Prodigit 2055B Operation Manual

Model 2055B Energy Monitor with Standby Killer Operation Manual
Thank you for purchasing the 2055B Energy Monitor with Standby Killer. This operating manual will provide an overview of the product, safety instructions, a quick guide to operation, and complete instructions for correct usage. Take the time to completely review these instructions as well as safety warnings to ensure your best use of the product.
Now you can use thi s Energy Monitor with Standby Killer unit to check your ap pliance spend you how munch money, CO a standby killer to shunt down your appliances when they are not used, they are on standby condition. The unit combines human motion by PIR (Pyroelectric Passive Infrared) sensor detection, and appliance’s standby power level, to control AC power on or off automatically. AC power by demand, people come, AC power on; people absent, AC pow er of f, sav e energy, save CO
Advanced features also included:
Monitoring Voltage, Amperage, Watt, KWH, Elapsed Time, Costs and CO Displaying SAVE Amperage, W att, KWH, Elapsed Time, Costs and CO Over current, safe power to your expensive equipments. Zero power crossing switches provide a spike free ON/OFF relay control to prolong your appliances usage life.
Now you’ll know how much power your entire appliances are using, and saving power by Energy Monitor with Standby Killer. With the innovative Energy Monitor with Standby Killer you’ll have peace of mind in more ways than one.
emissions.
2
emissions.
2
emissions to protect ou r on ly on e eart h.
2
Safety Instructions:
The operating voltage is limited to +/- 10% of Line voltage 230Vac. Do not use it in other voltage rating. The maximum output current is 13A. To reduce the risk of electric shock, do not remove cover. No user-serviceable parts inside. Refer servicing to qualified service
personnel.
There shall be a statement in the instructions that, if the equipment is used in a manner not specified by the manufacturer, the
protection provided by the equipment may be impaired.
Measurement category II is for measurements performed on circuits directly connected to the low voltage installation.
2
To reduce the risk of fire or electric shock, do not expose this appliance to rain or m oisture. To reduce the risk of electric shock, do not remove cover. No user-serviceable parts inside. Refer servicing to qualified service
personnel.
Feature Locations:
Feature Locations:
ON / OFF Key
PIR Sensor
PIR and Display Unit
5-foot tethered Cord
Socket
Outlet Unit
Front View
Rear View
Display Panel:
Installation:
1. Turn off the appliance before connection to the unit and remove the power co rd fr om the outlet.
2. Plug the appliance’s power cord into the Energy Monitor with Standby Killer unit socket, and then connect the Energy Monitor with Standby Killer into the outlet.
3. If there are many appliances, please use power strip, plug all appliances power cord into power strip’s sockets and plug power strip into Energy Monitor with Standby Killer socket, then connect the Energy Monitor with Standby Killer into the outlet.
4. Turning the appliance into its Standby mode within 10 seconds. If it is TV, please don’t turn on it, it is Sta ndby mode now; if this appliance with 2 step switch, off→Standby→on, please turn it on Standby mode.
5. Now the Energy Monitor with Standby Killer will measure appliance standby power, the key on the top of the Energy Monitor with Standby Killer shall be flash in green light per second, which indica te standby power is measuri ng. After 30 to 40 seconds , standby power measuring is finished; key’s light shall be in green. Now, it is working and in PIR detect human motion mode.
ON, OFF and PIR detect function:
1. Pressing the key will turn off power to outlet at once. The key will illuminate in red. The unit will continue to measure powe r (e.g. Voltage, Time) an d the function keys and LCD display will continue to operate.
2. Pressing the key will turn power on to outlet at once. The key will illuminate in green. The unit features a spike-free switch function which activates at zero-cross ing and will present clean power to your connected appliance. The unit wi ll measure power and the function keys and LCD display will operate. Now it also activate PIR detect human motion function.
