ProBuilt Wobblelight 175-watt Metal Halide, Wobblelight 400-watt Metal Halide, Wobblelight 500-watt Halogen Quick Start Manual

Click Here To View
Item at
www.GapPower.com
Manufactured by ProBuilt Professional Lighting: 877-707-0800
Thank you for purchasing Wobblelight
®
IMPORTANT SAFETY INSTRUCTIONS
WARNING !!!
READ AND UNDERSTAND ALL INSTRUCTIONS
Failure to follow all instructions listed below may result in electric shock, fire and/or serious inj ury.
SAVE THESE INSTRUCTIONS
This manual contains important safety and operating instructions for Wobblelight following safety instructions carefully and read all labels on the Wobblelight
INSTRUCTIONS PERTAINING TO THE RISK OF FIRE, ELECTRIC SHOCK, EXPOSURE TO UV RADIATION AND INJURY TO PERSONS:
WARNING: To reduce the risk of fire, electric shock, exposure to excessive UV radiation or injury to persons:
x DO NOT connect Wobblelight x Metal halide and halogen bulbs get EXTREMELY HOT immediately upon illumination and can cause burns. x Bulbs stay hot for an extended period of time after Wobblelight
®
to power source until the bulb is installed and the unit is completely assembled.
®
unit has been turned off, and can continue to cause burns.
x DO NOT attempt to remove the protective lens to change bulbs unless the Wobblelight
completely cooled.
x Not for use in wet locations. DO NOT use Wobblelight
standing water.
x DO NOT leave Wobblelight x Connect Wobblelight
Any other connection voids warranty.
x Wobblelight
®
is not recommended for use with generators except under emergency situations or when the generator output power is carefully monitored to
®
®
units operating for extended periods of time in unattended areas.
only to 120 volt, 60 Hz power source which is protected with a ground-fault circuit interrupter (GFCI) and over-current protection.
®
where this is potential for exposure to excessive moisture from rain, snow, ice or water spray or
stay within +/-10% of 120V.
x Keep away from flammable materials. x Wobblelight
®
must be operated in the upright position only. DO NOT mount Wobblelight® units upside down or restrain them such that they lay on their
side.
x Use only approved extension cords in good condition and of the appropriate type, gauge and length for each application.
®
portable job site lighting. Before using Wobblelight®, please review all of the
®
unit.
®
unit is disconnected from the power source and the bulb has
x Keep extensions cords dry and use ground fault circuit interrupter (GCFI) devices in accordance with all a pplicable electrical code requirements. x DO NOT operate Wobblelight
damaged electrical receptacles. Take any damaged units out of service immediately. Replacement parts and/or repair services are available from Wobblelight
®
or a local authorized service center.
x DO NOT exceed the labeled amperage for the Wobblelight x DO NOT attempt to remove, alter or disable the Wobblelight x Use only designated replacement bulbs of the appropriate type, shape and wattage. x DO NOT expose Wobblelight x DO NOT expose Wobblelight x Disassembly of Wobblelight
®
units with the protective dome and cap missing or broken. DO NOT use Wobblelight® units with a broken housing or
®
accessory outlet (see Accessory Receptacle Instructions).
®
circuit breaker.
®
to intense heat or sparks from welding slag, cutting torches, metal saws, etc.
®
to corrosive chemicals, excessive paint spray or abrasive blasting materials.
®
will void the warranty. Contact Wobblelight® or a local authorized service center for repairs and replacement parts.
WARNING: Deviation from these instructions may result in the increased risk of fire, electric shock, injury to persons or property damage.
Specific Precautions for Metal Halide Units
175-watt Metal Halide Wobblelight® 400-watt Metal Halide Wobblelight®
WARNING!
The following instructions must be followed in order to avoid the risk of personal injury, property damage and poor lamp performance.
I. RUPTURE RISKS: Metal halide lamps are constructed of an outer glass bulb with an internal arc-tube. Metal halide arc-tubes operate at high
pressure and at very high temperatures and can unexpectedly rupture due to internal causes or external factors such as ballast failure or misapplication. An arc-tube rupture can burst and shatter the outer glass bulb resulting in the discharge of glass fragments and extremely hot particles. In the event of such a rupture, THERE IS A RISK OF PERSONAL INJURY, PROPERTY DAMAGE, BURNS AND FIRE.
TO REDUCE THESE RISKS:
1. Only operate lamp in the enclosed Wobblelight
2. Only operate lamp with compatible ballast (see bulb manufacturer catalog or contact Wobblelight
3. Only operate lamp in the upright operating position.
4. Lamp must be turned off for a minimum of 15 minutes at least once per week.
5. Never expose an operating lamp to moisture such as rain, sleet or snow.
6. Replace lamp if outer glass is scratched, cracked or damaged in any way.
7. Replace lamp at or before the end of rated life (see bulb manufacturer catalog for rated life).
8. To avoid risk of serious eye injury from the intense light, do not stare at the operating lamp.
II. ELECTRICAL SHOCK AND BURN HAZARD: Do not remove or insert lamp while power is on. If outer glass is broken, shut off power immediately
and remove lamp after it has completely cooled.
III. ULTRAVIOLET RADIATION EXPSOURE: WARNING: Metal halide lamps can cause skin burn and eye inflammation from shortwave
ultraviolet radiation if the outer envelope of the lamp is broken or punctured. Do not use where people will remain for more than a few minutes unless adequate shielding or other safety precautions are used. The following designated Wobblelight CFR 1040.30 (USA) and S0R/80-381 (Canada):
®
fixture with dome and cap installed and free of damage.
®
for specific information).
®
metal halide lamps conform to federal regulations 21
Loading...
+ 5 hidden pages