2
Contents
CAUTION................................................................................................................................................. 3
INTRODUCTION
.................................................................................................................................
4-5
PLACEMENT........................................................................................................................................... 5
CONTROL PANEL.................................................................................................................................. 6
OPERATION
............................................................................................................................................
7
EMPTYING THE COLLECTED WATER..........................................................................................7-8
MAINTENANCE...................................................................................................................................... 9
TROUBLESHOOTING
.........................................................................................................................
10
TECHNICAL DETAILS......................................................................................................................... 11

When using electrical appliances basic safety precautions should always be
followed.
Check that the voltage indicated on the rating plate corresponds with that of the
local network before connecting the appliance to the mains power supply.
This appliance is intended for domestic use only. It should not be used for
commercial purposes.
This appliance is designed for indoor use only
Children shall not play with the appliance.
Cleaning and maintenance shall not be made by children without supervision.
There are no user-serviceable parts in this product. Refer servicing to qualified
personnel.
Do not operate this appliance with a damaged plug or cord, after a malfunction or
after being dropped or damaged in any way.
If the supply cord is damaged, it must be replaced by the manufacturer, its service
agent or similarly qualified persons in order to avoid a hazard.
This appliance can be used by children aged from 8 years and above and persons
with reduced physical, sensory, or mental capabilities or lack of experience and
knowledge if they have been given supervision or instruction concerning use of the
appliance in a safe way and understand the hazards involved.
Do not insert anything through the intake or discharge ducts when the dehumidifier
is connected to the supply.
Make sure the dehumidifier is on a stable surface when operating.
Do not operate the dehumidifier in an enclosed space such as a cupboard or closet
Disconnect from the supply when not in use, or during maintenance or cleaning

This operating manual provides useful information necessary for the proper care and
maintenance of the dehumidifier. Please take a few moments to read the instructions
thoroughly and familiarise yourself with the operation of the dehumidifier. Please retain for
future reference
Features
Lightweight, portable design. The castors on the bottom of the unit make it easy to move
Low temperature operation with automatic defrost. When the unit is running in a room
at a temperature between 5°C and 12°C, it will stop every 30 minutes to defrost. Between
12°C and 20°C it will defrost every 45 minutes
Adjustable humidity. The humidity can be set to a range of levels
Timer On/Off. The unit can be programmed to turn on and off automatically
Drainage pipe (optional)

Place the dehumidifier on a flat, solid surface, ensuring that it is a least 20 cm away from any
other wall or surface. Do not position near a bath, sink or other permanently damp or wet area.

Power: turns green when the unit is plugged in, regardless of whether the unit is
operating or not.
Tank full: turns red when the tank is full. If the light is on, empty the water out of the
drainage tank and make sure that the tank is repositioned properly.
Timer: turns green when the timer to turn the unit on or off automatically is
programmed.
Adjustable humidity setting: turns green when the humidity level is being adjusted.
Humidity level and Timer display: this 2 digit display indicates 5 functions:
1. When the unit is plugged in, it will indicate the room humidity level.
2. When the humidity level is being set, it will indicate the humidity level selected.
3. When the humidity in the room is less than 35%, it will show LO
4. When the humidity in the room is higher than 95%, it will show HI
5. When the timer to turn the unit on or off is being set, it will show the number of
hours selected.
Power: press the button once to start operation, the default humidity level is 60%.
Press it again to stop operation.
Timer: 24 hour timer setting. Press the button to program the number of hours delay
to when the unit turns on and off. It can be set between 1 and 24. To cancel the timer
programming, press the button to adjust the time to 00
Adjustable humidity: press to set the desired humidity level in the room, which can
be set in the order: 60%, 65%, 70%, 75%, 80%, 40%, 50%, 55%, 60%. When the
relative humidity in the room is lower than the selected humidity, the operation of the
unit will stop automatically.
Fan speed: press to set the desired fan speed. There are two settings high or low
speed.

