Procom QNSD250T Owner's Operation And Installation Manual

VENT-FREE GAS STOVE
OWNER’S OPERATION
AND INSTALLATION
MANUAL
MODEL
QNSD250T
Questions, problems, missing parts? Before returning to your retailer, call
Monday through Friday or email customerservice@usaprocom.com
®
US
WARNING: If the information in this manual is not
followed exactly, a re or explosion may result causing
property damage, personal injury or loss of life. — Do not store or use gasoline or other ammable va-
pors and liquids in the vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the re
department.
Installation and service must be performed by a quali­ed installer, service agency or the gas supplier.
WARNING: This appliance is equipped for Natural and
Propane gas. Field conversion is not permitted other than
between natural or propane gases.
www.usaprocom.com
200198-01A
2
TABLE OF CONTENTS
Safety ........................................................ 3
Specications ............................................ 4
Qualied Installing Agency ........................ 5
Product Features ....................................... 5
Local Codes............................................... 5
Product Identication ................................. 6
Unpacking.................................................. 6
Water Vapor: A By-Product Of
Unvented Room Heaters ..................... 6
Air For Combustion and Ventilation ........... 7
Installation ................................................. 8
Operation ................................................. 17
Inspecting Burners................................... 19
Care And Maintenance ............................ 20
Troubleshooting ....................................... 22
Accessories ............................................. 25
Service Hints ........................................... 25
Technical Service..................................... 25
Parts ........................................................ 26
Replacement Parts .................................. 27
Warranty .................................................. 28
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
This is an unvented gas-red heater. It uses air (oxygen)
from the room in which it is installed. Provisions for ad-
equate combustion and ventilation air must be provided.
Refer to Air For Combustion and Ventilation section on page 7 of this manual.
WARNING: Improper installation, adjustment, al-
teration, service or maintenance can cause injury or property damage. Refer to this manual for correct in­stallation and operational procedures. For assistance
or additional information consult a qualied installer,
service agency or the gas supplier.
This appliance may be installed in an aftermarket,* per­manently located, manufactured (mobile) home, where not prohibited by local codes.
This appliance is only for use with propane or natural
gas. Field conversion by any other means including the use of a kit is not permitted.
* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer.
SAVE THIS BOOK
www.usaprocom.com
3
200198-01A
SAFETY
IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, op­erate, or service this heater. Improper use of this heater can cause serious injury or death
from burns, fire, explosion, electrical shock and carbon
monoxide poisoning. Failure to follow these instructions will void the warranty.
Only a qualied installer, service
agent, or local gas supplier may install and service this product.
WARNING: Keep the appli-
ance area clear and free from
combustible materials, gasoline, and other ammable vapors and
liquids.
WARNING: This appliance
can be used with propane or
natural gas. It is shipped from the factory adjusted for use with propane.
DANGER: Carbon monoxide
poisoning may lead to death!
CARBON MONOXIDE POISONING: Early
signs of carbon monoxide poisoning resemble the u, with headaches, dizziness or nausea. If you have these signs, the heater may not be working properly. Get fresh air at once! Have heater serviced. Some people are more af­fected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the inu­ence of alcohol and those at high altitudes.
NATURAL AND PROPANE/LP GAS: Natural
and Propane/LP gas are odorless. An odor­making agent is added to the gas. The odor helps you detect a gas leak. However, the odor added to the gas can fade. Gas may be present even though no odor exists.
WARNING: Any change to
this heater or its controls can
be dangerous.
WARNING: Do not allow fans
to blow directly into replace. Avoid any drafts that alter burner ame patterns.
WARNING: Do not use a
blower insert, heat exchange
insert or other accessory not approved for use with this heater.
WARNING: Due to high tem-
peratures, the appliance should
be located out of trafc and away
from furniture and draperies.
WARNING: Do not place
clothing or other flammable
material on or near the appli-
ance. Never place any objects
in the heater.
WARNING: The heater be­comes very hot when running. Keep children and adults away
from hot surfaces to avoid burns
or clothing ignition. Heater will remain hot for a time after shut­down. Allow surfaces to cool
before touching.
WARNING: Carefully super­vise young children when they are in the room with the heater.
WARNING: You must operate this heater with screen in place.
1. Do not place Propane/LP supply tank(s) inside any structure. Propane/LP supply tank(s) must be placed outdoors.
2. This heater shall not be installed in a bedroom or bathroom.
www.usaprocom.com
200198-01A
4
3. This heater needs fresh air ventilation to run properly. This heater has an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS shuts down the heater if not enough fresh air is available. See Air for Combustion and Ventilation, pages 7. If heater keeps shutting off, see Trouble- shooting, page 22.
4. Keep all air openings in front and bottom of heater clear and free of debris. This will ensure enough air for proper combustion.
5. If heater shuts off, do not relight until you have provided fresh, outside air. If heater keeps shutting off, have it serviced.
6. Do not run heater:
• Where ammable liquids or vapors are
used or stored.
• Under dusty conditions.
7. Before using furniture polish, wax, carpet cleaner, or similar products, turn heater off. If heated, the vapors from these prod­ucts may create a white powder residue within burner box or on adjacent walls or furniture.
8. Do not use heater if any part has been under water. Immediately call a qualied service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water.
9. Turn off and unplug heater and let cool before servicing. Only a qualied service person should service and repair heater.
SAFETY
10. Operating heater above elevations of 4,500 feet could cause pilot outage.
11. To prevent performance problems, do not use propane/LP fuel tank of less than 100 lbs. capacity.
12. Do not use this heater as a wood-burning heater. Use only the logs provided with the heater.
13. Solid fuels should not be burned in a heater in which a vent-free log set is installed. Do not use this heater to cook food or burn paper or other objects.
14. To prevent sooting, follow the instructions in Care and Maintenance, see page 20.
15. Do not add extra logs or ornaments such as pine cones, vermiculite, or rock wool. Using these added items can cause soot­ing. Do not add lava rock around base. Rock and debris could fall into the control area of heater. After servicing, always replace screen before operating heater.
16. This heater is designed to be smokeless. If logs ever appear to smoke, turn off heater and call a qualied service person.
Note: During initial operation, slight smok-
ing could occur due to log curing and the heater burning manufacturing residues.
17. Do not use this heater if any log is broken. Do not operate heater if a log is chipped (dime-size or larger).
SPECIFICATIONS
Model QNSD250T
Gas Type Natural Gas Propane Gas
Maximum Input Rating 25,000 Btu/Hr 25,000 Btu/Hr
Minimum Input Rating 13,000 Btu/Hr 21,000 Btu/Hr
Ignition Electronic Piezo Electronic Piezo
Regulator Pressure Setting 4" W.C. 9" W.C.
