmission,we suggest you use a 24AWG or begger
range one shielded cable for connection,in order to have
better performance.
- 16 -
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.