The M4 is a four-zone, six-source Audio Amplifier/Controller. It serves as the
“brains” of the entire keypad system. The M4 provides audio switching for
six sources and 30W/channel audio power amplifiers for four zones. It also
has connection termination facilities for the controlled whole house system.
PHONE PAGE IN JACK
This jack provides input porting for audio feeds from
door mikes or other forms of phone or doorbell
paging. The jack is programmable by Proficient Editor, to turn on as events, when triggered by the
DOORBELL/STATUS IN Jack.
DOORBELL/STATUS IN 1 & 2 JACKS
These 3.5mm mini phone trigger inputs work in
conjunction with the PHONE PAGE IN jack. When
triggered, the phone inputs can be turned on as
programmed by Proficient Editor. If audio paging is
not required, these 1 & 2 jacks may also be pogrammed
as STATUS inputs for power management of source or
zone components. They accept input levels of 3V to 30V
AC or DC for the trigger ON condition. The voltage level
must drop below 1V AC or DC for the OFF condition.
CONTROL PORT & FIRMWARE UPGRADE SWITCH
3.5mm 4-circuit mini phone jack allows several control functions. All keypad
programming is accomplished via this port using Proficient Editor in conjunction
with the mating Transfer Cable. It also accommodates factory firmware updates
in conjunction with the FIRMWARE UPGRADE OFF/ON Switch. Be sure to leave
this switch in the OFF position at all times, except, as instructed within Proficient Editor, when you are doing a firmware update. Such updates ensure that you can
always have the latest functionality improvements in the field. Another function of
this port is that you can control installed system components with bi-directional
data via touch panels or computers using RS232 protocol.
COMMON IR OUTPUT & HI/LO SWITCH
3.5mm mini phone jack provides a common IR output derived from all of
the zone IR inputs and from keypad initiated IR commands derived from
the internal IR library. High or low IR power output is set by means of the
HI/LO switch
. Set it to the LO setting when driving standard low power
emitters (i.e, Proficient IR single flasher). Set it to the HI position when
driving a high power emitter (i.e, a blaster) for teaching IR commands into
learning remotes. Caution: The HI position will damage or destroy low
power emitters!
RS-232 DATA I/O
Communication port.
EXPANSION PORTS
RJ45 jacks provide for connection
of specialized RS485 controlled
products and for looping to
additional M4 controllers for zone
expansion capability.
CONTACT CLOSURE
Provides a single pole dry relay
contact to activate any device that
can be controlled or triggered by a
switch closure. The closure can be
programmed within Proficient Editor
to be activated by keypad presses,
Command Library IR, or within macros
for Momentary, Toggle and Open/
Close Paired operations. Spring-loaded
terminals accept wire sizes from 28 to 14
AWG. Internal relay contacts are rated at
2A/30V AC or DC.
L & R PRE-OUT JACKS
These RCA jacks provide line level
audio outputs for driving external
power amplifiers for additional rooms
within zones, where needed.
2
Figure 2
M4 Rear Panel Features
KEYPAD ZONE INPUTS
These RJ45 terminals allow for easy
connection of the inter-room wiring
from keypads in the various rooms.
Normally this is accomplished using
CAT5 cable with home-run lengths of
up to 1000'.
L & R SPEAKERS TERMINALS
These 4-circuit plugable screw-down
terminals accept wire sizes from 14 to
28 AWG. They allow quick connection of
the internal amplifiers to stereo pairs of
speakers in the various zone rooms.
3
IR OUT
This 3.5mm mini jack, one for each zone, provides dedicated Zone IR
output initiated from the respective zone inputs. They may control
specific zone components when you want to prevent the control of it
from the other zones.
4
IR OUT JACKS
These 3.5mm mini phone jacks, one for each source, provide
dedicated IR output to specific source components. When a
source is selected on a keypad, IR function commands are
routed directly to that source. This prevents cross-control
interference between two or more sources that have
identical IR commands.
L & R AUDIO IN & LOOP JACKS
These RCA jacks – four for each source – provide audio
signal inputs and buffered loop outputs, for each
source. The buffered outputs can be used to drive local
components or loop the signals to the additional zone
inputs of other M4 controllers when using them for source
expansion.
VCNVC SWITCH
The audio output from the PRE-OUT jacks can
either be controlled by the internal volume
control of the M4 (VC position) or be a fixed
line level output in the no volume control
(NVC position). In either case, the tone control
remains available for room “EQ” settings.
COMMON STATUS OUT PORT
This 3.5mm mini phone jack will go high (+12V DC)
when any zone is turned ON and will go LOW (under 1V
DC) when the last zone is turned OFF. The max. output
of this jack is 100 mA at 9.5V DC.