Inlet Gas Pressure* (inches of water)
(*for purposes of input adjustment)
Maximum 9" Maximum 14"
Minimum 5" Minimum 11"
Heater Dimensions (HxWxD) •
25" × 33.5" × 13"
Carton Dimensions (HxWxD) •
24.8" × 34.25" × 13"
Stove Weight • 49.8 lbs
Shipping Weight • 60.4 lbs
www.usaprocom.com
5
200198-01A
QUALIFIED INSTALLING AGENCY
Only a qualied agency should install and replace gas piping, gas utilization equipment or accessories, and repair and equipment ser­vicing. The term “qualied agency” means any individual, rm, corporation, or company that either in person or through a representative is engaged in and is responsible for:
a) Installing, testing, or replacing gas piping
or
b) Connecting, installing, testing, repairing,
or servicing equipment; that is experienced in such work; that is familiar with all precau­tions required; and that has complied with all the requirement of the authority having jurisdiction.
PRODUCT FEATURES
SAFETY PILOT
This heater has a pilot with an Oxygen Deple­tion Sensing (ODS) safety shutoff system. The ODS/pilot shuts off the heater if there is not enough fresh air.
PIEZO IGNITION SYSTEM
This heater is equipped with an electronic piezo control system. This system requires one AAA battery (provided).
THERMOSTATIC CONTROL
The control automatically cycles the burner on and off to maintain a desired room tem-
perature.
2 GAS OPTIONS AVAILABLE
Your heater is equipped to operate on either Propane/LP or Natural gas. The heater is shipped from the factory ready for connect­ing to Propane/LP. The heater can easily be changed to Natural gas by having your quali­ed installer follow the instructions on page 10 and the markings on the heater.
LOCAL CODES
Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code, ANSI Z223.1/NFPA 54*.
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
1 Batterymarch Park
Quincy, MA 02269-9101
This heater is designed for vent-free op­eration. State and local codes in some areas prohibit the use of vent-free heaters.
State of Massachusetts: The installation must be made by a licensed plumber or gas tter in the Commonwealth of Mas­sachusetts.
Sellers of unvented propane or natural gas-red supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit.
In the State of Massachusetts the gas cock must be a T-handle type. The State of Massachusetts requires that a exible appliance connector cannot exceed three feet in length.
PROCOM HEATING, INC. PATENT INFORMATION
This product may be covered by one or more of the following United States patents:
8,915,239 8,851,065 8,764,436 8,757,202 8,757,139 8,752,541 8,568,136 8,545,216 8,517,718 8,516,878 8,506,290 8,465,277 8,317,511 8,297,968 8,281,781 8,241,034 8,235,708 8,152,515 8,011,920 7,967,006 7,967,007
7,654,820 7,730,765 7,677,236 7,607,426 7,434,447
www.usaprocom.com
200198-01A
6
WATER VAPOR: A BY-PRODUCT OF
UNVENTED ROOM HEATERS
Water vapor is a by-product of gas combus­tion. An unvented room heater produces ap­proximately one (1) ounce (30 mL) of water for every 1,000 BTUs (0.3 KWs) of gas input per hour. Unvented room heaters are recom­mended as supplemental heat (a room) rather than a primary heat source (an entire house). In most supplemental heat applications, the water vapor does not create a problem. In most applications, the water vapor enhances the low humidity atmosphere experienced during cold weather.
The following steps will help ensure that water vapor does not become a problem.
1. Be sure the heater is sized properly for the application, including ample combustion air and circulation air.
2. If high humidity is experienced, a dehu­midier may be used to help lower the water vapor content of the air.
3. Do not use an unvented room heater as the primary heat source.
UNPACKING
1. Remove top inner pack.
2. Tilt carton so that heater is upright.
3. Remove protective side packaging.
4. Slide heater out of carton.
5. Remove protective plastic wrap.
6. Hold the screen, lift, and pull forward.
7. Remove log set by cutting plastic ties.
8. Carefully unwrap logs.
9. Check for any shipping damage. If heater or log is damaged, promptly inform your dealer where you bought the heater.
Leg Installation
1. Remove two screws in the upper corners of the screen (one on each side, see Figure 2). Lift and pull forward to remove.
2. Carefully lay heater on its back. Attach legs with hardware provided (see Figure 3).
Figure 1 - Vent-Free Stove
Figure 2 - Removing Screen
Figure 3 - Installing Legs
PRODUCT IDENTIFICATION
Logs
Screen
Heater Controls (Inside Panel)
Screws
3 Screws
www.usaprocom.com
7
200198-01A
AIR FOR COMBUSTION AND VENTILATION
WARNING: This heater shall
not be installed in a conned
space or unusually tight con­struction unless provisions are provided for adequate combus­tion and ventilation air. Read the following instructions to insure proper fresh air for this and other
fuel-burning appliances in your
home.
Today’s homes are built more energy efcient than ever. New materials, increased insulation and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in. During heating months, home owners want their homes as airtight as possible. While it is good to make your home energy efcient, your home needs to breathe. Fresh air must enter your home. All fuel-burning ap­pliances need fresh air for proper combustion and ventilation. Exhaust fans, replaces, clothes dryers and fuel burning appliances draw air from the house to operate. You must provide adequate fresh air for these appliances. This will insure proper venting of vented fuel-burning appli­ances.
WARNING: This heater shall
not be installed in a room or
space unless the required vol-
ume of indoor combustion air is provided by the method de­scribed in the National Fuel Gas
Code, ANSI Z223.1/NFPA 54, the International Fuel Gas Code, or
applicable local codes.
WARNING: If the area in which
the heater may be operated does
not meet the required volume for
indoor combustion air, combus­tion and ventilation air shall be provided by one of the methods described in the National Fuel
Gas Code, ANSI Z223.1/NFPA 54, the International Fuel Gas Code,
or applicable local codes.
VENTILATION AIR
Ventilation Air From Inside Building
This fresh air would come from an adjoining unconned space. When ventilating to an adjoining unconned space, you must provide two permanent openings: one within 12" of the ceiling and one within 12" of the oor on the wall connecting the two spaces (see options 1 and 2, Figure 2). You can also remove door into adjoining room (see option 3, Figure 4). Follow the National Fuel Gas Code, ANSI
Z223.1/NFPA 54, Air for Combustion and Ventilation for required size of ventilation
grills or ducts.
Figure 4 - Ventilation Air from Inside
Building
Or
Remove Door into Adjoining
Room, Option
3
Ventilation Grills
Into Adjoining Room,
Option 2
Ventilation
Grills Into Adjoining
Room,
Option 1
12"
12"
www.usaprocom.com
200198-01A
8
AIR FOR COMBUSTION AND VENTILATION
INSTALLATION
NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your primary heating system. Do not install this heater as your pri­mary heat source. If you have a central heating system, you may
run system’s circulating blower
while using heater. This will help circulate the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source.
WARNING: A qualied ser­vice person must install heater. Follow all local codes.
WARNING: Never install the
heater
• in a bedroom or bathroom
• in a recreational vehicle
• where curtains, furniture, cloth-
ing, or other ammable objects
are less than 48" from the front, top, or sides of the heater.
