PROLiNK EnerHome PRO PRO700 Instruction Manual

Blk 16 Kallang Place #06-02
Singapore 339156
1. CAUTION English
The UPS battery has been fully charged before leaving our factory. During the shipment, some level of power may have been discharged. In order to ensure the e fficiency of the U PS, please allow the UPS to charge its battery for at least 12 hours before use.
Connect the UPS to a two-pole, three-wire groun ding mains (AC). The AC source must be connected to appropriate branch protection (fuse or circuit breaker). Conne ction to any other type of AC source may result in a shock hazard and may violate your warrant y claim.
This UPS has an internal battery and its energy can n ot be de-energized by the user. The output may be energized even though when the UPS is not connected to the main AC.
DO NOT install the UPS in locations where there is water or excessive humidity. DO NOT allow water or any foreign object to enter the UPS or put an y objects containing
liquid on or near the UPS. DO NOT remove the cover. No user serviceable parts. Refer servicing to qualified service
personnel. DO NOT connect any non-computer peripherals to the UPS. The UPS is designed for use
with computer loads only. To reduce the risk of overheating the UPS, avoid exposi ng the unit to direct sunlight. Avoid
installing the unit near heat emitting appliances such as a room heater or stove.
Certificate Number: SGPSGP001496
2. OPERATION
2.1 Operating Instructions
A. Connect the AC input power cable of your UPS to the AC Power. ‘YELLOW’ LED on
the UPS front panel is lit. UPS is charging the battery. (Note: DO NOT connect any load to your UPS until the UPS has charged its battery for 12 hours)
B. Plug computer and monitor to UPS sockets. (Note: Power of computer and monitor
must be less than the maximum total power of your UPS. DO NO T co nn e ct a l aser printer to the UPS backup socket. Laser printers draw a significantly more power than other types of equipment and may overload the UPS.)
C. Switch on the UPS by pressing the power switch on the front panel. The ‘GREEN’ LED
on the UPS front panel is lit and ‘YELLOW’ LED is off. UPS is supplying utility power to the connected equipment and is still charging battery at the same time.
D. When external power source fails, the UPS will power up automatically by batteries.
The ‘YELLOW’ LED is blinking and the UPS has beep sound every 10 seconds. You should save all your data and close all applic ations as soon as possi ble and turn off the UPS.
E. When the batter y output voltage drops to a minimum, the ‘YELLOW’ LED on the UPS
front panel is blinking while generating beeps ever y 1 second. You should turn off the main switch of the UPS.
2.2 UPS Status Information
LED Indication
UPS Status Buzzer
Yellow Green Red
Offline mode, Charge
Battery
No beeps ON OFF OFF
AC mode, UPS Normal No beeps OFF ON OFF
AC abnormal
UPS in battery mode
Once every 10 sec Blinking OFF OFF
Battery voltage low Every sec Blinking OFF OFF
Overload in AC mode Every 0.5 sec OFF ON OFF
Overload in Battery mode Every 0.5 sec Blinking OFF ON
UPS fault / Short circuit Continuous Sounding OFF OFF ON
Discharge Finished No beep OFF OFF OFF