WARNING
FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL
CAREFULLY BEFORE YOUR INITIAL START-UP!
• Before your initial start-up, please make sure that there is no damage caused during transportation.
• Should there be any damage, consult your dealer and do not use the equipment.
• To maintain the equipment in good working condition and to ensure safe operation, it is necessary
for the user to follow the safety instructions and warning notes written in this manual.
• Please note that damages caused by user modications to this equipment are not subject to warranty.
CAUTION!
KEEP THIS EQUIPMENT
AWAY FROM RAIN,
MOISTURE AND LIQUIDS
CAUTION!
TAKE CARE USING
THIS EQUIPMENT!
HIGH VOLTAGE-RISK
OF ELECTRIC SHOCK!!
IMPORTANT:
The manufacturer will not accept liability for any resulting damages caused by the non-observance
of this manual or any unauthorised modication to the equipment.
• Never let the power cable come into contact with other
cables. Handle the power cable and all mains voltage
connections with particular caution!
• Never remove warning or informative labels from the unit.
• Do not open the equipment and do not modify the unit.
• Do not connect this equipment to a dimmer pack.
• Do not switch the equipment on and off in short intervals,
as this will reduce the system’s life.
• Only use the equipment indoors.
• Do not expose to ammable sources, liquids or gases.
• Always disconnect the power from the mains when
equipment is not in use or before cleaning! Only handle
the power-cable by the plug. Never pull out the plug by
pulling the power-cable.
• Make sure that the available mains supply voltage is
between 100~240V AC, 50/60Hz.
• Make sure that the power cable is never crimped or
damaged. Check the equipment and the power cable
periodically.
• If the equipment has been exposed to drastic
temperature uctuation (e.g. after transportation),
do not connect power or switch it on immediately.
The arising condensation might damage the equipment.
Leave the equipment switched off until it has reached
room temperature.
• Never touch the xture during operation as it may be hot.
• If the equipment is dropped or damaged, disconnect the
mains power supply immediately and have a qualied
engineer inspect the equipment before operating again.
• If your product fails to function correctly, stop use
immediately. Pack the unit securely (preferably in the
original packing material), and return it to your Pro Light
dealer for service.
• Only use fuses of same type and rating.
• Repairs, servicing and power connection must only be
carried out by a qualied technician. THIS UNIT CONTAINS
NO USER SERVICEABLE PARTS.
• This lighting xture is for professional use only - it is not
designed for or suitable for household use. The product
must be installed by a qualied technician in accordance
with local territory regulations. The safety of the installation
is the responsibility of the installer. The xture presents
risks of severe injury or death due to re hazards, electric
shock and falls.
• Warning! Risk Group 2 LED product according to
EN 62471. Do not view the light output with optical
instruments or any device that may concentrate the beam.
• WARRANTY: Two years from date of purchase.
OPERATING DETERMINATIONS
If this equipment is operated in any other way, than those described in this manual, the product may suffer damage and
the warranty becomes void. Incorrect operation may lead to danger e.g: short-circuit, burns and electric shocks etc.
Do not endanger your own safety and the safety of others!
Incorrect installation or use can cause serious damage to people and/or property.
www.prolight.co.ukFury 400 DTW 4 Cell Blinder User Manual
2
Product overview & technical specications
Fury 400 DTW 4 Cell Blinder
The Fury IP65 rated blinders are loaded with 90W individually addressable amber and warm white COB LEDs,
which emulate the dimming and colour temperature of a halogen lamp. Each cell features an RGB backlight
creating a truly versatile series, ideal for rental and installation, backed up with the eLumen8 2 year warranty.
