Prodif 592SH Installation, Use And Maintenance Manual

Page 1
OILLESS COMPRESSOR / AUTOLUBRICATED:
592SH
SYNOPSIS :
INSTALLATION AND SITE....................P 1
INSTRUCTIONS, USES OPERATING..P 1
FOR YOUR SECURITY.......................P 2
MAINTENANCE..................................P 2
FAULTS / SOLUTIONS..............................P 5
MARKING - TRACKING.............................P 5
PICTOGRAMS LEGEND............................P 6
GUARANTEE ADVICE...............................P 6
GUARANTEE...........................................P 6
STAMP OF THE RET AILER
A-NOTICE 592SH-ce .pmd (2012-06-20)
WARNING:
FIRST USE OF
COMPRESSOR
During the commissioning of your compressor, it is possible that oil mist escapes from the vents of the plastic cover: This is quite normal, a lubricant is deposited on the piston to facilitate the mechanical running, it burns in the first minutes.
WE DECLARE AT OUR RESPONSABILITY THAT THE FOLLOWING PRODUCT :
1) MODEL: Shown on the label.
2) SERIAL NUMBER : Shown on the label.
3) YEAR OF MANUFACTURE : Shown on the label.
”CE” EUROPEAN COMPLIANCE
DECLARATION
MANUAL
INSTALLATION USE MAINTENANCE
COMPLIES WITH EUROPEAN GUIDELINES FOR SECURITY AND ENVIRONMENT ON THE MACHINES:
2006/42/CE - Machinery - Replaces the 98/37/CE 2006/95/CE - LV - Low Voltage 2004/108/CE - EMC - Electromagnetic compatibility 2009/105/CE - Simple pressure vessels - Replaces the 87/404/CEE 97/23/CE - Pressure Equipment. (safety valve)
Procedure: Module C1 - Notified Body 0036 Test Report No : P-PRC-03-10-C001763-01
2000/14/CE - Noise emission in the environment by equipment for use outdoors
According to Appendix VI - Notified body 0071 Sound power level guaranteed : 97 dBA Sound power level measured : 94 dBA
2002/96/CE et 2002/95/CE - WEEE et RoHS.
STANDARDS USED : EN 1012-1, EN ISO 12100-1 , EN ISO 12100-2, EN 13857, EN 286-1, EN953, EN ISO 13732-1, EN50419, EN 55014-1, EN61000-3-2, EN61000-3-3, EN 60204-1, ISO3857-1/-2.
BUC: 20-06-2012 President: F . MURET
Page 2
6
PICTOGRAMS
GUARANTEE
2 - INSTRUCTIONS, OPERATING ADV ICE
To obtain the best efficiency, please respect the following indications:
- PLACE: Use the compressor indoors or under shelter, do not expose it to the rain or near water jets. Do not use the compressor in an explosive atmosphere.
- VENTILATION: The compressor must be in a place which allows ventilation, do not cover the ventilation openings.
- TEMPERATURE: Use the compressor between (+ 5°C and +35°C) (Otherwise, there are risks for
the electrical motor.)
- BLOCK OF COMPRESSION: Keep the compressor at 50 cm at least from any wall to ensure a correct circulation of air.
- TENSION: Check that the sector tension and tension indicated on the label are the same :
(Single phase:230 Volts - 50 Hz)
Connect as near to the electrical meter as
possible (Less than 10 meters in order to avoid a rise in intensity, the engine would not start in cold weather):
- Of 16 Amps under 230V.
- Connected to the ground.
- Connected to a differential protection.
Check that the compressor has not been damaged
during the transport.
The switch must be in position "Off". (Fig. 2) Verify under the tank that the drain valve is closed
(fig. 3).
- USING AN ELECTRIC EXTENSION:
- BEFORE USE:
Please only use an extension if absolutely
necessary. We recommend the following dimensions: 5 meters maximum length with section of wire of 2,5mm ².
Too small diameter wire sections and big lengths
would cause serious damage to the engine.
It is better to extend the air pipe, which also will
give you stock of air.
INSTALLA TION AND SITE
INSTRUCTIONS
You have just bought your air compressor, it will give you appreciable services. Please ensure first that your compressor is powerful enough, you may use it for:
- Inflating Tyres - Balloons - Swimming pools -
Rafts etc......
- Blowing / vacuum-cleaning / painting
- Using pneumatic tools :(ex. gun nailer, stapler, screw driver, impact wrench, sand blasting, etc...)
Before use, it is imperative to read ENTIRELY the present NOTE.
1 - INSTALLA TION AND SITE
1
- ADJUSTMENT OF PRESSURE:
Adjust the pressure of use and the consumption of
air to the characteristics of the tools you wish to use. (See the documentation provided with your tools).
The quantity of air consumed depends on the type
of tool used: do not use a tool consuming more than 60% of the possibilities of your compressor.
The pressure controller is adjusted in factory and
needs no re adjustment.
