Prismasonic Cinomorph C-100F Installation Instructions Manual

Anamorphic Lens
Cinomorph C-150R
Setup Instructions
INSTALLATION INSTRUCTIONS
Carefully remove and unwrap all the contents of box. Referring to the parts list, make sure you have everything needed to proceed with the installation of the lens. If any parts are missing, contact Prismasonic immediately.
Inspect the lens to make sure there are no shipping defects. If you notice a problem with the lens itself, or the lens’ mechanical system, contact Prismasonic immediately.
Parts list:
Lens Unit
Shipping Rail (2 pcs)
Stand Plate
Stand Rail (4 pcs)
Stand Rail Extenders (4 pcs)
Slide Lock (4 pcs)
Power Cord
Power Co nverter
Remote Controller
L-Wrench 2, mm
L-Wrench 3, mm
L-Wrench 4, mm
L-Wrench 5, mm
Black Cap (2 pcs)
Skt Cap Screw, M6 x 10 (6 pcs)
Instruction Manual
Bringing the lens into the use:
Flip the lens unit with shipping rails upside down on a table. By using the L-wrench, 5 mm carefully remove the delivery lock screws of both lenses from the bottom plate (Fig 1-a). After this release the two upper screws of front element (Fig 1-b) by using the L-wrench, 3mm.
STEP 2
Remove the bottom plate (Fig 2) of housing by releasing the four screws on the bottom plate (Fig 1-c). Now carefully take off the plastic cover coats from both sides of both lense s. Remove also the cover coats from both IR win dows of both motor boxes.
STEP 3
Insert the bottom plate back to the housing and prepare to affix the four screws (Fig 3-a) with L- wrench 3mm. Tighten the screws securely. Also insert the black caps into the slots of bottom plate (Fig 3-b).
Now also attach the two cap screws of front plate back to their places (Fig 3-c).
Anamorphic Lens
Cinomorph C-150R
A Picture to
Remember
Fig 3
c)
c)
a)
b)
a)
a)
a)
b)
Fig 2
Fig 1
b)
b)
c)
a)
c)
c)
c)
a)
Setup Instructions
Anamorphic Lens
Cinomorph C-150R
Setup Instructions
STEP 4
Flip the lens unit back upright. Remove the motor cover of motor box by releasing the four cap screws using the L-wrench 3 mm (Fig 4-a).
After this, using the L-wrench, 4 mm, remove th e both shipping rails, shown with arrows in a Fig 4, by releasing t he each cap screw, M6 x 10, locating under the motor cover (Fig 4-b).
STEP 5 Now, refer to Fig 5, attach the four stand rails to stand plate with cap screws, M6 x 10. Make sure
the 12 mm Ø rails and 15 mm Ø rails are placed to the correct spots on a stand plate. Tighten screws in the slots of stand plate securely using the L -
wrench, 4 mm.
in this step also insert the four slide locks to their places on a stand rails 15 mm Ø. Make sure the each lock pair is in a same plane on a rail. The final positions to the locks will be defined by yo ur setup, and thus they may need to be repositioned later, when setting up the system.
NOTE: Some setups may need an extra height to the slide travel. In order to extend the travel, use the rail extenders, depending on a requirement, in one end only, or in both ends of main rails (Fig 5). The set of extension rails increases the slide travel for 4.5 cm. The each extension rail is screwed securely into the main rail, after which it is working as a single, longer stand rail.
STEP 6 Now very carefully set the lens unit onto the stand plate with stand rails as presented in Fig 6,
so that 12 mm Ø rails go through the linear bearings of lens drums on sides. Refer to Fig 6, turn the upper slide locks aside from the lens when inserting the lens. Connect the lens unit to four rails with cap screws, M6 x 10 (Fig 6-a). Tighten the screws securely using the L -wrench,
4 mm
Finally attach the motor cover back with four cap screws using the L-wrench 3 mm (Fig 6-b).
Your lens is now ready for setting up !
Fig 7
STEP 7
Make sure the projector is turned on. It is helpful to have a picture that fills the entire panel of 16:9 projector. With a 2.40:1 source material the vertical expand is good to be performed to the picture at this step (Fig 7).
