Projecta AC150, AC250B, AC400, AC600, AC800 Instruction Manual

...
AUTOMATIC
BATTERY CHARGER
CHARGE N’ MAINTAIN
P/No’S. AC150, AC250B, AC400, AC600, AC800, AC1000, AC1500, AC600-24
2
Explosive gases. Prevent flames and sparks. Provide adequate ventilation during
charging.
Before charging, read the instructions.
For indoor use. Do not expose to rain.
For charging lead acid batteries ONLY (of the size & voltage specified in the specifications table).
Disconnect the 240V mains supply before making or breaking the connections to the battery.
Do not attempt to charge non-rechargeable batteries.
Never charge a frozen battery.
This appliance is not intended for use by young children or infirm persons unless they
have been adequately supervised by a responsible person to ensure that they can use the appliance safely.
Young children should be supervised to ensure that they do not play with the
appliance.
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or
similarly qualified persons in order to avoid a hazard.
After charging, disconnect the battery charger from the supply mains. Then remove the chassis connection and then the battery connection.
3
FEATURES
Automatic Charger
An automatic battery charger stops charging when the battery is full. You can leave the charger connected to the battery without risk of overcharging. Once the battery is full, the battery charger will automatically start to maintain the battery. The charger monitors the battery
Voltage
and continues to top up the battery, keeping it fully charged and ready for use.
Thermal Overload/Polarity Protection
Prevents the output leads from sparking due to accidental reverse connection or short circuit making the charger safer to use around batteries.
LED Charge Indication
Three LEDs display the charger’s status (except AC250B).
• RED LIGHT ON: Power On,
• ORANGE LIGHT ON: Charging,
• GREEN LIGHT ON: Fully charged and maintaining.
Wiring harness (AC150 & AC250B only)
The wiring harness allows for easy connection to vehicles that have hard to reach batteries. Includes an inline fuse (AC150) to protect the harness from accidental short circuits.
‘On Board’ Battery Charging (AC250B only)
The AC250B ‘On Board’ charger allows the charger to be conveniently mounted on the vehicle next to the battery. This is an ideal solution for vehicles left unused for some time. When the vehicle is to be garaged, simply pop the hood and plug the charger in to a 240 Volt extension cord. When the vehicle is to be used, disconnect the extension cord, close the hood and start the engine, it’s that easy!
Multi Voltage (AC400 only)
Can charge either 6V or 12V batteries.
Engine Start (AC800 only)
When
time is short, this feature will deliver the battery a short yet powerful enough charge
to start the engine.
Toroidal Transformer (AC1000, AC1500 & AC600-24 only)
Using the latest technology in transformer design, toroidal transformers don’t use a solid iron core (like traditional transformers) making them lighter and more compact. They deliver more power than a traditional transformer charger of the same size.
4
SPECIFICATIONS
P/No. AC150 AC250B AC400 AC600 AC800 AC1000 AC1500 AC600-24
Type: AUTOMATIC AUTOMATIC AUTOMATIC AUTOMATIC AUTOMATIC AUTOMATIC AUTOMATIC AUTOMATIC
Input: 240VAC 50Hz 240VAC 50Hz 240VAC 50Hz 240VAC 50Hz 240VAC 50Hz 240VAC 50Hz 240VAC 50Hz 240VAC 50Hz
Input power: 0.09A (17W) 0.2A (28W) 0.23A (53W) 0.37A (70W) 0.43A (91W) 0.5A (108W) 0.83A (161W) 0.6A (116W)
Output Voltage: (Nominal) 12VDC 12VDC 6 VDC/12VDC 12VDC 12VDC 12VDC 12VDC 24VDC
Output Current: 900mA@12V 1600mA@12V 2700mA 4300mA@12V 5400mA@12V 6200mA@12V 10000mA@12V 3500mA@24V
(Continuous) @6 or 12V
Engine Start: N/A N/A N/A N/A 3 Cycles: N/A N/A N/A
5min ‘ON’
20min ‘OFF’
Suitable for Charging 12V Battery 12V Battery 6 or 12V Battery 12V Battery 12V Battery 12V Battery 12V Battery 2 x 12V
in series (24V)
Battery Range: (CCA) 100-350* 200-650* 250-550 250-650 300-700 300-800 450-1000 400-900*
(MCA) 150-400* 250-700* 250-600 300-700 375-800 375-900 600-1200 450-1000*
(Ah) 7-24 16-40 20-70 25-80 35-100 50-100 65-150 35-70
Minimum Start Voltage: 5V 5V 3V 3V 3V 3V 3V 15V
Charge Control: (Cut out) 14.2V 14.2V 7.1/14.2V 14.2V 14.2V 14.2V 14.2V 28.4V
(Cut in) 13.4V 13.4V 6.7/13.4V 13.4V 13.4V 13.4V 13.4V 26.8V
Size: 65x85x95mm 123x43x120mm 150x140x85mm 150x140x85mm 190x220x120mm 190x220x120mm 190x220x120mm 190x220x120mm
Weight: 0.75Kg 1.3Kg 1.5Kg 1.9Kg 2.5Kg 2.6Kg 3.4Kg 2.6Kg
*Only suitable for maintaining larger size batteries.