• in high trafc areas
• in windy or drafty areas
CAUTION: This heater cre­ates warm air currents. These currents move heat to wall sur­faces next to heater. Installing heater next to vinyl or cloth wall coverings or operating heater
where impurities (such as to­bacco smoke, aromatic candles, cleaning uids, oil or kerosene lamps, etc.) in the air exist, may
cause walls to discolor.
Ventilation Air From Outdoors
Figure 5 - Ventilation Air from Outdoors
Provide extra fresh air by using ventilation grills or ducts. You must provide two perma­nent openings: one within 12" of the ceiling and one within 12" of the oor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces. Follow the National Fuel
Gas Code, ANSI Z223.1/NFPA 54, Air for Combustion and Ventilation for required size
of ventilation grills or ducts. IMPORTANT: Do not provide openings
for inlet or outlet air into attic if attic has a thermostat-controlled power vent. Heated air entering the attic will activate the power vent. Rework worksheet, adding the space of the adjoining unconned space. The combined spaces must have enough fresh air to supply all appliances in both spaces.
Outlet Air
Ventilated Attic
Outlet Air
Inlet Air
Inlet Air
Ventilated
Crawl Space
To
Crawl
Space
To Attic
www.usaprocom.com
9
200198-01A
Figure 6 - Minimum Clearance to Wall
and Ceiling
IMPORTANT: Vent-free heaters add moisture to the air. Although this is benecial, installing heater in rooms without enough ventilation air may cause mildew to form too much moisture. See Air for Combustion and Ventilation, pages 7 and 8.
CHECK GAS TYPE
Be sure your gas supply is right for your heat­er. Otherwise, call dealer where you bought the heater for proper type heater.
CLEARANCES TO
COMBUSTIBLES
WARNING: You must main­tain the minimum clearances. If you can, provide greater clear-
ances from oor, ceiling, and
adjoining wall. Measure from outermost point of heater.
This heater is designed to sit directly on the oor or on a mantel base.
IMPORTANT: You must maintain minimum wall and ceiling clearances during installation. The minimum clearances are shown in Figure
6. Measure from outermost point of heater. If installed on carpeting or other combustible
material (other than wood) a oor protector made of metal or wood shall extend the full width and depth of the appliance.
Ceiling
12"
Min.
12"
Min.
48"
Min.
Side Wall
Side Wall
Floor
INSTALLATION
Minimum Wall and Ceiling
Clearances
A. Clearances from outermost point of heater
to any combustible side wall should not be less than 12".
B. Clearances from the heater to the ceiling
should not be less than 48".
C. Clearance from heater to back wall should
not be less than 6".
www.usaprocom.com
200198-01A
10
INSTALLATION
Gas Inlet / Gas esté
INLET GAS PRESSURE MAX 1/2 PSIG (3.5 KPa)
200110-01B 03/15
WARNING: Make sure Regulator Cap is in the appropriate position
as shown in diagrams. Installation and service should be done by qualified service technician only.
Natural Gas
When using natural gas: Make sure the cap is installed in the propane/LP inlet of regulator. Use thread sealant to assure there are no leaks.
Propane/LP Gas
When using propane/LP gas: Make sure the cap is installed in the natural gas (NG) inlet of regulator. Use thread sealant to assure there are no leaks.
ADVERTENCIA: Asegúrese la tapa del regulador esté en la posición adecuada,
como se muestra en los diagramas. La instalación y reparaciones deben ser realizadas por un técnico de servicio calificado solamente.
Gas Natural
Cuando se utiliza gas natural: Asegúrese de que la tapa está instalado en el propano/LP entrada del regulador.
Utilice sellador de roscas para asegurar que no haya fugas.
Propano/LP Gas
Cuando se utiliza el gas propano / LP:
Asegúrese de que la tapa está instalado en la entrada de gas natural (GN) del regulador.
Utilice sellador de roscas para asegurar que no haya fugas.
Correct Pilot Flame Pattern
Incorrect Pilot Flame Pattern
NG 3-3.5" WC
Natural Gas Shown
LP 8-11" WC
NG 3-3.5" WC
Natural Gas Shown
LP 8-11" WC
1/2 Glas
s
Height
1/2 Glas
s
Height
Yellow Tipping
Correct Burner Flame Pattern
Incorrect Burner Flame Pattern
LP
Blue Plunger
INSTALL SUPPLIED CAP IN FITTING
NOT BEING USED.
INSTALAR TAPA SUMINISTRADA MONTAJE NO SE UTILIZA.
NG
Yellow Plunger
This appliance may be installed in an aftermarket,* permanently located, manufactured (mobile) home, where not prohibited by local codes. This appliance is only for use with propane or natural gas. Field conversion by any other means including the use of a kit is not permitted.
WARNING: Make sure the supplied cap is installed in unused regulator fitting before connecting the correct gas supply line. WARNING: Do not use natural gas and propane gas together. CAUTION: Two gas line installations at the same time are prohibited. ADVERTENCIA: Asegúrese de que la línea no utilizado se conecta por primera vez antes de conectar la línea de suministro de gas correcta. ADVERTENCIA: No utilice el gas natural y el gas propano juntos. PRECAUCIÓN: Dos instalaciones de líneas de gas al mismo tiempo están prohibidos.
FOR PROPANE GAS SUPPLY
PARA LA FUENTE DE GAS DEL PROPANE
CAUTION: The heater requires an external regulator to reduce the LP tank pressure to a maximum of 14" W.C. Never connect this product directly to the supply tank. PRECAUCIÓN: El calentador requieres una externa regulador para reducir la presión del tanque de gas a un máximo de 14" W.C. Nunca conecte este producto directamente al tanque de suministro.
FOR NATURAL GAS SUPPLY
PARA LA FUENTE DE GAS DEL NATURAL
NOTICE: An additional gas regulator will be necessary if the local natural gas pressure exceeds the heater's rated maximum inlet pressure. If in doubt, contact the local gas utility. If natural gas inlet pressure exceeds 10" W.C., the safety pressure switch will activate. See owners manual for proper procedure to bypass the pressure switch.
AVISO: Un regulador de gas adicional será necesario si la presión del gas natural local excede de entrada nominal máxima del calentador presión. En caso de duda, póngase en contacto con la compañía de gas local. Si la presión de entrada de gas natural supera los 10" WC, el interruptor de presión de seguridad se activará. Consulte el manual del propietario para el procedimiento adecuado de derivación el interruptor de presión.
Procom Heating, Inc. U.S. Patent Information
This product may be covered by one or more of the following
United States patents: 8,915,239 8,851,065 8,764,436 8,757,202 8,757,139 8,752,541 8,568,136 8,545,216 8,517,718 8,516,878 8,506,290 8,465,277 8,317,511 8,297,968 8,281,781 8,241,034 8,235,708 8,152,515 8,011,920 7,967,006 7,967,007 7,654,820 7,730,765 7,677,236
7,607,426 7,434,447
Other patents pending.
