Thank you for purchasing Digital’s TFT type color display panel, the 'FP2600-T41'
(hereafter referred to as the FP unit).
The FP unit is a TFT type color liquid crystal display monitor for IBM-PC compatible
personal computers (SVGA mode).
Please read this manual completely to insure the correct use and complete understanding of the FP unit's functions. The FP's analog interface is designed for use with
standard VGA mode. Please be aware that this unit may not be able to be connected
with nonstandard VGA modes. For more details, please refer to this manual's "PC
Connectivity Notes" section.
The term FP2600-T41 refers to the following unit:
FP2600-T41-24V(AC 24V type)
<Note>
It is forbidden to copy the contents of this manual, in whole or in part, except for the
user's personal use, without the express permission of the Digital Electronics Corporation of Japan.
2) The information provided in this manual is subject to change without notice.
3) This manual has been written with care and attention to detail; however, should you
find any errors or omissions, please contact Digital Electronics and inform them of
your findings.
4) Please be aware that Digital Electronics is not responsible for any damages resulting
from the use of our products, regardless of article 3 above.
5) Specifications set out in this manual are for overseas products only , and, as a result,
some differences may exist between the specfications given here and the Japanese
ones.
All Company/Manufacturer names used in this manual are the registered trademarks of
their respective companies.
This manual describes safety instructions for correct use of the FP unit. Please keep this
manual close at hand, and refer to it when necessary .
The following symbols are used throughout this manual to ensure the safe use of the FP
unit. Please make sure to follow all instructions given since they explain important safety
points.
This mark warns of a situation that could either seriously
W arning
Caution
injure a person or lead to death if the instruction is ignored
and/or the unit is used incorrectly.
This mark warns of a situation that could either injure a
person or damage property if the instruction is ignored and/
or the unit is used incorrectly.
Other Symbols Used In This Manual
The list below describes the symbols used in this manual.
Explains a situation that requires a moderate amount of caution.
Indicates a word or phrase that has an additional explanation.
*1
1),2)
A reference point. Describes the word or phrase marked by the asterisk (*) and the corresponding number.
Reference pages on related topics.
Operational steps. Please follow these numbered steps in order to
perform the desired operation.
iiFP2600-T41 User Manual
W arning
Safety Instructions
For the safe use of this unit, be sure to follow these guidelines:
Because of the ever present danger of electrical shock, be sure to unplug the power cable
from the FP unit before plugging the cable's other end into the wall.
Do not use power in excess of the unit's specified voltage range since it may cause a fire or
electric shock.
Because the FP unit contains high voltage parts, an electric shock can occur when disassembling the unit. Therefore, please be sure to always unplug the unit before disassembling
it.
Do not modify the FP unit in any way , since it may cause a fire or electric shock.
When changing the backlight, be sure to turn off the unit's power first, in order to prevent an
electric shock.
Do not use touch panel keys to perform life-threatening or vitally important safety functions.
Use separate mechanical switches for such keys.
If substantial amounts of metallic dust, water or liquids enter the FP unit, turn off the power
supply immediately , unplug the power cord, and contact your local FP distributor.
When installing the FP unit, be sure to follow the instructions given in “Chapter 3. Installation
and Wiring," to insure it is done correctly .
Do not use the FP in an environment with flammable gas since it may cause an explosion.
FP2600-T41 User Manualiii
Caution
Safety Instructions
For the correct use of this unit, please follow these guidelines:
Do not press the screen's touch surface too strongly with either your finger or a hard
object, since the touch surface may be damaged.
When the surface of the display screen becomes dirty or smudged, clean the display with
a cloth soaked in a neutral detergent. Do not use paint thinner or organic solvent.
Do not press on the touch panel's face with sharp objects, such as a mechanical pencil or
screwdriver, since it might damage the LCD panel.
A void using or storing the FP in direct sunlight, excessively dusty or dirty environments, or
where chemicals or their vapors are present in the air.
A void restricting the FP's natural ventilation, or storing and using the FP in an environment
that will increase the FP's internal temperature.
Please avoid using the FP in areas where sudden, large changes in temperature may occur .
These changes can cause condensation to form inside the unit, possibly causing an accident.
Notes on the FP's Liquid Crystal Display (LCD)
The FP's LCD contains a strong irritant. If the panel is ever cracked and the LCD's liquid
contacts your skin, be sure to wash it with running water for at least 15 minutes. If any of
this liquid should enter your eye, be sure to flush the eye with running water for more than
15 minutes, and see a doctor immediately .
The current brightness of the LCD screen will depend on the screen's current display and
the LCD's contrast adjustment. Any brightness variations that result are normal for LCD
displays.
There are minute grid-points on the LCD surface. These points are not defects.
