Procom SN280TYA, SL280TYA Owner's Operation And Installation Manual

Page 1
1
SN280TYA
SL280TYA
WARNING: If the information in this
manual is not followed exactly, a fire or explosion may result in causing property damage, personal injury, or loss of life.
WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual for correct installation and opera­tional procedures. For assistance or addi­tional information consult a qualified installer, service agency, or gas supplier.
This appliance may be installed in an aftermar­ket* permanently located, manufactured (mobile) home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.
*Aftermarket: Completion for sale, not for purpose of resale, from the manufacturer.
Table of Contents
Safety Information W arnings.....................................2
Air For Combustion & V entilation............................4
Installation....................................................................6
Installing Logs.............................................................9
Operation Heater........................................................11
Specifications.............................................................13
Troubleshooting........................................................14
Parts Breakdown & Parts List..................................17
Log Placing Instructions..........................................21
OWNER’S OPERATION AND INSTALLATION MANUAL
FREE STANDING LP.& NATURAL
GAS VENT-FREE STOVE
Do not store, or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.Do not touch any electrical switch; do not
use any phone in your building. Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. If you cannot reach your gas supplier, call the fire department. Installation and service must be performed by a qualified installer, service agency or gas supplier.
Installer : please leave these instructions with the consumer
WA TER V APOR: A BY -PRODUCT OF UNVENTED ROOM HEA TERS
Water vapor is a by-product of gas combustion.An unvented room heater produces approximately one (1)ounce (30 ml) of water for every 1,000BTU’s (.3KW’s) of gas input per hour, refer to page 6.
Consumer : please retain these instructions for future use
CINTINENT AL APPLIANCE INC
5 Musick 4600 Highlands Parkway S.E. Irvine Suite # D/E CA 92618 Smyrna, GA 30080
TOLL-FREE NUMBER: 1-877-886-5989
Page 2
2
IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, operate, or service this heater. Improper use of this heater can cause serious injury or death from burns, fire, explosion, electrical shock, and carbon monoxide poisoning.
SAFETY INFORMATION WARNINGS
DANGER: Carbon monoxide
poisoning may lead to death!
Carbon Monoxide Poisoning:
Early signs of carbon monoxide poisoning resemble the flu with headaches, dizziness, or nausea. If you have these signs, the heater may not be working properly. Get fresh air at once! Have heater serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes. Propane/LP Gas: Propane/LP gas is odorless. An odor-making agent is added to Propane/LP gas. The odor helps you detect a Propane/LP gas leak. However, the odor added to Propane/LP gas can fade. Pro­pane/LP gas may be present even though no odor exists. Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this heater.
WARNING: Any change to
this fireplace or its controls can be dangerous.
WARNING: Do not allow fans to
blow directly into the heater. Avoid any drafts that alter burner flame patterns. Ceiling fans can create drafts that alter burner flame patterns. Altered burner patterns can cause sooting.
Do not place clothing or other flammable material on or near the appliance. Never place any objects in the fireplace.
Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.
WARNING: Do not use a blower
insert, heat exchanger insert, or other accessory not approved for use with this heater.
Heater becomes very hot when running fireplace. Keep children and adults away from hot surfaces to avoid burns or clothing ignition. Fireplace will remain hot for a time after shutdown. Allow surfaces to cool before touching.
Carefully supervise young children when they are in the room with fireplace.
You must operate this heater with the heater screen in place. Make sure heater screen is in place before running heater.
Keep the appliance area clear and free from combustible materials, gasoline, and other flammable vapors and liquids.
1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.
2. Do not place propane/LP supply tank(s) inside any structure. Locate propane/LP supply tank(s) outdoors.
3. If you smell gas:
Shut off gas supply.Do not try to light any appliance.Do not touch any electrical switch:
do not use any phone in your building.
Immediately call your gas supplier
from a neighbor’s phone. Follow the gas supplier’s instructions.
If you cannot reach your gas
supplier, call the fire department.
4. This heater shall not be installed in a bedroom or bathroom.
5. Do not use this heater as a wood-
burning heater. Only use the logs provided with the heater.
6. Do not add extra logs or ornaments
such as pine cones, vermiculite, or
rock wool.Using these added items can cause sooting. Do not add lava rock around base. Rock and debris could fall into the control area of heater. After servicing, always replace screen before operating heater.
7. Y ou must operate this heater with
the heater screen in place. Make sure heater screen is in place before running heater.
8. This heater is designed to be
smokeless. If logs ever appear to smoke, turn off heater and call a qualified service person. Note: During initial operation, slight smoking could occur due to log curing and heater burning manufacturing residues.
9. To prevent the creation of soot,
follow the instructions in Cleaning and Maintenance, page 12.
10.Before using furniture polish, wax,
carpet cleaner, or similar products, turn heater off. If heated, the vapors from these products may create a white powder residue within burner box or on adjacent walls or furniture.
11.This heater needs fresh air
ventilation to run properly. This heater has an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS shuts down the heater if not enough fresh air is available. See Air for Combustion and Ventilation, pages 4 through 6. If heater keeps shutting off, see Troubleshooting, pages 14 through 16.