TOLL-FREE Customer Care Number: 1-866-573-0674 Numero de Atención al Cliente GRATUITO: 1-866-573-0674 Visit our website for more information www.usaprocom.com
Visite nuestra página web para más informacion www.usaprocom.com
Figure 7 - Back of Stove
Gas Connection
Yellow Natural Gas Plunger Underneath Metal Cap
Blue Propane/LP Gas Plunger Underneath Dust Cover
Figure 8 - Gas Regulator
Insert Gas Fitting for Natural Gas
Insert Gas Fitting for Propane/LP Gas
GAS SELECTION
This appliance is factory preset for propane/LP gas. No changes are required for connecting to propane/LP.
Only a qualied installer or service
technician can perform gas selec­tion and connecting to gas supply.
CAUTION: Two gas line in-
stallations at the same time are
prohibited.
CAUTION: To avoid gas leak-
age for the gas not being used at the inlet of regulator, a qualied
installer or service technician must use supplied cap.
You will notice a color coded plunger on the inside of the regu­lator. This is normal. When the in-
let connection tting is inserted
and tightened, this plunger will
be pushed back by the tting making all of the adjustments for the gas being supplied. DO
NOT REMOVE THE PLUNGER.
The regulator will not work.
The inlet regulator is color coded
for identication of the correct gas type. Blue is for propane (LP gas) and yellow is for natural gas.
Fitting supplied with the product located in
the hardware bag. Fitting part number:
160960-02 (straight)
160960-03 (elbow)
Blue Dust Cover
DO NOT REMOVE
Blue Propane/LP
Plunger
Install Gas Fitting Here
FOR PROPANE/LP GAS
INSTALLATION: BLUE
1. Remove blue dust cover.
www.usaprocom.com
11
200198-01A
INSTALLATION
DO NOT use an off the shelf 3/8" NPT pipe plug. This will damage the plungers located inside the regulator.
DO NOT try to remove the plung­ers from inside the regulator. The
plunger will be pushed back as the tting is installed.
Make sure the type of gas being used is correct. Check to make sure the connection tting is in
the correct inlet on the regula­tor. Refer to Connecting to Gas Supply, page 12.
If you are using natural gas and the pilot will not light, see Troubleshooting, page 22.
Use only the cap supplied on the regulator. Do not use an off the shelf pipe plug. This can damage the plunger. The supplied regula­tor cap is designed so it will not engage the unused gas type.
4. Apply thread sealant to the threads on the connection tting. While pushing in, rotate the tting clockwise until the threads engage the regulator. After the tting has been hand tightened into the regulator use a wrench to complete tightening of the tting. Install additional tting to connect to the house supply.
Blue Dust Cover
Metal Cap
Metal Cap
DO NOT REMOVE
Yellow Natural Gas Plunger
Install Gas Fitting Here
2. Apply thread sealant to the threads on the connection tting. While pushing in, rotate the tting clockwise until the threads engage the regulator. After the tting has been hand tightened into the regulator use a wrench to complete tightening of the tting. Install additional tting to connect to the house supply.
FOR NATURAL GAS (NG) INSTALLATION: YELLOW
1. Remove the blue dust cover from the regulator.
2. Remove the metal cap installed over the NG regulator inlet.
3. Install metal cap over LP/Propane regulator inlet. This will keep debris out of regulator.
www.usaprocom.com
200198-01A
12
INSTALLATION
CONNECTING TO GAS SUPPLY
CAUTION: For natural gas,
check your gas line pressure before connecting heater to gas line. Gas line pressure must be
no greater than 9" of w.c. If gas line pressure is higher, heater
regulator damage could occur.
CAUTION: Avoid damage to regulator. Hold gas regulator with wrench when connecting
into gas piping and/or ttings.
CAUTION: Use pipe joint sealant that is resistant to gas
(Propane/LP or Natural Gas).
Before installing heater, make sure you have the items listed below:
• external regulator for propane/LP unit only (supplied by installer)
• piping (check local codes)
• sealant (resistant to natural gas and pro­pane/LP gas)
• equipment shutoff valve*
• test gauge connection*
• sediment trap
• tee joint
• pipe wrench
• exible gas hose (check local codes)
* A CSA design-certied equipment shutoff valve with 1/8" NPT tap is an acceptable al­ternative to test gauge connection. Purchase the optional CSA design certied equipment shutoff valve from your dealer.
Typical Inlet Pipe Diameters
Use 1/2" black iron pipe or greater. Installa­tion must include an equipment shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 10, page 13).
IMPORTANT: Install an equipment shutoff valve in an accessible location. The equip­ment shutoff valve is for turning on or shutting off the gas to the appliance.
WARNING: A qualied ser­vice technician must connect heater to gas supply. Follow all local codes.
WARNING: This appliance
requires a 3/8" NPT (National Pipe Thread) inlet connection to
the pressure regulator.
WARNING: For natural gas, Never connect heater to private
(non-utility) gas wells. This gas is commonly known as wellhead
gas.
CAUTION: For propane/LP gas, never connect heater direct­ly to the gas supply. This heater requires an external regulator
(not supplied). Install the external regulator between the heater and
propane/LP gas supply. Gas sup­plier provides external regulator for natural gas. The installer provides the external regulator
for propane/LP gas.
WARNING: Do not over­tighten gas connections.
CAUTION: Use only new,
black iron or steel pipe. Inter­nally tinned copper tubing may be used in certain areas. Check
your local codes. Use pipe of 1/2" diameter or greater to allow proper gas volume to heater. If pipe is too small, undue loss of pressure will occur.
www.usaprocom.com
13
200198-01A
INSTALLATION
Figure 10 - Gas Connection
Figure 9 - Gas Regulator Location and
Gas Line Access Into Stove Cabinet
* Purchase the optional CSA design-certied equipment shutoff valve from your dealer.
Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves.
For propane/LP installations, the installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11" and 14" of w.c. If you do not re­duce incoming gas pressure, heater regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure
11. Pointing the vent down protects it from freezing rain or sleet.
For both gas types, install sediment trap in supply line as shown in Figure 10. Place sediment trap where it is within reach for cleaning. Place sediment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into heater controls. If sedi­ment trap is not installed or is installed wrong, heater may not run properly.
Figure 11 - External Regulator
with Vent Pointing Down
External Regulator with Vent Pointing Down
Propane/LP Supply Tank
Equipment Shutoff Valve
Ground Joint Union
3/8" NPT
Pipe Nipple
Tee Joint
Reducer Bushing to 1/8" NPT
1/8" NPT Plug Tap
Test Gauge Connection*
Sediment
Trap
Tee Joint
Pipe Nipple
Gap
3" Minimum
Natural Gas
From Gas Meter (5" W.C.** to 9" W.C. Pressure)
Propane/LP
From External Regulator (11" W.C.** to 14" W.C. Pressure)
WARNING: Test all gas piping
and connections for leaks after
installing or servicing. Correct
all leaks at once (see page 14).