Pressure gauge A (Fig. 4) indicates the pressure
inside the tank. To adjust the output of air pressure , it is necessary to turn the button ( Fig. 4) In clockwise direction to increase pressure, and opposite to decrease it. The pressure gauge B (Fig. 4) indicates the useful exit air pressure, you must use the tool only when the pressure in the tank is higher than the pressure of use of the tool.
9 - GUARANTEE
The compressor is guaranteed for a period of 12
months starting from the date of purchase. During this period, the manufacturer undertakes to
repair or to replace free of charge any defective part, after an inspection has been completed at the factory, in accordance solely with the judgement of
our technicians
.
The guarantee is restricted to manufacturing
defects and applies to equipment used under normal conditions. The guarantee will not apply if the machine has been dismantled or modified or if there are missing parts. It excludes any responsibility for direct or indirect damage to persons, animals or objects: if there are missing parts, if the material or subset were dismounted or modified.
Parts which are subject to normal wear, e.g
pressure switches, piston rings, belts, air filters, gaskets and valves, etc., do not fall within the scope of the guarantee. No return is accepted without prior authorization.
The carriage costs incurred in returning all part of a machine, even under guarantee, will always be charged to the user.
The respect of the advice of use will preserve
the performances, the life expectancy as well as the legal guarantee applicable to your compressor.
A compressor not maintained can be damaged
quickly.
If you do not use the compressor in accordance
with the contents of these instructions, we will refuse any responsibility towards persons animals or objects damaged.
The compressor presented in this note was
designed in the respect of the safety requirements in agreement with the directives and texts in force within the European Community. (See EC Declaration).
This note was written in respect with Machine
Directive 2006/42/CE.
All uses advice necessary are indicated there.
Please keep this manual with the machine. Please read entirely the safety requirements and
8 - GUARANTEE ADVICE
7 - PICTOGRAMS LEGEND
5: Risk of electric discharge.
3: Do not touch apparent hot surfaces (Cylinder
head, pipe between tank and cylinder head, non­return valve).
To undertake the maintenance of this machine
before air pressure has completely fallen and electricity has been disconnected.
Do not open the air valve before you have
connected the air pipe and the tool to the compressor.
Do not breathe or project the compressed air of
the compressor towards a person .
Use a sound protection in the event of
prolonged use.
This equipment cannot be thrown as waste and
is subject to a selective collection for its valorization or recycling.
4: Automatic restart of the compressor without
warning.
01: Read entirely the note before the startup or any operation of maintenance on the compressor. 02: To use a sound protection in the event of prolonged use.
WARNING SIGNALS:
OBLIGATION SIGNALS:
Acoustic power level guaranteed.
- USING A PNEUMATIC EXTENSION:
For pressures higher than 7 bar, use pipes
reinforced with steel braid.
the instructions before using the compressor. To obtain the best results, respect all warnings and instructions.
SOME ADVICE:
1 - Producer 2 - Tank capacity 3 - Power 4 - Tension- Phase Qty and frequency. 5 - Maximum pressure 6 - Compressor weight 7 - Air delivery at 7 bar
8 - Revolutions per minute 9 - Measured noise level 10 - Serial number 11 - Code model 12 - Reference 13 - Year of manufacture
1 3 2 4 5
ATAD-NOITCETORPCIRTCELE
REWOP Wk
5,12,2345,5 elgniS esahP
ESUFWOLBWOLS
A 0161
zH05-V032
NOITCESELBAC
muminiM
²mm 5,25,2
Page 3
5
2
4 - MAINTENANCE
Before any intervention on the compressor:
- Disconnect electrical cable.
- Empty the tank.
- Let cool the compressor. A regular maintenance ensures working
without problem and increases the longevity of the compressor.
FOR HANDLING: do not carry the compressor,
use the wheels (not the handles).
See table of the programmed maintenance(page 3)
Purge condensates: Advised after each use:
Purge to avoid the corrosion of the tank, .see (fig. 3). These condensates contain oil , so you must recover the condensates in a suitable container not to reject into the sewers.
Clean or change the air filter: To guarantee the flow
of the compressor.( Fig. 7)
controls checking: By the tank pressure gauge,
check maximum value of the compressor.
Electric connector blocks checking: Tighten
correctly electric wires to have a good engine power.
3 - FOR YOUR SECURITY
The air delivered by your compressor allows you
to use many tools, follow conditions, advice and in certain cases RESTRICTIONS OF USE for air tools using compressed air.
Avoid any degradation of the electric cable and
move away from heat sources higher than 70°C.
At the end of work, unplug the cable and roll up it
around the handle of the compressor.
Do not use the compressor with bare or wet feet.
Do not to touch the compressor with wet hands. Do not pull the cord to move the compressor or
to remove the plug.
Do not allow children to use the compressor.
Do not leave the compressor without monitoring
when it is connected; it can become source of dangers.
Never introduce objects into the protection of the
transmission system.
- AFTER USING:
Never stop by disconnecting the electrical cable.Never leave the compressor power connected
under pressure.