12. Do not run heater:
Where flammable liquids or vapors
are used or stored.
Under dusty conditions.
13.Do not use this heater to cook
food or burn paper or other objects.
14. Do not use heater if any part has
been under water. lmmediately call a qualified service technician to inspect the room heater and to replace any part of the control system, and any gas control, which has been under water.
Page 3
3
SAFETY INFORMATION
Continued
15. Turn off heater and let it cool before servicing. Only a qualified service person should service and repair heater.
16. Operating heater above elevations of 4,500 feet could cause pilot outage.
17. Do not operate heater if any log is broken. Do not operate heater if a log is chipped (dime-sized or larger).
18. To prevent performance problems, do not use propane/LP fuel tank: of less than 100lbs. capacity.
LOCAL CODES
lnstall and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code. ANSZ223.1, also known as NFPA54*. *Available from: American National Standards lnstitute, lnc. 1430 Broadway New York. NY10018 National Fire Protection Association, lnc. Batterymarch Park Quincy. MA 02269 This heater is designed for vent-free operation. State and local codes in some areas prohibit the use of vent-free heaters.
UNPACKING
1. Remove top inner pack.
2. Tilt carton so that stove is upright.
3. Remove protective side packaging.
4. Slide stove out of carton.
5. Remove protective plastic wrap.
6. Remove screen by lifting and then pulling forward.
7. Remove log set by cutting plastic ties.
8. Carefully unwrap log.
9. Check for any shipping damage. If stove or log is damaged, promptly inform dealer where you bought stove.
PRODUCT FEATURES SAFETY PILOT
This heater has a pilot with an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS/pilot is a required feature for vent-free room heaters. The ODS/pilot shuts off the heater if there is not enough fresh air.
PIEZO IGNITION SYSTEM
This heater has a piezo ignitor. This system requires no matches, batteries, or other sources to light heater.
PRODUCT IDENTIFICATION
Figure1-Vent-Free Propane/LP Gas Freestanding Pedestal Stove
Page 4
4
AIR FOR COMBUSTION AND VENTILATION
WARNING: This heater shall not
be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air. Read the following instructions to insure proper fresh air for this and other fuel-burning appliances in your home.
PROVIDING ADEQUATE VENTILATION
The following are excerpts from National Fuel Gas Code, NFPA54/ ANSZ223.1.Section 5.3, Air for Combustion and Ventilation. All spaces in homes fall into one of the three following ventilation classifications:
1. Unusually Tight Construction
2. Unconfined Space
3. Confined Space The information on pages 4 through 6 will help you classify your space and provide adequate ventilation.
Confined and Unconfined Space
The National Fuel Gas Code, ANS Z223.1 defines a confined space as a
space whose volume is less than 50 cubic feet per 1,000 Btu per hour (4.8 m
3
per kw) of the aggregate input rating of all appliances installed in that space and an unconfining space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8 m
3
per kw) of the aggregate input rating of all appliances installed in that space. Rooms communicating directly with the space, in which the appliances are installed*, and through openings not furnished with doors, are considered a part of the uncon­fined space.
This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air. * Adjoining rooms are communicating only if there are doorless passage­ways or ventilation grills between them.
Unusually Tight Construction
DETERMINING FRESH-AIR FLOW FOR HEATER LOCA TION
Determining if You Have a Confined or Unconfined Space
Use this worksheet to determine if you have a confined or unconfined space. Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms.
1. Determine the volume of the space (length
×
width×height).
Length
×
Width×Height= cu.ft. (volume of space)
Example: Space size 20ft. (length)
×
16ft( width)×8ft. (ceiling height)=2560cu. ft. (volume of space) If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these rooms to the total volume of the space.
2. Divide the space volume by 50 cubic feet to determine the maximum Btu/Hr the space can support.
(volume of space)÷50 cu. ft.=(Maximum Btu/Hr the space can support)
Example: 2560 cu. ft. (volume of space)
÷50 cu.ft.=51.2 or 51,200(maximum Btu/Hr the space can support)
AIR FOR COMBUSTION AND VENTILATION
Continued
The air that leaks around doors and windows may provide enough fresh air for combustion and ventilation. However, in buildings of unusually tight construction you must provide additional fresh air. Unusually tight construction is defined as construction where: a) walls and ceilings exposed to the
outside atmosphere have a continuous water vapor retarder with a rating of one perm ( 6
×10
-11
kg per pa-sec-m2) or less with openings gasketed or sealed
and b) weather stripping has been added on openable windows and doors
and c) caulking or sealants are applied to areas such as joints around win­ dow and door frames, between
sole plates and floors, between wall-ceiling joints, between wall panels, at penetrations for plumbing, electrical, and gas lines,
and at other openings. If your home meets all of the three criteria above, you must provide additional fresh air. See Ventilation Air From Outdoors, page 5. If your home does not meet all of the three criteria above, proceed to
Determining Fresh-Air Flow For Heater Location, below.
Page 5
5
WARNING: Rework worksheet, adding the space of the adjoining unconfined space. The combined spaces must have enough fresh air to supply all appliances in both spaces.
If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support, the space is an unconfined space. You will need no additional fresh air ventilation.