Gas Inlet Regulator Connection
www.usaprocom.com
200198-01A
14
INSTALLATION
Figure 12 - Equipment Shutoff Valve
CHECKING GAS CONNECTIONS
Open
Closed
Equipment Shutoff Valve
WARNING: Never use an open
ame to check for a leak. Apply a noncorrosive leak detection uid to all joints. If bubbles form, there is a leak. Correct all leaks
at once.
WARNING: Test all gas piping
and connections for leaks after
installing or servicing. Correct
all leaks at once.
PRESSURE TESTING GAS SUPPLY PIPING SYSTEM
Test Pressures In Excess Of 1/2 PSIG (3.5 kPa)
1. Disconnect heater with its appliance main gas valve (control valve) and equipment shutoff valve from gas supply piping sys­tem. Pressures in excess of 1/2 PSIG will damage heater regulator.
2. Cap off open end of gas pipe where equip­ment shutoff valve was connected.
3. Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas or opening main gas
valve located on or near gas meter for natural gas or using compressed air.
4. Check all joints of gas supply piping sys­tem. Apply noncorrosive leak detection uid to all joints. If bubbles form, there may be a leak.
5. Correct all leaks at once.
6. Reconnect heater and equipment shutoff valve to gas supply. Check reconnected ttings for leaks.
Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa)
1. Close equipment shutoff valve (see Fig­ure 12).
2. Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas or opening main gas valve located on or near gas meter for natural gas or using compressed air.
3. Check all joints from gas meter to equip­ment shutoff valve for natural gas or propane/LP supply to equipment shutoff valve for propane/LP (see Figure 13 or
14). Apply a noncorrosive leak detection uid to all joints. Bubbles forming show a leak.
4. Correct all leaks at once.
Control Valve Location
Control Valve Location
Equipment Shutoff Valve
Equipment Shutoff Valve
External Regulator
Propane/LP Supply Tank
Figure 13 - Checking Gas Joints for
Propane/LP Gas
Figure 14 - Checking Gas Joints for
Natural Gas
Gas Meter
www.usaprocom.com
15
200198-01A
INSTALLATION
PRESSURE TESTING HEATER GAS CONNECTIONS
1. Open equipment shutoff valve (see Figure 12, page 14).
2. Open main gas valve located on or near gas meter for natural gas or open pro­pane/LP supply tank valve.
3. Make sure control knob of heater is in the OFF position.
4. Check all joints from equipment shutoff valve to control valve (see Figure 13 or
14, page 14). Apply a noncorrosive leak detection uid to all joints. Bubbles form­ing show a leak.
5. Correct all leaks at once.
6. Light heater (see Lighting Instructions on page 17). Check all other internal joints for leaks.
7. Turn off heater (see To Turn Off Gas Ap- pliance, page 18).
AAA
Battery
Positive
UP
BATTERY INSTRUCTIONS
CAUTION: Do not dispose of
batteries in re, batteries may explode or leak.
• Battery is included.
• Remove battery when depleted.
• Only install or replace with a AAA battery.
• Be sure to observe proper polarity (+/-) when installing or replacing the battery. Damage due to improper battery installation may void the warranty on the product.
• For long periods of non-operation, remove battery from all components for safety.
Unscrew ignitor cap and install a AAA battery with the + pointing out. Replace cap.
Figure 15 - Installing Battery in Ignitor
www.usaprocom.com
200198-01A
16
INSTALLATION
Use only logs supplied with heater. Each
log is marked with a number. This number
will help you to identify the logs when installing. Do not place any decorative
cinders on logs or burner.
1. Remove the packing material from the logs. The log number is marked on the back of each log.
Refer to Figure 16 for log placement.
2. Place pins on log #1 into two slots in the rear bracket.
3. Place pin on log #2 into slot on left side of the middle bracket.
4. Place pin on log #3 into slot on right side of the middle bracket.
5. Install hole in log #4 onto pin on the left side of log #1, with one end resting on log #2.
7. Install hole in log #5 onto pin on the right side of log #1, with one end resting on log #3.
IMPORTANT: Make sure logs do not cover any burner ports. It is very important to install the logs exactly as instructed. Do not modify logs. Use only logs supplied with heater.
WARNING: Failure to posi­tion the parts in accordance with these diagrams or failure
to use only parts specically
approved with this heater may result in property damage or personal injury.
CAUTION: After installation, and periodically thereafter,
check to ensure that no ame
comes in contact with any log.
With the heater set to high, check to see if ames contact any log. If
so, reposition logs according to the log installation instructions in this manual. Flames contact­ing logs will create soot.
It is very important to install the logs ex­actly as instructed. Do not modify logs.
INSTALLING LOGS
Rear Bracket
Log #1
Log #2
Log #4
Log #5
Log #3
Middle Bracket
Figure 16 - Log Installation
www.usaprocom.com
17
200198-01A
OPERATION
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING: If you do not fol­low these instructions exactly, a re or explosion may result caus­ing property damage, personal injury or loss of life.
A. This appliance has a pilot which must
be lighted by hand. When lighting the
pilot, follow these instructions exactly.
B. BEFORE LIGHTING smell all around
the appliance area for gas. Be sure to
smell next to the oor because some
gas is heavier than air and will settle
on the oor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do
not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the re department.
C. Use only your hand to push in or turn
the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualied service technician. Force or attempted repair may result in a re or
explosion.
D. Do not use this appliance if any part
has been under water. Immediately call a qualied service technician to inspect
the appliance and to replace any part of the control system and any gas control
which has been under water.
WARNING: You must oper-
ate this heater with the screen
in place. Make sure screen is installed before running heater.
NOTICE: During initial operation of
new heater, burning logs will give off a paper-burning smell. Orange ame will also be present. Open
damper or window to vent smell. This will only last a few hours.
1. STOP! Read the safety information above.
2. Make sure equipment shutoff valve is fully open.
3. Turn control knob clockwise to the OFF position.
4. Wait ve (5) minutes to clear out any gas. Then smell for gas around heater and near the oor. If you smell gas, STOP! Follow "B" in the safety information above. If you do not smell gas, go to the next step.
5. Turn control knob counterclockwise to the PILOT position. Press in control knob for ve (5) seconds.
Note: The rst time that the heater is oper-
ated after connecting the gas supply, the
control knob should be pressed for about thirty (30) seconds. This will allow air to bleed from the gas system. If pilot does not stay lit, refer to Troubleshooting, pages 22
though 25. Also contact a qualied service
technician or gas supplier for repairs. Until repairs are made, light pilot with match.
• If control knob does not pop up when released, contact a qualified service technician or gas supplier for repairs.