• 4 x 90W amber and warm white COB LEDs (1800K/3200K)
• RGB backlights for ‘eye-candy’ effects
• Beam angle: 50°
• 8,562 Lux @ 2m
• 12kHz refresh rate
• Individually addressable LEDs
• DMX channels: 1/4/4/7/9/18/20/23 or 27 selectable
• RDM (Remote Device Management)
• Static colour, colour change, colour fade, auto
and master/slave modes plus built-in programs
• 0-100% dimming and variable strobe
• 4 dimming curves: Linear, square law,
inverse square law and S-curve
• 4 button menu with OLED display
• PowerCON TRUE1 input/output
• IP rated 5-Pin XLR input/output
• Fan cooled
IP65
SpecicationsFury 400 DTW
Power consumption395W
Power supply100~240V, 50/60Hz
FuseF6A 250V
IP ratingIP65
Dimensions398 x 398 x 215mm
Weight11kg
Order codeELUM431
398mm
148mm
148 mm
398mm
50° - Lux 3597689943997
0m1m2m3m4m5m
342mm
215mm
110mm
210mm
22481439
50°
142mm
68mm
www.prolight.co.ukFury 400 DTW 4 Cell Blinder User Manual
3
Technical specications
POWER OUTPUT:
100-240V~50/60Hz
POWER INPUT:
100-240V~50/60Hz
DMX INPUTDMX OUTPUT
www.prolight.co.uk
POWER CONSUMPTION: 395W
Fury 400 DTW Blinder
07
06
05
07
07
04
03
07
0102
01 - OLED display
02 - Function buttons
03 - IP rated 5-Pin DMX input
04 - IP rated 5-Pin DMX output
05 - PowerCON TRUE1 input
06 - PowerCON TRUE1 output
07 - Fans
In the box: 1 x xture,
1 x power cable
& 1 x user manual
Fuse: The Fury 400 Blinder is tted with an internal mains (line) fuse. The fuse must only
be changed by qualied personnel. Before opening the xtures housing or changing the fuse,
the xture must be disconnected and isolated from the mains supply. Replacement cartridge
fuses must be of the same type and rating (20mm Glass F6A 250V). When closing the xture
please ensure the seal is correctly positioned and free from damage to ensure the xture is
water tight and to prevent water ingress.
www.prolight.co.ukFury 400 DTW 4 Cell Blinder User Manual
4
Installation
Before installing the xture, the supporting structure (ie. truss) must be able to hold a minimum of 10
times the xtures weight without any deformation (eg. 15kg - 150kg point load). The xture must be
secured with a secondary safety attachment when being installed (ie. an appropriate safety cable).
Never stand directly below the xture when mounting, removing, and/or servicing.
Overhead installation requires experience and qualications to calculate working load limits, the
material being used at the installation area and periodic safety inspections of the xture and installation
material. If you do not have the relevant experience and/or qualications please do not attempt the
installation yourself. The installation should be checked annually by a qualied person.
The eLumen8 Fury 400 can be operated in a number of mounting positions as shown in the diagram
above, hanging upside-down from the ceiling or truss, mounting sideways on truss or stood upright on
a at level surface. Always use a safety wire as an extra safety precaution to prevent damage/injury
in the event a clamp fails (see the next page for clamp installation). Never use the carry handles for
secondary attachments.
www.prolight.co.ukFury 400 DTW 4 Cell Blinder User Manual
5
Installation
Installation:
1. Fasten the clamp to the xtures bracket.
2. Mount the xture onto your truss system via the clamps and tighten to ensure secure.
3. Pull the safety cable through the safety cable holes located on the metal base plate on the
underside of the xture and around the truss.
1
3
2
www.prolight.co.ukFury 400 DTW 4 Cell Blinder User Manual
6
Operating instructions
Control Panel Menu:
The OLED control panel situated on the front of the xture allows the user to access the menu system to
adjust the xtures settings.
When the unit has been powered on the display will show “Versions” followed by “xx°C xx°C xx°C xx°C”.
The xture will then return to its home screen.
Pressing the “MODE” button once will take the user to the xtures main menu. Using the “UP” and
“DOWN” buttons you can then navigate between the different options in the main menu. Pressing the
“SET” button on one of these options allows you to access the sub menu where you can use the “UP”
and “DOWN” buttons to select option/value required. Once the option/value has been selected press
the “SET” button once more to conrm the setting.
To exit out of any of the above options, press and hold the “MENU” button.
UP
MODESET
DOWN
www.prolight.co.ukFury 400 DTW 4 Cell Blinder User Manual
7
Operating instructions
IMPORTANT! PLEASE NOTE:The OLED display for this xture has a menu locking function where
after 30 seconds ofinactivity it will lock. To unlock the menu hold the “MODE” and “SET” buttons
for 3 seconds.
Main Menu - Defaults are in grey
1: Auto
2: Program
Auto
Yes
Auto
No
Program
1) Mode:
Program
2) Colour:
Program
2) Speed:
Program
3) Strobe:
Program Mode
xx
Colour Preset
xx
Program Speed
xx
Strobe Speed
xx
Auto mode:
To access auto mode, press the “MODE” button
until “1: Auto” is highlighted on the OLED display.