IR LOOP JACKS
These six 3.5mm mini phone jacks, one for each source, are
provided exclusively for zone expansion capability when
using two or more M4 controllers. They permit the
source IR signals from the added zones to be carried to
the source component emitters.
IEC TYPE AC
Mains receptacle and fuse mates with included AC
power cord. Also houses the rear panel replaceable AC
mains fuse (T5AL 250V for 120V, and T2.5AL 250V for
230V/240V)
5
Page 3
PMKIR Master Keypad
(included with the M4)
MUTE
PWR
Rear View
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
SATCD
TNR1
TNR2
CD2
MP3
BASS
TREB
PMKIR
Master Keypadwith IR Receiver
+ RELAY
– RELAY
+12V
DATA
GND
485 A
485 B
ADDRESS
KEYPAD EXPANSION
Riverside, CA. USA • Made in China
proficientaudio.com
SATCD
MUTE
TNR1
TNR2
PWR
CD2
MP3
BASS
TREB
SATCD
MUTE
TNR1
TNR2
PWR
CD2
MP3
BASS
TREB
1
6
8
PMKIR
(included)
PMKIR
Master Keypad
with IR Receiver
+ RELAY
– RELAY
+12V
DATA
GND
485 A
485 B
ADDRES S
KEYPAD EXPANSION
Riverside, CA. USA • Made in China
proficientaudio.com
234
4
5
7
PMKIR PNK PFK
(included)(optional)(optional)
123
456
789
0
TRKDSC
RDM
RPT
PLAY
ESCINFO
MENUGUIDE
MUTE
PWR
PMKIR PNK
MUTE
PWR
123
456
789
0
TRKDSC
RDM
PMKIR
(included)
SATCD
MUTE
TNR1
TNR2
PWR
SEL
CD2
MP3
BASS
TREB
SATCD
TNR1
TNR2
CD2
MP3
BASS
TREB
GBL
RPT
SATCD
TNR1
TNR2
CD2
MP3
BASS
TREB
(included) (optional)
SATCD
MUTE
TNR1
TNR2
PWR
CD2
MP3
BASS
TREB
SATCD
MUTE
TNR1
TNR2
PWR
CD2
MP3
BASS
TREB
PLAY
ESCINFO
MENUGUIDE
SEL
123
456
789
0
DSC
RDM
RPT
TRK
123
456
789
0
DSC
RDM
RPT
TRK
Single Gang
Double GangTriple Gang
MUTE
PWR
123
456
789
0
TRKDSC
RDM
SATCD
TNR1
TNR2
CD2
MP3
BASS
TREB
GBL
RPT
SATCD
MUTE
TNR1
TNR2
PWR
CD2
MP3
BASS
TREB
123
456
789
0
DISK
RND
RPT
TRK
PMKIR PNK
(included) (optional)
1.7 7"
4.0 7"
PNK Numeric Keypad
(Not included with M4)
123
456
789
0
TRKDSC
RDM
RPT
Rear View
9
KEYPAD EXPANSION
Riverside, CA. USA • Made in China
proficientaudio.com
PNK
Numeric Keypad
123
456
789
0
DSC
RDM
RPT
TRK
PMKIR Master Keypad
(Included with M4)
Rear View
MUTE
PWR
SATCD
TNR1
TNR2
CD2
MP3
BASS
TREB
GBL
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
PMK
Master Keypad
+ RELAY
– RELAY
+12V
DATA
GND
485 A
485 B
ADDRESS
KEYPAD EXPANSION
Riverside, CA. USA • Made in China
proficientaudio.com
SATCD
MUTE
TNR1
TNR2
PWR
CD2
MP3
BASS
TREB
2
1
34
6
7
4
8
5
PMKIR
Master Keypad
with IR Receiver
+ RELAY
– RELAY
+12V
DATA
GND
485 A
485 B
ADDRES S
KEYPAD EXPANSION
Riverside, CA. USA • Made in China
proficientaudio.com
PMKIR PNK PFK
(included) (optional) (optional)
123
456
789
0
TRKDSC
RDM
RPT
PLAY
ESCINFO
MENUGUIDE
MUTE
PWR
SEL
SATCD
TNR1
TNR2
CD2
MP3
BASS
TREB
SATC D
MUTE
TNR1
TNR2
PWR
CD2
MP3
BASS
TREB
PLAY
ESCINFO
MENUGUIDE
SEL
123
456
789
0
DISK
RND
RPT
TRK
1.7 7"
4.0 7"
PNK Numeric Keypad
(Not included with M4)
123
456
789
0
TRKDSC
RDM
RPT
Rear View
9
KEYPAD EXPANSION
Riverside, CA. USA • Made in China
proficientaudio.com
PNK
Numeric Keypad
123
456
789
0
DSC
RDM
RPT
TRK
PMKIR Master Keypad
(included with the M4)
MUTE
PWR
Rear View
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
SATCD
TNR1
TNR2
CD2
MP3
BASS
TREB
PMKIR
Master Keypadwith IR Receiver
+ RELAY
– RELAY
+12V
DATA
GND
485 A
485 B
ADDRESS
KEYPAD EXPANSION
Riverside,CA.USA•MadeinChina
proficientaudio.com
SATCD
MUTE
TNR1
TNR2
PWR
CD2
MP3
BASS
TREB
2
1
3
4
6
7
4
8
5
PFK Function Keypad
(Not included with M4)
PLAY
ESCINFO
MENUGUIDE
Rear View
2
9
SEL
KEYPAD EXPANSION
Riverside, CA. USA • Made in China
proficientaudio.com
PFK
Function Keypad
PLAY
ESCINFO
MENUGUIDE
SEL
PMKIR
Master Keypad
with IR Receiver
+ RELAY
– RELAY
+12V
DATA
GND