6. With control knob pressed in, push down and release ignitor button. This will light pilot. The pilot is attached to the rear of the burner. If needed, keep pressing ignitor button until pilot lights.
LIGHTING INSTRUCTIONS
Ignitor Button
Control Knob
Figure 17 - Ignitor Button and Control
Knob Locations
www.usaprocom.com
200198-01A
18
OPERATION
THERMOSTAT CONTROL OPERATION
The thermostatic control used on this model differs from standard thermostats. You set standard thermostats to a specic temperature such as 72 degrees. The thermostat used on this heater senses the room temperature. At times the room may exceed the set temperature. If so, the burner will shut off. The burner will cycle back on when room temperature drops below the set temperature. The control knob can be set to any comfort level between Low (1) and HIGH (5).
Shutting Off Heater
Turn control knob clockwise to the OFF position.
Shutting Off Burner Only (pilot
stays lit )
Turn control knob clockwise to the PILOT position.
1. Remove 2 screws securing screen to stove. Carefully lift and pull screen forward to remove.
2. Follow steps 1 through 5 under Lighting Instructions, page 17.
3. With control knob in PILOT position, strike match, and hold near pilot. Press in control knob; pilot should light.
4. Keep control knob pressed in for 30 sec­onds after lighting pilot. After 30 seconds, release control knob.
5. Make sure the heater screen is in place before operating heater.
TO TURN OFF GAS TO APPLIANCE
MANUAL LIGHTING PROCEDURE
Note: If pilot does not stay lit, refer to Troubleshooting, page 22. Also contact a
qualied service technician or gas supplier
for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure.
7. Keep control knob pressed in for 30 sec­onds after lighting pilot. After 30 seconds, release control knob.
Note: If pilot goes out, repeat steps 3
through 7. This heater has a safety inter­lock system. Wait one (1) minute before lighting pilot again.
8. Turn control knob counterclockwise to the desired heating level. The main burner should light. Set control knob to any heat level between HI (5) and LO (1).
Note: Please wait one minute after shut-
ting off replace to allow the control valve
to reset before starting again.
CAUTION: Do not try to ad-
just heating levels by using the
equipment shutoff valve.
WARNING: If input gas
type is NG, make sure NG pilot burner ignites. If input gas type is LP, make sure LP pilot burner
ignites.
Figure 18 - Pilot
Pilot Air Inlet Hole
Natural Gas Burner
Propane/LP Gas Burner
Thermocouple
Pilot Air Inlet Hole
Ignitor Electrode
www.usaprocom.com
19
200198-01A
INSPECTING BURNERS
IMPORTANT: Owner’s should check pilot ame pattern and burner ame pattern often. Incorrect ame patterns indicate the need for cleaning (see Care and Maintenance,
page 20 or service.
WARNING: Only a qualied service person should service and repair heater. This includes maintenance requiring replacement or alteration of components.
PILOT FLAME PATTERN
Figure 19 shows a correct pilot ame pattern. Figure 20 shows an incorrect pilot ame pat­tern. The incorrect pilot ame is not touching the thermocouple. This will cause the ther­mocouple to cool, which shuts the heater off.
If pilot ame pattern is incorrect, as shown in Figure 20
• turn heater off (see To Turn Off Gas to Ap- pliance, page 18)
• see Troubleshooting pages 22 through 25.
WARNING: If yellow tipping
occurs, your heater could produce
increased levels of carbon mon­oxide. If the burner ame pattern
shows yellow tipping, follow in-
structions at bottom of this page.
Notice: Do not mistake orange ames with yellow tipping. Dirt or other ne particles enter
the heater and burn causing brief patches of
orange ame.
Approx. 3"-6" Above Top of Logs
Approx. 3"-6" Above Top of Logs
More Than 8" Above Top of Logs
Figure 21 - Correct Burner Flame Pattern
Figure 22 - Incorrect Burner Flame
Pattern
BURNER FLAME PATTERN
Figure 21 shows a correct burner ame pattern. Figure 22 shows an incorrect burner ame pattern. If burner ame pattern is incorrect as shown in Figure 22:
• turn heater off (see To Turn Off Gas to Appliance, page 18).
• see Troubleshooting pages 22 through 25.
BURNER PRIMARY AIR HOLES
Air is drawn into the burner through the holes in the tting at the entrance to the burner. These holes may become blocked with dust or lint. Periodically inspect these holes for any blockage and clean as necessary. Blocked air holes will create soot.
Figure 19 - Correct Pilot Flame Pattern
(Natural Gas shown)
Figure 20 - Incorrect Pilot Flame Pattern
(Natural Gas shown)
NG
3-3.5" WC
Natural Gas
Shown
LP
8-11" WC
NG
3-3.5" WC
Natural Gas
Shown
LP
8-11" WC
www.usaprocom.com
200198-01A
20
CARE AND MAINTENANCE
WARNING: Turn off heater and let cool before servicing.
CAUTION: You must keep control areas, burner, and circulating
air passageways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a qualied service techni-
cian. Heater may need more frequent cleaning due to excessive lint
from carpeting, bedding material, pet hair, etc.
WARNING: Failure to keep the primary air opening(s) of the
burner(s) clean may result in sooting and property damage.
MAIN BURNER
Periodically inspect all burner ame holes with the heater running. All slotted burner ame holes should be open with yellow ame pres­ent. All round burner ame holes should be open with a small blue ame present. Some
burner ame holes may become blocked by debris or rust, with no ame present. If so, turn off the heater and let it cool, and remove blockage or replace burner. Blocked burner ame holes will create soot.
Figure 23 - Burner and Injector Holder
Injector
Burner Tube
Primary Air Inlet Holes
BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLE
We recommend that you clean the unit ev­ery 2,500 hours of operation or every three months. We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt. To clean these parts we recommend using compressed air no greater than 30 PSl. Your local computer store, hardware store, or home center may carry compressed air in a can. You can use a vacuum cleaner in the blow position. If us­ing compressed air in a can, please follow the directions on the can. If you don’t follow directions on the can, you could damage the pilot assembly.
1. Shut off the unit, including the pilot. Allow
the unit to cool for at least thirty minutes.
2. Inspect burner, pilot and primary air inlet
holes on injector for dust and dirt (see Figure 23).
3. Blow air through the ports/slots and holes
in the burner. Also clean the pilot assembly.
4. Check the injector holder located at the end of the burner tube again. Remove any large particles of dust, dirt, lint, or pet hair with a soft cloth or vacuum cleaner nozzle.
5. Blow air into the primary air holes on the injector holder.
6. In case any large clumps of dust have now been pushed into the burner. Repeat steps 3 and 4.
www.usaprocom.com
21
200198-01A
Use a vacuum cleaner, pressurized air, or a small, soft bristled brush to clean.
A yellow tip on the pilot ame indicates dust and dirt in the pilot assembly. There is a small pilot air inlet hole about 2" from where the pilot ame comes out of the pilot assembly (see Figure 24). With the unit off, lightly blow air through the air inlet hole. You may blow through a drinking straw if compressed air is not available.
