Pro-face AGP-3500T, AGP-3510T, AGP-3560T, AGP-3550T, AGP-3500L Installation Manual

...
1
GP-3500/3600/3700 Series
Installation Guide
Package Contents
(1) GP Unit (1) (2) English and Japanese installation
Guides (1 of each) <This Guide> (3) Warning/Caution Information (1) (4) Installation Gasket (1, attached to the
GP unit) (5) Installation Fasteners (Set of 4)
(2 sets of 4 for AGP-3750T only)
(6) RCA-BNC Convertor (1)
(Only for AGP-3550T, AGP-3560T,
AGP-3650T/U, AGP-3750T)
(7) AUX Connector
(1, Attached to the GP unit)
(8) Power Connector (1)
(Attached to the G P unit for DC type)
(9) USB Cable Clamp (2 port) (1 set)
(Holder: 1, Cover: 2)
This unit has been carefully packed, with special attention to qualit y. However, should you find anything damaged or missing, please contact your local GP distributor immediately.
About the Manual
For the detailed information on GP3000 series, refer to the following manuals.
• GP3000 Series Hardware Manual
• Maintenance/Troubleshooting
The manuals can be selected from the help menu of GP-Pro EX or downloaded from Pro-face Home Page.
URL http://www.pro-face.com/otasuke/
About Revision
The nameplate on the GP has the revision number of the GP. In the example below, the asterisk, which is placed at the “5” position, shows that the revision number is “5”.
Caution
Be sure to read the “Warning/Caution Information” on the attached sheet before using the product.
2
Part Names and Functions
Name Description
AStatus LED
B Ex p ans i o n U n i t I n t erf a c e ( E X T ) Used to connect an expan sion unit tha t can tran smit dat a.
C Ethernet Interface (LAN)
10BASE-T/100BASE-TX This interface uses an RJ-45 type modular jack connector (8 pins).
D USB Host Interface (USB)
2 ports Complies with USB 1.1. Uses a “TYPE-A” connector. Power supply voltage:5 VDC
±5%,
Output current:500mA(max.) The maximum communication distance: 5m
E Expansion Unit Interface
*1
Used to connect an expansion unit that can transmit data.
Front Left Side Rear
Bottom
(With CF Card Cover open)
AGP-3650T
AGP-3650T AGP-3650T
AGP-35*0T
A
B C
F
G
H
E
D
I
JK
M
N
O
L
P
Color Indicator
Operation Mode
(Drawing)
Logic execution mode
(when logic is enabled)
Green
ON
OFFLINE
-
In operation RUN
Flashing
In operation STOP
Red
ON When power is turned on.
Flashing
In operation Major Error
Orange
ON Backlight burnout or GP malfuction
*1
*1 Please see GP3000 Series H ardware Manual "Replacing
the Backlight" for the details.
Flashing
During software startup
3
F VM Unit Interface
*1
The interface which connects the VM unit manufactured by Digital Electronics Corporation. (This interface is available only in units with embedded color LCD TFT display.)
G
Auxiliary input/output / Voice Output Interface (AUX)
This interface is External Reset, Alarm Output, Buzzer Output, and sound output.
H
Expansion Memory Interface Cover
Remove the cover to add more memory.
I CF Card Access LED
Lit in green when the CF Card is inserted and the cover is closed, or when the CF Card is being accessed.
• Do not remove or insert the CF Card when the LED lamp is on. Doing so may damage data on the CF Card.
J Power Connector
DC model: Power Socket Connector AC model: Power Input Terminal Block
KCF Card Cover
-
L
AUDIO Input Interface (L-IN/MIC)
It’s an interface to whic h a microphone is connected. A mini jack connector (3.5 mm) is used. (Supported by AGP-3550T, AGP-3560T, AGP-3650T/U, AGP-3750T only)
M
VIDEO Input Interface (V-IN)
It’s an interface to which a video camera is connected. NTSC (59.9 Hz) and PAL (50 Hz) are supported. A RCA connector (75) is used. (Supported by AGP­3550T, AGP-3560T, AGP-3650T/U, AGP-3750T only)
N Serial Interface (COM1)
D-Sub 9-pin plug type. RS232C, RS422, and RS485 are switched by software.
O Serial Interface (COM2)
D-Sub 9-pin socket type. RS422 and RS485 are supported.
P Dip Switches Located inside the CF Card Cover.
*1 The Expansion Unit Interface 1 and VM Unit Interface cannot be used simultaneously with AGP-
3500T/3550T/3560T.
