PL220 Automatic Slide Oiler
Worldwide
distribution
© Prior Scientific Instruments Ltd., UK
Version 2.2 November 2015 Page 2
Table of Contents
SECTION 1
SECTION 2
SECTION 3 INSTALLATION 7
3.1 IDENTIFYING THE PARTS OF THE PL220 CONTROLLER 7
3.2 IDENTIFYING THE PARTS OF THE DISPENSING TIP ASSEMBL. 8
3.3 SET UP OF PL220 9
3.4
POSITIONING
3.4
INSTALLATION
SECTION 4 SOFTWARE COMMANDS 13
SECTION 5
SECTION 6
RETURNS AND REPAIRS 16
SECTION 7 TECHNICAL SPECIFICATIONS 17
SECTION 8 TECHNICAL SPECIFICATIONS 18
IMPORTANT
UNPACKING
SAFETY INFORMATION 4
& INSPECTION 6
OF OIL DISPESNSER 10
OF COM PORT 12
REPLACEMENT
MAINTENANCE,
PARTS 15
TROUBLESHOOTING
© Prior Scientific Instruments Ltd., UK
Version 2.2 November 2015 Page 3
Thank you very much for purchasing this product from Prior Scientific. We are confident it will prove to be a reliable, precise and valuable addition to your microscopy system. do
take the time to read these instructions before attempting to install and use this product. This manual contains both important safety information and instructions on how to successfully utilise the oil dispenser. Only use this product as specified in these instructions, or having first talked to Prior Scientific.
Pleas
e
© Prior Scientific Instruments Ltd., UK
Version 2.2 November 2015 Page 4
IMPORTANT
SAFETY INFORMATION
SECTION 1
Always observe the following safety precautions
This symbol, used on the pump and in this manual, means: Caution, refer to accompanying documents
Use only as specified by these operating instructions or the intrinsic protection provided by the unit may be impaired.
Before using the stage system, please follow and adhere to all warnings, safety and operating instructions located on the product and in this User Manual.
DO NOT expose the product to water or moisture while energised.
DO NOT expose the product to extreme hot or cold temperatures.
DANGER – Never alter the AC cord or plug. The power cord set must be an appropriately rated and approved cord set in accordance in the regulations of the country it is used in. If the supplied plug adapter is not the correct fitting for your geographic area or if you are unsure about the relevant regulations, please contact your supplier for advice
Only use the supplied AC/DC adapter with this product. Never substitute another adapter. Should the adapter be in any way faulty or damaged contact your supplier.
DO NOT expose the product to open flames.
DO NOT allow objects to fall on or liquids to spill on the product.
Make sure the electrical cord is located so that it will not be subject to damage.
Make sure the system in installed so that the front panel power switch is easily accessible.
Do not position equipment so that it is difficult to disconnect from power supply.
© Prior Scientific Instruments Ltd., UK
Version 2.2 November 2015 Page 5
To reduce the risk of damage, unplug the product from the power source before connecting the components together.
This equipment contains no user-serviceable parts. Refer all repairs to qualified service personnel.
DO NOT run the pump dry for excessive periods. Roller and tubing temperatures can exceed normal operating range.
DO NOT run pump against a dead-end condition (closed
discharge).This
can lead to
excessive roller and tubing temperatures and pressures
Rating: The pump is rated as Group II, Category 2 equipment, with a T4 temperature classification, for use in gas based environments.
Save this manual as it contains important safety information and operating instructions
SAFETY SYMBOLS
This symbol used on the pump means - Caution refer to accompanying documents.
This symbol used on the pump means. DO NOT allow fingers to contact moving parts.
© Prior Scientific Instruments Ltd., UK
Version 2.2 November 2015 Page 6
UNPACKING
YOUR PRODUCT
SECTION 2
Carefully unpack the unit and retain packaging to return equipment for servicing.
If the equipment appears damaged in any way, return it to sales outlet in its original packaging. No responsibility for damage arising from the use of non­approved packaging will be accepted.
Ensure all items and accessories specified are present. If not, contact your sales outlet or us at the address at the back of the manual.
- Mains adaptor & PSU
- PL220 Control Box
- Oil Reservoir Bottle
- Tubing (1m x 1.6mm bore x 1.6mm wall)
- USB Cable
- RS232 comms cable
- Oil Dispenser Assembly