485 A
485 B
ADDRES S
KEYPAD EXPANSION
Riverside, CA. USA • Made in China
proficientaudio.com
M4 AUDIO CONTROLLER WITH KEYPAD SYSTEM
SINGLE GANG
DOUBLE GANG
TRIPLE GANG
The Proficient M4 System consists of four subsystems.
First, the keypads themselves can be configured in
many key icon arrangements and placed in a one,
two or three gang set-up to meet virtually any client
requirement. They are connected via convenient
CAT5 cable with home-run lengths of up to 1000'
(305m or longer, if heavier gauge wire is used) to the
centrally located M4 Multi-Zone Audio Amplifier/
Controller located near the controlled equipment.
The M4 contains the “brains” of the system, taking
KEYPAD GANG CONFIGURATIONS
The M4 System comes with four single gang PMKIR
pre-configured keypads, one for each zone as shown
for the single gang version in Figure 3. The cover
plates and the other configurations are optional.
Screw-less “Snap-On” type cover plates are also
key location data from the keypads to trigger the
actual controlling IR, RS232 and RS485 commands
that are passed to all of the installed system
components. Programming is accomplished by the
use of Proficient Editor, a Proficient developed
Windows software system. A fourth item, the
optional Command Interface (sold separately), is an
installer’s tool for learning and teaching special IR
commands that are not included in the Proficient Editor internal library.
accommodated. Each keypad comes with a set of
factory installed “default buttons” plus a good variety
of additional buttons. The default buttons can be easily
changed to meet the needs of the installation.
Figure 4
Figure 5
Figure 6
Keypad Features
The keypads come in four basic modules as shown.
The PMK (13 buttons) and PMKIR (12 buttons) are the
master keypads and must be used in each system.
As mentioned earlier, the M4 comes with a preconfigured version of the PMKIR, for the convenience
of the installer. It is usable right "out of the box" in
The Keypad Gang Configurations
conjunction with a default project that is factory
Figure 3
programmed into the M4. The PMKIR includes an
IR receiver and has one less function button, but is
otherwise identical to the PMK. The PNK Numeric (16
buttons) and PFK Function (14 buttons) keypad modules
can be thought of as “slaves” to the master unit
(they will not work alone), providing additional key
locations for numeric and function commands.
Single Gang Set-Up
1. PMKIR Source/Function Buttons – Six of this set
of eight buttons are programmed as source select
for the M4. When the system is off, all buttons have
a background green color. When a source button is
pressed, it turns to a low-level red color to show that
it is the active source and the system is on.
2. Keypad Expansion Terminal – This 16-pin header
terminal is used to inter-connect the optional numeric
and function keypad modules for expansion as
needed. A 3-connector ribbon cable is packed with
each module for making these connections.
3. Address Switch – A unique hex address must be
set for each master keypad when connected on a
common bus within a single zone. Unique addresses
are not required zone-to-zone. It provides up to 16
addresses (0 to F).
4. Snap Tabs – These tabs hold the decorator style
insert panel to the metal mounting plate and are
easily released for custom changing of the buttons.
5. Mounting Plate – Standard plate allows the
keypad module to be attached to standard in-wall
J-Boxes using the two screws provided. Allows
attachment of standard decorator type cover plates
(also screw-less snap-on plates).