3. Add the Btu/Hr of all fuel burning appliances in the space. Vent-free heater
Btu/Hr
Gas water heater*
Btu/Hr
Gas furnace
Btu/Hr
Vented gas heater
Btu/Hr
Gas heater logs
Btu/Hr
Other gas appliances* +
Btu/Hr
Total =
Btu/Hr *Do not include direct-vent gas appliances. Direct-vent draws combustion air from the outdoors and vents to the outdoors.
4. Compare the maximum Btu/Hr the space can support with the actual amount of Btu/Hr used.
Btu/Hr (maximum the space can support) Btu/Hr (actual amount of Btu/Hr used)
Example : 51,200 Btu/Hr(maximum the space can support)
56,000 Btu/Hr(actual amount of Btu/Hr used) The space in the above example is a confined space because the actual Btu/Hr used is more than the maximum Btu/Hr the space can support. You must provide additional fresh air. Your options are as follows: A. Rework worksheet, adding the space of an adjoining room. If the extra space provides an unconfined space, remove door to adjoining room or add ventilation grills between rooms. See Ventilation Air From Inside Building, below. B. Vent room directly to the outdoors. See Ventilation Air From Outdoors, below . C. Install a lower Btu/Hr heater, if lower Btu/Hr size makes room unconfined.
Figure 2 -Ventilation Air from Inside Building
Example: Gas water heater 30,000 Btu/Hr Vent-free heater
+ 26,000 Btu/Hr
Total = 56,000 Btu/Hr
WARNING: If the area in which the heater may be operated is smaller than that defined as an unconfined space or if the building is of unusually tight construction, provide adequate combustion and ventilation air by one
of the methods described in the National Fuel Gas Code, ANS Z223.1, Section 5.3 or applicable local codes.
This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must provide two permanent openings: one within 12
" of the ceiling and one within 12" of the floor
on the wall connecting the two spaces (see options 1 and 2, Figure 2). You can also remove door into adjoining room (see option 3, Figure 2). Follow the National Fuel Gas Code. NFPA 54/ANS Z223.1. Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.
Ventilation Air From lnside Building
Ventilation Air From Outdoors
Provide extra fresh air by using ventilation grills or ducts. You must provide two permanent openings: one within 12
" of the ceiling and one within 12" of the floor. Connect
these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces. Follow the National Fuel Gas Code, NFPA 54/ANS Z223.1, Section 5.3. Air for Combustion and Ventilation for required size of ventilation grills or ducts. IMPORTANT: Do not provide openings for inlet or outlet air into attic if attic has a thermostat-controlled power vent. Heated air entering the attic will activate the power vent.
Figure 3 -Ventilation Air from Outdoors
Page 6
6
NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your primary heating system. Do not install this heater as your primary heat source. If you have a central heating system, you may run the system's circulating blower while using heater. This will help circulate the heat throughout the house . In the event of a power outage, you can use this heater as your primary heat source.
INSTALLATION
WARNING: A qualified service person must install heater. Follow all local codes.
WARNING: Never install the heater
in a bedroom or bathroomin a recreational vehicle
where curtains, furniture, clothing,
or other flammable objects are less than 42 inches from the front, top, or sides of the heater.
WARNING: Maintain the minimum clearances. If you can, provide greater clearances from floor, ceiling, and adjoining side and back walls.
CAUTION: This heater creates warm air currents. These currents move heat to wall surfaces next to heater. Installing heater next to vinyl or cloth wall coverings or operating heater where impurities (such as tobacco smoke, aromatic candles, cleaning fluids, oil or kerosene lamps, etc.) in the air exist may discolor walls.
IMPORTANT: Vent-free heaters add moisture to the air. Although this is beneficial, installing heater in rooms without enough ventilation air may cause mildew to form from too much moisture. See Air for Combustion and Ventilation, pages 4 through 5.
CHECK GAS TYPE FOR SL280TY A use propane/LP gas FOR SN280TY A use Natural gas.
Call dealer where you bought heater for proper type heater.
Figure 4 -Minimum Clearance to Wall
WATER VAPOR:A BY-PRODUCT OF UNVENTED ROOM HEATERS
Water vapor: a by-product of gas combustion.An unvented room heater productes approximately one(1) ounce (30ml) of water for every 1,000BTU’s (.3KW’s) of gas input per hour. Unvented room heaters are recommended as supplemental heat (a room) rather than a primary heat source (an entire house),in most supplemental heat appllcation, the water vapor does not create a problem, in most applications, the water vapor enhances the low humidity atmosphere experience during cold weather.
The following steps will help insure that water vapor does not become a problem,
1.Be sure the heater is sized properly for the application,including ample combusion air and circulation air.
2.If high humidity is experienced, a dehumldifier may be used to help lower the water vapor content of the air.
3.Do not use an unvented room,heater as the primary heat source.
Ceiling
Page 7
7
CLEARANCES TO COMBUSTIBLES (Vent-Free Operation Only)
Carefully follow the instructions below. This stove is a freestanding unit designed to set directly on the floor.
IMPORTANT: You must maintain minimum wall and ceiling clearances during installation. The minimum clearances are shown in Figure 4. Measure from outermost point of stove top.