CARE AND MAINTENANCE
ODS/PILOT
CABINET
Air Passageways
Use a vacuum cleaner or pressurized air to clean.
Exterior
• Use a soft cloth dampened with a mild soap and water mixture.
• Wipe the cabinet to remove dust.
LOGS
• If you remove logs for cleaning, refer to Installing Logs, page 16, to properly replace logs.
• Replace log(s) if broken or chipped (dime­size or larger).
Figure 24 - Pilot Inlet Air Hole
Pilot Air Inlet Hole
Natural Gas Burner
Propane/LP Gas Burner
Thermocouple
Pilot Air Inlet Hole
Ignitor Electrode
www.usaprocom.com
200198-01A
22
TROUBLESHOOTING
WARNING: If you smell gas:
• Shut off gas supply.
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. Fol­low the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the re department.
WARNING: Only a qualied service technician should service and repair heater. Make sure that power is turned off before proceeding. Turn off and let cool before servicing.
CAUTION: Never use a wire, needle, or similar object to clean
ODS/pilot. This can damage ODS/ pilot unit.
IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning sup­plies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors.
Note: All troubleshooting items are listed in order of operation.
NG
Figure 24 - Gas Regulator Pressure
Switch
Pressure Switch Set Screw
Pressure Switch
When using natural gas (NG), there is a pressure switch that acts to turn off the gas ow to the pilot if the inlet pressure exceeds 9" WC. This is to prevent the operation of the unit on the wrong gas (propane/LP). If your natural gas supply exceeds 9" WC the unit will not operate. Either contact your gas supplier to check and adjust the inlet pressure or a qualied service technician can bypass the pressure switch.
Before attempting to bypass the pressure switch, make sure the type of gas being used is correct. Check to make sure the connection tting is in the correct inlet on the regulator. Refer to Connecting to Gas Supply, page 12.
Only a qualied installer should bypass the pressure switch. To bypass the pressure switch locate the set screw on the regulator. Use a small at bladed screw driver to turn the set screw counterclockwise 2 turns. This will bypass the pressure switch function.
Problem Possible Cause Corrective Action
Using natural gas and pilot will not light.
Inlet pressure exceeds 9" WC. Bypass pressure switch. See
instructions below.
The entire gas delivery piping including con­nections inside the heater should be leak tested by the qualied installer. After leak testing the qualied installer should light the appliance. Refer to the correct ame pattern as illustrated on page 18. All ame patterns should be safely inside the product. If for any reason they are not, stop use of the appliance and call for repairs.
www.usaprocom.com
23
200198-01A
Problem Possible Cause Corrective Action
When ignitor button is pressed in, there is no spark at ODS/pilot
1. Ignitor electrode is posi­tioned wrong. Ignitor elec­trode is broken.
2. Ignitor electrode is not con­nected to ignitor cable.
3. Ignitor cable is pinched or wet.
4 Broken ignitor cable.
5. Bad piezo ignitor.
6. Low battery.
1. Replace electrode.
2. Replace ignitor cable
3. Free ignitor cable if pinched by any metal or tubing. Keep ignitor cable dry.
4. Replace ignitor cable.
5. Replace piezo ignitor.
6. Replace battery.
When ignitor button is pressed in there is a spark at ODS/pilot but no ignition.
1. Gas supply is turned off or equipment shutoff valve is closed.
2. Control knob not fully pressed in while pressing ignitor button.
3. Air in gas lines (new instal­lation or recent gas interrup­tion).
4. ODS / pilot is clogged.
5. Incorrect inlet gas pressure or inlet regulator is damaged.
6. Control knob not in PILOT position.
7. Depleted gas supply (pro­pane).
1. Turn on gas supply or open equipment shutoff valve.
2. Fully press in control knob while pressing ignitor button.
3. Continue holding down con­trol knob. Repeat igniting op­eration until air is removed.
4.
Clean ODS/pilot (see Care and Maintenance, page 20) or
replace ODS/pilot assembly.
5. Check inlet gas pressure or replace inlet gas regulator.
6. Turn control knob to PILOT position.
7. Contact local propane/LP gas company.
ODS/pilot lights but ame goes out when control knob is released.
1. Control knob is not fully pressed in.
2. Control knob is not pressed in long enough.
3. Equipment shutoff valve is not fully open.
4. Thermocouple connection is loose at control valve.
5. Pilot flame not touching thermocouple, which allows thermocouple to cool, caus­ing pilot ame to go out. This problem could be caused by one or both of the following:
A) Low gas pressure B) Dirty or partially clogged
ODS/pilot
6. Thermocouple damaged.
7. Control valve damaged.
1. Press in control knob fully.
2. After ODS/pilot lights, keep control knob pressed in 30 seconds.
3. Fully open equipment shutoff valve.
4. Hand tighten until snug, and then tighten 1/4 turn more.
5. A) Contact local natural or propane/LP gas company
B) Clean ODS/pilot (see
Care and Maintenance, page 20) or replace ODS/ pilot assembly
6. Replace thermocouple.
7. Replace control valve.
TROUBLESHOOTING
www.usaprocom.com
200198-01A
24
TROUBLESHOOTING
Problem Possible Cause Corrective Action
Burner(s) does not light after ODS/pilot is lit
1. Burner orice is clogged.
2. Burner orice diameter is too small.
3. Inlet gas pressure is too low.
1. Clean burner orifice (see Care and Maintenance, page 20) or replace burner orice.
2. Replace burner orice.
3. Contact local gas supplier.
Delayed ignition of burner(s).
1. Manifold pressure is too low.
2. Burner orice is clogged.
1. Contact local gas supplier.
2. Clean burner (see Care and Maintenance, page 20) or replace burner orice.
Burner backring during combustion.
1. Burner orice is clogged or damaged.
2. Burner is damaged.
3. Gas regulator is damaged.
1. Clean burner orifice (see Care and Maintenance, page 20) or replace burner orice.
2. Contact dealer or customer service.
3. Replace gas regulator.
High yellow ame during burner combustion.
1. Not enough air.
2. Gas regulator is defective.
3. Inlet gas pressure is too low.
1. Check burner for dirt and debris. If found, clean burner (see Care and Maintenance, page 20).
2. Replace gas regulator.
3. Contact local gas supplier.
Gas odor during com­bustion.
1. Foreign matter between control valve and burner.
2. Gas leak. (See Warning Statement at top of page 22).
1. Take apart gas tubing and remove foreign matter.
2. Locate and correct all leaks (see Checking Gas Connec- tions, page 14).
Slight smoke or odor during initial operation.
1. Residues from manufactur­ing process.
1. Problem will stop after a few hours of operation.
Heater produces a whis­tling noise when burner is lit.
