Pro-Link 120071 User Manual

Material Safety Data Sheet
Printed: 25.01.2007
Revised: 25.01.2007
Lithofin Stainstop PLUS
—————————————————————————————————————————————
Product details:
Trade name: Lithofin Stainstop PLUS Application of the substance / the preparation Impregnator
Distributor:
GranQuartz, L. P. P.O. Box 2206 Tucker, GA 30085-2206/USA
Information Department:
see above
Emergency Information:
information department
24-Hour Emergency Telephone Number: 1-800-255-3924 (USA & Canada) or 813-248-0585
—————————————————————————————————————————————
2 Composition/Data on components:
Chemical characterization Description: Solvent based impregnator
Dangerous components:
64742-82-1 Naphta, (petroleum), hydrodesulfurized heavy 50-100 % 183815-50-1 Poly[3-((2-aminoethyl)aminopropyl]methoxy
(dimethyl)methyl(methoxy)siloxan 2.5-10 % 123-86-4 n-butyl acetate 2.5-10 % RTECS: AF 7350000 17980-47-1 Silane, triethoxy(2-methylpropyl)- 2.5-10 %
Additional information Benzene < 0,1 %
TSCA
64742-82-1 Naphta, (petroleum), hydrodesulfurized heavy 123-86-4 n-butyl acetate 17980-47-1 Silane, triethoxy(2-methylpropyl)­—————————————————————————————————————————————
3 Hazards identification
Hazard description:
Harmful Dangerous for the environment
Information pertaining to particular dangers for man and environment
Flammable Irritating to eyes. Toxic to aquatic organisms, may cause long-term adverse effects in the aquatic environment Harmful: may cause lung damage if swallowed. Vapours may cause drowsiness and dizziness
NFPA ratings (scale 0-4)
Health = 2 Fire = 2 Reactivity = 0 —————————————————————————————————————————————
4 First aid measures
General information
1
Material Safety Data Sheet
Printed: 25.01.2007
Revised: 25.01.2007
Lithofin Stainstop PLUS
Immediately remove any clothing soiled by the product.
After inhalation
Remove victim from contaminated area. If breathing is difficult, give oxygen. If breathing stops, provide artificial respiration. Call a doctor.
After skin contact
Clean effected skin thoroughly with water and a mild cleansing agent. No residues shall remain on the skin. If skin irritation continues, consult a doctor.
After eye contact
First check the victim for contact lenses and remove if worn. Rinse the eyes with open eyelids for 10 - 15 minutes with water. Then consult an eye specialist immediately.
After swallowing
Do not induce vomiting; immediately call for medical help. If vomiting occurs spontaneously: Hold the head of the casualty low with the body in a prone position in order to avoid penetration of vomit into the air tube (danger of aspiration).
Information for doctor Treatment
In cases of irritation to the lungs, initial treatment with Dexametason metered aerosol. —————————————————————————————————————————————
5 Fire fighting measures
Suitable extinguishing agents
Foam Extinguishing powder Carbon dioxide Sand Use fire fighting measures that suit the environment.
For safety reasons unsuitable extinguishing agents Water with full jet. Special hazards caused by the material, its products of combustion or resulting gases:
Formation of toxic gases is possible during heating or in case of fire.
Protective equipment:
Wear self-contained respiratory protective device.
Additional information
Dispose of fire debris and contaminated fire fighting water in accordance with official regulations. Collect contaminated fire fighting water separately. It must not enter the sewage system. —————————————————————————————————————————————
6 Accidental release measures
Person-related safety precautions:
Ensure adequate ventilation Wear protective clothing. Keep unprotected persons away.
Measures for environmental protection:
Do not allow product to reach sewage system or any water course. Inform respective authorities in case of seepage into water course or sewage system. Do not allow to penetrate the ground/soil. In case of seepage into the ground inform responsible authorities.
Measures for cleaning/collecting:
Absorb with non-combustible material like sand, soil, diatomite. Ensure adequate ventilation. Send for recovery or disposal in suitable receptacles. Dispose contaminated material as waste according to item 13. —————————————————————————————————————————————
7 Handling and storage
Handling Information for safe handling:
Use only in well ventilated areas.
2
Material Safety Data Sheet
Printed: 25.01.2007
Revised: 25.01.2007
Lithofin Stainstop PLUS
Avoid contact with eyes and skin. Keep receptacles tightly sealed. Use solvent-proof equipment. Avoid inhalation of vapours.
Information about protection against explosions and fires:
Keep ignition sources away - Do not smoke. Protect against electrostatic charges.
Storage Requirements to be met by storerooms and receptacles:
Store receptacles tightly closed at a cool and dry place with sufficient ventilation Prevent any seepage into the ground.
Information about storage in one common storage facility:
Store away from foodstuffs. Store away from feed.
Further information about storage conditions: None. Storage class 3A Flammable liquid
—————————————————————————————————————————————
8 Exposure controls and personal protection
Additional information about design of technical systems:
No further data; see item 7.
Components with limit values that require monitoring at the workplace:
123-86-4 n-butyl acetate PEL: 710 mg/m³, 150 ppm REL: Short-term value: 950 mg/m³, 200 ppm Long-term value: 710 mg/m³, 150 ppm TLV: Short-term value: 950 mg/m³, 200 ppm Long-term value: 713 mg/m³, 150 ppm
Additional information:
The lists that were valid during the creation were used as basis.
Personal protective equipment General protective and hygienic measures
Keep away from foodstuffs, beverages and feed. Wash hands before breaks and at the end of work. Avoid contact with the eyes and skin. Do not inhale dust / smoke / mist. Do not eat or drink while working. Use skin protection cream for skin protection. The usual protective measures based on the application have to be followed. All protective equipment used shall be according to 29 CFR.1910 Subpart I Personal Protective Equipment
Breathing equipment:
Not necessary if room is well-ventilated. Short term filter device: Filter A A respiratory protection program that meets OSHA's 29 CFR 1910.134 and ANSI Z88.2 requirements or European Standard EN 149 must be followed whenever workplace conditions warrant a respirator's use. Always use a NIOSH or European Standard EN 149 approved respirator when necessary.
Protection of hands:
Wear chemically resistant protective gloves (tested according to DIN EN 374) The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation After use of gloves apply skin-cleaning agents and skin cosmetics.
3
Loading...
+ 4 hidden pages