Minimum Wall and Ceiling Clearances
(see Figure 4) A. Clearances from outermost point
of stove top to any combustible side wall should not be less than 12 inches.
B. Clearances from outermost point of
stove top to any combustible back wall should not be less than 6 inches (lncludes corner installations).
C. Clearances from the stove top to
the ceiling should not be less than 48 inches.
CONNECTING TO GAS SUPPLY
WARNING: A qualified service person must connect heater to gas supply. Follow all local codes.
CAUTION: Never connect heater directly to the propane/LP supply. This heater requires an external regulator (not supplied). lnstall the external regulator between the heater and propane/LP supply.
INSTALLATION ITEMS NEEDED
Before installing heater, make sure you have the items listed below.
piping (check local codes) sealant (resistant to propane/LP gas) equipment shutoff valve* test gauge connection* sediment trap see joint pipe wrench flexible gas hose.(check local codes)
A CSA design-certified equipment shutoff valve with 1/8
" NPT tap is
an acceptable alternative to test gauge connection. Purchase the optional CSA design-certified equipment shutoff valve from your dealer. See Accessories.
Figure 5 -Gas Regulator Location and Gas Line Access Into Stove Cabinet
Figure 6 -External Regulator With Vent Pointing Down
Figure 7 -Gas Connection
FOR LP models
The installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 1 1 to 14
" inches of water .
If you do not reduce incoming gas pressure, heater regulator damage could occur. lnstall external regulator with the vent pointing down as shown in Figure 6. Pointing the vent down protects it from freezing rain or sleet.
* Purchase the optional CSA design-certified equipment shutoff valve from your dealer. See Accessories, page 13. * Minimum inlet pressure for purpose of input adjustment.
Propane/LP Supply T ank
FOR NG models: (4” W.C.-10.5”W.C.) No External Regulator Needed
purchase
NG MODELS: 5” to 10.5” W.C. Gas supplier provides external regulator for natural gas.
Page 8
8
WARNING: Never connect heater to private (non-utility) gas wells. This gas is commonly known as wellhead gas.
CAUTION: Use only new, black iron or steel pipe. Internally-tinned copper tubing may be used in certain areas. Check your local
codes. Use pipe of 1/2
" diameter or
greater to allow proper gas volume to heater. If pipe is too small, loss of pressure will occur.
Installation must include an equip­ment shutoff valve, union, and plugged 1/8
" NPT tap. Locate NPT tap within
reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 7).
IMPORTANT: Install equipment shutoff valve in an accessible location. The equipment shutoff valve is for turning on or shutting off the gas to the appliance. Apply pipe joint sealant lightly to male threads.This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves.
CAUTION: Use pipe joint seal­ant that is resistant to liquid petroleum(LP) gas.
We recommend that you install a sediment trap in supply line as shown in Figure 7. Locate sediment trap where it is within reach for cleaning. Install in piping system between fuel supply and heater. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into heater controls. If sediment trap is not installed or is installed wrong, heater may not run properly.
CAUTION: To avoid damage to regulator, hold gas regulator with a wrench when connecting into gas piping and/or fittings.
WARNING: Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once.
CAUTION: Make sure external regulator has been installed between propane/LP supply and heater. See guidelines under Connecting to Gas Supply, page 7.
Figure 8 -Equipment Shutoff Valve
Pressure Testing Gas Supply Piping System Test Pressures In Excess Of 1/2 PSIG(3.5kPa)
1. Disconnect heater with its appliance main gas valve (control valve) and equipment shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig will damage heater regulator.
2. Cap off open end of gas pipe where equipment shutoff valve was connected.
3. Pressurize supply piping system by either using compressed air or opening propane/LP supply valve.
4. Check all joints of gas supply piping system. Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak.
5. Correct all leaks at once.
6. Reconnect heater and equipment shutoff valve to gas supply. Check reconnected fittings for leaks.
Pressure Testing Heater Gas Connections
1. Open equipment shutoff valve (see Figure 8).
Figure 9.1 -Checking Gas Joints
Page 9
9
2. Open natural supply tank valve.
3. Make sure control knob of heater is in the OFF position.
4. Check all joints from equipment shutoff valve to control valve (SL280TYA see Figure 9.1 SN280TYA see Figure 9.2). Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak.
5. Correct all leaks at once.
6. Light heater (see Operating Heater).Check all other internal joints for leaks.
7. Turn off heater (see To Turn Off
Gas to Appliance).
WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury.
CAUTION: After installation and periodically thereafter, check to ensure that no flame comes in contact with any log. With the heater set to HIGH, check to see if flames contact any log. If so, reposition logs according to the log installation instructions in this manual. Flames contacting logs will create soot.
INSTALLING LOGS
It is very important to install the logs exactly as instructed. Do not modify logs. Only use logs supplied with heater.
Place log set on grate to fit as illus­trated in Figure 10. Make sure log sits flat on firebox floor (see Figure 10).
IMPORTANT: Make sure log does not cover any burner ports (see Figure11).
Also see placing instruction pgs.
21.