Sometimes crosstalk (shadows appearing on extended display lines) will appear on the
display . This phenomenon is a common attribute of LCD's and is not a defect.
The displayed color will look different when viewed from an angle outside the specified
view angle. This is also normal.
Displaying a single screen image for long periods of time can cause an afterimage to
remain. To correct this, turn the unit OFF for 5 or 10 minutes, then ON again. This
phenomenon is a common attribute of the LCD's, and not a defect. T o prevent this effect,
you can:
- use the Display OFF feature, if the same image is to be displayed
for a long period of time.
- change the screen display periodically to prevent the displaying of a
single image for a long period of time.
6-3Replacing the Backlight ...........................................................................................6-3
INDEX.............................................................................................i - iv
viFP2600-T41 User Manual
When Connecting to a PC
The FP unit's analog interface is designed for standard SVGA mode. The number of dots
(pixels) displayed are as follows:
Siz eH Sync.V Sync.Dot Clock Ra nge
800 X 60035.156± 1 K Hz56±1 Hz36.000MHz± 1%
800 X 60037.879± 1 K Hz60±1 Hz40.000MHz± 1%
640 X 48031.469± 1 K Hz60±1 Hz25.175MHz± 1%
640 X 48035.000± 1 K Hz66±1 Hz30.240MHz± 1%
640 X 48037.861± 1 K Hz72±1 Hz31.500MHz± 1%
640 X 40024.827± 1 K Hz56±1 Hz21.053MHz± 1%
640 X 40031.469± 1 K Hz70±1 Hz25.175MHz± 1%
640 X 35031.469± 1 K Hz70±1 Hz25.175MHz± 1%
720 X 40031.469± 1 K Hz70±1 Hz28.322MHz± 1%
720 X 35031.469± 1 K Hz70±1 Hz28.322MHz± 1%
• With vertical 350 pixels, 400 pixels, including 50 pixels at the top and at the
bottom of the screen will be enlarged and displayed at 600 pixels (1.5 times).
Some types of VGA equipment may not be within the ranges specified above, and, therefore,
cannot be connected to the FP.
Also, if the user changes his PC's VGA board, there is the possiblity that the new board
may not be able to be connected to the FP.
FP2600-T41 User Manualvii
FP2600-T41 Features
The features of the FP2600-T41 are as follows.
High Quality TFT Color LCD Display
This unit is equipped with a 12.1 inch TFT type color LCD. Its superior brightness and
wide viewing angle, not found in ordinary laptop type TFT LCD's, widens your scope of
applications.
The screen's maximum resolution is 800 x 600 pixels, and can display 260,000 colors.
Easy Installation In User’s Cabinets and Panels
The FP2600-T41's slim, lightweight, and compact design make installation a snap. It
was designed specifically for use as your IA (Industrial Automation) or OA (Office
Automation) system monitor. The flat, front panel provides protection equivalent to the
rigorous IP65F standard, and, even without its optional protective cover, the front panel
is highly resistant to both water and dust.
Panel can be used as a VGA Display
Since the FP2600-T41 is equipped with an analog RGB interface, it can be connected
to any PC with standard VGA/SVGA mode. (The PC's clock frequency , however,
must be within the standard range)
Easy to use Built In Touch Panel
The FP2600-T41's built in touch panel is standard equipment, allowing touch panel data
to be output to a host PC via input/output commands and an RS-232C cable and USB
cable. This is perfect for systems requiring both touch panel operation and data monitoring.
viiiFP2600-T41 User Manual
Package Contents
The FP's packing box contains the items listed below . Please check to be sure each is
included and is not damaged.
FP unit (FP2600-T41-24V)
These items have all been carefully packed with special attention to product quality .
However, should you find anything damaged or missing, please contact your local
distributor immediately for prompt service.
FP2600-T41 User Manualix
UL/c-UL (CSA) Application Notes
The FP2600-T41-24V is a UL/c-UL (CSA) listed product. (UL file No.E182139)
This unit conforms as a product to the following standards:
This UL508 Industrial Control Equipment
This UL1604 Electrical Equipment for use in Class 1 & 2 - Division 2, or Class 3
Hazardous Locations.
This CAN/CSA-C22.2, No.1010-1
MSUREMENT AND CONTROL EQUIPMENT
(Safety requirements for electrical equipment for mesurement and laboratory use)
FP2600-T41-24V(UL Registration Model: 30B0003-02)
<Cautions>
The FP must be used as a built-in component of an end-use product.
This unit should be installed in the front face of a metal panel.
If this unit is installed so as to cool itself naturally , be sure to install it in a vertical panel.
Also, be sure that the FP unit is mounted at least 100 mm away from any adjacent
structures or equipment. If these requirements are not met, the heat generated by the FP
unit's internal components may cause the unit to fail to meet UL/c-UL standard
requirements.