Press the “SET” button and use the “UP” and
“DOWN” buttons to select between “Yes” and
“No”. Press the “SET” button to enter auto mode
when yes is selected.
Built-in programs:
To access the built-in programs, press the
“MODE” button until “2: Program” is highlighted
on the OLED display. Press the “SET” button and
use the “UP” and “DOWN” buttons to highlight
“1) Mode”. Press the “SET” button and use the
“UP” and “DOWN” buttons to select the program
mode required between 01-23. Press the “SET”
button to conrm the setting.
If program mode 01 is selected use the “UP” and
“DOWN” buttons to highlight “2) Colour”. Press
the “SET” button and use the “UP” and “DOWN”
buttons to select the colour required between
01-21. Press the “SET” button to conrm the
setting.
If program mode 02-23 is selected use the “UP”
and “DOWN” buttons to highlight “2) Speed”.
Press the “SET” button and use the “UP” and
“DOWN” buttons to select the speed required
between 001-100. Press the “SET” button to
conrm the setting.
Now use the “UP” and “DOWN” buttons to
highlight “3) Strobe”. Press the “SET” button and
use the “UP” and “DOWN” buttons to select the
strobe speed required between 00-99.
Press the “SET” button to conrm the setting.
www.prolight.co.ukFury 400 DTW 4 Cell Blinder User Manual
8
Main Menu - Defaults are in grey
Operating instructions
3: DMX
DMX
1) Address:
DMX
2) Channels:
DMX Address
xxx
DMX Channels
xx
DMX address:
To access the DMX address setting, press the
“MODE” button until “3: DMX” is highlighted on
the OLED display. Press the “SET” button and use
the “UP” and “DOWN” buttons to highlight
“1) Address”. Press the “SET” button and use
the “UP” and “DOWN” buttons to select the DMX
address required between 001-512. Press the
“SET” button to conrm the setting.
DMX channel:
To access DMX channel mode, press the “MODE”
button until “3: DMX” is highlighted on the OLED
display. Press the “SET” button and use the “UP”
and “DOWN” buttons to highlight
“2) Channels”. Press the “SET” button and use
the “UP” and “DOWN” buttons to select the DMX
channel required 01/04/04/07/09/18/20/23
or 27 selectable. Press the “SET” button to
conrm the setting.
4: Slave
Slave
Yes
Slave
No
Slave mode:
To access slave mode, press the “MODE” button
until “4: Slave” is highlighted on the OLED
display. Press the “SET” button and use the “UP”
and “DOWN” buttons to select between “Yes”
and “No”. Press the “SET” button to enter slave
mode when yes is selected.
www.prolight.co.ukFury 400 DTW 4 Cell Blinder User Manual
9
Operating instructions
5: Dimmer1) White 1
2) Amber 1
3) White 2
4) Amber 2
5) White 3
6) Amber 3
7) White 4
White 1
xxx
Amber 1
xxx
White 2
xxx
Amber 2
xxx
White 3
xxx
Amber 3
xxx
White 4
xxx
Manual mode:
To access the manual dimming mode, press the
“MODE” button until “5: Dimmer” is highlighted
on the OLED display. Press the “SET” button
and use the “UP” and “DOWN” buttons to select
between White Pods 1-4, Amber Pods 1-4,
Backlight R, Backlight G or Backlight B.
Press the “SET” button and use the “UP” and
“DOWN” buttons to adjust the brightness
between 000-255.
Press the “SET” button to conrm the setting.
1
2
8) Amber 4
9) R Ring
10) G Ring
11) B Ring
Amber 4
xxx
R Ring
xxx
G Ring
xxx
B Ring
xxx
Default
000
3
4
www.prolight.co.ukFury 400 DTW 4 Cell Blinder User Manual
10
Operating instructions
6: Halogen
7: Settings
1) Halogen 1
2) Halogen 1
3) Halogen 2
4) Halogen 2
1) Curves Select
Halogen 1
xxx
Halogen 2
xxx
Halogen 3
xxx
Halogen 4
xxx
Default
000
1) Linear
2) Square Law
3) Inv Square
Law
4) S-Curve
Manual halogen mode:
To access the manual halogen dimming mode,
press the “MODE” button until “6: Halogen” is
highlighted on the OLED display. Press the “SET”
button and use the “UP” and “DOWN” buttons to
select between Pods 1-4. Press the “SET” button
and use the “UP” and “DOWN” buttons to adjust
the brightness between 000-255.