3. If nobody in the PIR effective area, and appliance is on standby condition, the unit will turn off power according to off power delayed time setting, for example, it is 30 minutes, after 30 minutes, the unit shall shunt down power, LED flash in green light every 3 second, and the unit also activate P IR detect huma n motion function . When somebod y moves into the e ffective PIR area, the uni t will turn power on to outlet at once . LED will illuminate in green.
3.1 So there must meet 3 conditions to off power: A, No body in the PIR effective area, B, Appliance is on standby condition, and the unit standby off power level is larger than appliance instant standby power, C, After the unit off power de layed time setting value.
3.2 Please refer to Standby power, Off power delayed time and PIR sensor detecting distances setting for detailed information.
4. Shorter off pow e r de layed time, save more energy, but AC power on/off will be m ore fre qu e nt ly. Appropriate setting off power delayed time will be balance to use appliances and save energy, 1 hour for office, 30 minutes for home, is our suggestion.
5. Summary:
5.1 green light = power on, and PIR detect function on.
5.2 red light = power off, and PIR detect function off.
5.3 green light every 3 second = power off, and PIR detect function on.
5.4 green light every second = standby power is measuring, don’t tough.
Remark:
Editing display flashes indicate this item can be re-set.
Cost mode: pressing central key.
It includes $, Total, Day, Month, Year and SAVE. LCD display default will show Total cost ($) and W.
CO2 mode: pressing left key.
It includes CO2, Total, Day, Month, Year, SAVE, and Lb/Kg.
Key
2
CO
$
 Change Screen
Press
2 Meter
CO
$
 Change Screen
Press
Meter
-
-
2 Meter
CO
$
-
 Change Screen
Press
-
2 Meter
CO
 Change Screen
$
Press
2 Meter
CO
$
 Change Screen
2 Meter
CO
$
 Change Screen
Press
Press
-
2 Meter
CO
$
-
 Change Screen
Press
-
2 Meter
CO
$
-
 Change Screen
Press
Meter mode: pressing right key.
It includes W, V, A, Kwh, Elapsed Time and SAVE.
Key
2
CO
$
 Change Screen
Press
2
CO
$
 Change Screen
Press
-
Meter
-
Meter
2
CO
$
 Change Screen
Press
2
CO
$
 Change Screen
Press
-
Meter
-
Meter
2
CO
$
 Change Screen
Press
-
Meter
-
2
CO
$
Meter
 Change Screen
Press
-
2
CO
$
 Change Screen
Meter
Press
2
CO
$
 Change Screen
Press
2
CO
$
 Change Screen
Press
-
Meter
-
Meter
$ Rate setting:
Press and Hold
3 Second
CO
2
$
 Flash Screen
CO
2
$
 Change Screen
Press
-
Meter
-
Meter
Press
Press
Cost Rate
+0.001
Cost Rate
-0.001
CO2 Rate and Lb/Kg setting:
Press and Hold
3 Second
Press
Press
2
CO
Flash Screen
2
CO
Flash Screen
-
2
$
Meter
CO
$
-
Meter
Flash Screen
Press
Press
Kg-CO
2
Rate
+0.001
Press
-
$
Meter
Press
Kg-CO2Rate
-0.001
2
CO
$
 Change Screen
-
Meter
Reset (Clear):
Press and Hold
3 Second
Press NO
Press YES
-
-
CO
2
 Flash Screen
CO
2
$
Meter
CO
2
$
Meter
Flash Screen
Press
-
$
Meter
CO
2
 Change Screen Change Screen
Press
-
$
Meter
Human motion controlled PIR sensor detect function:
The key flash in green light every 3 second, the unit turn off power to outlet now, and the unit also activate PIR detect human motion
function. When somebody moves into the effective PIR area, t he unit will turn power on to outlet at onc e. The key will illumina te in green.
PIR:
Distances: 15 feet (max.), horizontal angle: 40 degree (max.), vertical angle: 70 degree (max.).