UL1604 Conditions of Acceptability and Handling Cautions:
1. Power, input and output (I/O) wiring must be in accordance with Class I,
Division 2 wiring methods-Article 501-4(b) of the National Electrical Code, NFP A
70 within the United States, and in accordance with Section 18-152 of the Canadian
Electrical Code for units installed within Canada.
2. Suitable for use in Class I, Division 2, Groups A, B, C and D, Hazardous Locations.
3. W ARNING: Explosion hazard - substitution of components may impair suitability for
Class I, Division 2.
4. WARNING: Explosion hazard - when in hazardous locations, turn power OFF before
replacing or wiring modules.
5. WARNING: Explosion hazard - do not disconnect equipment unless power has been
switched OFF , or the area is known to be non-hazardous.
CE Marking Notes
The FP2600-T41-24V is a CE marked product that conforms to EMC directives
EN55011 class A and EN61000-6-2.
*For detailed CE marking information, please contact your local FP distributor.
xFP2600-T41 User Manual
Chapter 1
Introduction
1. Connecting the FP to a PC
2. Optional Equipment
The following diagram illustrates the connection between the FP unit and a PC.
All optional items listed below are products of Digital Electronics Corporation.
Introduction
Interface
Maintenance
Parts
Optional
Parts
Item
SIO CableFP61V -IS00-O
RGB Ca ble
USB CableFP-US 00
Backlight
Bulbs
Installation
Brackets
Rubber
Gasket
Cov er
Sheet
(Hard type)
Mouse
Em ulat or V 2
ModelDescription
FP-CV00
FP-CV01
PS 600-B U00Replacem ent B ackli ght bulbs .
GP070-AT01M etal installat ion brac kets for FP 2600-T41
GP-WP10-MS
PSL-DF00
PL-TD000Mous e E m ulator software for FP.*
Serial i nterface cable (5m) used for touch
panel data t rans m i ssion bet ween t he hos t
and the FP or command trans m i ssion to
the FP. This is a st raight Dsub9 pin
female cabl e.
Analog RGB i nt erface cable when image
signal is output to the FP from the host.
VGA specific ations (Ds ub15 pin m ale)
FP -CV00 (2.5 m ), FP-CV01 (5m)
USB int erface cable (5m) used for touc h
panel data t rans m i ssion bet ween t he hos t
and the FP or command trans m i ssion to
the FP.
A-B t ype cable.
Replacem ent rubber gasket, us ed when
installing the FP. Same as the FP's
original gas ket.
Provides di s posable screen protect ion from
dust and ot her elem ent s. The touc h panel
can be us ed with the Cover Sheet at t ached
(5 sheets / set)
* Operation environment is Windows®95, WindowsNT®4.0, Windows®98, Windows®2000.
When you use PL-TD000, hardware settings can not be automatically detected.
As a result, select the FP unit's currently connected COM Port, and enter the
settings given in the FP manual for the Allocated I/O address and Interrupt.
1-2FP2600-T41 User Manual
Chapter 2
Specifications
1. General Specifications4. Cable Diagrams
2. Functional Specifications5. Names and Functions of FP Parts
Rated VoltageDC24V
Rat e d Volt a ge R angeDC 19. 2V to DC 28.8V
Powe r Consumption50W or les s
In-Rus h C ur r ent30A or les s
Volt a ge E ndur a nc eA C 1000V 20mA f or 1minute
Insulation Resistance10MΩ or higher a t DC 500V
(bet ween charging and FG terminals)
(bet ween charging and FG terminals)
2-1-2 Environment Specifications
DCV24V (FP2600-T41)
Operating Temperature0 oC to 50 oC
o
Storage Temperature-10
Humidity30 to 85% RH (no n-condensing)
Vibration E nduranc e19.8m/s
Noise Imm unityNoise v oltage : 1200 Vp-p
Pollution LevelNot immune to corrosive gas
GroundingLess than 100Ω, or y our country ' s applicable standard
Protection*1Equivalent to IP65f (JEM1030)
*1 (See the next page's note)
2
- 10 to 25 H z (X, Y, Z directions - 30 minut es each)
Rise time (rise/fall): 1 ns
C to 60 oC
Pulse length: 1 µs
FP2600-T41 User Manual
2-1
Specifications
*1 (Continued from previous page)
The front face of the FP unit, installed in a solid panel, has been tested using
conditions equivalent to the standard shown in the specification . Even though
the FP unit’s level of resistance is equivalent to the standard, oils that should
have no effect on the FP can possibly harm the unit. This can occur in areas
where either vaporized oils are present, or where low viscosity cutting oils are
allowed to adhere to the unit for long periods of time. If the FP’s front face
protection sheet becomes peeled off, these conditions can lead to the ingress of
oil into the FP and separate protection measures are suggested. Also, if nonapproved oils are present, it may cause deformation or corrosion of the front
panel’s plastic cover. Therefore, prior to installing the FP be sure to confirm the
type of conditions that will be present in the FP’s operating environment.
