Profi-pumpe ENVIRO-TECH 550, TP-EU02144 Operating Instructions Manual

SUBMERSIBLE PUMP (CLEAN WATER)
KLARWASSER TAUCHPUMPE
Version 15.06.
Technical changes, misprints and mistakes reserved! Newest information about our products can be found online
Technische Änderungen, Druckfehler und Irrtümer vorbehalten! Aktuelle Informationen zu unseren Produkten nden Sie auf:
http://www.pro-pumpe.de
OPERATING INSTRUCTIONS
BEDIENUNGSANLEITUNG
de
TAUCHDRUCKPUMPE ENVIRO-TECH 550
TP-EU02144
Contents
1. Introduction ......................................................................................................................................................... 2
2. In general ............................................................................................................................................................ 2
3. Ranges of application .......................................................................................................................................... 2
4. Operation ............................................................................................................................................................ 3
5. Security tips .......................................................................................................................................................... 3
6. Servicing ............................................................................................................................................................. 3
7. Guarantee regulations ......................................................................................................................................... 3
8. Recognising and repairing of mistakes ............................................................................................................... 4
9. Notes on Product Liability ................................................................................................................................... 4
10. Notes on Disposal ............................................................................................................................................... 4
11. EU Declaration of Conformity .............................................................................................................................. 4
12. Technical Data ..................................................................................................................................................... 8
English 32 English
1. INTRODUCTION
We would like to congratulate you on the purchase of our pump. We appreciate your trust. That‘s why funtional secu­rity and operational safety stands by us on rst place.
To prevent damage to persons or property, you should read this user manual carefully. Please observe all safety precautions and instructions for proper use of the pump. Failure to follow the instructions and safety precautions can result in injury or property damage. Please keep this manual with the instructions and safety instructions carefully in order to at any time you can restore them. Please always download the latest version of the user manual of www.
pro-pumpe.de under „downloads“. This shall always prevail.
2. IN GENERAL
The pumps in the catagorie Centrifugal Pumps are developed according to the newest stand of technology, manufac­tured with much care and go under strict intensive controls. The pumps were optimised by us in particular for their special demands. Make sure after unpacking the pump that the data given on the type label agree with the included operating instructions. In the case of doubt the pump is not to be used. Transport damages are immediately to be reported to the package distributor and to us in witten form.
3. RANGES OF APPLICATION
These pumps are made for pumping clear water (free of mud and sand, see technical data)
The pumps are made for the following ranges of application:
l Filling and emptying rain tanks and containers l For water re-circulation l For rainwater use in house and garden l Pumping water from a brook a stream l Use in a pond l Others
IMPORTANT!
The pumps are designed for pumping clean water and chemically non-aggressive liquids. Any guarantee is void in case of improper use. They are not suitable for pumping ammable liquids or for use in places where there is danger of an explosion. The pumps are designed for home use in the house and garden. The pumps Innotec 1000, 1250 and 1500 are designed for continuous operation for professional work. In continuous operation mode, the lifetime will be shortened accordingly. Never run more than 5 minutes against a closed valve pump. Save the pump against dry running (install dry run protection).
Never start and stop the pump more than 20 times per hour. When the pump clocks, any claim under warran­ty is void. Not suitable for use with solar photovoltaic panels. Submersible pumps may not be used in swimming pools.
4. OPERATION
The installation must be performed by a qualied professional.
Please, check each time before using, the electrical connections and the cables are not damaged. Check
before the installation whether the electrical connections are earthed according to the statutory regulations and are installed. The pump is to be secured through a RCD circuit breaker with release current of 30 mA. is technically correct, so this warranty is void. It must be ensured that the pump is sufciently cooled during prolonged operation.
It is not recommended to perform even cable extensions or other technical modications. The lines to the pump must be installed always steadily rising. A transfer of mechanical loads or vibrations from the pump or must be eliminated through appropriate measures (rubber buffers, braided hoses, line xation, etc.). Do not reduce the pressure and suction line. All cables to and from the pump must be sealed. We recommend that you perform the suction line „in one piece“ without interruption in order to avoid leaks. Check valve and water pipes for leaks at least by means of pressure testing. 24h. test. Is expected dirt in the pump, an effective pre-lter should be installed upstream of the pump. Fill pump and suction pipe with water. Electrically connect pump with power supply. Start pump. If necessary, the pump and the suction line must be relled until a normal continuous operation has been established.
5. SECURITY TIPS
l Obey absolutely valid regulations on the electrical security l Never run pump dry l Pumping inammable, as well as all other aggressive liquids is prohibited l Pay attention to the medium temperature max. 35°C l Never pull the pump on the electrical cable or pressure hose l Avoid cross section narrowing l Pay attention to the given particle size l During longer unused times, clean the pump, wash it out with clear water, dry and store it at room temperature l Test wells for enough owing water (dry run danger) l The pump is to be secured through a RCD circuit breaker with a release current of 30 mA. l The electrical connections are always to be carried out by an authorised professional l Operation can not be performed by children and young people under 16 and people with intellectual disabilities
THE MANUFACTURER EXPLAINS:
l To take over no responsibility in the case of accidents or damages on the basis of carelessness or disregard to the instructions in this book. l To reject every responsibility for the damages which originate from the improper use of the pump.
6. SERVICING
Under normal pumping conditions the pump requires no servicing. From an operating period (with clear water) of approx. 2000 hours the mechanical components should be checked: impeller wheels, chambers, sealing rings etc. on wear and if necessary be changed. After 3000 pumping hours the oil in the chamber should also be changed, if necessary (only with oil-dipped engine types!). Please, only ll it up to 80% and check the sealing rings always for density. With abrasive materials like sand the servicing duration can become shorter. The following controls should be carried out regularly:
l Intactness of the electric cable l That the connection hoses are not bent or broken l Cleanness of the pump medium
Moreover, the pump should be emptied with risk of frost, be washed out with clear water and stored dry.
7. GUARANTEE REGULATIONS
For all manufacturing and material defects, the statutory warranty applies. In these cases we take the replacement or repair of the pump. Shipping costs shall be borne by our company, except as required by law
. Please report the warranty on our service platform http://www.pro-pumpe.de/service.php. We will inform you how to proceed with case-related. Returns please sufcient postage. Unfortunately not prepaid returns can not be accepted because they are ltered out before delivery. Our service we provide in Germany. The warranty does not cover:
l Material wear (sealing rings, impeller wheels, impeller chambers) l Unjustied interventions or changes in the pump l Damages by selffault l Improper servicing and improper use l DRY RUNNIG (Also partially!) of the pump
Moreover, we give no damage compensation for secondary damages!