PIR Function Enable
Standby Function Enable
(Green LED Flash every 3 second)
-
CO
2
$
Meter
 Change Screen
Detecting Somebody Motion
Power ON
-
CO
2
$
 Change Screen
Meter
(PIR icon Flash)
Standby power, Delay off time and PIR sensor detecting distances setting:
Standby power: Off, 0.1W to 3289W. Off power delayed time: 10 seconds to 2 hours. PIR sensor detecting distances: Off (shunt down PIR function), 1 foot to 15 feet.
Rate
SAVE
Total Day
$
2
CO
SAVE
Elap Time
+
2
CO
Flash Scre en
Rate
SAVE
Total Day
$
2
CO
SAVE
Elap
Time
+
2
CO
Flash Screen
Hold Meter
Key 3 sec
Year
Month
W
Lb Kg
Meter
Kwh
m
W
V A
Hr
-
h ms
EnterYES NO
$
Press Enter
Year
Month
W
Lb Kg
Meter
Kwh
m
W
V
Hr
A
-
h ms
EnterYES NO
$
Press
Enter
Press Key
+
+0.1 W
Range
OFF, 0.1 ~ 3289 Watt
-0.1 W
hour
-
+
;
Back time
Next time
-
Press Key
Press Key
Select Range
10,20,30,40,50sec;
01 ~ 59 min
01, 02
Press Key
item
item
1, Upper LCD display 12.5W is t he unit standby o ff power level, is automatically measured the standby power of appliance and up a certain percentage when first time install the unit, normally it shall be larger than the instant standby power of appliance. 2, it is adjustable, if user feel 12.5W standby off power level is bigger or smaller. If user adjust this standby off powe r lev el do wn to lower than appliance’s instant standby power (< 10.6W), the unit always on, LED always green of on/off key. 3, Off = shunt down standby power comparative function, the unit always on, LED always green of on/off key.
Lower LCD display 10.6W is appliance’s ins tant standby power now.
1, Default is 30 minutes. 2, Shorter off power delayed time, save more ene rgy, but AC power on/off will be more frequently. Appropria te setting off power delayed time will be balance to use appliances and save energy, 1 hour or 2 hours for office, 30 minutes for home, is our suggestion.
SAVE
CO
SAVE
Elap Time
SAVE
CO
SAVE
Elap Time
Rate
$
2
+
CO
Rate
$
2
+
CO
Year
Total Day
2
Month
h ms
EnterYES NO
$
Flash Scre en
Press
Enter
Year
Total Day
2
Month
h ms
EnterYES NO
$
Change Screen
Meter
Meter
W Lb Kg
Kwh
m
W Hr
-
V A
Press Key
Select Range
Sensitivity
OFF, 1-15 Ft
+
Press Key
Default is 15 feet.
OF F = shunt down PIR functi on, the unit will off power according to Standby off power level and off power delayed time conditions only. After off power delayed time setting value, the unit will be off power when appliance on standby condition, LE D
W
flash in green light every 3 second,
Lb
and the unit will not activate PIR
Kg
detect human motion function and
Kwh
will not turn on power again even
m
W
V
somebody move into PIR effective
A
Hr
area. Do not recommend to off PIR
-
function.
-
Back time
item
Next time
item
Rate
SAVE
Total Day
$
2
CO
SAVE
Elap Time
+
2
CO
Flash Screen
Rate
SAVE
Total Day
$
2
CO
SAVE
Elap
Time
+
2
CO
Change Screen
Year
Month
W Lb Kg
Meter
Kwh
m
W
V
Hr
A
-
h
ms
EnterYES NO
$
Press
Enter
Year
Month
W Lb Kg
Meter
Kwh
m
W
V A
Hr
-
h ms
EnterYES NO
$
Retained measurements:
1. When power to the unit is interrupted, cumulative power consumption KWH, Elapsed Time, Cost, and CO2 will be retained automatically into EEPROM. All user setting, Rate, Standby power, Off power delay time, PIR distances are already retained in EEPROM on every time user setting, it is great advantage for user to set one time only and don’t worry about AC line power is interrupted.