6. IR Receiver Lens – Version PMKIR includes
Proficient’s exclusive ANS IR receiver, built-in. It allows
the use of a handheld remote for control of system
components.
7. Connection Terminals – for CAT5 home-run
termination. + Relay and – Relay - for future use.
+12V – Powers the keypad, including the internal IR
receiver on model PMKIR. Includes reverse voltage
protection. Data – Sends IR control signals for
control of system components. GND – Return for
power, IR signal and data. 485 A / 485 B – Balanced,
bi-directional system communications data.
8. Function Buttons
– These lower four buttons (can
be programmed for any function except source select.)
76
Double Gang Set-Up
1. PMKIR Source/Function Buttons – Six of this set
of eight buttons are programmed as source select
for the M4. When the system is off, all buttons have
a background green color. When a source button is
pressed, it turns to a low-level red color to show that
it is the active source and the system is on.
2. Keypad Expansion Terminal – This 16-pin header
terminal is used to inter-connect the optional numeric
and function keypad modules for expansion as
needed. A 3-connector ribbon cable is packed with
each module for making these connections.
3. Address Switch – A unique hex address must be
set for each master keypad when connected on a
common bus within a single zone. Unique addresses
are not required zone-to-zone. It provides up to 16
addresses (0 to F).
4. Snap Tabs – These tabs hold the decorator style
insert panel to the metal mounting plate and are
easily released for custom changing of the buttons.
5. Mounting Plate
keypad module to be attached to standard in-wall
– Standard plate allows the
J-Boxes using the two screws provided. Allows
attachment of standard decorator type cover plates
(also screw-less snap-on plates).
6. IR Receiver Lens – Version PMKIR includes
Proficient’s exclusive ANS IR receiver, built-in. It allows
the use of a handheld remote for control of system
components.
7. Connection Terminals – for CAT5 home-run
termination. +Relay and – Relay - for future use. +12V – Powers the keypad, including the internal IR
receiver on model PMKIR. Includes reverse voltage
protection. Data – Sends IR control signals for
control of system components. GND – Return for
power, IR signal and data. 485 A / 485 B – Balanced,
bi-directional system communications data.
8. Function Buttons
– These lower four buttons (can
be programmed for any function except source select.
9. Numeric and Function Buttons
– Require
programming via Proficient Editor. All buttons glow
background green and can be configured to go off
after a set time, or stay on via Proficient Editor.
8
Triple Gang Set-Up
1. PMKIR Source/Function Buttons – Six of this set
of eight buttons are programmed as source select
for the M4. When the system is off, all buttons have
a background green color. When a source button is
pressed, it turns to a low-level red color to show that
it is the active source and the system is on.
2. Keypad Expansion Terminal – This 16-pin header
terminal is used to inter-connect the optional numeric
and function keypad modules for expansion as
needed. A 3-connector ribbon cable is packed with
each module for making these connections.
3. Address Switch – A unique hex address must be
set for each master keypad when connected on a
common bus within a single zone. Unique addresses
are not required zone-to-zone. It provides up to 16
addresses (0 to F).
4. Snap Tabs – These tabs hold the decorator style
insert panel to the metal mounting plate and are
easily released for custom changing of the buttons.
5. Mounting Plate
keypad module to be attached to standard in-wall
– Standard plate allows the
J-Boxes using the two screws provided. Allows
attachment of standard decorator type cover plates
(also screwless snap-on plates).
6. IR Receiver Lens – Version PMKIR includes
Proficient’s exclusive ANS IR receiver, built-in. It allows
the use of a handheld remote for control of system
components.
7. Connection Terminals – for CAT5 home-run
termination. +Relay and – Relay - for future use. +12V – Powers the keypad, including the internal IR
receiver on model PMKIR. Includes reverse voltage
protection. Data – Sends IR control signals for
control of system components. GND – Return for
power, IR signal and data. 485 A / 485 B – Balanced,
bi-directional system communications data.
8. Function Buttons
– These lower four buttons (can
be programmed for any function except source select.
9. Numeric and Function Buttons
– Require
programming via Proficient Editor. All buttons glow
background green and can be configured to go off
after a set time, or stay on via Proficient Editor.
