Professional Water Systems 268 Homeowner's Manual

PROFESSIONAL WATER SYSTEMS Homeowner’s
Manual! !
! ! ! ! ! ! ! ! ! ! ! ! ! !
Model 268 Co-current Conditioner
!
!
! ! ! ! ! ! ! ! ! ! ! ! ! !
! ! ! ! ! ! ! ! ! !
!
! ! ! !
Professional!Water!Systems,!In c.!
1‐800‐432‐6897!•!www.professionalwatersystems.com ! !
!
The!Home!Water!Treatment!System! by!Professional+Water+Systems!
This! system! is! one! of! the! most! advanced! water! conditioning!systems!available!today .!!It!!is!designed! to! provide! you! with! superior! performance! and! efficiency,! together! with! state‐of‐the‐art! information! and! contr ol! systems.! ! Most! of! the! settings! on! this! syst em! require! adju stment! by! a! water! conditioning! professional! to! ensure! optimal! perform ance.! ! This! easy! to! follow! Homeowner’s+ Manual! is! designed! to! prov ide! you! with! the! basic! operational! information.! ! For! all! other! system! questions! or! concerns,! please& contact& Professional& Water&Systems.!
!
Water!Conditioning!&!Regeneration!
The! media! inside!this!system! uses! salt!to! condition! the! water.! !After! the!media! has!used! all!of! its!own! salt,! the! salt! must! be! replaced.! ! This! replacement! salt!comes!from! the!brine!tank.! ! The!process!of! the! salt!replacement!from!the!brine!tank!to! the!med ia!is! called!the®eneration!step.!
Regeneration! normally! takes! place! automatically! at! night! so! that! it! does! not! interfere! with! normal! use! of! conditioned! water.! ! This! val ve! has! the!ability! to!count! the! gallons!being! used! and! to! calculate! when! the! system! should! be! regenerated.! ! Therefore,! the! system! will! not! regenerate! until! it! is! necessary.! ! In! or der! for! regeneration! to! proceed! properly,! there! must! be! salt!in!the!brine!tank.! !
!
! !
Level!1!Programmin g!
This! water! conditione r! has! been! designed! to! continuously! monitor! your! water! supply! and! how! you! use! it! in! your! home.!!Level! I! program! parameters! are! those! that! can! be! accessed! by! the! end!user!by!pressing!the!SET!button.!They!include:!
Time!of!Day!
Day!of!Week!
Time!of!Regeneration!
!
Setting!Time!of!Day!
Upon! initial! star t! up! of! the! controller,! the! time! of! day!must!be!set.!!The!words!Time!of!Day!will!scroll! across! the! b anner! display! and! the! currently! programmed! time!of! day!will!be! flashing! below.! ! If! the! time! is! not! flashing,! press! the! SET! button.! ! To! change! the! time! of! day,! press! and! hold! the! UP! or! DOWN! button! until! the! correct! time! is! displaye d.!! Press!the!SET!button!to!accept!the!selection.!
!
NOTE:!!When!th e!controller!is!set!for!a!twelve‐hour! clock,! a! PM! indicator! will! illuminate! when! t he! displaye d!time!is!in!the!PM!hours.!!There!is!no!AM! indicator.! ! ! ! ! !
!
Setting!the!Day!of!Week!
After! setting! t he! Tim e! of! Day,! the! banner! display! will!show! the!word!Day!followed! by!an!abbreviated! day!of!the!week.!
SU!=!Sunday! ! TH!=!Thursday! MO!=!Monday! ! FR!=!Friday!
TU!=!Tuesday! ! SA!=!Saturday! Use! th e!UP!or! DOWN!arrow!buttons! to!change!the! flashing! day! of! week.! ! Press! the! SET! button! when! the!current!day!of!week!is!flashing.!
!
Setting!Regeneration!Time!
The!Regeneration!Time!is!the!setting!that!allows! the!programming!to!select!the!time!of!day!when! regeneration!should!occur.!!The!words! Regeneration!Time!will!s croll!through!the!banner! display.!!To!change!the!regeneration!time,!press!and! hold!the!UP!or!DOWN!button!until!the!desired! regeneration!time!is!displayed.!!Press!SET!to!lock! this!time!into!memory.! !
Loading...