FLTCON-2-24VDC
Data Sheet
Input Voltage
Output Voltage
Current Rating total
Current Rating per channel
Number of Channels
Feedback Input
Duty Cycle
Operational Temperature
Housing Color
Housing Material
Certifications
Dimensions (LxWxH)
Unit Weight
Warranty
24VDC
24VDC
15A
10A
2
Hall Effect Sensor
10% (2 min on, 18 min off)
5°C to 40°C
Black
POM
None
7.75" x 5.25" x 3.00"
0.56lbs
18 Months

Dimensions
1.1
6.0
1.5
5.3
2.9
Operational Procedure
To raise the actuator(s) or column(s), press and hold the UP button. To lower the actuator(s) or
column(s), press and hold the DOWN button. The UP and DOWN buttons are momentary controlled.
When either directional buttons are released, the actuator(s) or column(s) will stop immediately.
To save a position, move the actuator(s) or column(s) to the desired height. Press the “M” button
followed by a number. The LED display will flash an 'S', followed by an 'S - Number'. This will indicate
that the position has been saved. To use a preset, press any of the numbered buttons and the
actuator(s) or column(s) will begin to move to the preset position. It is important to ensure that no
obstacles impede the motion of travel. To stop motion while in travel, press any button. If the connected
actuator(s) or column(s) do not function as intended or the LED display flashes "RST", please follow the
Reset Procedure outlined below.
Reset Procedure
To enter the Reset Procedure, press and hold the DOWN button on the Hand Remote until the LED
shows "RST" (If you are not using an LED hand remote, hold the DOWN button for about 10 seconds).
Release the DOWN button. Press and hold the DOWN button once more until the actuator(s) or
column(s) lower completely then slightly rise before coming to a stop. This signals the end of the reset
procedure. Release the DOWN button and your system is now ready to use.
If any error message persist after completing the reset procedure, contact us at 1-800-676-6123 or by
email at sales@progressiveautomations.com to receive assistance from our available technicians.
*If the height difference between the legs exceeds 1.5 inches, stop the reset procedure & contact us.
*lf the handset displays ‘HOT’, let the unit cool down for 20 minutes before starting the reset procedure
again.
2

Setting Upper & Lower Limits
Upper Limit
To set the upper limit, use the UP/DOWN buttons to move the table lift to your desired max
height position. Once it is at the desired position, press and hold the "M" button until the
LED display flashes "S-" once, then release the button. Press and release the button two
more times in quick succession. The LED display should then show "999" on the third press
and then automatically return to the desired height. The upper limit is now set.
Lower Limit
To set the upper limit, use the UP/DOWN buttons to move the table lift to your desired
minimum height position. Once it is at the desired position, press and hold the "M" until the
LED display flashes "S-" once, then release the button. Press and release the button two
more times in quick succession. The LED display should then show "000" on the third press
and then automatically return to the desired height. The lower limit is now set.
Removing Limits
To remove the upper and lower limits, use the UP/DOWN buttons to move the desk to any
desired position. Press and hold the "M" button until the LED display flashes "S-" once, then
release the button. Press and release the button in succession until the display changes to
"555"(ignore any other readings). After a few seconds, the display will automatically change
back to the numbered height position. Upper and lower limits should now be removed.
*After the upper and lower limits are set, the previous memory positions (1,2,3,4) may be
outside the new range of movement. If this happens, simply reset the memory positions.
*A Reset procedure requires the desk base to fully retract beyond any lower limit. Please
ensure you have proper clearance below the desk base.
*If you attempt to revise a previously set upper or lower limit and it is outside of the existing
range, you will need to remove the original upper/lower limits first.
3

Troubleshooting
Problem Possible Cause Corrective Action
Low power mode
Remote LED is off.
activated
Connection issue
Troubleshooting Guide
Press any button on the remote and LED will activate.
Disconnect and reconnect the RJ-45 remote connector. Ensure connection is
secure and cable is not damaged.
Lifting columns do
not move when
motion control
buttons are pressed.
Lifting columns travel
at a significantly
slower speed than
rated specification.
Unusual noise during
travel.
Lifting columns stop
abruptly during travel.
Lifting columns are
not level.
Limit switch reached
Connection issue
Weight issue Ensure weight capacity has not exceeded the maximum load rating.
Weight issue Ensure weight capacity has not exceeded the maximum load rating.
Obstacle
Out of sync
Follow "Setting Limit Switches" instructions to remove the programmed
limit (FLTCON-02 only). If maximum or minimum height limit has been
reached, please move the system in the opposite direction.
Disconnect and reconnect the Lifting Columns, Control Box, AC Power, and
Remote.
Ensure there are no obstacles in the path of the lifting columns. If the
movement continues to fail, initiate the Reset Procedure.
Disconnect and reconnect all cables (Lifting Column, Control Box, AC Power,
and Remote), then initiate the Reset Procedure.
Error Codes (remotes with LED display)
Error Code Error Summary Description
E01 M1 overcurrent protection
E02 M2 overcurrent protection
E03 M3 overcurrent protection
E04 M4 overcurrent protection
All columns stop moving and remote displays E01-E04. Ensure that the total
weight capacity of the lifting columns has not been exceeded and that no
obstacles obstruct the movement. Press any key and remote will display
RST, initiate the Reset Procedure. If the issue persists, disconnect and
reconnect all of the lifting columns, including the main power. Repeat the Reset
Procedure.
E07 M1 hall error
E08 M2 hall error
E09 M3 hall error
E10 M4 hall error
H01
Over heat /duty cycle
protection
All columns stop moving and remote displays E07-E10. Ensure that all columns
are still properly connected to the control box. Check to see if any cables have
been damaged. Press any key and remote will display RST, initiate the Reset
Procedure. If the issue persists, disconnect and reconnect all of the lifting
columns, including the main power. Repeat the Reset Procedure.
All columns stop moving, remote displays H01 (if LED screen available). Allow
the system to rest for 16 minutes, use normally. Follow the Duty Cycle rating to
ensure no issues arise from overheating.
4