Press the “SET” button to conrm the setting.
Dimming curve:
To access the dimming curve setting, press the
“MODE” button until “7: Settings” is highlighted
on the OLED display. Press the “SET” button and
use the “UP” and “DOWN” buttons to select
“1) Curves Select”. Press the “SET” button and
use the “UP” and “DOWN” buttons to select
between “Linear”, “Square Law”, “Inv Square
Law” and “S-Curve”. Press the “SET” button to
conrm the setting.
2) Dimmer
Speed
Fast
Dimming speed:
To access the dimming speed setting, press the
“MODE” button until “7: Settings” is highlighted
Smooth
on the OLED display. Press the “SET” button and
use the “UP” and “DOWN” buttons to select
“2) Dimmer Speed”. Press the “SET” button
and use the “UP” and “DOWN” buttons to select
between “Fast” (LED) or “Smooth” (Halogen).
Press the “SET” button to conrm the setting.
www.prolight.co.ukFury 400 DTW 4 Cell Blinder User Manual
11
3) Dmx Fail1) Blackout
2) Hold
3) Auto
4) Program
Operating instructions
DMX fail setting:
Sets what the xture does when the DMX signal
is lost. To access the DMX fail setting, press the
“MODE” button until “7: Settings” is highlighted
on the OLED display. Press the “SET” button and
use the “UP” and “DOWN” buttons to select
“3) Dmx Fail”. Press the “SET” button and use
the “UP” and “DOWN” buttons to select between
“Blackout”, “Hold”, “Auto” and “Program”.
Press the “SET” button to conrm the setting.
4) Dmx Sync
5) Lock
Dmx Sync
On
Dmx Sync
Off
Lock
On
Lock
Off
Dmx synchronisation:
To access the DMX sync setting, press the
“MODE” button until “7: Settings” is highlighted
on the OLED display. Press the “SET” button and
use the “UP” and “DOWN” buttons to select
“4) Dmx Sync”. Press the “SET” button and use
the “UP” and “DOWN” buttons to select between
“On” and “Off”. Press the “SET” button to enable
Dmx sync when yes is selected.
Please note: The DMX Synchronisation setting
should be set to on when using the built-in
presets via DMX to ensure the xtures stay
synchronised.
Display lock:
To access the display lock setting, press the
“MODE” button until “7: Settings” is highlighted
on the OLED display. Press the “SET” button and
use the “UP” and “DOWN” buttons to select
“5) Lock”. Press the “SET” button and use the
“UP” and “DOWN” buttons to select between
“On” and “Off”. Press the “SET” button to enable
Display Lock when yes is selected.
Please note: After 30 seconds ofinactivity the
display will lock. To unlock the menu hold the
“MODE” and “SET” buttons for 3 seconds.
www.prolight.co.ukFury 400 DTW 4 Cell Blinder User Manual
12
Operating instructions
8: Information
6) Factory
Versions:
xx°C xx°C xx°C xx°C
UID:
Factory
Yes
Factory
No
Factory reset:
Resets all the xtures factory settings.
To access the factory setting reset, press the
“MODE” button until “7: Settings” is highlighted
on the OLED display. Press the “SET” button and
use the “UP” and “DOWN” buttons to select
“6) Factory”. Press the “SET” button and use the
“UP” and “DOWN” buttons to select between
“Yes” and “No”. Press the “SET” button to
perform the factory reset when yes is selected.
Fixture information:
Displays the xtures version, each pods
temperature and RDM ID.
To display the xture information, press
the “MODE” button until “8: Information” is
highlighted on the OLED display. Press the
“SET” button and the xtures version, each pods
temperature and RDM ID will be displayed.
