Please read these instructions carefully before use and retain for future
reference.
This oodlight must be installed by a qualied electrician in accordance with
current Building and IET Wiring Regulations.
•This product must be connected to Earth .
•The front of this oodlight is made of tempered glass, which cannot be replaced.
Please take care while installing. If it gets damaged, the oodlight must be
disposed of and replaced.
•LED lamps are extremely bright. To avoid possible damaged to the eyes, do not
stare into an LED beam.
•In use, avoid touching any external surface of the oodlight due to the possibility of
high temperatures.
•If the mains cord lead of this oodlight is damaged, it must be replaced by the
manufacturer, its service agent or a similarly qualied person in order to avoid a
hazard.
•The oodlight can be mounted on normally ammable surfaces.
•The oodlight is suitable for use in an ambient temperature of between -30°C and
+45°C.
•Terminal block is not included. Installation may require advice from qualied
personnel.
POSITIONING
•This oodlight is suitable for outdoor lighting applications, for domestic use only.
Do not use in areas where an explosive or chemical atmosphere may exist. Do not
use in areas where ventilation is restricted.
•It is suitable for mounting on plasterboard, wood or masonry surfaces. Highly
ammable surfaces, such as polystyrene must not be used. Do not install on
damp or conductive surfaces, such as metal. It should be placed away from any
ammable materials.
•Before drilling any xing holes, check that there are no hidden obstructions behind
the mounting surface, such as pipes or cables.
•The recommended height for installation of the oodlight is between 1.8 and 2.5
metres.
•Ensure that there is space around the oodlight to allow adequate circulation of air.
•Orientation of the oodlight is important as the following images show.
The floodlight has a beam angle of 120°. It can be tilted upwards at an angle
of approximately 60° and downwards at
angle of adjustment will vary slightly between models.
an angle of approximately 90°. The
INSTALLATION
The oodlight is suitable for connection to a 200-240V, 50Hz, earthed supply. It is
designed for permanent connection to xed wiring, which must be a suitable circuit
protected by an RCD and an MCB or fuse of the correct rating.
Ensure that the mains supply is isolated before commencing the installation.
•Check that the oodlight is not damaged. If there is any damage, return it to the
place where you purchased it. Do not attempt to repair it yourself.
•Choose your location to x the oodlight, taking into account the guidance above.
•Use the oodlight bracket to mark the position of the xing holes.
•Drill the xing holes, and x the oodlight into position using the appropriate size
screws and wall plugs (not provided). Check that it is securely xed.
•Connect the mains lead from the oodlight to an IP rated junction box. Ensure that
the correct polarities for Live, Earth and Neutral are observed i.e.
After wiring, check that there are no bare wires, all the wires have been correctly
connected and that the cable restraint has been tightened.
•Before connecting the power, perform the electrical tests specied in the current
Building and IET Wiring Regulations to ensure that the installation is safe and that
the wiring has been performed correctly.
•Switch on the electricity to check that the oodlight illuminates. Adjust the angle of
the oodlight so that it illuminates the required area. Tighten the oodlight using
the bolts on the brackets.
REMOTE CONTROL
•The distance between two luminaires should be more than 50cm, with no large
metal obstructions in front of the luminaires.
Daylight mode (sensor works both in
the day and at night)
Nightlight mode (sensor works only
at night, < 50 lux)
Photocell mode (the oodlight lights
automatically at night, < 50 lux)
Not supported by this model
Manual override mode: keep light on
all of the time
Flash mode
SOS mode
Off mode
CLEANING & MAINTENANCE
• Clean the oodlight only with a soft, dry cloth. Do not use any chemicals, abrasives
or solvents that may damage the oodlight.
• The oodlight has a sealed LED lamp and is maintenance free. The LED lamp
cannot be replaced. When the LED lamp reaches the end of its life, the oodlight
will have to be replaced.
SPECIFICATION
SR09944SR09945SR09946
Input Voltage220-240V
50Hz
220-240V
50Hz
220-240V
50Hz
Lumens680lm1400lm2100lm
Wattage10W20W30W
Beam Angle120°120°120°
DimmableNoNoNo
Nominal lifetime of lamp30,000h30,000h30,000h
No. of switching cycles15,00015,00015,000
Colour temperature6500K6500K6500K
Colour rendering (CRI Ra)≥ 65≥ 65≥ 65
Warm up time (60% full light) Instant full light Instant full light Instant full light
Sensor
Microwave
sensor
Microwave
sensor
Microwave
sensor
Detection angle160°160°160°
Sensitivity1-8m1-8m1-8m
Floodlight on time5s - 24h5s - 24h5s - 24h
Ingress ratingIP65IP65IP65
EarthingClass IClass IClass I
Max. projected area of
oodlight (mm)
130 x 90180 x 126210 x 147
Dimensions (mm)130 x 90 x 34180 x 126 x 36 210 x 147 x 37
Weight0.37kg0.58kg0.77kg
INFORMATION ON WASTE DISPOSAL FOR CONSUMERS OF
ELECTRICAL & ELECTRONIC EQUIPMENT.
When this product has reached the end of its life it must be treated as Waste
Electrical & Electronics Equipment (WEEE). Any WEEE marked products
must not be mixed with general household waste, but kept separate for the
treatment, recovery and recycling of the materials used. Contact your local
authority for details of recycling schemes in your area.
Made in China. PR2 9PP