Features and Specifications
“Plug & Play” – easy connection terminals. Can be set for wired override control.
INCLUDED IN BOX
1x 1x
Control Box Power Harness with in-line 30A fuse (Not designed to fail when there is too much load or obstruction of actuator)
2x
Number of Channels
Feedback Input
Duty Cycle
Operational Temperature
Housing Color
Housing Material
Certifications
Kit Includes
Wireless Frequency
Wireless Range
Remote Functions
Remote Battery Type
Warranty
Input Voltage
Output Voltage
Current Rating Total
Current Rating Per Channel
Dimensions
Unit Weight
Wireless Remotes
2 (Matching Linear Actuators)
Hall Effect Sensors
10% (2 min on, 18 min off)
-30° C to 80°C
Black
Plastic
CE
1 Control Box, 2 Wireless Remotes, 1 Power Wire
Harness w/ in-line 30A fuse
43.92 MHz
100 feet
Up, Down, Pause (Momentary/Non-Momentary)
2x CR2016 3V Lithium Cell
18 Months
12 VDC 24 VDC
10.9 VDC 19.7 VDC
20 A 20 A
10 A 10 A
5.9" x 3.9" x 1.3" 5.84" x 6.87" x 2.83"
0.6 lbs 0.6lbs
Operation
a) Power: Once power is applied through the wiring harness, the control box will beep once to signal that it is powered. Please note that a power supply that is not rated for the full load current of the actuators will have the actuator behave erratically.
b) Programming the Wireless Remote: To program a wireless remote with the control box, you must first remove the black box to expose the circuit board. Once the circuit board is powered, press and hold switch ‘S1’ at the same time as the UP or DOWN button on the wireless remote. The control box will beep to signal that the programming is complete. Up to 4 wireless remotes can be programmed to a control box. To erase a previously programmed wireless remote, simply program the control box 4 times with a different remote.
c) Setup/Reset Procedure: With the control box powered on and the actuators connected, you must reset the system before operation. To do this, press the UP and DOWN button on the wireless remote for 3 seconds. The control box will beep 3 times to signal the beginning of the reset procedure. During this time the actuators cannot be controlled and it will be operating at half speed. Once the reset procedure is finished the control box will beep once. This signals that it is ready for operation. To reset the control box using the wired rocker switch, power off the control box. Press and hold the down button on the rocker switch and power on the PA-40. The down button must be held for 3 seconds while the control box is on. Once the PA-40 makes a beep, release the down button to initiate the Reset Procedure.
*Reset Warning: There is no synchronization in either Reset Mode (see page 4), it is important to ensure that both actuators are unloaded. If unavoidable, we recommend using the Secondary Reset Mode, however binding can still occur depending on the application.
At any point during either Reset Procedure, any command from the wireless or wired remote will cancel the procedure. It is important to complete a full reset procedure in either mode to achieve proper functionality.
d) Out-of-sync Error: During operation if one of the actuators is unplugged or unable to operate the
box will go into an error state. Both actuators will stop moving and the control box will beep until it is powered off or the Reset Procedure is started.
e) Wired Control: Another method of control is a wired rocker switch. This method only operates in
momentary mode and will automatically override any commands from the wireless remote. An illustration of the connections required can be found under the Wiring Diagram section.
Operation Modes
POSITION MODE OPERATION
Non-Momentary Control (default)
Momentary Control
Primary
Reset Mode
Press UP or DOWN to go
forward or backward. Press
it again to stop.
Hold UP or DOWN to go
forward or backward.
Release it to stop.
Both actuators will
complete a full retraction,
extension and retraction.
Actuators will not travel in
synchronous motion
Secondary
Reset Mode
Both actuators will
retract at 70% speed. Actuators will not travel in synchronous motion.
Wiring Diagram
A. WIRED ROCKER SWITCH
1. Extend
2. COM
3. Retract
B. HALL EFFECT ACTUATOR
C. POWER
1. Signal 1
2. GND
3. +5 VDC
4. M-
5. M+
6. Signal 2
1. Power +VDC
2. Power COM