Procom PC32VFC, PC36VFC User Manual

VENT-FREE GAS FIREBOX
Model # PC32VFC & PC36VFC
CAUTION – FOR YOUR SAFETY
WARNING: IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED
EXACTLY, A FIRE MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR LOSS OF LIFE.
– Do not store or use gasoline or other flammable vapors and liquids in vicinity of
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance. Do not touch any electrical switch; do not use any phone in your building. Immediately call your gas supplier from a neighbor’s phone. Follow the gas
supplier’s instructions.
If you cannot reach your gas supplier, call the fire department.
– Installation and service must be performed by a qualified installer, service agency
or the gas supplier.
FOR USE ONLY WITH A LISTED GAS-FIRED UNVENTED DECORATIVE ROOM HEATER NOT TO EXCEED 40,000 BTU/HR. DO NOT BUILD A WOOD FIRE.
Carefully review the instructions supplied with the decorative type unvented room heater for the minimum fireplace size requirement. DO NOT INSTALL AN APPLIANCE IN THIS FIREBOX UNLESS THIS FIREBOX MEETS THE MINIMUM DIMENSIONS REQUIRED FOR THE INSTALLATION.
This firebox has been tested and approved under ANSI Z21.91 for use with any ANSI Z21.11.2 approved gas logs.
INSTALLER : Leave this manual with the appliance CONSUMER : Retain this manual for future reference
Questions about installation, operation, or troubleshooting? Before returning to your retailer, contact our
customer service department at 1-877-886-5989, 8:00 a.m.- 4:30p.m., EST, Monday-Friday or e-mail customerservice@usaprocom.com.
PC-PC36VFC-701-1101
TABLE OF CONTENTS
Important Safety Information ......................................................................................................................................... 3
Product Feature ............................................................................................................................................................. 4
Local Codes ................................................................................................................................................................... 4
Locating Firebox ............................................................................................................................................................ 5
Installation ..................................................................................................................................................................... 6
Replacement Parts ...................................................................................................................................................... 11
Accessory .................................................................................................................................................................... 12
WARNING: READ THE INSTALLATION & OPERATION INSTRUCTIONS BEFORE USING THIS APPLIANCE
IMPORTANT: Read instructions and warnings carefully before starting installation. Failure to follow these instructions
may result in a possible fire hazard and will void the warranty.
PRODUCT SPECIFICATIONS
32’ and 36” Models
Figure 1
Model A B C D E F G H I J
PC32VFC 2.381" 18.515" 19° 24.060" 7.567" 21.382" 20.718" 31.732" 29.323" 34.25”
PC36VFC 2.397" 18.870" 25° 28.770" 6.622" 26.740" 25.949" 36.031" 33.630" 42.50”
2
IMPORTANT SAFETY INFORMATION
INSTALLER: DO NOT DISCARD THIS MANUAL – LEAVE FOR HOMEOWNER’S FUTURE REFERENCE.
IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, operate, or service this
fireplace. Improper use of this fireplace can cause serious injury or death from burns, fire, explosion, electrical shock, and carbon monoxide poisoning.
Only a qualified installer, service agent, or local gas supplier may install and service this product.
WARNING: Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other
appliance.
CARBON MONOXIDE POISONING: Early signs of carbon monoxide poisoning resemble the flu with headaches, dizziness, or nausea. If you have these signs, the fireplace may not be working properly. Get fresh air immediately! Have fireplace serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease, people who are anemic, those under the influence of alcohol, and those living in high altitudes.
WARNING: Any change to this fireplace or its controls can be dangerous.
WARNING: Do not allow fans to blow directly into fireplace. Avoid any drafts that alter burner flame patterns.
WARNING: Do not use a blower insert, heat exchange insert or other accessory not approved for use with this
firebox.
Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies. Do not place clothing or other flammable material on or near the appliance. Never place any objects in the fireplace. Fireplace becomes very hot when running fireplace. Keep children and adults away from hot surfaces to avoid burns or clothing ignition. Fireplace will remain hot for a time after shutdown. Allow surfaces to cool before touching. Carefully supervise young children when they are in the room with the firebox.
You must operate this fireplace with the fireplace screen and hood if provided, in place. Make sure these parts are in place and screens are closed before running firebox. The supplied hood must not be modified or replaced with a hood that may be provided with an unvented room heater (log set) selected.
COMBUSTION AND MAKE-UP AIR
Follow the information concerning provisions for adequate combustion and vent located in the unvented room heater’s installation instructions.
3
1. Do not place Propane/LP supply tank(s) inside any structure. Propane/LP supply tank(s) must be placed outdoors.
2. Do not use this firebox as a wood-burning fireplace. Use only decorative unvented room heaters (log set).
3. Keep all air openings in front and bottom of fireplace clear and free of debris. This will ensure enough air for proper combustion.
4. Do not run fireplace:
Where flammable liquids or vapors are used or stored.  Under dusty conditions.
5. Before using furniture polish, wax, carpet cleaner, or similar products, turn fireplace off. If heated, the vapors from these products may create a white powder residue within burner box or on adjacent walls or furniture.
6. Do not use firebox if it has been under water due to shock hazard that could result with the blower accessory (if installed) in place.
7. Turn firebox off and let cool before servicing. Only a qualified service person should service and repair firebox.
8. Operating firebox above elevations of 4,500 feet could cause pilot outage.
9. To prevent performance problems, do not use propane/LP fuel tank of less than 100 lb. capacity.
10. This firebox should not be installed in a bedroom or bathroom.
11. Do not add extra logs or ornaments such as pine cones, vermiculite, or rock wool. Using these added items can cause sooting. Do not add lava rock around base. Rock and debris could fall into the control area of fireplace. After servicing, always replace screen before operating fireplace.
12. Use only provided hood (See page 8).
QUALIFIED INSTALLING AGENCY
Only a qualified agency should perform installation and replacement of gas piping, gas utilization equipment or accessories, and repair and servicing of equipment. The term “qualified agency” means any individual, firm, corporation, or company that either in person or through a representative is engaged in and is responsible for:
a) Installing, testing, or replacing gas piping or
b) Connecting, installing, testing, repairing, or servicing equipment; that is experienced in such work; that is familiar
with all precautions required; and that has complied with all the requirement of the authority having jurisdiction.
PRODUCT FEATURES
OPERATION
This firebox is designed for use with approved ANSI Z21.11.2 decorative type unvented room fireplaces. (Physical size limitations apply. Refer to minimum firebox requirements supplied with log fireplace.) It requires no outside venting or chimney making installation easy and inexpensive. When used without the blower, the firebox requires no electricity making it ideal for emergency backup heat.
LOCAL CODES
Install and use fireplace with care. Follow all codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code, ANSI Z223.1, also known as NFPA 54*.
*Available from:
American National Standards Institute, lnc. National Fire Protection Association, lnc. 1430 Broadway 1 Batterymarch Park
New York, NY 10018 Quincy, MA 02269-9101
4
Loading...
+ 9 hidden pages