Setup Instructions
Anamorphic Lens
H-FE850R
Setup Instructions
Setting up the system:
STEP 4
Make sure the projector is turned on. It is helpful
to have a picture that fills the entire panel of 16:9
projector. With a 2.40:1 source material the
vertical expand is good to be performed to the
picture at this step. (Fig 4)
Now carefully adjust the focus of projector. Also
make sure the image is symmetrically in the
center of the 2.40:1 screen.
STEP 5
First move the prisms to the ‘pass’ mode using
the supplied remote controller until the prisms
stop. Carefully position the lens with a stand in
front of the projector, with the small opening
closest to the projector lens and the large
opening pointing towards the screen.
Now manually adjust the lens in a stand. Make
sure the entire beam fits centered within the
two lenses (Fig 5). Lower, raise and tilt the lens
until the desired height and angle is reached.
Make sure the image is now rectangular and still
symmetrically in the center of the screen.
NOTE: The optimum symmetry for the projected
picture can only be found by tilting the lens to the
direction of the beam
Fig 4
Fig 5
STEP 9
In case the friction based lens height (Fig 9-a) or
the tilt (Fig 9-b) adjusting mechanism become too
loose, it is possible to get them tightened with the
set screws of stand drums on both sides of lens.
Use the L-wrench, 4 mm for tightening the
screws.
You’re done. Enjoy your new 2.40:1 picture!
NOTE: H-FE850R i ntroduces som e horizontal o ffset to
the image. Offset is to the left for table mounted, and to
the right for ceiling mounted lens. This must be
compensated by horizontally shifting the sc reen in
respect to the projector, or if available, using the
horizontal lens shift of projector.
STEP 6
Using the remote control, press ‘wide’ until the
prisms stop again. The tuning of picture width can
be accomplished manually by adjusting the cap
screws inside the lens to match your screen
perfectly on both sides.
NOTE: Tuning is done with the cap screws to where the
prisms stop after turning the knobs to the ‘wide’
position (Fig 6)
Fig 6
rear view
front view
STEP 8
Take the front element, remove the cover sheets
and secure it to the lens body using the four
screws (Fig 8).
You slightly have to zoom in the picture after
front element installation. Also now adjust the
focus and picture in a ‘wide’ mode to achieve
the optimum settings, and note these settings
as for future reference.
Fig 8
Fig 9
a)
b)
Only use optically safe lens cleaning solutions and a clean,
lint-free cloth certified for cleaning of lens materia ls. In
order to clean the optics from both sides, the bottom plate
can be temporarily removed.
Fig 7
rear view
front view
STEP 7
If the sides of picture are not opening/closing synchronously to each other when switching the modes, tune
the terminal screws to where the prisms stop after pressing the ‘pass’ button (Fig 7). Open the cap screw of
the prism which had a shorter travel, and close the cap screw of that prism, which had a longer travel until
both sides of picture are opening and closing synchronously to each other.
Cleaning the optics:
Maintenance:
Your Prismasonic lens was designed to require very minimal cleaning. It is best to only wipe the lens housing
with a clean, damp, soft cloth when needed.
Anamorphic Lens
H-FE850R