9
Page 4
SYSTEM CONNECTIONS AND CONFIGURATION
RS232
PHONE (PAGE IN)
DOORBELL / STATUS IN
1
2
CONTROL
PORT
FIRMWARE
UPGRADE
OFF ON
COMMON
IR OUT
LO
HI
STATUS OUT:
0 to +12V
120V 60Hz 1.8A ~
FUSE: T5AL 250V
DATA I/O
CONTACT CLOSURE
EXPANSION PORTS
COMMON
M4
SOURCE 1
LOOP
OUT
IR
LOOP
LR
INPUTS
SOURCE 2
LOOP
OUT
IR
LOOP
LR
INPUTS
SOURCE 3
LOOP
OUT
IR
LOOP
LR
INPUTS
SOURCE 4
LOOP
OUT
IR
LOOP
LR
INPUTS
SOURCE 5
LOOP
OUT
IR
LOOP
LR
INPUTS
SOURCE 6
LOOP
OUT
IR
LOOP
LR
INPUTS
SPKRS
L
R
+
+–
–
ZONE 4
LR
PRE-OUT
VC
NVC
KEYPAD
IR OUT
Riverside, CA. USA
Made in Taiwan
SPKRS
L
R
+
+ –
–
ZONE 3
LR
PRE-OUT
VC
NVC
KEYPAD
IR OUT
SPKRS
L
R
+
+ –
–
ZONE 2
LR
PRE-OUT
VC
NVC
KEYPAD
IR OUT
SPKRS
L
R
+
+ –
–
ZONE 1
LR
PRE-OUT
VC
NVC
KEYPAD
IR OUT
To
Zone 1
Keypad Jack
CAT5 Cable Carries
RS485 Control, IR Signal
and Keypad Power
From Doorbell Trigger
To Source 1
Inputs
L / R
IR Out from Source 1
IR Out from Source 2
IR Out from Source 3
IR Out from Source 4
TUNER 2
TUNER 1
SATELLITE
CD PLAYER
Speaker Feeds to Each Zone
To Source 2
Inputs
L R
To Source 3
Inputs
L R
To Source 4
Inputs
L R
IR Out from Source 5
CD PLAYER 2
To Source 5
Inputs
L R
IR Out from Source 6
MP3 PLAYER
To Source 6
Inputs
L R
IR Flasher
Zone 1
PMKIR
Keypad
SATCD
MUTE
TNR1
TNR2
PWR
CD2
MP3
BASS
TREB
MUTE
PWR
SATCD
TNR1
TNR2
CD2
MP3
BASS
TREB
SATCD
MUTE
TNR1
TNR2
PWR
CD2
MP3
BASS
TREB
To
Zone 2
Keypad Jack
Zone 2
PMKIR
Keypad
SATCD
MUTE
TNR1
TNR2
PWR
CD2
MP3
BASS
TREB
MUTE
PWR
SATCD
TNR1
TNR2
CD2
MP3
BASS
TREB
SATCD
MUTE
TNR1
TNR2
PWR
CD2
MP3
BASS
TREB
To
Zone 3
Keypad Jack
Zone 3
PMKIR
Keypad
SATCD
MUTE
TNR1
TNR2
PWR
CD2
MP3
BASS
TREB
MUTE
PWR
SATCD
TNR1
TNR2
CD2
MP3
BASS
TREB
SATCD
MUTE
TNR1
TNR2
PWR
CD2
MP3
BASS
TREB
To
Zone 4
Keypad Jack
Zone 4
PMKIR
Keypad
SATCD
MUTE
TNR1
TNR2
PWR
CD2
MP3
BASS
TREB
MUTE
PWR
SATCD
TNR1
TNR2
CD2
MP3
BASS
TREB
SATCD
MUTE
TNR1
TNR2
PWR
CD2
MP3
BASS
TREB
PMKIRMasterKeypad
(included with the M4)
MUTE
PWR
RearView
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
SATCD
TNR1
TNR2
CD2
MP3
BASS
TREB
PMKIR
Master Keypadwith IR Receiver
+ RELAY
– RELAY
+12V
DATA
GND
485 A
485 B
ADDRESS
KEYPAD EXPANSION
Riverside, CA. USA • Made in China
proficientaudio.com
SATCD
MUTE
TNR1
TNR2
PWR
CD2
MP3
BASS
TREB
SATCD
MUTE
TNR1
TNR2
PWR
CD2
MP3
BASS
TREB
1
6
8
PMKIR
(included)
PMKIR
Master Keypadwith IR Receiver
+ RELAY
– RELAY
+12V
DATA
GND
485 A
485 B
ADDRESS
KEYPAD EXPANSION
Riverside,CA. USA • Made in China
proficientaudio.com
234
4
5
7
PMKIR PNK PFK
(included)(optional)(optional)
123
456
789
0
TRKDSC
RDM
RPT
PLAY
ESCINFO
MENUGUIDE
MUTE
PWR
PMKIR PNK
MUTE
PWR
123
456
789
0
TRKDSC
RDM
PMKIR
(included)
SATCD
MUTE
TNR1
TNR2
PWR
SEL
CD2
MP3
BASS
TREB
SATCD
TNR1
TNR2
CD2
MP3
BASS
TREB
GBL
RPT
SATCD
TNR1
TNR2
CD2
MP3
BASS
TREB
(included) (optional)
SATCD
MUTE
TNR1
TNR2
PWR
CD2
MP3