www.prolight.co.ukFury 400 DTW 4 Cell Blinder User Manual
13
1
3
2
4
Operating instructions
7 channel mode:
ChannelValueFunction
CH1000-255
CH2000-255
CH3000-255
CH4000-255
CH5000-255Red backlight dimmer 0-100%
CH6000-255
CH7000-255
Pod 1 halogen dimmer
0-100%
Pod 2 halogen dimmer
0-100%
Pod 3 halogen dimmer
0-100%
Pod 4 halogen dimmer
0-100%
Green backlight dimmer
0-100%
Blue backlight dimmer
0-100%
1 channel mode:
ChannelValueFunction
CH1000-255Halogen dimmer 0-100%
4 channel mode 1:
ChannelValueFunction
CH1000-255Halogen dimmer 0-100%
CH2000-255Red backlight dimmer 0-100%
CH3000-255
CH4000-255
Green backlight dimmer
0-100%
Blue backlight dimmer
0-100%
4 channel mode 2:
ChannelValueFunction
CH1000-255
CH2000-255
CH3000-255
CH4000-255
Pod 1 Halogen dimmer
0-100%
Pod 2 Halogen dimmer
0-100%
Pod 3 Halogen dimmer
0-100%
Pod 4 Halogen dimmer
0-100%
9 channel mode:
ChannelValueFunction
CH1000-255
CH2000-255
CH3000-255
CH4000-255
CH5000-255
CH6000-255
CH7000-255Red backlight dimmer 0-100%
CH8000-255
CH9000-255
Halogen master dimmer
0-100%
Pod 1 halogen dimmer
0-100%
Pod 2 halogen dimmer
0-100%
Pod 3 halogen dimmer
0-100%
Pod 4 halogen dimmer
0-100%
Backlight master dimmer
0-100%
Green backlight dimmer
0-100%
Blue backlight dimmer
0-100%
www.prolight.co.ukFury 400 DTW 4 Cell Blinder User Manual
14
Operating instructions
18 channel mode:
ChannelValueFunction
CH1000-255
CH2000-255
CH3000-255
CH4000-255
CH5000-255
CH6000-255
CH7000-255
CH8000-255
CH9000-255
CH10000-255
CH11000-255
CH12000-255
CH13000-255
CH14000-255
CH15000-255
CH16000-255
CH17000-255
CH18000-255
Halogen master dimmer
0-100%
Pod 1 halogen dimmer
0-100%
Pod 2 halogen dimmer
0-100%
Pod 3 halogen dimmer
0-100%
Pod 4 halogen dimmer
0-100%
Backlight master dimmer
0-100%
Pod 1 red backlight dimmer
0-100%
Pod 1 green backlight dimmer
0-100%
Pod 1 blue backlight dimmer
0-100%
Pod 2 red backlight dimmer
0-100%
Pod 2 green backlight dimmer
0-100%
Pod 2 blue backlight dimmer
0-100%
Pod 3 red backlight dimmer
0-100%
Pod 3 green backlight dimmer
0-100%
Pod 3 blue backlight dimmer
0-100%
Pod 4 red backlight dimmer
0-100%
Pod 4 green backlight dimmer
0-100%
Pod 4 blue backlight dimmer
0-100%
20 channel mode:
ChannelValueFunction
CH1000-255
CH2000-255Pod 1 amber dimmer 0-100%
CH3000-255
CH4000-255Pod 2 amber dimmer 0-100%
CH5000-255
CH6000-255Pod 3 amber dimmer 0-100%
CH7000-255
CH8000-255Pod 4 amber dimmer 0-100%
CH9000-255
CH10000-255
CH11000-255
CH12000-255
CH13000-255
CH14000-255
CH15000-255
CH16000-255
CH17000-255
CH18000-255
CH19000-255
CH20000-255
Pod 1 warm white dimmer
0-100%
Pod 2 warm white dimmer
0-100%
Pod 3 warm white dimmer
0-100%
Pod 4 warm white dimmer
0-100%
Pod 1 red backlight dimmer
0-100%
Pod 1 green backlight dimmer
0-100%
Pod 1 blue backlight dimmer
0-100%
Pod 2 red backlight dimmer
0-100%
Pod 2 green backlight dimmer
0-100%
Pod 2 blue backlight dimmer
0-100%
Pod 3 red backlight dimmer
0-100%
Pod 3 green backlight dimmer
0-100%
Pod 3 blue backlight dimmer
0-100%
Pod 4 red backlight dimmer
0-100%
Pod 4 green backlight dimmer
0-100%
Pod 4 blue backlight dimmer
0-100%
www.prolight.co.ukFury 400 DTW 4 Cell Blinder User Manual
15
23 channel mode:
ChannelValueFunction
CH1000-255Master dimmer 0-100%
CH2
CH3000-255
CH4000-255Pod 1 amber dimmer 0-100%
CH5000-255
CH6000-255Pod 2 amber dimmer 0-100%
CH7000-255
CH8000-255Pod 3 amber dimmer 0-100%
CH9000-255
CH10000-255Pod 4 amber dimmer 0-100%
CH11000-255
CH12000-255
CH13000-255
CH14000-255
CH15000-255
CH16000-255
CH17000-255
CH18000-255
CH19000-255
CH20000-255
CH21000-255
CH22000-255
CH23000-255
000-010No function
011-255Strobe (slow-fast)
Pod 1 warm white dimmer
0-100%