Now carefully adjust the focus of projector. Also make sure the image is symmetrically in the center of the 2.40:1 screen.
Setting up the system:
Anamorphic Lens
Cinomorph C-150R
Fig 4
a)
a)
a)
a)
b)
b)
Fig 5
Fig 6
a)
a)
a)
a)
b)
b)
b)
b)
Setup Instructions
Anamorphic Lens
Cinomorph C-150R
STEP 8
Make sure the power plug has been connected to th e so ck et o f l ens mot or box , lo ca tin g o n th e r ear IR window.
Carefully position the lens with a lift stand in front of the projector, with the small opening closest to the projector lens and the large opening pointing towards the screen.
Now press and hold the ‘in’ button of remote controller until the lens has reached the level of projector’s optics. Make sure the entire beam fits centered within the two lenses (Fig 8). Lower, raise, turn and tilt the lens until the desired height and angle is reached, and the picture is symmetrically in the center of the 2.40:1 screen.
Now move the lower pair of slide locks into the contact with stand drums, exactly as illustrated in Fig 8. M ake sure the locks are exactly at the same plane.
NOTE: The optimum symmetry for the projected picture can only be found by tilting the lens to the direction of the beam
STEP 12
In case the friction based tilt adjusting mechanism (Fig 12) become too loose, it is possible to get it tightened with the set screws of stand drums on both sides of lens. Use the L-wrench, 4 mm for tightening the screws.
STEP 9
Switch the power cord from lens lift system to the focus control socket. Now adjust the lens focus. Using the remote control, press and hold “in” or “out” (Fig 9) until the 2.40:1 picture gets focused. It is helpful to use a test grid to monitor when the horizontal and vertical lines in picture become in focus simultaneously. After the focus has been adjusted, switch the power cord back to the lens lift system.
Fig 12
Setup Instructions
STEP 11
For the presentation of native 16:9 material press and hold the ‘out ’ button of remote controller until the lens has completely moved aside from the beam (Fig 11). Make sure the lens do not hit the plate of motor box. If needed use the rail extenders to get more travel to the lens.
Now move the upper pair of slide locks into the contact with stand drums, exactly as il lustrated in Fig 11. Again, make sure they are in a same level with each other. Finally, after the correct position is found, tighten the set screws of all four slide locks by using L-wrench, 4mm.
Fig 10
STEP 10
In case there exists imbalance in focus between the left and right sides of picture, it is possible to correct it by fine rotating the small lens. Using the
L-wrench, 2 mm, by opening the other set screw and closing the other for the same amount (Fig
10), it is possible to rotate the small lens to either
direction and thus find the perfect balance between the sides. Good adjusting step for the screws of this iterative tuning process is quarter round at the time, after which every time the picture is refocused by the lens.
If the imbalance gets worse after first iteration round, this indicates that the lens has to be rotated to other direction in order to find the calibration sweet spot.
Anamorphic Lens
Cinomorph C-150R
Fig 8
Fig 9
Fig 11
Setup Instructions
Anamorphic Lens
Cinomorph C-150R
Setup Instructions
MAKE YOUR NOTES HERE
SPECIAL NOTES:
Use the lens only in an upright position. The lift system does NOT work, and may get damaged, if the lens is used upside down.
If, however, the lens is flipped upside down e.g. for the installation of rail extenders, make sure the lens has been driven up, and is in contact with the motor plate of slide.
Save the shipping rails, and use them in case of re-shipment of the lens
Anamorphic Lens
Cinomorph C-150R
Yo u’r e do ne . Enjoy your new 2.40:1 picture!
Maintenance:
Your Prismasonic lens was designed to require very minimal cleaning. It is best to only wipe the lens housing with a clean, damp, soft cloth when needed.
Cleaning the optics:
Only use optically safe lens cleaning solutions and a clean, lint-free cloth certified for cleaning of lens materials. In order to clean the optics from both sides, the bottom plate can be temporarily removed.
Loading...