Figure 10 -Installing Log Set
Figure 11 -Installing Log Set (Top View)
Figure 9.2 -Checking Gas Joints
Natural Gas Meter
Log set
Firebox Floor
Page 10
10
ACCESSORY PF06-YJLF-F Tools required: Phillips screwdriver
1. From back of heater remove the Knock-out center panel with two brackets at the four sides with a phillips head screwdriver (see Figure12).
2. Disconnect power cord wires from blower motor (if connected) (see Figure 13).
3. Disconnect green ground wire from blower housing (if connected)by removing screw holding wire terminal (see Fig­ure 13).
4. Install one rubber bushing provided in blower kit into the
1.5
" hole in the left rear of firebox
floor. Access hole through the rectangular opening in the rear panel (see Figure 14).
5. Attach the two brackets to blower housing using four white screws provided in blower kit ( 2 for each bracket) (see Figure 15). Tighten screws securely. Place blower assembly temporarily on top panel.
6. Working from the rear of the stove place entire power cord, including operation control housing, in lower control
Figure 12 -Removing Stove Knock-out Panel
compartment.
7. Route ends of 4-wire power cord and thermostat switch up from the lower control compartment through the rubber bushing, then up to the upper cavity of stove (see Figure 16).
8. Using one big black screw provided in blower kit, mount
bracket with thermostat switch to the left of firebox on back of heater (see figure 16).
9. Attach the terminal ends of the white and black power cord wires to the terminals on the blower motor (see Figure 13). Push firmly.
10. Attach the terminal end of the green power cord wire to the front tab of the blower housing using black screw provided (see Figure 13).
11. Place blower assembly temporarily on top panel.
12. Install control knob onto output shaft of operation control housing (see figure 16). Place operation control housing just inside control compartment door in front of stove (see Figure 17).
13. Using two black screws pro­vided in blower kit, mount blower operation control housing to mounting tab in left side of lower control compartment (see Figure
17).
14. Check to make sure that the power cord is completely clear
of blower wheel and there are no foreign objects in blower wheel.
15. Using the screws removed previously, mount blower assem­bly to stove by reattaching the Knock-out center panel to rear panel (see Figure 15). Tighten screws securely.
16 Use screws provided in blower kit
to assemble the plate which as­sembled with strain relief bush­ing and power cord on the knock­out center panel.
17. Peel off the backing paper and stick the supplied wiring diagram decal on the stove floor as shown in Figure 16.
18. Plug power cord into a convenient 3-prong grounded wall receptacle near the stove.
19. Using Auto/O/Man switch, turn blower on and check for operation. Turn on Auto/O/Man switch to the desired position. Man position will remain con­stantly on. Auto position will be controlled by the thermostat on fan blower unit. To stop the operation turn unit switch to the O position.
20. All remaining parts from blower kit may be discarded.
WARNING: ELECTRICAL GROUNDINGINSTRUCTIONS This appliance is equipped with a three­prong (grounding) plug for your pro­tection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle.
NOTICE: Shut off gas heater during the following blower installation.
Figure 13 -Removing Wires From Blower
Figure 15 -Attaching brackets to blower and mounting blower
Figure 14 -Installing Bushing
Figure 17-Installing Blower Control Housing
Figure 16 -Routing Power Cord
Page 11
11
OPERATING HEA TER
FOR YOUR SAFETY
READ BEFORE LIGHTING
WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
A. This appliance has a pilot which
must be lighted by hand. When lighting the pilot, follow these instructions exactly.
B. BEFORE LIGHTING smell all
around the appliance area for gas. Be sure to smell next to the floor because some gases are heavier than air and will settle on the floor.
WHA T TO DO IF YOU SMELL GAS
Do not try to light any appliance.Do not touch any electrical
switch; do not use any phone in your building. Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. If you cannot reach your gas
supplier, call the fire department.
C. Use only your hand to push in or
turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don't try to repair it. Call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion.
D. Do not use this appliance if any
part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system, and any gas control, which has been under water.
1. STOP! Read the safety information.
2. Make sure equipment shutoff valve is fully open.
3. Turn control knob clockwise to the OFF position.
4. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow "B" in the safety information. If you don't smell gas, go to the next step.
5. Turn control knob counterclock-
wise
to the PILOT position. Press in control knob for five (5) seconds (see Figure 18). Note: You may be running this
heater for the first time after hooking up to gas supply. If so, the control knob may need to be pressed in for 30 seconds or less. This will allow air to bleed from the gas system.
6. With control knob pressed in,
press and release ignitor button. This will light pilot. The pilot is attached to the front burner. If needed, keep pressing ignitor button until pilot lights. Note: If pilot does not stay lit, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure (page 13).
7. Keep control knob pressed in for
LIGHTING
INSTRUCTION
NOTICE: During initial operation of
new heater, burning logs will give off a paper-burning smell. Orange flame will also be present. Open a window to vent smell. This will only last a few hours.
30 seconds after lighting pilot. After 30 seconds. release control knob.
If control knob does not pop
out when released, contact a qualified service person or gas supplier for repairs. Note: If pilot goes out, repeat steps 3 through 7. This heater has a safety interlock system. Wait one (1) minute for system to reset before lighting pilot again.
8. Turn control knob counter­clockwise
to desired heating level. The burners should light. Set control knob to any heat level between HI and LO.