If the installation gasket is used for a long period of time, or if the unit and its
gasket are removed from the panel, the original level of the protection cannot be
guaranteed. To maintain the original protection level, you need to replace the
installation gasket regularly.
2-1-3 Structural Specifications
DC24V (FP2600-T41)
External Dimensions 317W x 243H x 58D mm
We ight3.5 k g or les s
Cooling Sys t emNatur al air circulation
2-2
FP2600-T41 User Manual
Specifications
2-2Functional Specifications (For DC24 V )
Display MediaTFT A ctiv e matrix color LCD
Display S i ze31cm (type 12 .1) Opposite angle
Display Area (mm)246.0W × 1 84.5H
Resolution 800(H)×600(V)pixels(1pixel=R+G+B pixel)
Display C olor s262,14 4 colors ( R/G/B Six bits each)
Brightness
200cd/m
Dot P it ch (mm)0. 33H× 0.33W
Touch Panel
Resolution: 1024× 1 024
Method: Resistive Film (Analog)
SVGA gr aphi c & Tex t mode
800×600,640×480,640×400,640×350,720×400,720
×350 mode display availab le.
Display Mode
However, with 350 pixe ls , 400 pix els , including 50
pixels a t t he top and bott om will be enlar ged a nd
displayed a s 680 p ix els ( 1.5 t imes).
2
(typ)*1
Analog RGB Int er face
Interfaces
SIO Interface(touch Interface)
USB Interface(touch Interface)
Backlight can be changed.
*
Backlight
Life time : 50, 00 0 hour s when conti nuous ly lit (
o
25
C.
2) at
*1 The brightness at central part of the screen when displaying all white.
*2 2.5 times decreased brightness may be the life span, but this value is only for
reference and not a guaranteed value.
FP2600-T41 User Manual
2-3
2-3Interface Specifications (For DC24V)
2-3-1 Analog RGB Interface
Input signal typeAnalog RGB
Input sig nal c haracteri sticImage s ignal : analo g RGB
Sy nchro nous si gnal : TTL le ve l, neg ativ e true or
positive true
Sc anning ty pe : no n-inte rlace
Specifications
Setting by OSD (On Screen
Display)
SizeH Sync.V Sync.Dot Clock Range
800 X 60035.156±1 KHz56±1 Hz36.000MHz±1%
800 X 60037.879±1 KHz60±1 Hz40.000MHz±1%
640 X 48031.469±1 KHz60±1 Hz25.175MHz±1%
640 X 48035.000±1 KHz66±1 Hz30.240MHz±1%
640 X 48037.861±1 KHz72±1 Hz31.500MHz±1%
640 X 40024.827±1 KHz56±1 Hz21.053MHz±1%
640 X 40031.469±1 KHz70±1 Hz25.175MHz±1%
640 X 35031.469±1 KHz70±1 Hz25.175MHz±1%
720 X 40031.469±1 KHz70±1 Hz28.322MHz±1%
720 X 35031.469±1 KHz70±1 Hz28.322MHz±1%
Co ntrast A d jus tme nt
Sub Contrast Adjustment
Brightness Ad justment
Horizontal Display Position Adjustment
Vertical Display Position Adjustment
Horiz ontal A dj ustme nt
Phase Adjustment
Dimmer Adj ustment
Default Se tting (All Cle ar Functio n)
2-4
• W ith vertical 350 pixels, 400 pixels, including 50 pixels at the top and
at the bottom of the screen will be enlarged and displayed at 600
pixels (1.5 times).
FP2600-T41 User Manual
Specifications
Pin Assignments and Signal Names for Analog RGB
Pin
No.
1Analog RR s ig nal inp ut
2Anal og GG si g nal inp ut
3Anal og BB s ignal inp ut
4ReservedNC (spare for input)
5Digital groundingDigital signal GND
6Re turn RR si g nal GND
7Re turn GG si g nal GND
8Re turn BB si g nal GND
9ReservedNC (spare for input)
10Digi tal g ro und ingDi g ital s ig nal GND
11Re se rv e dNC (sp are fo r inp u t)
12Res e rv edNC (s p are fo r inp ut)
13H. SY NCHoriz o ntal sy nc hrono us
14V. SYNCVertical synchronous
15Res e rv edNC (s p are fo r inp ut)
Sig nal NameCo nditi onPin Lo cati on
sig nal inp ut
sig nal inp ut
15
11
5
1
Connector: Mini Dsub 15 pin type
Connector set screw: Inch type (4-40)
FP2600-T41 User Manual
2-5
Loading...
+ 39 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.