BASS
TREB
SATCD
MUTE
TNR1
TNR2
PWR
CD2
MP3
BASS
TREB
PLAY
ESCINFO
MENUGUIDE
SEL
123
456
789
0
DSC
RDM
RPT
TRK
123
456
789
0
DSC
RDM
RPT
TRK
Single Gang
Double GangTriple Gang
MUTE
PWR
123
456
789
0
TRKDSC
RDM
SATCD
TNR1
TNR2
CD2
MP3
BASS
TREB
GBL
RPT
SATCD
MUTE
TNR1
TNR2
PWR
CD2
MP3
BASS
TREB
123
456
789
0
DISK
RND
RPT
TRK
PMKIR PNK
(included) (optional)
1.77"
4.07"
PNKNumericKeypad
(Not included with M4)
123
456
789
0
TRKDSC
RDM
RPT
RearView
9
KEYPAD EXPANSION
Riverside,CA.USA•MadeinChina
proficientaudio.com
PNK
Numeric Keypad
123
456
789
0
DSC
RDM
RPT
TRK
PMKIRMasterKeypad
(Included with M4)
RearView
MUTE
PWR
SATCD
TNR1
TNR2
CD2
MP3
BASS
TREB
GBL
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
PMK
Master Keypad
+ RELAY
– RELAY
+12V
DATA
GND
485 A
485 B
ADDRESS
KEYPAD EXPANSION
Riverside, CA. USA • Made in China
proficientaudio.com
SATCD
MUTE
TNR1
TNR2
PWR
CD2
MP3
BASS
TREB
2
1
34
6
7
4
8
5
PMKIR
Master Keypadwith IR Receiver
+ RELAY
– RELAY
+12V
DATA
GND
485 A
485 B
ADDRESS
KEYPAD EXPANSION
Riverside,CA.USA•MadeinChina
proficientaudio.com
PMKIR PNK PFK
(included) (optional) (optional)
123
456
789
0
TRKDSC
RDM
RPT
PLAY
ESCINFO
MENUGUIDE
MUTE
PWR
SEL
SATCD
TNR1
TNR2
CD2
MP3
BASS
TREB
SATCD
MUTE
TNR1
TNR2
PWR
CD2
MP3
BASS
TREB
PLAY
ESCINFO
MENUGUIDE
SEL
123
456
789
0
DISK
RND
RPT
TRK
1.77"
4.07"
PNKNumericKeypad
(Not included with M4)
123
456
789
0
TRKDSC
RDM
RPT
RearView
9
KEYPAD EXPANSION
Riverside,CA.USA•MadeinChina
proficientaudio.com
PNK
Numeric Keypad
123
456
789
0
DSC
RDM
RPT
TRK
PMKIRMasterKeypad
(included with the M4)
MUTE
PWR
RearView
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
SATCD
TNR1
TNR2
CD2
MP3
BASS
TREB
PMKIR
Master Keypadwith IR Receiver
+ RELAY
– RELAY
+12V
DATA
GND
485 A
485 B
ADDRESS
KEYPAD EXPANSION
Riverside,CA.USA•MadeinChina
proficientaudio.com
SATCD
MUTE
TNR1
TNR2
PWR
CD2
MP3
BASS
TREB
2
1
3
4
6
7
4
8
5
PFK FunctionKeypad
(Not included with M4)
PLAY
ESCINFO
MENUGUIDE
RearView
2
9
SEL
KEYPAD EXPANSION
Riverside,CA.USA•MadeinChina
proficientaudio.com
PFK
Function Keypad
PLAY
ESCINFO
MENUGUIDE
SEL
PMKIR
Master Keypadwith IR Receiver
+ RELAY
– RELAY
+12V
DATA
GND
485 A
485 B
ADDRESS
KEYPAD EXPANSION
Riverside,CA.USA•MadeinChina
proficientaudio.com
SPKRS
L
R
+
+–
–
ZONE 4
LR
PRE-OUT
VC
NVC
KEYPAD
IR OUT
L
+
L
-
R
+
R
-
A TYPICAL M4 KEYPAD CONTROLLED SYSTEM
A TYPICAL M4 INSTALLATION
Factory Default System
As mentioned earlier, the M4 comes with a set of four
pre-configured PMKIR keypads, one for each zone. In
addition, the M4 is pre-programmed at the factory
with a default project so that the entire system will
function “right out of the box.” The installer can use
this default as a base on which to build customized
projects. The default project has the following
functionality: (Refer to Figures 3 & 7).