TO TURN OFF GAS
TO APPLIANCE
Shutting Off Heater
Turn control knob clockwise
to
the OFF position.
Shutting Off Burners Only (Pilot stays lit)
Turn control knob clockwise
to
the PILOT position.
Figure 18 -Control Knob and Ignitor Button Location
Figure 19 -Pilot
CAUTION: Do not try to adjust heating levels by using the equipment shutoff valve.
Page 12
12
THERMOSTAT CONTROL OPERA TION SN280TYA/SL280TY A The
thermostat control knob can be set to any comfort level between HI and LO. The thermostat will gradually modu­late the heat output and flame height from higher to lower settings, or pilot in order to maintain the comfort level you select. The ideal comfort setting will vary by household depending upon the amount of space to be heated, the output of the central heating system, etc. Note: Selecting the Hi setting with the control knob will cause the burners to remain fully on, without modulating down in most cases.
MANUAL LIGHTING PROCEDURE
1. Follow steps 1 through 5 under Lighting Instructions.
2. Depress control knob and light pilot with match.
3. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow step 8 in column 2.
INSPECTING BURNERS
Check pilot flame pattern and burner flame patterns often.
PILOT FLAME PATTERN
Figure 20 shows a correct pilot flame pattern. Figure 21 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple.This will cause the thermocouple to cool. When the thermocouple cools, the heater will shut down. If pilot flame pattern is incorrect, as shown in Figure 21: turn heater off (see To Turn Off Gas to Appliance, page 11) see Troubleshooting, pages 14 through 16
Figure 20 -Correct Pilot Flame Pattern
Figure 22 shows a correct burner flame pattern. Figure 23 shows an incorrect burner flame pattern. If burner flame pattern is incorrect: turn heater off (see To Turn
Off Gas to Appliance, page 11)
see Troubleshooting, pages 14
through 16
CLEANING AND MAINTENANCE
Figure 21 -Incorrect Pilot Flame Pattern
BURNER FLAME PATTERN
Figure 22 -Correct Flame Pattern with Control Knob Set to High Flame
Figure 23 -Incorrect Flame Pattern with Control Knob Set to High Flame
WARNING: Turn off heater and
let cool before cleaning.
CLEANING BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLE
The primary air inlet holes allow the proper amount of air to mix with the gas. This provides a clean burning flame. Keep these holes clear of dust, dirt, lint, and pet hair. Clean these air inlet holes prior to each heating season. Blocked air holes will create soot. We recommend that you clean the unit every three months during operation and have heater inspected yearly by a qualified service person. We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt. To clean these parts we recommend using com­pressed air no greater than 30 PSI. Your local computer store, hardware store, or home center may carry com­pressed air in a can. You can use a vacuum cleaner in the blow position. If using compressed air in a can, please follow the directions on the can. If you don't follow directions on the can, you could damage the pilot assembly.
1. Shut off the unit, including the pilot. Allow the unit to cool for at least thirty minutes.
2. Inspect burner, pilot and primary air inlet holes on injector holder for dust and dirt (see figure 24).
3. Blow air through the ports/slots and holes in the burner.
4. Check the injector holder located at the end of the burner tube again. Remove any large particles of dust, dirt, lint, or pet hair with a soft cloth or vacuum cleaner nozzle.
5. Blow air into the primary air holes on the injector holder.
6. In case any large clumps of dust have now been pushed into the burner repeat steps 3 and 4.
CAUTION: You must keep
control areas, burner, and circulating air passageways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a qualified service person. Heater may need more frequent cleaning due to excessive lint from carpeting, bedding material, pet hair, etc.
Figure 24 -Injector Holder on Outlet Burner Tube
Page 13
13
Clean the pilot assembly also. A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly. There is a small pilot air inlet hole about two inches from where the pilot flame comes out of the pilot assembly (see Figure 25). With the unit off, lightly blow air through the air inlet hole. You may blow through a drinking straw if compressed air is not available.
Air Passageways Use a vacuum cleaner or pressurized air to clean. Exterior Use a soft cloth dampened with a
mild soap and water mixture. Wipe
the cabinet to remove dust. LOGS If you remove logs for cleaning,
refer to Installing Logs, page
9, to properly replace logs. Replace log(s) if broken or chipped
(dime-sized or larger).
MAIN BURNER
Periodically inspect all burner flame holes with the heater running. All slotted burner flame holes should be open with yellow flame present. All round burner flame holes should be open with a small blue flame present. Some burner flame holes may become blocked by debris or rust, with no flame present. If so, turn off heater and let cool. Either remove blockage or replace burner. Blocked burner flame holes will create soot. Review your video included with your heater for additional cleaning instructions.
Figure 25 -Pilot Inlet Air Hole
SPECIFICA TIONS SL280TY A
Btu(Variable) 20000/28000 Gas T ype Propane/LP Ignition Piezo Manifold Pressure 8.0"W.C. Inlet Gas Pressure (In. of water)* Maximum 14" Minimum 11"
SN280TY A
Btu(Variable) 20000/28000 Gas T ype NG Ignition Piezo Manifold Pressure 3.0"W.C. Inlet Gas Pressure (In. of water)* Maximum 10.5" Minimum 5"
SL280TY A SN280TYA
Dimensions, Inches (H
×W×
D)
Stove 27 1/2"
×
28"×17 1/2"
Carton 21 3/4"
×
30 1/4"×31 1/2" Weight, pounds Stove 99lbs. Shipping 1 16lbs. *For purposes of input adjustment
REPLACEMENT P ARTS
Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.