1. Turning control knob to high position when burner is cold.
2. Air in gas line.
3. Air passageways on heater are blocked.
4. Dirty or partially clogged burner orice.
1. Turn control knob to low position and let warm up for a minute.
2. Operate burner until air is removed from line. Have gas line checked by local gas supplier.
3 Observe minimum installa-
tion clearances (Figure 6, page 9)
4 Clean burner (see Care and
Maintenance, page 20) or replace burner orice.
Heater produces a click­ing/ticking noise just after burner is lit or shut off.
1. Metal is expanding while heating or contracting while cooling.
1. This is common with most heaters. If noise is exces­sive, contact qualied ser­vice technician.
www.usaprocom.com
25
200198-01A
TROUBLESHOOTING
Problem Possible Cause Corrective Action
White powder residue forming within burner box or on adjacent walls or furniture.
1. When heated, the vapors from furniture polish, wax, carpet cleaners, etc., turn into white powder residue.
1. Turn heater off when using furniture polish, wax, carpet cleaner or similar products.
Heater produces un­wanted odors.
1.
Heater is burning vapors from paint, hair spray, glues, etc. See IMPORTANT statement, page 22.
2. Gas leak. See Warning State- ment at the top of page 22.
3 Low fuel supply.
1. Ventilate room. Stop using odor causing products while heater is running.
2. Locate and correct all leaks (see Checking Gas Connec- tions, page 14).
3. Rell supply tank (Propane/ LP models).
Heater shuts off in use (ODS operates).
1. Not enough fresh air is avail­able.
2. Low line pressure.
3. ODS/pilot is partially clogged.
1. Open window and/or door for ventilation.
2. Contact local gas supplier.
3. Clean ODS/pilot (see Care and Maintenance, page 20).
Gas odor exists even when control knob is in OFF position.
1. Gas leak. See Warning Statement at top of page 22.
2. Control valve is defective.
1. Locate and correct all leaks (see Checking Gas Connec- tions, page 14).
2. Replace control valve.
Moisture/condensation noticed on windows.
1. Not enough combustion/ ventilation air.
1. Refer to Air for Combus- tion and Ventilation require­ments, page 7.
SERVICE HINTS
When Gas Pressure Is Too Low
• pilot will not stay lit
• burners will have delayed ignition
• replace will not produce specied heat
• propane/LP gas supply might be low (propane/LP units only) You may feel your gas pressure is too low. If so, contact your local gas supplier.
TECHNICAL SERVICE
You may have further questions about installation, operation, or troubleshooting. If so, contact ProCom Heating, Inc. at 1-866-573-0674.
When calling, please have your model and serial numbers of your heater ready.
ACCESSORIES
Purchase these heater accessories from your local dealer. If they can not supply these acces­sories, contact ProCom Heating, Inc. at 1-866-573-0674 for information.
EQUIPMENT SHUTOFF VALVE
For all models. Equipment shutoff valve with 1/8" NPT tap.
www.usaprocom.com
200198-01A
26
PARTS
MODEL QNSD250T
7
8
6
1
2
3
4
12
13
11
15
14
5
9
10
www.usaprocom.com
27
200198-01A
PARTS
MODEL QNSD250T
This list contains replaceable parts for your heater. When ordering replacement parts, follow the instructions listed under Replacement Parts of this manual.
Item Part # Description Qty
1 BL016-07-02 Blower Mount Panel 1 2 SL005-01A Blower Bracket 2 3 QDB29100B Screen 1 4 QD250T106 Door 1 5 ND0310A-400-PU2 ODS Pilot 1 6 PIMDN1-01 Ignitor 1 7 RVD88-Y-4/9 Regulator 1 8 STL1001A Control Valve 1 9 QB46000C-R Leg 1 1
10 QB46000C-L Leg 2 1
FB28D500-B Log Set 1 11 FB28D501-B Log 1 1 12 FB28D502-B Log 2 1 13 FB28D503-B Log 3 1 14 FB28D504-B Log 4 1 15 FB28D505-B Log 5 1
Parts Available - Not Shown
QD250T001 Hardware Package 1
GB/T845-4.8*16 Self Tapping Screw 6
PCAM-012 AAA Battery 1
160960-01 Metal Regulator Cap 1
REPLACEMENT PARTS
Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.
PARTS UNDER WARRANTY
Contact authorized dealers of this product. If they can’t supply original replacement parts, call Customer Service toll free at 1-866-573-0674 for referral information.
When calling Customer Service or your dealer, have ready:
• Your name
• Your address
• Model and serial number of your heater
• How heater was malfunctioning
• Type of gas used (Propane/LP or Natural gas/NG)
• Purchase date
• Usually, we will ask you to return the defec­tive part to the factory
PARTS NOT UNDER WARRANTY
Contact authorized dealers of this product. If they can’t supply original replacement part(s) call Customer Service toll free at 1-866-573-0674 for referral information.
When calling Customer Service have ready:
• Model number of your heater
• The replacement part number
200198-01 Rev. A 04/15
WARRANTY
KEEP THIS WARRANTY
Model _______________________________ Serial No. ____________________________ Date Purchased _______________________
Keep receipt for warranty verication.
ProCom Heating, Inc. Bowling Green, KY 42101 www.usaprocom.com 1-866-573-0674
REGISTER YOUR PRODUCT AT WWW.USAPROCOM.COM
IMPORTANT: We urge you to register your product within 10 days of date of installation, complete
with entire serial number which can be found on the rating plate. Please ll out the warranty infor­mation above for your personal records. Retain this manual for future reference.
Always specify model and serial numbers when communicating with customer service.
We reserve the right to amend these specications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied.
LIMITED WARRANTY
ProCom Heating, Inc. warrants this product to be free from defects in materials and components for ONE (1) year from the date of rst purchase, provided that the product has been properly installed by a qualied installer in accordance with all local codes and instructions furnished with the unit, operated and main­tained in accordance with all applicable instructions. To make a claim under this warranty, the Bill of Sale or canceled check must be presented.
RESPONSIBILITY OF OWNER
This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required to restore this heater to proper operating condition. Warranty part(s) MUST be obtained through ProCom Heating, Inc. who will provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty.
IMPORTANT: The heater MUST be installed by a qualied installer in accordance with all local codes
and instructions furnished with the unit or the warranty is voided.
WHAT IS NOT COVERED
This warranty does not apply to parts that are not in original condition because of normal wear and tear or parts that fail or become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation. Travel, diagnostic cost, labor, transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner.
TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT, THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES. INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO ONE (1) YEARS ON ALL COMPONENTS FROM THE DATE OF FIRST PURCHASE. PROCOM HEATING, INC.'S LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND PROCOM HEAT­ING, INC. SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT. INCIDENTAL OR CONSEQUENTIAL DAMAGES.
Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of accidental or consequential damages, the above limitation on implied warranties, or exclusion or limitation on damages may not apply to you.
This warranty gives you specic legal right, and you may also have other rights that vary from state to state.
Loading...