1. Six Source keys: TNR1, TNR2, SAT, CD, CD2, MP3
2. Six Function keys: BASS, TREB, MUTE, PWR, VOL UP,
VOL DOWN
3. The six Source keys are set as Zone ON keys and
are programmed to select the M4 rear panel Audio
Source inputs as follows:
TNR1 = Audio Source 1, TNR2 = Audio Source 2,
SAT = Audio Source 3, CD = Audio Source 4, CD2 =
Audio Source 5, MP3 = Audio Source 6. In addition,
a Mute Off command is programmed under each
Source key.
4. The six Function keys are programmed as follows:
: Volume Up command. Also serves as Bass or
Treble Up after first pressing BASS or TREB keys.
: Volume Down command. Also serves as Bass
or Treble Down after first pressing BASS or TREB keys.
NOTE:
selected Source button will blink at a medium rate,
to indicate the tone setting mode. The tone setting
mode is defeated by one press of any button other
than the Tone and Volume buttons.
MUTE: Set for Internal Preamp Muting. Toggles
ON/OFF. Pressing Source and Volume buttons also
un-mutes. During Mute, selected source key blinks
slowly.
PWR: Set as Zone Power OFF. Will NOT turn the zone
ON. Press and Hold for two seconds turns all zones
OFF (Whole House).
While in the Treble or Bass tone modes, the
Whole House/Party Mode
5. All zones are set for Whole House/Party Mode
capability Whole House/Party Mode: Forces all zones
to the same source and allows volume and mute
functions to operate all zones in unison.
- To engage Whole House/Party Mode, press and
hold a desired Source button for longer than two
seconds. During press and hold, source button
blinks rapidly (busy).
- Release button when blinking stops. Source
button then turns Amber in color, indicating
system is now in Whole House/Party Mode.
- Source selection, Volume Control and Mute
functions will now operate in all zones from the
initiating zone only.
- To transfer Whole House/Party Mode control to
another zone, above steps are repeated from the
desired zone.
- To cancel Whole House/Party Mode, press and
hold a Source button from the initiating zone for
longer than two seconds (until blinking stops).
NOTE:
Zones other than the initiating zone will have
red active Source buttons and will operate as normal
independent zones.
6. Priority is set to ON for all zones. This means
that commands from any keypad in any zone will
execute, regardless of previous command executions
in other zones.
7. When a zone is first turned on, the volume will be
at a default medium background level. After that, it
will come on at the last volume used prior to zone
turn OFF.
Figure 7
Perhaps the best way to become familiar with the
M4/keypad system is to show its application in a
typical installation. Figure 7 shows the four PMKIR
keypads (included) controlling the M4 and related
source components in a four-zone application
NOTE:
The system in Figure 7 is given to illustrate
the basics on how to configure and program
a system, not to show all aspects of such an
installation. For instance, for simplicity, the speakers
in each zone are not shown in Figure 7, even though
such components would be required for a complete
working system.
NOTE:
Maximum recommended lead length for the
keypads with CAT5 cable is 1000' (305m).
The recommended steps to install such a system
would be as follows:
1. Pull all wiring for the keypads, speakers, etc., from
the various zone rooms (home runs) to a central
equipment area.
2. Set up and make all the necessary audio
connections from the source components to the
M4, the amplifiers to speakers in rooms, etc.
3. Make sure all system components function first,
with their own remote controls, before configuring
the keypads.
4. Flasher placement: Locate each source
component’s IR Sensor window. Place emitters on
each of the source components and plug them into
the corresponding Source IR Outputs on the M4.
Proficient Audio Systems warrants to the original retail purchaser only that this product will
be free from defects in materials and workmanship for a period of two years, provided the
speaker was purchased from a Proficient Audio Systems Authorized Dealer.
Defective products must be shipped, prepaid and insured, together with proof of purchase,
to the Proficient Audio Systems Authorized Dealer from whom they were purchased, or to
Proficient Audio Systems at the address listed on this installation instruction manual. Freight
collect shipments will be refused. It is preferable to ship this product in the original shipping
container to lessen the chance of transit damage. In any case, the risk of loss or damage in transit
is to be borne by the purchaser.