P ARTS UNDER WARRANTY
Contact authorized dealers of this product. If they can't supply original replacement part(s), call the number on the front of this manual. When contacting your dealer or PRO-COM, have ready:
Your nameYour addressModel and serial numbers
of your heater
How heater was malfunctioningType of gas used (Natual Gas or
propane/LP gas)
Purchase dateWarranty card.
Usually, we will ask you to return the defective part to the factory.
P ARTS NOT UNDER WARRANTY
Contact authorized dealers of this product or Parts Central. If they can’t supply original replacement part(s) call PRO-COM’s toll-free number on the front page.
ACCESSORIES
Purchase these heater accessories from your local dealer or Parts Central. This part is not currently available from PRO-COM.
EQUIPMENT SHUTOFF V ALVE -
Equipment shutoff valve with 1/8" NPT tap.
Burner
FLEX IBLE GAS HOSE
Flexible gas hose is used for con­necting the heater to gas supply.
the flex hose must be CSA Approved.
Page 14
14
TROUBLESHOOTING
Note: All troubleshooting items are listed in order of operation.
WARNING: Only a qualified service person should service and repair heater.
CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/pilot unit.
REMEDY
1. Replace ignitor.
2. Replace ignitor.
3. Reconnect ignitor cable.
4. Free ignitor cable if pinched by any metal or tubing. Keep ignitor cable dry.
5. Replace ignitor cable.
6. Replace control valve ( piezo
is part of control valve).
1. Turn on gas supply or open
equipment shutoff valve.
2. Fully press in control knob while
pressing ignitor button.
3. Continue holding down control
knob. Repeat igniting operation until air is removed.
4. Clean ODS/pilot (see Cleaning
and Maintenance) or replace ODS/pilot assembly.
5. Reposition gas regulator turn
control knob to pilot position.
6. Contact local propane/LP gas
company.
1. Press control knob in all the way.
2. After ODS/pilot lights, keep control knob pressed in for 30 seconds.
3. Fully open equipment shutoff valve.
4. Hand tighten until snug, then tighten 1/4 turn more.
5. A) Contact local propane/LP gas company.
B) Clean ODS/pilot (see Cleaning
and Maintenance) or replace ODS/pilot assembly.
6. Replace thermocouple.
7. Replace control valve.
POSSIBLE CAUSE
1. Ignitor electrode positioned wrong.
2. Ignitor electrode broken.
3. Ignitor electrode not connected to ignitor cable.
4. Ignitor cable pinched or wet.
5. Broken ignitor cable.
6. Bad piezo ignitor.
1. Gas supply is turned off or
equipment shutoff valve closed.
2. Control knob not fully pressed in
while pressing ignitor button.
3. Air in gas lines when installed.
4. ODS/pilot is clogged.
5. Gas regulator selling is not correct.
6. Control knob not in pilot position.
7. Depleted gas supply.
1. Control knob not fully pressed in.
2. Control knob not pressed in long
enough.
3. Equipment shutoff valve not fully open.
4. Thermocouple connection loose at control valve.
5. Pilot flame not touching thermocouple, which allows thermocouple to cool causing pilot flame to go out. This problem could be caused by one or both of the following: A) Low gas pressure. B) Dirty or partially clogged ODS/pilot.
6. Thermocouple damaged.
7. Control valve damaged.
OBSERVED PROBLEM
When ignitor button is pressed in, there is no spark at ODS/pilot.
ODS/pilot lights but flame goes out when control knob is released.
When ignitor button is pressed in, there is a spark at ODS/pilot but no ignition.
Page 15
15
TROUBLESHOOTING
Continued
OBSERVED PROBLEM
Burner(s)does not light after ODS/pilot is lit.
Delayed ignition of burner(s).
Burner backfiring during combustion.
Moisture/condensation noticed on windows.
Slight smoke or odor during initial operation.
Heater produces whistling noise when burner is lit.
Dark residue on logs or inside of fireplace.
White powder residue forming within burner box or on adjacent walls or furniture.
POSSIBLE CAUSE
1. Burner orifice is clogged.
2. Inlet gas pressure is too low.
3. Burner orifice diameter is too small.
4. Thermocouple leads disconnected or improperly connected.
5. Burners will not come in remote position.
1. Manifold pressure is too low.
2. Burner orifice is clogged.
1. Burner orifice is clogged or damaged.
2. Burner damaged.
3. Gas regulator defective.
1. Not enough combustion/ventila­ tion air.
1. Residues from manufacturing processes.
2. Not enough air.
3. Gas regulator defective.
1. Turning control knob to Hi position when burner is cold.
2. Air in gas line.
3. Air passageways on heater blocked.
4. Dirty or partially clogged burner orifice.
1. Improper log placement.
2. Rafts or other air currents affecting flame pattern.
3. Air holes at burner inlet blocked.
4. Burner flame holes blocked.
1. When heated, vapors from
furniture polish, wax, carpet cleaners, etc. turn into white powder residue.
