Procom DTA-F User Manual

Data Sheet
DTA-F
Desk Call Station as Fire Brigade Call Station
www.dvs-21.de
DTA-F
Desk Call Station as Fire Brigade Call Station
Fig. 1: DTA-F-048
Fire brigade call station
At a Glance:
Designed as call station with call signal and integrated function monitor for the microphone and the NF connection for interior use (control centres and rooms, switching rooms, etc.)
Scaleable housing with 12, 30, 48, 66, or 84 illuminated buttons, electronics constructed identically
Large range thanks to analogue voice transmission, control and signal data over a robust modem connection
Freely programmable key functions (e.g. EL/WL operation with acknowledge function, louder/softer, alarm display and acknowledge function)
Connection through plug-in cable with 4 or 6-wire technology
Internal function and connection test
Date:
16.03.2009
Page:
1/6
Author:
VS
Document-No.:
DB_DTA-F_1148_01
Data Sheet
DTA-F
Desk Call Station as Fire Brigade Call Station
Specifications of the Fire Brigade Call Station:
The following describes the functionality of the DTA as fire brigade call station.
The fire brigade call station DTA-F is a variation of each of the standard call stations DTA-012 / 030 / 048 / 066 / 084. In respect to the modes of operation, intercom and public address, it is identical in terms of functionality with the standard DTA call stations. Added to this was the option of monitoring the functionality of the microphone, as required in the standard, VDE 0828 / DIN EN 60849 (Emergency Sound Systems). For this the call station is fitted in the factory with a special gooseneck microphone and the monitoring functions. This way, in respect to cyclical monitoring of the LF transmission path, call station outage can be detected and signalled on time.
ICS Programming:
Busy signals, voice acknowledgments and call signals are indicated by the LEDs. The display and blink behaviour of the LEDs can be programmed with the system software ICS of the DVS-21.
www.dvs-21.de
To connect the call station to the DVS­21, a 4NSA module with 7 kHz monitoring attachment (order no. 2.301) is required.
Fig. 2: ICS module configuration 4NSA (excerpt)
Date:
16.03.2009
Page:
2/6
Author:
To activate the “fire brigade call station” functionality it is necessary to activate LF monitoring in the configuration window for the 4NSA module.
The monitoring interval can be specified when LF monitoring is active.
VS