Switch the interruptor in "Off" position . (Fig. 2)Empty the tankDrain the tank (Fig.3)Disconnect the electrical cable.
Ordinary maintenance does not require
specialized personnel.
The servicing of the group of compression as
well as other more complex bodies, must be carried out by specialized personnel: Call for your retailer.
The compressor does not start:
No electrical supply. The compressor is already in pressure, empty
the tank.
The pressure switch is defective.
The compressor starts with difficulty, and thermal protection sometimes operates:
The electric tension is insufficient. (210V
Minimum).
Electrical supply cord is too long, or wire section
too small. (electric cable coil)
Engine overload by cold weather. Electrical supply cord is cut or disconnected. You stopped your compressor by disconnecting
the cable and decompression did not take place.
Decompression defect, the tank is full, the
decompression did not take place. (Check: Correct restarting with empty tank).
High resistance of the group: after removing air
filter, pour 4 to 5 drops of engine lubricating oil at the air entry of the compressor and make the compressor working during one minute, in order to deposit an oil film in the mechanism.
Thermal protection is out of order, needs to be
regulated or changed according to the type.
Abnormal noises, vibrations:
Loosened or worned parts. Worn group (mechanical noises). Bad chocking of the compressor. Tension of the belt to be checked. Air leakage in the pneumatic circuit.
Opening of the safety valve:
Bad adjustment of the pressure controller, you
need to check that pressure gauge A ( Fig. 4) does not exceed the pressure indicated on the identifica­tion plate, this must be regulated by a specialist.
The safety valve is badly regulated or is
defective, to be replaced by an approved equivalent model.
5 - FAULTS / SOLUTIONS
Air leaking from the valve of air pressure switch :
- defective valve of the pressure switch, change it. No return valve blocked by an impurity or worn,
clean or change the no return valve or the internal rubber valve with its spring. ( Fig. 9)
Low flow rate, pressure does not increase:
air filter is dirty, you must clean it.(Fig. 7) air pressured is leaking by the connections, check
the connections.
Cylinder valves are broken or valve seat gasket
torn, you must check the pump.
Excessive consumption by the segmentation,
gasket leakages, you must check the pump.
Impossible adjustment of the output air pressure:
The internal diaphragm of the pressure reducer is
torn (fig.4) replace it.
Please follow the advice below for the mainte­nance of your compressor:
FAUL TS / SOLUTIONS
COMMUNICATION- TRACKING PRODUCT
SECURITY
MAINTENANCE
To use your compressor correctly, only use it
intermittently, i.e. 60% of use for 40% of downtime. Beyond this limit, the engine risks overheating problems.
- PRECAUTIONS TO PAINT:
If the electric motor and the interior of the pump are dirty, your compressor life expectancy will be reduced:
In order to avoid this problem, only move away
the compressor by lengthening the tube of your tool.
The electric safety of this machine is assured only
when it is correctly connected with an efficient grounding connection , as recommended in the rules of electric safety requirements.
The responsibility for the manufacturer will not be
committed if grounding connection of the installation is incorrect.
To avoid burns, during the work and a few minutes
after working, never touch the pipes of connection of the cylinder head, the non-return valve nor the parts of the compressor subjected to heating.
- OPERATING TIME:
For any communication with the distributor, please indicate the identification sticker data of the product [fig.1] The sticker is applied on the side of
the compressor.
IDENTIFICATION STICKER OF THE PRODUCT
[fig.1]
6 - COMMUNICATION- TRACKING PRODUCT
1 2 3 4 5 6
7
8
9
1
12
10
11 13
Page 4
TABLES / ILLUSTRA TIONS
3
4
Fig. 2
Fig. 4
Fig. 3
Fig.7
Fig.9
INTERNAL VAL VE
.PEREDOCNOITPIRCSED
940D030338revoccitsalP 2018102409leehW 3017418309toofnoitcuS 5012482149"4/1evlaV.teRnoN 6014022149gnilpuockciuQ 70136
03509"4/1evlaVniarD 8016111509recudeRerusserP 901185414905ØeguaG 901910250904ØeguaG 0110104149evlavytefaS 1111824149s
exaleehW 2116330509epip/epipwoblE 2119642149epip/haehwoblE 5114218309pilC 6111008309eldnahrebbuR 1310903609hctiwseru
sserP 2312325609elbaclacirtcelE 4312035609rotom-elbaclacirtcelE 5419162149evlavnruteron-ebuT 5416642149rednilyc-e
buT
SPARE P ART LIST
ecnanetniamehtfoyticidoireP
"emmargorpecnanetniam"snoitarepo
hcaE

keewhtnomh005h0001
ehtgnigruP
setasnednoc
riaehtgninaelC
retlif
lriaehtgnignahC
retlif
gninaelclareneG
gnikcehC
stnemtsujda
gninethgitgnikcehC
snoitcennocfo
cirtcelegnikcehC skcolbrotcennoc
Loading...