REMEDY
1. Clean burner orifice (see Cleaning and Maintenance) or replace burner orifice.
2. Contact local propane/LP gas company.
3. Replace burner orifice.
4. Reconnect leads (see wiring diagram).
5. Replace battery in transmitter and receiver.
1. Contact local propane/LP gas company.
2. Clean burner (see Cleaning and Maintenance) or replace burner orifice.
1. Clean burner orifice (see Cleaning and Maintenance) or replace it.
2. Replace burner.
3. Replace gas regulator.
1. Refer to Air for Combustion and Ventilation Requirements (page 4).
1. Problem will stop after a few hours of operation.
2. Check burner for dirt and debris. If found, clean burner (see Clean­ ing and Maintenance, page 12).
3. Replace gas regulator.
1. Turn control knob to LO position and let warm up for a minute.
2. Operate burner until air is removed from line. Have gas line checked by local propane/LP gas company.
3. Observe minimum installation clearances (see pages 6 through 8).
4. Clean burner (see Cleaning and Maintenance) or replace burner orifice.
1. Properly locate logs (see Installing Logs, page 9).
2. Eliminate source of drafts around heater.
3. Clean out air holes at burner inlet.
Periodically repeat as needed.
4. Remove blockage or replace burner.
1. Turn heater off when using
furniture polish, wax, carpet cleaner or similar products.
Page 16
16
Continued
WARNING: If you smell gas
Shut off gas supply.
Do not try to light any appliance.Do not touch any electrical switch; do not use any phone in your building.Immediately call your gas supplier from a neighbor’s phone. Follow the gas
supplier’s instructions.
If you cannot reach your gas supplier, call the fire department.
IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc, create fumes. These fumes may mix with combustion air and create odors.
REMEDY
1. Ventilate room. Stop using odor causing products while heater is running.
2. Locate and correct all leaks(see Checking Gas Connections, page 8).
1. Open window and/or door for ventilation.
2. Contact local Propane/LP gas company.
3. Clean ODS/pilot (see Cleaning, page 12 ).
1. Locate and correct all leaks (see Checking Gas Connections, page 8).
2. Replace control valve.
1. Take apart gas tubing and
remove foreign matter
2. Locate and correct all leaks
(see Checking Gas Connections, page 8).
1. This is common with most
heaters. If noise is excessive, contact qualified service person.
1. Refer to Air for Combustion and
Ventilation requirements (page
4).
POSSIBLE CAUSE
1. Heater burning vapors from paint, hair spray, glues, etc. (See IMPORTANT statement above).
2. Gas leak. See Warning State­ ment at the top of page.
1. Not enough fresh air is available.
2. Low line pressure.
3. ODS/pilot is partially clogged.
1. Gas leak. See Warning Statement at the top of page.
2. Control valve defective.
1. Foreign matter between control valve and burner.
2. Gas leak. See Warning State­ ment at the top of page.
1. Metal is expanding while heat­ ing or contracting while cooling.
1. Not enough combustion/ventilation air.
OBSERVED PROBLEM
Heater produces unwanted odors.
Heater shuts off in use (ODS operates).
Gas odor even when control knob is in OFF position.
Gas odor during combustion.
Heater produces a clicking/ticking noise just after burner is lit or shut off.
Moisture/condensation noticed on windows.
Page 17
17
ILLUSTRATED PARTS BREAKDOWN
SN280TYA SL280TYA
1
Page 18
18
PARTS LIST
SN280TYA SL280TYA
This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 13 of this manual.
Page 19
19
ILLUSTRATED PARTS BREAKDOWN
SN280TYA SL280TYA
Page 20
20
This list contains replaceable parts used in your heater.When ordering parts ,follow the instructions listed under Replacement Parts on page 13 of this manual.
PARTS LIST
SN280TYA SL280TYA
Page 21
21
LOG PLACING INSTRUCTIONS
Follow the precedures below and the successive drawings to put log sets in place to the gas pedestal stove (indoor vent-free):
NOTICE : THE POSITION OF THE LOGS SHOULD AVOID FLAME.
1.
Take out the paper liner (See
DRAWING 1).
2. Take away the screen from the
appliance, and remove the logs pack­age (See DRAWING 2).
DRAWING 1
DRAWING 2
Page 22
22
INSTALLING THE DECORATING LOGS OF SN280TYA/SL280TYA
1. Fasten log #1.log #2 and log#3 separately on the correspondent angle iron(See Figure 2).
Figure 1
Figure 2
Figure 3
Figure 4 Figure 5
3. Insert the pin on the upper part of log #5 into the pinhole on the left side of log #2. Place the lower part of log #5 on the flat roof at the left side of log #4(See Figure 4).
2. Fasten log #4 separately on the correspondent angle iron(See Figure 3).
4. Insert the pinhole on the upper part of log #6 into the pin on the left side of log #1. Place the lower part of log #6 on the flat roof at the left side of log #4(See Figure 5).
Loading...