If, upon examination at the Factory or Prof icient Audio Systems Authorized Dealer, it is
determined that the unit was defec tive in materials or workmanship at any time during this
warranty period, Proficient Audio Systems or the Proficient Audio Systems Authorized Dealer
will, at its option, repair or replace this product at no additional charge, except as set for th
below. If this model is no longer available and can not be repaired effec tively, Proficient Audio
Systems, at its sole option, may replace the unit with a current model of equal or greater value.
In some cases where a new model is substituted, a modification to the mounting surface may
be required. If mounting surface modif ication is required, Proficient Audio Systems assumes
no responsibilit y or liability for such modification. All replaced parts and produc t become the
proper ty of Proficient Audio Systems. Products replaced or repaired under this Warranty will
be returned to the original retail purchaser, within a reasonable time, freight prepaid.
This Warranty does not include service or parts to repair damage caused by accident, disaster,
misuse, abuse, negligence, inadequate packing or shipping procedures, commercial use, voltage inputs in excess of the rated maximum of the unit, or service, repair or modification of the
product which has not been authorized or approved by Proficient Audio Systems. This Warranty
also excludes normal cosmetic deterioration caused by environmental conditions. This warranty
will be void if the Serial Number on the product has been removed, tampered with or defaced.
This Warranty is in lieu of all other expressed warranties. If the produc t is defective in materials
or workmanship as warranted above, the purchaser’s sole remedy shall be repair or replacement
as provided above. In no event will Proficient Audio Systems be liable for any incidental or consequential damages arising out of the use or inability to use the product, even if Proficient Audio
Systems, or a Proficient Audio Systems Authorized Dealer has been advised of the possibility of
such damages, or for any claim by any other par ty. Some states do not allow the exclusion or
limitation of consequential damages, so the above limitation and exclusion may not apply.
All implied warranties on the product are limited to the duration of this expressed Warranty.
Some states do not allow limitation on the length of an implied warranty. If the original retail
purchaser resides in such a state, this limitation does not apply.
For technical inquiries, please call 877.888.9004 or email us at
techsupport@proficientaudio.com. We are available to assist you every
weekday, except holidays, between the hours of 7:00 a.m. and 5:00 p.m. PST.
1301-72400 (rev1)
1. The keypads have a pre-installed set of buttons in
place. These may not match the source and function
arrangements you need or desire. To change them,
release the tabs on each end of the keypad, Figure 8,
and remove the decorator insert panel, exposing the
key buttons, Figure 9.
2. Starting with the Zone 1 PMKIR (master keypad),
and using the extra buttons supplied, if needed,
move and place the source and function buttons in
the arrangement you want. See Figure 10. When you
Figure 11 Ribbon Cable – PMKIR Right
NOTE: The numeric and function keypads will not
work on their own. They must be connected to a
master keypad using the 3-connector ribbon cable
supplied (included with each model). The cable is
symmetrical so it can be connected with the red
striped side up or down, to best fit the configuration.
Figure 11
shows it connected so that the PMKIR
master keypad will be to the right of the PNK numeric
and PFK function keypads when mounted, whereas
Figure 12
places the PMKIR to the left.
NOTE 1: If you want to use RJ45 connectors for
connecting the CAT5 cable to the keypads, you can do
so by using the Proficient model RJA-1.1 RJ45-to-Wire Pin
Adapters. See Figure 13 and Figure 14. Simply insert the RJA-1.1 pins into the keypad’s connection terminals and
snap the levers in place. Be sure to orient them correctly
as shown.
finish the arrangement, replace the decorator insert
panel over the buttons, being careful to see that the
buttons align correctly with the panel openings.
Figure 12 Ribbon Cable – PMKIR Left
Figure 15
Using CAT5 Cable to Connect PMKIR Keypads to M4
Press the panel down until the tabs “snap” into place.
3. Repeat these steps for each of the other zone
master keypads. Each zone can have its own unique
configuration… but, it is best to keep them as similar
as possible to simplify programming and operation.
4. In the same way, configure the buttons on the
numeric and function keypads (not included) that
you may chose to use in some zones.
5. Connect all keypads to their assigned zones on
the M4 as shown in Figure 7. Be sure to strip then
Figure 13 RJA-1.1 Adapter
connect the various colored CAT5 leads to the correct
terminals on each keypad end. Refer to Figure 15.
Figure 8 Release Tab
Figure 9 Remove Decorator Insert Panel
Figure 10 Moving and Placing Buttons
1514
Figure 14 RJA-1.1 Attached to Keypad and CAT5
16
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.