2. When the AC power line back or the unit pl ug into another outlet agai n, cumulative po wer consumpti on KWH, Elapsed Time, Cost, CO2, Rate, Standby power, Off power delay time, and PIR distances will be retrieved au toma tic ally.
Specification:
Item
Voltage 207 ~ 253 Volt 0.1V 0.5% 1% 1sec Current 0.00~13.00 Amp 0.01A 0.5% 1% ± 0.1A 1sec
Active power
KWH
Elapsed Time
Cost ($)
Total/Day/Month/Year
Saved ($)
Total/Day/Month/Year
Cost Rate 0.000~9.999 0.001 --- --- ---
Kg-CO2 or Lb-CO2
Total/Day/Month/Year
Kg-CO2 Rate 0.000~9.999 0.001 --- --- ---
Kg  Lb
Outlet 1 --- --- --- ---
Output status LED
Level Set
Standby Off Power
Delay T ime Set
Spike free switch Spike free switch --- --- --- ---
Specification Accuracy Response Time
Range Res. Typ Max Action Recovery
0.0~99.9 Watt 0.1W
100~3289 Watt 1W 2% ± 5W
0.00~99.99 KWH 0.01KWH 100~9999 KWH 1KWH
00:00~59:59 1sec
100~9999 1hour
0.00~99.99 0.01 100~9999 1
0.00~99.99 0.01 100~9999 1
0.000~9.999 0.01 100~9999 1
1 Kg = 2.2046 Lbs 1 Lb = 0.45359 Kg
Output ON:Green
Output OFF:Red
OFF, 0.1~99.9 Watt 0.1W
100~3289 Watt 1W 10,20,30,40,50 sec
1 ~ 59, min
1, 2 hour
--- --- --- ---
--- --- --- ---
2% ± 5W
1%
1% 2% ± 5W 1sec
30 ppm 1 sec 00:00~99:59 1min
1% 2% ± 5W 1sec
1% 2% ± 5W 1sec
1% 2% ± 5W 1sec
--- --- ---
1sec
ENVIRONMENT CONDITIONS GENERAL SPECIFICATION
IN DOOR USE ONLY Power Rating 230 Vrms ± 10%,50/60Hz
ALTITUDE : UP TO 2000M
OPERATION TEMPERATURE : 0 ~ 50, Max. R.H. 90%
NON OPERATION TEMPERATURE : -10 ~ 60 Max.R.H. 95%℃℃ Ratings 13Amp3289Watts〉,Resistive and Inductive
OPERATION VOLTAGE IS LIMITED TO ±10% OF LINE VOLTAGE
POLLUTION DEGREE : 2
CAT II Weight Around 258g
Maintenance
Protect the meter from adverse weather conditions. The
meter is not waterproof. Do not expose the LCD display to direct sunlight for long periods of time.
CAUTION: To avoid damage to the meter, do not expose it to
sprays, liquids, or solvents.
Clean the exterior of the meter by removing dust with a
lint-free cloth.
Use care to avoid scratching the clear plastic display filter. For further cleaning, use a soft cloth or paper towel
dampened with water. You can use a 75% isopropyl alcohol solution for more efficient cleaning.
Power Consumption
L/W/H
Max. 0.8Watt; Standby: 0.4W
L135mm x W63mm x H68mm
Display/PIR unit)
(Outlet Unit +
CAUTION: To avoid damage to the surface of the meter, do
not use abrasive or chemical cleaning agents.
PRODIGIT ELECTRONICS CO.LTD.
8F, NO 88, Baojhong Rd., Sindian Dist., New Taipei City 23144, T ai wan, R.O.C TEL : 886-2-2918-2620 FAX : 886-2-2912-9870 E-MAIL : sales@prodigit.com.tw http://www.prodigit.com.tw
Loading...