Pod 2 warm white dimmer
0-100%
Pod 3 warm white dimmer
0-100%
Pod 4 warm white dimmer
0-100%
Backlight master dimmer
0-100%
Pod 1 red backlight dimmer
0-100%
Pod 1 green backlight dimmer
0-100%
Pod 1 blue backlight dimmer
0-100%
Pod 2 red backlight dimmer
0-100%
Pod 2 green backlight dimmer
0-100%
Pod 2 blue backlight dimmer
0-100%
Pod 3 red backlight dimmer
0-100%
Pod 3 green backlight dimmer
0-100%
Pod 3 blue backlight dimmer
0-100%
Pod 4 red backlight dimmer
0-100%
Pod 4 green backlight dimmer
0-100%
Pod 4 blue backlight dimmer
0-100%
Operating instructions
www.prolight.co.ukFury 400 DTW 4 Cell Blinder User Manual
16
27 channel mode:
Operating instructions
ChannelValueFunction
CH1000-255Master dimmer 0-100%
CH2
CH3
CH4
CH5
000-010No function
011-255Strobe (slow-fast)
000-010No function
011-255Random strobe (slow-fast)
000-010No function
011-021All pods - Warm white
022-032All pods - Amber
033-043
044-054
055-065
066-076
077-087
088-098All pods - Red
099-109All pods - Green
110-120All pods - Blue
121-131All pods - Orange
132-142All pods - Medium Yellow
143-153All pods - Yellow
154-164All pods - Magenta
165-175All pods - Hot Pink
176-186All pods - Cyan
187-197All pods - Coral
198-208All pods - Mint Green
209-219All pods - Lilac
220-230All pods - Dark Yellow
231-255All pods - White (RGB)
000-015No function
016-026Program 2
027-037Program 3
038-048Program 4
049-059Program 5
060-070Program 6
071-081Program 7
082-092Program 8
093-103Program 9
Pod 1 & 3 - Warm white
Pod 2 & 4 - Amber
Pod 1 & 3 - Amber
Pod 2 & 4 - Warm white
Pod 1 & 2 - Warm white
Pod 3 & 4 - Amber
Pod 1 & 2 - Amber
Pod 3 & 4 - Warm white
All pods - Warm white
& Amber
ChannelValueFunction
104-114Program 10
115-125Program 11
126-136Program 12
137-147Program 13
148-158Program 14
159-169Program 15
CH5 (cont.)
CH6000-255Program speed (slow-fast)
CH7000-255
CH8000-255Pod 1 amber dimmer 0-100%
CH9000-255
CH10000-255Pod 2 amber dimmer 0-100%
CH11000-255
CH12000-255Pod 3 amber dimmer 0-100%
CH13000-255
CH14000-255Pod 4 amber dimmer 0-100%
CH15000-255
CH16000-255
CH17000-255
CH18000-255
CH19000-255
CH20000-255
CH21000-255
CH22000-255
170-180Program 16
181-191Program 17
192-202Program 18
203-213Program 19
214-224Program 20
225-235Program 21
236-246Program 22
247-255Program 23
Pod 1 warm white dimmer
0-100%
Pod 2 warm white dimmer
0-100%
Pod 3 warm white dimmer
0-100%
Pod 4 warm white dimmer
0-100%
Backlight master dimmer
0-100%
Pod 1 red backlight dimmer
0-100%
Pod 1 green backlight dimmer
0-100%
Pod 1 blue backlight dimmer
0-100%
Pod 2 red backlight dimmer
0-100%
Pod 2 green backlight dimmer
0-100%
Pod 2 blue backlight dimmer
0-100%
Pod 3 red backlight dimmer
0-100%
www.prolight.co.ukFury 400 DTW 4 Cell Blinder User Manual
17
27 channel mode (cont.):
ChannelValueFunction
CH23000-255
CH24000-255
CH25000-255
CH26000-255
CH27000-255
Pod 3 green backlight dimmer
0-100%
Pod 3 blue backlight dimmer
0-100%
Pod 4 red backlight dimmer
0-100%
Pod 4 green backlight dimmer
0-100%
Pod 4 blue backlight dimmer
0-100%
Operating instructions
www.prolight.co.ukFury 400 DTW 4 Cell Blinder User Manual
18
DMX setup
Setting the DMX address:
The DMX mode enables the use of a universal DMX controller. Each xture requires a “start address”
from 1- 512. A xture requiring one or more channels for control begins to read the data on the channel
indicated by the start address. For example, a xture that occupies or uses 7 channels of DMX and was
addressed to start on DMX channel 100, would read data from channels: 100, 101, 102, 103, 104,
105 and 106. Choose a start address so that the channels used do not overlap. E.g. the next unit in
the chain starts at 107.
