PROLiNK LCD User Manual

IPS Series
LCD Inverter Series
Inverter UPS
The PROLiNK IPS LCD Series is a compact inverter system that delivers high efficiency conversion from DC to AC power.
This environmentally friendly and economically sound power backup system provides clean and stable power for home
appliances and electronic devices. With a built-in 20Amp DC charger current, this unit is able to charge VRLA batteries of up to 200Ah. In addition, the PROLiNK IPS LCD series also comes with a universal socket outlet for convenience.
• Simulated sine wave inverter
• 10 A or 20 A charging current
• Auto restart while AC is recovering
• Overload and short circuit protection
• Generators & Computer-related devices compatible
• Cold start function
Rear Panel
For 1200VA to 5000VA model
1. Battery Connector
2. Input Protector
3. AC Input
4. Inverter Output
5. Narrow/ Wide Selector (only available for
IPS1200 and IPS2400)
6. 10Amp/20Amp Charging Current Selector (only available for IPS1200 and IPS2400)
5 6
1
2
3
4
3
2
IPS1200/ IP2400
1
4
2
3 4
1
IPS3000
IPS5000
Full Specifications
Inverter UPS
MODELS
Capacity
INPUT
Nominal Voltage
Voltage Range
OUTPUT
Output Voltage Regulation (Battery Mode)
Frequency
Frequency Regulation (Battery Mode)
Transfer Time
Waveform
BATTERY
DC Voltage Overcharge Protec 30V 60V15V
INDICATION
LED Display
LCD Display
Alarm
Sounding
EFFICIENCY
AC to AC >95% DC to AC >80%
PHYSICAL
Dimension (mm) D x W × H Net Weight (kgs)
ENVIRONMENT
Humidity Noise Level
VA Watt
Narrow Range Wide Range
IPS1200
1200
Simulated Sinewave Pure Sine Wave
10Amp / 20Amp (selectable) 20AmpCharging Current
AC Mode - Green
Battery Mode - Yellow
Low Battery – Yellow flashing
Shutdown Mode – Yellow flashing
Charging Mode - Green flashing Charging Mode - Green flashing
Overload - Red flashing
Input Voltage, Output Voltage,
Load level, Battery level, Fault alarm
Overload - Sounding every 0.5 seconds
Low Battery - Sounding every 2 seconds
Overcharging Fault – Continuously sounding
Less than 50dBA Less than 60dBA
IPS2400
2400
220/ 230/ 240VAC
10ms Typical, 20ms (max)
0~90% Relative Humidity. 0~40°C
90 - 280VAC
230VACNominal Voltage
±10%
50Hz or 60Hz
±1Hz
24V 48V12V
IPS3000 IPS5000
3000
170 - 280VAC162 - 290VAC
N/A
AC Mode, Inverter Mode,
Charger Mode, Load Level, Fault
Overload - Sounding every 0.5 seconds
Low Battery - Sounding every 2 seconds
High DC Voltage - Continuously sounding
Fan fault – Sounding 2 time every 2 second
5000 4200720 1440 2500
407 x 350 x 110268 x 330 x 76293 x 231.5 x 82.5
9.02.55 4.92.35
All specifications, designs and contents are subjected to changes without prior notice.