1. Open the air outlet manually
Before starting the unit, please make sure that the louver is open. If the louver is closed, the
unit may overheat and will not work effectively.
2. Turning the unit on
When the unit is plugged in, a buzzer will beep and the humidity indicator shows the default
humidity level at 60% with a low fan speed.
Press the POWER button to start operation.
3. Stop operation
Press the POWER button to stop dehumidification.
Never stop the unit by unplugging the supply cord.
EMPTYING THE COLLECTED WATER
When the drainage tank is full, the tank indicator light will turn on, the operation will stop
automatically and the buzzer will beep 15 times to alert the user that the water needs to be
emptied from the drainage tank.
Emptying the drainage tank
1. Disconnect the unit from the mains before starting to remove the water tank.
2. Lightly press on the sides of the tank with both hands and gently pull the tank out.

8
3. Empty the collected water
Note: Do not remove the float from the water tank The water sensor will no longer be able to
detect the water level correctly without the float and water may leak from the tank.
4. If the drainage tank is dirty, wash it with cold or lukewarm water. Do not use detergent,
scouring pads or any other solvent which could lead to damage of the tank and cause water
leakage
5. When replacing the drainage tank, press the tank firmly into place with both hands. If the
tank is not positioned correctly, the TANK FULL sensor will be activated, and the
dehumidifier will not operate.
Continuous water drainage
The unit features a continuous drainage port. By connecting a plastic pipe (with an inner
diameter of 9mm) to it, the water from the dehumidifier can be drained continuously.

IMPORTANT: in order to avoid an electric shock, please power-off the dehumidifier and
pull out the mains plug before performing any maintenance or repair activities.
Cleaning
Unplug from the mains supply before cleaning.
Do not splash water into the dehumidifier.
Clean the outside of the dehumidifier with a damp, not wet, cloth and dry thoroughly before
using. DO NOT use any abrasive or chemical cleaners, which may damage the surface of
the dehumidifier.
Filter
Run a vacuum cleaner lightly over the surface of the filter to remove dust. If the air filter is
exceptionally dirty wash it with warm water and a mild detergent and dry thoroughly.

Note: Do not run the dehumidifier without the air filter.
Storing the dehumidifier
If the dehumidifier is not going to be used for a long time, please follow the steps below:
1. Unplug the dehumidifier from the mains.
2. Empty any water left in the drainage tank and dry thoroughly
3. Fold up the power supply cord and put it in the drainage tank
If one of the conditions listed below occurs, please check the following:
Has the power cord been
disconnected?
Plug the power cord into the
outlet.
Is the tank full indication
lamp blinking? (The tank is
full or in the wrong position.)
Empty the water in the
drainage tank and then
reposition the tank
correctly.
Is the temperature of the
room above 35℃ or below
5℃?
The protection device is
activated and the unit
cannot be started.
The dehumidifying
function doesn't work
Is the air filter clogged?
Clean the air filter as
instructed under
"Maintenance".
Is the air intake or
discharge duct obstructed?
Remove the obstruction
from the air intake or
discharge duct.
Is the air filter clogged?
Clean the air filter as
instructed under
"Maintenance".
Is the unit tilted or
unsteady?
Move the unit on to a stable,
level location.
Is the air filter clogged?
Clean the air filter as
instructed under
"Maintenance".
If a problem persists, turn the dehumidifier off and unplug from the mains. Consult either your
retailer or a qualified person for additional assistance.

11
There are no user serviceable parts inside the dehumidifier. Refer servicing to qualified
personnel
Dehumidify capacity (30°C 80%):
INFORMATION ON WASTE DISPOSAL FOR CONSUMERS OF ELECTRICAL &
ELECTRONIC EQUIPMENT.
When this product has reached the end of its life it must be treated as Waste
Electrical & Electronics Equipment (WEEE). Any WEEE marked products must not
be mixed with general household waste, but kept separate for the treatment,
recovery and recycling of the materials used. Contact your local authority for details
of recycling schemes in your area.
For any enquiries regarding the product, please call 08447 88 00 88