DMX 512:
DMX (Digital Multiplex) is a universal protocol used as a form of communication between intelligent
xtures and controllers. A DMX controller sends DMX data instructions form the controller to the xture.
DMX data is sent as serial data that travels from xture to xture via the DATA “IN” and DATA “OUT”
XLR terminals located on all DMX xtures (most controllers only have a data “out” terminal).
DMX linking:
DMX is a language allowing all makes and models of different manufactures to be linked together
and operate from a single controller, as long as all xtures and the controller are DMX compliant.
To ensure proper DMX data transmission, when using several DMX xtures try to use the shortest
cable path possible. The order in which xtures are connected in a DMX line does not inuence the
DMX addressing. For example; a xture assigned to a DMX address of 1 may be placed anywhere in
a DMX line, at the beginning, at the end, or anywhere in the middle. When a xture is assigned a
DMX address of 1, the DMX controller knows to send DATA assigned to address 1 to that unit,
no matter where it is located in the DMX chain.
DATA cable (DMX cable) requirements (for DMX operation):
This xture can be controlled via DMX-512 protocol. The DMX address is set on the back of the unit.
Your unit requires either a standard 3-pin or 5-pin XLR connector for data input/output,
see images below.
Further DMX cables can be purchased from all good sound and lighting suppliers or Prolight Concepts dealers.
Please quote:
Also remember that DMX cable must be daisy chained and cannot be split.
CABL10 – 2mCABL11 – 5mCABL12 – 10m3-Pin:
CABL185 – 2mCABL187 – 5mCABL188 – 10m5-Pin:
www.prolight.co.ukFury 400 DTW 4 Cell Blinder User Manual
19
Notice:
DMX setup
Be sure to follow the diagrams below when making your own cables.
Do not connect the cables shield conductor to the ground lug or
allow the shield conductor to come in contact with the XLRs
outer casing. Grounding the shield could cause a short circuit
and erratic behaviour.
DMX 512
3-Pin XLR output
1
3
2
DMX 512
5-Pin XLR output
1
2
3
4
5
GROUND
DMX –
N/C
DMX +
DMX –
GROUND
DMX +
N/C
DMX 512
3-Pin XLR input
1
3
2
DMX 512
5-Pin XLR input
1
2
3
4
5
3-Pin XLR male3-Pin XLR female
1 ground
3 hot
5-Pin XLR male5-Pin XLR female
1 ground5 N/C
2 cold
3 hot
2 cold
4 N/C
Pin Conguration
3-Pin5-Pin
Pin 1 - Ground
Pin 2 - Negative
Pin 3 - Positive
–Pin 4 - N/C
–Pin 5 - N/C
2 cold
5 N/C1 ground
4 N/C
3 hot
3 hot
1 ground
2 cold
Line termination:
When longer runs of cable are used,
you may need to use a terminator on
the last unit to avoid erratic behaviour.
Using a cable terminator will decrease
the possibilities of erratic behaviour.
(3-pin - Order ref: CABL90,
3-Pin
12
3
Termination reduces signal
transmission problems and
interference. It is always
advisable to connect a DMX
terminal, (resistance 120
Ohm 1/4W) between pin 2
(DMX-) and pin 3 (DMX+) of
the last xture.
5-Pin
1
24
3
5
5-pin - Order ref: CABL89)
5-pin XLR DMX connectors:
Some manufactures use 5-pin XLR connectors for data transmission in place of 3-pin. 5-pin XLR xtures
may be implemented in a 3-pin XLR DMX line. When inserting standard 5-pin XLR connectors in to a
3-pin line a cable adaptor must be used. The diagram below details the correct cable conversion.