4
General Specifications
Electrical Specifications
DC Model AC Model
Power Supply
Input Voltage DC 24V AC 100 to 240 V Rated Voltage DC 19.2 to 28.8 V AC 85 to 265 V Allowable V oltage
Drop
10 ms (max.)
1 cycle or less (Voltage drop interval must be 1s or more.)
Power Consumption
AGP-3500L AGP-3500S
DC 24 V 2.08 A or less (TYP 1.08 A)
AC 100 V 0.90 A or less (TYP 0.45 A) AC 240 V 0.45 A or less (TYP 0.26 A)
AGP-3500T AGP-3510T AGP-3550T AGP-3560T
DC 24 V 2.08 A or less (TYP 1.22 A)
AC 100 V 0.90 A or less (TYP 0.58 A) AC 240 V 0.45 A or less (TYP 0.29 A)
AGP-3600T AGP-3650T
• When GP Rev.5 is NOT marked
*1
DC 24 V 2.08 A or less (TYP 1.30 A)
• When GP Rev .5 is ma rked
*1
DC 24 V 2.08 A or less
(TYP 1.0 A)
*1 For details on how to check the revision, See "About Revision" (page 1)
• When GP Rev.5 is NOT marked
*1
AC 100 V 0.90 A or less (TYP 0.55 A) AC240 V 0.45A or less (TYP 0.30A)
• When GP Rev.5 is marked
*1
AC 100 V 0.90 A or less (TYP 0.40 A) AC240 V 0.45A or less (TYP 0.23A)
AGP-3600U AGP-3650U
DC 24 V 2.08 A or less (TYP 1.50 A)
AC 100 V 0.90 A or less (TYP 0.55 A) AC240 V 0.45A or less (TYP 0.30A)
GP-3700 Series
50 W or less
AC 100 V 1.1 A or less (TYP0.75 A) AC 240 V 0.7 A or less (TYP0.44 A)
In-Rush Current 30 A (max.) 60 A (max.)
Voltage Endurance
AC 1000 V 2 0 mA for 1 minute (between charging and FG terminals)
AC 1500 V 20 mA for 1 minute (bet we en ch argin g an d FG terminals)
Insulation Resistance DC 500 V 10 M (min.) (between charging and FG terminals)
5
Environmental Specifications
Structural Specifications
Physical
Surrounding Air Temperature
0 to 50 °C
*1
*1 When using STN Colo r L CD m odel i n a n en viro nment w her e the tem peratu re b ecome s or e xceeds
40 °C for an extended period of time, the screen contrast level may decrease from its original level of brightness .
Storage Temperature -20 to +60 °C Ambient Humidity
10 to 90 % RH (Wet bulb temperature: 39 °C max. - no condensation.)
Storage Humidity
10 to 90 % RH (Wet bulb temperature: 39 °C max. - no condensation.)
Dust 0.1 mg/m
3
and below (non-conductive levels)
Pollution Degree For use in Pollution Degree 2 environment.
GP-35/36/3700 Series
except AGP-36*0U
AGP-36*0U
Installation
Grounding
Grounding resistance of 100Ω, 2mm
2
or thicker wire, or your
country’s applicable st andard.(Same for FG and SG terminals)
Structure
*1
*1 The front face of the GP unit, installed in a solid panel, has been tested using conditions equivalent to
the standards shown in the specification. Even though the GP unit’s level of resistance is equivalent to these standards, oils that should have no effect on the GP can possibly harm the unit. This can occur in areas where either vaporized oils are present, or where low viscosity cutting oils are allowed to adhere to the unit for long periods of time. If the GP’s front face protection sheet becomes peeled off, these conditions can lead to the ingress of oil into the GP and separate protection measures are suggested. Also, if non-approved oils are present, it may cause deformation or corrosion of the front panel’s plastic cover. Therefore, prior to installing the GP be sure to confirm the type of conditions that will be present in the GP’s operating environment. If the installation gasket is used for a long period of time, or if the unit and its gasket are removed from the panel, the original level of the protection cannot be guaranteed. To maintain the original protection level, be sure to replace the installation gasket regularly.
Rating: Equivalent to IP65f NEMA #250 TYPE 4X/13 (Front surface at panel embedding) Feature size: All-in-one Installation configuration: Panel embedding
Rating: IP65f (Front surface at p anel em bedding) Feature size: All-in-one Installation configuration: Panel embedding
Cooling Method Natural air circulation